• 제목/요약/키워드: PWM Control

검색결과 2,049건 처리시간 0.028초

Three-Phase PWM Inverter and Rectifier with Two-Switch Auxiliary Resonant DC Link Snubber-Assisted

  • Nagai Shinichiro;Sato Shinji;Matsumoto Takayuki
    • Journal of Power Electronics
    • /
    • 제5권3호
    • /
    • pp.233-239
    • /
    • 2005
  • In this paper, a new conceptual circuit configuration of a 3-phase voltage source, soft switching AC-DC-AC converter using an IGBT module, which has one ARCPL circuit and one ARDCL circuit, is presented. In actuality, the ARCPL circuit is applied in the 3-phase voltage source rectifier side, and the ARDCL circuit is in the inverter side. And more, each power semiconductor device has a novel clamp snubber circuit, which can save the power semiconductor device from voltage and current across each power device. The proposed soft switching circuits have only two active power semiconductor devices. These ARCPL and ARDCL circuits consist of fewer parts than the conventional soft switching circuit. Furthermore, the proposed 3-phase voltage source soft switching AC-DC-AC power conversion system needs no additional sensor for complete soft switching as compared with the conventional 3-phase voltage source AC-DC-AC power conversion system. In addition to this, these soft switching circuits operate only once in one sampling term. Therefore, the power conversion efficiency of the proposed AC-DC-AC converter system will get higher than a conventional soft switching converter system because of the reduced ARCPL and ARDCL circuit losses. The operation timing and terms for ARDCL and ARCPL circuits are calculated and controlled by the smoothing DC capacitor voltage and the output AC current. Using this control, the loss of the soft switching circuits are reduced owing to reduced resonant inductor current in ARCPL and ARDCL circuits as compared with the conventional controlled soft switching power conversion system. The operating performances of proposed soft switching AC-DC-AC converter treated here are evaluated on the basis of experimental results in a 50kVA setup in this paper. As a result of experiment on the 50kVA system, it was confirmed that the proposed circuit could reduce conduction noise below 10 MHz and improve the conversion efficiency from 88. 5% to 90.5%, when compared with the hard switching circuit.

병렬 삼상 부스트 컨버터에서 일반화된 순환전류 제어 방법 (Generalized Circulating Current Control Method in Parallel Three-Phase Boost Converters)

  • 임창순;이귀준;김래영;현동석
    • 전력전자학회논문지
    • /
    • 제16권3호
    • /
    • pp.250-257
    • /
    • 2011
  • 본 논문은 병렬 삼상 부스트 컨버터에서 Interleaved PWM에 의해 발생하는 고 주파수 순환전류를 효과적으로 저감시키기 위해서, AC 입력단에 연결되는 삼상 결합 인덕터의 특성을 분석하였다. 제시된 삼상 결합 인덕터 분석은 삼상 결합 인덕터의 구조와 전압 방정식의 해석을 통하여 이루어졌다. 그리고 이것을 바탕으로 기존의 저 주파수 평균화 모델에 삼상 결합 인덕터를 추가하여, 고 주파수 순환전류와 저 주파수 순환전류를 동시에 저감시킬 수 있는 새로운 형태의 평균화 모델을 제안하였다. 새로운 평균화 모델의 영상성분을 이용하면, 삼상 결합 인덕터와 라인 인덕터의 순환전류에 대한 총 인덕턴스를 각각 구해 비교 할 수 있다. 시뮬레이션과 실험결과를 토대로 병렬 삼상 부스트 컨버터에서 사용되는 삼상 결합 인덕터의 유용성을 검증하였다.

영구자석 동기전동기 구동 인버터 스위치의 개방 고장에 의한 제어 특성해석 및 고장모델 연구 (A Study on Fault Model end Performance Evaluation under Power Switch Open Fault in an Inverter-Driven Permanent Magnets Synchronous Motor)

  • 김경화;최동욱;구본관;정인성
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.40-51
    • /
    • 2009
  • 인버터 스위치의 개당 혹은 인버터와 모터 터미널의 분리로 인해 발생하는 고장을 해석하고 진단 알고리즘의 시험 평가를 위해 효과적으로 사용할 수 있는 영구자석 동기전동기 구동 인버터의 개방 고장에 의한 제어 특성해석 및 고장모델이 제시된다. 기존의 전동기의 해석과 제어에 많이 사용되는 dq 모델은 상전압 모델을 변환한 것으로 고장 상황에서는 3상평형 조건이 성립하지 않기 때문에 개방 회로의 입력 전압을 구하기가 쉽지 않아 고장 모델의 해석을 위해 직접 사용하기 어렵다. 이를 해결하기 위해 스위치 개방에 따른 전통기의 선전압 관계를 이용한 인버터의 고장 모델이 제안되고 제안된 고장모델의 타당성을 입증하기 위해 시뮬레이션이 수행된다. 전체 시스템이 DSP TMS320F28335에 의해 구현되어 동일 고장 조건에서의 비교 실험과 특성 해석이 수행된다.

직류단 전압의 고조파 맥동 검출을 이용한 3상 다이오드 정류기의 고장 진단 (Fault Diagnosis for 3-Phase Diode Rectifier using Harmonic Ripples of DC Link Voltage)

  • 박제욱;백승원;김장목;이동춘;이교범
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.457-465
    • /
    • 2011
  • 본 논문에서는 3상 다이오드 정류기의 고장에 따른 해석 및 고장 판별 기법을 제안한다. 입력전원이나 다이오드소자에 고장이 발생하게 되면 출력 직류단 전압에 큰 맥동을 유발하며 이는 인버터 시스템의 제어 성능을 저하시킬 뿐만 아니라 커패시터의 수명 단축을 야기한다. 본 논문에서는 입력측의 지락 사고 및 다이오드 개방 사고 시의 직류단 전압 특성을 분석하고, 계통주파수의 6배에 주파수마다 측정된 직류단의 순시전압을 직류단 평균 전압과 비교함으로서 고장의 유무 및 종류를 판별하는 알고리즘을 제안하였다. 제안한 알고리즘은 직류단 전압 센서만을 이용하므로 구현이 간단하고 고장 진단을 위한 추가적인 하드웨어가 요구되지 않는다. 실험과 시뮬레이션을 통해 제안한 고장 진단 알고리즘의 타당성을 검증하였다.

Wireless Power Transfer for Electric Vehicles Charging Based on Hybrid Topology Switching With a Single Inverter

  • Chen, Yafei;Zhang, Hailong;Kim, Dong-Hee;Park, Sung-Jun;Park, Seong-Mi
    • 한국산업융합학회 논문집
    • /
    • 제23권2_1호
    • /
    • pp.115-124
    • /
    • 2020
  • In wireless power transfer (WPT) system, the conventional compensation topologies only can provide a constant current (CC) or constant voltage (CV) output under their resonant conditions. It is difficult to meet the CC and CV hybrid charging requirements without any other schemes. In this study, a switching hybrid topology (SHT) is proposed for CC and CV electric vehicle (EV) battery charging. By utilizing an additional capacitor and two AC switches (ACSs), a double-side LCC (DS-LCC) and an inductor and double capacitors-series (LCC-S) topologies are combined. According to the specified CC and CV charging profile, the CC and CV charging modes can be flexibly converted by the two additional ACSs. In addition, zero phase angle (ZPA) also can be achieved in both charging modes. In this method, because the operating frequency is fixed, without using PWM control, and only a small number of devices are added, it has the benefits of low-cost, easy-controllability and high efficiency. A 3.3-kW experimental prototype is configured to verify the proposed switching hybrid charger. The maximum DC efficiencies (at 3.3-kW) of the proposed SHT is 92.58%.

Real-Time HIL Simulation of the Discontinuous Conduction Mode in Voltage Source PWM Power Converters

  • Futo, Andras;Kokenyesi, Tamas;Varjasi, Istvan;Suto, Zoltan;Vajk, Istvan;Balogh, Attila;Balazs, Gergely Gyorgy
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1535-1544
    • /
    • 2017
  • Advances in FPGA technology have enabled fast real-time simulation of power converters, filters and loads. FPGA based HIL (Hardware-In-the-Loop) simulators have revolutionized control hardware and software development for power electronics. Common time step sizes in the order of 100ns are sufficient for simulating switching frequency current and voltage ripples. In order to keep the time step as small as possible, ideal switching function models are often used to simulate the phase legs. This often produces inferior results when simulating the discontinuous conduction mode (DCM) and disabled operational states. Therefore, the corresponding measurement and protection units cannot be tested properly. This paper describes a new solution for this problem utilizing a discrete-time PI controller. The PI controller simulates the proper DC and low frequency AC components of the phase leg voltage during disabled operation. It also retains the advantage of fast real-time execution of switch-based models when an accurate simulation of high frequency junction capacitor oscillations is not necessary.

항공무장 안정성 향상을 위한 날개 전개 구동기의 작동로직 설계 (Deployment Actuator Logic Design for Enhancing Aircraft Armament Stability)

  • 전선재;이기두;이진우;안효득;송원종;이진혁
    • 한국군사과학기술학회지
    • /
    • 제27권2호
    • /
    • pp.277-284
    • /
    • 2024
  • For the high reliability of guidance weapon, it is important to maintain the stable supply voltage for guidance system while the bomb is gliding. However, the DC motor drive for guidance control in the low temperature can lead to the critical voltage drop due to a large inrush current. In this paper, we propose the wing deployment logic design to enhance the guidance system stability. To derive the stable drive logic based on PWM, we controlled the duty cycles for input voltage of DC motor in low temperature. The initial duty cycle was set to 40 % to relieve the inrush current. Moreover, the proper time, which is less than 1 second for controlling duty cycles, was determined by the iterative wing deployments of guidance kit. Finally, the validity of proposed logic was confirmed from the result the maximum voltage drop for the wing deployment was decreased by 23 %.

디스플레이 응용을 위한 능동 제어형 전계 에미터 어레이의 회로 모델링 및 시뮬레이션 (Circuit Modeling and Simulation of Active Controlled Field Emitter Array for Display Application)

  • 이윤경;송윤호;유형준
    • 대한전자공학회논문지SD
    • /
    • 제38권2호
    • /
    • pp.114-121
    • /
    • 2001
  • 능동제어형 전계방출 디스플레이의 전자공급원으로서 능동제어형 전계 에미터 어레이의 회로모델이 제안되었다. 능동제어형 전계 에미터 어레이는 전계방출을 안정화시키고 저전력구동을 위한 수소화 된 비정질 실리콘 박막 트랜지스터와 Spindt형 Mo 전계 에미터 어레이로 구성되었고 같은 유리기판 위에 제작되었다. 비정질 박막 트랜지스터와 Spindt형 Mo 전계 에미터 어레이의 전기적 특성으로부터 추출된 기본 모델 변수는 제안된 능동제어형 전계 에미터 어레이 회로모델에 입력되었고 SPICE 회로 시뮬레이터를 사용하여 특성을 분석하였다. 제작된 소자의 측정값과 DC 시뮬레이션 결과를 비교한 결과 두 값이 상당히 일치함으로써 등가회로 모델의 정확성을 확인하였다. 또한 제작된 소자의 transient 시뮬레이션 결과 전계 에미터 어레이의 게이트 커패시턴스와 TFT의 구동능력이 반응시간에 가장 크게 영향을 끼치고 있음을 확인하였다. 제작된 능동제어형 전계방출 에미터 어레이는 pulse width modulation으로 구동하는 경우 15㎲의 반응시간을 얻었고 이 값으로는 4bit/color의 계조(gray scale)표현이 가능하였다.

  • PDF

연동펌프를 이용한 비료염 공급 관비재배기술 연구 (Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics)

  • 김동억;이공인;김현환;우영회;이운용;강인철
    • 현장농수산연구지
    • /
    • 제17권1호
    • /
    • pp.57-71
    • /
    • 2015
  • 본 연구에서는 산업분야에서 다양하게 이용되고 있는 연동펌프를 농축양액 주입장치로 사용한 관비장치를 개발하고 성능시험을 실시하였으며, 얻어진 결과는 다음과 같다. 튜브 내경별, 회전수별, 롤러수별 유량특성 시험결과 펌프 회전속도가 빨라짐에 따라 유량은 직선적으로 증가하였으며, 튜브 내경이 커질수록 기울기도 커졌으며, 롤러수가 3개일 때가 4개일 때의 유량 보다 더 많은 것으로 나타났다. 또한 튜브재질에 있어서는 복원력이 우수한 재질의 노프렌 튜브에서 유량이 많은 것으로 나타났다. 관비장치의 농축양액 주입위치에 따른 혼삽성능 실험결과 안정화 시간은 농축양액을 공급펌프의 흡입 측에 주입한 경우에는 17초, 공급펌프의 토출 측에 주입한 경우에는 16초 이었으며, EC는 안정화 구간에서 각각 1.42±0.05, 1.39±0.02 dS/m로 나타나 주입위치에 따른 영향은 크지 않은 것으로 판단된다. 측정 센서 설치위치에 따른 안정화시간은 주관에 삽입 설치한 경우에는 17초, 여수관에 설치한 경우에는 27초로 나타나 센서는 주관에 삽입 설치하는 것이 바람직한 것으로 판단된다. EC는 안정화 구간에서 각각 1.43±0.05, 1.45±0.07dS/m의 근소한 차이를 보였다. 시작기의 제어성능 실험결과 제어정밀도가 ±0.05dS/m로 나타나 제어성능이 우수한 것으로 나타났다. 농가 현장시험결과 개발한 관비장치에 의해 재배한 오이가 정상적인 생육을 하는 것으로 나타나 개발한 시험용 장치의 실용화가 이루어진다면 관비재배 농가에서 활용할 수 있을 것으로 판단된다.