• 제목/요약/키워드: PWM inverter

검색결과 1,383건 처리시간 0.026초

대용량 인버터 시스템을 위한 공간벡터 PWM 인버터의 병렬 운전 (Parallel Operation of Space Vector PWM Inverters for Large Capacity Inverter System)

  • 지준근;이현동
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.509-513
    • /
    • 2000
  • This paper deals with the parallel operation of space vector PWM for large capacity inverter system. To enlarge the capacity of inverter system and to reduce the current ripples on inverter output side, two or more inverters are operated in parallel. In this paper, a new parallel operation strategy which minimizes the harmonic distortion of the output stage is described. The proposed method is developed on the basis of the space-vector PWM in order to increase the linearly controllable voltage range. With the help of the proposed voltage synthesis method, the total harmonic distortion of the output stage can be greatly reduced in compared with that of conventional method with sinusoidal PWM or that of the single inverter operation case. The experimental results with reduced scale test show the feasibility of the proposed voltage synthesis method.

  • PDF

출력 전압 파형 개선을 위한 새로운 11 레벨 PWM 인버터 (A Novel 11-Level PWM Inverter for Improving Output Voltage Waveform)

  • 강필순;박성준;김철우
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.99-106
    • /
    • 2003
  • 본 논문에서는 출력 전압 파형을 개선하고 고조파 성분을 저감시키기 위한 한 방법으로 변압기 2차측을 직렬로 결합시킨 형태를 가지는 새로운 멀티 레벨 인버터를 제안한다. 제안된 11 레벨 PWM 인버터는 출력 전압의 각 레벨을 형성하기 위한 두 개의 level 인버터 모듈과 PWM 스위칭 동작을 위한 PWM 인버터 모듈, 그리고 3대의 변압기로 구성된다. 적절한 변압기의 권선비를 이용하여 직류 전원에 대한 정수비의 연속적인 출력 전압 레벨을 형성하였으며, 변압기의 직렬 결합으로 출력단의 필터용 인덕허가 필요 없는 장점을 가진다. 제안하는 PWM 인버터의 타당성을 입증하기 위해 24 [V] 직류 전원에서 220 [V] 교류 전원을 발생시킬 수 있는 인버터의 시작품을 제작하고 실험을 행하였으며, 기존의 멀티 레벨 방식을 이용한 11 레벨 PWM 인버터와 제안된 11 레벨 PWM 인버터의 비교를 통해 제안하는 인버터의 타당성을 검증하였다.

PWM 방식과 인버터 방식을 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(난방저온 특성) (Experimental Study on Performance Evaluation of System A/C using PWM or Inverter Method (Heating Characteristics at Low Temperature Conditions))

  • 김대훈;전용호;권영철;이윤수;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.551-556
    • /
    • 2003
  • The present study concerns an experiment on the heating characteristics of a system air-conditioner (A/C) using PWM method or inverter method at low temperature con-ditions. The compressors used are digital scroll type and BLDC inverter type. Under the low outside temperature condition, -5$^{\circ}C$, -1$0^{\circ}C$, -15$^{\circ}C$, heating capacities and COPs are mea-sured by the psychometric calorimeter using air enthalpy method. Also, outlet air temperatures at heating operation mode are measured at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$. Experimental results show that COPs of the system A/C using a PWM method are more effective than those of the inverter method at heating operation mode. Although the heater is on, COPs of PWM method are similar to those of BLDC inverter method. Moreover, the heating capacities of PWM method at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$ are larger about 10~20% and outlet air tempe-rature at -15$^{\circ}C$ is larger about 10%, compared to the inverter method.

태양광발전과 계통연계를 위한 Buck-Boost 전류원형 PWM 인버터에 관한 연구 (A Study of Buck-Boost Current-Source PWM Inverter for Utility Interactive Photovoltaic Generation System)

  • 양근령;강필순;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.63-68
    • /
    • 2002
  • In a utility interactive photovoltaic generation system, a PWM inverter is used for the connection between the photovoltaic arrays and the utility. The do current becomes pulsated when the conventional inverter system operates in the continuous current mode and dc current pulsation causes the distortion of the ac current waveform. To reduce pulsation of dc input current, This paper presents a Buck-Boost PWM power inverter and its application for residential photovoltaic system. The PWM power inverter is realized by combining two sets of a high frequency Buck-Boost chopper and by making it operate in the discontinuous conduction mode. In this paper, we show the Buck-Boost PWM power inverter circuit, its equivalent circuit and basic differential equations and the power flow characteristics are clarified when the proposed Inverter is interconnected with the utility lines. In conclusion, the proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor

  • PDF

유도 가열용에 사용되어지는 새로운 부분공진형 영전압 스위칭 PWM 고주파 인버터 (New Partial Resonant Zero Voltage Switching PWM High Frequency Inverter using Induction Heating)

  • 정영수;문상필;박한석
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.261-266
    • /
    • 2015
  • This paper presents a newly proposed prototype of voltage-fed half-bridge partial resonant zero voltage switching PWM inverter operating at a constant frequency variable power regulation scheme, which is more suitable and acceptable for induction heated(IH) cooking appliances. This application-specific high frequency inverter circuit topology using a new generation specially-designed IGBTs can operate under a principle of a fixed frequency ZVS-PWM strategy. The operating principle of a new partial resonant inverter circuit is described on the basis of its computer-aided simulation analysis, its including steady-state operating characteristics.

A Novel Filter Design for Output LC Filters of PWM Inverters

  • Kim, Hyo-Sung;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • 제11권1호
    • /
    • pp.74-81
    • /
    • 2011
  • The cutoff frequency of the output LC filters of PWM inverters limits the control bandwidth of the converter system while it attenuates voltage ripples that are caused by inverter switching activities. For a selected cutoff frequency of an output LC filter, an infinite number of L-C combinations is possible. This paper analyses the characteristics of output LC filters for PWM inverters terms of the L-C combinations. Practical circuit conditions such as no-loads, full resistive-loads, and inductive-load conditions are considered in the analysis. This paper proposes a LC filter design method for PWM inverters considering both the voltage ynamics and he inverter stack size. An experimental PWM inverter system based on the proposed output LC lter design uideline is built and tested.

능동소음기를 위한 PWM 인버터의 제어기법 및 적용 (Control Method and Application of PWM Inverter for Active Silencer)

  • 이승용;최규하;강정유;장도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.311-314
    • /
    • 1995
  • PWM(Pulse-Width Modulation) is frequently used as control method for inverter. In control of active silencer studied presently, PWM control method can be applied. This paper presents its possibility. As operating source of loudspeaker, inverter is used instead of audio amplifier and PWM controller controls the inverter to make canceling sound. This paper presents that active silencer of inverter-type using the PWM control method makes the canceling sound to acoustic noise and cancels the acoustic noise.

  • PDF

브리지형 공진 AC 링크 스너버 방식을 이용한 3상 정현파 소프트 스위칭 PWM 인버터 (Three Phase Sinewave Soft-switching PWM Inverter using Bridge Type Resonant AC Link Snubber)

  • 김정식;문상필;박한석
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.58-62
    • /
    • 2017
  • This paper presents a novel prototype of the resonant AC link snubber circuit for the three-phase sinwave soft-switching PWM inverter. In principle, its operating principle is described, and the performance evaluations of the specific instantaneous space voltage modulated three-phase sinewave soft switching PWM inverter incorporating a resonant AC link snubber is illustrated, and evaluated, introducing the specific space voltage vector modulation implementation. It is conferred that the validity of three-phase soft-switching inverter treated here in setup experiment.

Random PWM을 이용한 Compressor의 스위칭 소음 저감 (Switching Noise Reduction for Compressor using Random PWM)

  • 양순배;김학원;조관열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.688-691
    • /
    • 1999
  • Recently, it is increased to adopt inverter system to household electrical appliances, especially in ai conditioner and refrigerator. Inverter system is adopted for improving the efficiency. But Inverter system makes acoustic noise caused by switching frequency. In household electrical appliace, it is important to reduce acoustic noise. And in some cases it is possible to magnify the acoustic noise caused by switching, by system which may have different transfer characteristic. In this paper, random PWM method was adopted in inverter refrigerator using 8 bit microprocesso. We found useful PWM frequency and adoptation method.

  • PDF

4 - 레벨 출력을 갖는 단상 인버어터의 PWM (PWM for Single Phase Inverter with 4 - Level Output)

  • 장현수;진명철;이광원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.527-530
    • /
    • 1989
  • In order to reduce harmonic contents in the inverter output, various PWM ( pulse with modulation ) techniques have been utilized. This paper suggests a single phase inverter with 4-level output and its PWM control scheme. The proposed 4-level output inverter shows better performence than the 3-level output one in respects of the current error and the switching frequency.

  • PDF