• Title/Summary/Keyword: PVF

Search Result 48, Processing Time 0.021 seconds

Effects of Fatigue Induction on Ground Reaction Force Components, Postural Stability, and Vertical Jump Performance in Taekwondo Athletes

  • Hyun, Seung-Hyun;Kim, Young-Pyo;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.143-151
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effect of fatigue induction on ground reaction force (GRF) components, postural stability, and vertical jump performance in Taekwondo athletes. Method: Ten Taekwondo athletes (5 men, 5 women; mean age, $22.30{\pm}2.62years$; mean height, $174.21{\pm}9.20cm$; mean body weight, $67.28{\pm}12.56kg$) participated in this study. Fatigue was induced by a short period of strenuous exercise performed on a motorized treadmill. The analyzed variables included vertical jump performance, static stability (mediolateral [ML], center of pressure [COP], anteroposterior [AP] COP, ${\Delta}COPx$, ${\Delta}COPy$, and COP area), postural stability index values (ML stability index [MLSI], AP stability index [APSI], vertical stability index [VSI], dynamic postural stability index [DPSI]), and GRF components (ML force, AP force, peak vertical force [PVF], and loading rate). To analyze the variables measured in this study, PASW version 22.0 was used to calculate the mean and standard deviation, while a paired t-test was used to evaluate the pre- versus post-fatigue results. Pearson's correlation coefficients among variables were also analyzed. The statistical significance level was set at ${\alpha}$ = .05. Results: Vertical jump performance decreased significantly after the induction of fatigue, while AP COP, ${\Delta}COPx$, COP area, APSI, VSI, and DPSI increased significantly. PVF and loading rate increased significantly after the induction of fatigue, while the postural stability variables (AP COP, ${\Delta}COPy$, COP area, APSI, VSI, DPSI) were similarly correlated with GRF components (PVF, loading rate) after fatigue was achieved (r = .600, $R^2$ = 37%). Conclusion: These results suggest that the induction of fatigue can decrease postural stability and exercise performance of Taekwondo athletes during training and competition sessions.

Membrane Structural Design and Construction by Using Glued Laminated Timber (집성재를 이용한 막구조물의 시공 및 설계)

  • Hwang, Bu-Jin;Ko, Kwang-Woong
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.49-52
    • /
    • 2008
  • Structural Wood is developed by purpose to make efficient use of wood resources. The biggest advantage of structural wood is stable as strength is high than wood product that is used by structure in existing. Order manufacture according to design details is available. It Is used to main structure elements to large spatial structure. Structure wood kind utilizes Glulam, prefabricated wood I-joists and laminated veneer lumber(LVL) and so on. Structural Design and construction of Open-air Stage Roof Structure is described in the presented paper. Architectural roof materials is used to PVF/PFLT membrane. Column and diagonal members is used to steel members(SS400), and Cantilever beam is used to Glulam assembled with different Grade laminations(10S-28B).

  • PDF

Fire Combustion Characteristics of Membrane Materials According to the Height and Heat Generation Rate (막재료의 설치높이와 발열량에 따른 화재연소특성)

  • Cho, Seung-Ho;Choi, Kwang-Ho;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.84-90
    • /
    • 2016
  • Various form of membrane structures are being built in recent years. However, there is no appropriate fire proofing standards which can be applied each specific membrane structures. Therefore, existing fire protection standards are in establishment state and they need to be revised. In the current study, commonly used membrane materials(ETFE, PVF, PTFE) has been selected to investigate its fire resistance behavior with the change of fire duration time. In addition to this, heat generation rate of the membrane materials in correlation with the height of membrane has been investigated. And these fire combustion characteristics of membrane materials can be used in future practice for the fire prevention regulations of membrane structures.

Test on the Mechanical Characteristics of Glass Fiber Membrane (유리섬유 막재의 역학적 특성에 관한 시험)

  • Park, Kang-Geun;Yoon, Sung-Kee
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.2
    • /
    • pp.55-62
    • /
    • 2008
  • Membrane structures are now used in various ways throughout the world with the merits of free shape, lightness, durability, sunlight transmittance and homogeneous material. The development of new membrane material opened up new possibility for the design of new building structures. Recently it was mainly used PVC, PVF, PVDF, PTFE, ETFE membrane for using the roofing material of membrane structures. Some problems of membrane materials have fire proofing, lack of strength, self cleaning capacity, tear resistance, durability, heat insulation, sound insulation and elasticity. For the solution of this problems, it will be tested the mechanical properties of membrane material about tensile strength, tearing resistance, etc.

  • PDF

Basic Test on the Mechanical Characteristics of Polyester Membrane (폴리에스터 막재의 역학적 특성에 관한 기초시험)

  • Park, Kang-Geun;Yoon, Seoung-Hyun;Lee, Jang-Bok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • Membrane structures are now used in various ways throughout the world with the merits of free shape, lightness, durability, sunlight transmittance and homogeneous material. The development of new membrane material opened up new possibility for the design of new building structures. Recently it was mainly used PVC, PVF, PVDF, PTFE, ETFE membrane for using the roofing material of membrane structures. Some problems of architectural membrane have fire proofing, lack of strength, tear resistance, durability and elasticity. For the estimation of this problems, it will be tested the basic mechanical properties of membrane material about tensile strength, tearing resistance and repeated loading behavior. Elastic modulus is 337.30~1257.63N/$mm^2$, and strain is 17.90~26.91%.

  • PDF

Relationship between Ground Reaction Force and Attack Time According to the Position of Hand Segments during Counter Attack in Kendo

  • Hyun, Seung Hyun;Jin, HyeonSeong;Ryew, Che Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Objective: The purpose of this study was to analyze the relationship between ground reaction force (GRF) and attack time according to the position of hand segments during counter attack in Kendo. Method: The participants consisted of 10 kendo athletes (mean age: $21.50{\pm}1.95yr$, mean height: $175.58{\pm}5.02cm$, mean body weight: $70.96{\pm}9.47kg$) who performed standard head strikes (A) and counter attack with a preferred hand position of +10 cm (B), 0 cm (C), and -10 cm (D). One force-plate (AMTI-OR-7., USA) was used to collect GRF data at a sample rate of 1,000 Hz. The variables analyzed were the attack time, medial-lateral GRF, anterior-posterior GRF (AP GRF), peak vertical force (PVF), and loading rate. Results: The total attack time was shorter in types A and C than in types C and D. The AP GRF, PVF, and loading rate had significantly higher forces in types C and D than in types A and C. The attack time (bilateral and unilateral leg support and total) was positively correlated with the GRF variables (vertical GRF and loading rate) during the counter attack in Kendo (r = 0.779 [$R^2=0.607$], p < 0.001). Conclusion: The positions of the hand segments can be changed by various conditions of the opponent in Kendo competitions; however, the position preferred by an individual can promote the successful ratio of the counter attack.

Flame Resistance Performance of Glass Fiber and Polyester Fiber Architectural Membranes (건축용 유리섬유 및 폴리에스테르섬유 막재의 난연특성)

  • Kim, JiHyeon;Song, Hun
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.17-23
    • /
    • 2016
  • Membrane structures can be used to create diverse lightweight structural forms using ductile membranes made of coated fabric. Using membrane structures, it is possible to construct large covered spaces relatively quickly and economically, and hence, they are being applied within various applications. The structures are light-weight, transparent, flexible in their application, economical and easy to maintain, and as such, their usage is being expanded. However, despite their prevalence, the standard for membrane material performance in terms of fire safety is still inadequate, and the development of membrane materials with excellent flame resistance performance is being demanded. This study determined flame resistance performance of architectural membranes, including PTFE, PVDF, PVF and ETFE film membranes, through flammability testing and incombustibility testing.

Efficacy of carprofen administration and rehabilitative intervention in a dog with unilateral forelimb lameness (편측 앞다리 파행이 있는 개에서 카프로펜 투여와 재활 중재의 효과)

  • Shin-Ho Lee;Sujin Kim;Jae-Hyeon Cho
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.3
    • /
    • pp.185-191
    • /
    • 2024
  • This case report examines the efficacy of carprofen and rehabilitation therapy in a 7-year-old, 4.5 kg, spayed Poodle with unilateral forelimb lameness. Gait analysis assessed kinetic parameters such as peak vertical force (PVF), vertical impulse (VI), symmetry index (SI), and body load distribution (BLD) before and after treatment. The differences between the left and right forelimbs were recorded. Before intervention, the PVF differences between the forelimbs were -4.00% during walking and 40.00% during trotting. Two weeks post-intervention, these improved to 8.33% and 27.67%, further reducing to 6.33% and 18.00% after four weeks. VI differences also improved, with initial values of -0.67 N∙s during walking and -1.3 N∙s during trotting decreasing to -0.03 N∙s and -0.87 N∙s, respectively. SI increased from 6.23% to 11.87% during walking, while it decreased from 33.63% to 14.73% during trotting. BLD differences reduced from -1.17 cm2 and -7.13 cm2 to 0.23 cm2 and -2.17 cm2, respectively, after four weeks. These results suggest that a combination of carprofen administration and rehabilitative intervention can effectively reduce lameness and improve symmetry in dogs with unilateral forelimb lameness, as evidenced by improvements in key gait parameters over the treatment period.

A Fire Resistance Property Study of Architectural Fabric using Cone Calorimeter (콘칼로리미터를 이용한 건축용 막재의 내화 특성 연구)

  • Kim, Ji-Hyeon;Shin, Hyeon-Uk;Song, Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.158-159
    • /
    • 2015
  • Architectural fabrics are now used in membrane structure with the merits of free shape, lightness and opened up new possibility for the design of new building structures. Recently PVC, PVF, PVDF, PTFE coated fabric for using the membrane structures. However, clear standards for the design and construction is not exist because of the lack of Architectural fabric research. In this paper, Flammable properties of PVDF, PTFE coated fabrics are obtained through the Flammability test using the Cone Calorimeter. Based on these results, identify the fire resistance property of the Architectural fabric.

  • PDF