• Title/Summary/Keyword: PVC-FRP

Search Result 10, Processing Time 0.02 seconds

Stress-strain model of weak PVC-FRP confined concrete column and strong RC ring beam joint under eccentric compression

  • Yu, Feng;Zhang, Nannan;Fang, Yuan;Liu, Jie;Xiang, Guosheng
    • Steel and Composite Structures
    • /
    • v.35 no.1
    • /
    • pp.13-27
    • /
    • 2020
  • To investigate the stress-strain relation of PVC-FRP Confined Concrete (PFCC) column with RC ring beam joint subjected to eccentric compression, the experiment of 13 joint specimens, which were designed with principle of "strong joint and weak column", were presented. Several variable parameters, such as reinforcement ratio, width and height of ring beam, FRP strips spacing and eccentricity, were considered. The specimens were eventually damaged by the crushing of concrete, the fracture of PVC tube and several FRP strips. With the FRP strips spacing or eccentricity increased, the ultimate carrying capacity of specimens declined. The strain of FRP strips and axial strain of PVC tube decreased as FRP strips spacing decreased. The decrease of eccentricity would slow down the development of strain of FRP strips and axial strain of PVC tube. The slope of stress-strain curve of PFCC column decreased as FRP strips spacing or eccentricity increased. The ultimate strain of PFCC column reduced as FRP strips spacing increased, while the effect of eccentricity on the ultimate strain of PFCC was not distinct. Considering the influence of eccentricity on the stress-strain relation, a modified stress-strain model for conveniently predicting the weak PFCC column and strong RC ring beam joint under eccentric compression was proposed and it was in good agreement with the experimental data.

Experimental study on bearing capacity of PFCC column-RC beam joint reinforced with CST

  • Ping Wu;Dongang Li;Feng Yu;Yuan Fang;Guosheng Xiang;Zilong Li
    • Steel and Composite Structures
    • /
    • v.47 no.1
    • /
    • pp.19-36
    • /
    • 2023
  • An experimental study of eleven PVC-FRP Confined Concrete (PFCC) column-Reinforced Concrete (RC) beam joints reinforced with Core Steel Tube (CST) under axial compression is carried out. All specimens are designed in accordance with the principle of "weak column and strong joint". The influences of FRP strips spacing, length and steel ratio of CST, height and stirrup ratio of joint on mechanical behavior are investigated. As the design anticipated, all specimens are destroyed by column failure. The failure mode of PFCC column-RC beam joint reinforced with CST is the yielding of longitudinal steel bars, CST and stirrups of column as well as the fracture of FRP strips and PVC tube. The ultimate bearing capacity decreases as FRP strips spacing or joint height increases. The effects of other three studied parameters on ultimate bearing capacity are not obvious. The strain development rules of longitudinal steel bars, PVC tube, FRP strips, column stirrups and CST are revealed. The effects of various studied parameters on stiffness are also examined. Additionally, an influence coefficient of joint height is introduced based on the regression analysis of test data, a theoretical formula for predicting bearing capacity is proposed and it agrees well with test data.

PVC and POM gripping mechanisms for tension testing of FRP bars

  • Basaran, Bogachan;Yaka, Harun;Kalkan, Ilker
    • Structural Engineering and Mechanics
    • /
    • v.77 no.1
    • /
    • pp.75-87
    • /
    • 2021
  • The present study pertains to the introduction of two new types of grip adaptor for universal testing machines, namely Polyvinyl Chloride (PVC) and Polyoxymethylene (POM) grip adaptors, and their application to tension testing of FRP bars with different fiber and surface finish types. The tabs are connected to the FRP bar sample with the help of mechanical anchors, i.e. bolts. These new adaptors offer vital superiorities over the existing end tab designs (anchors with filling material or mechanical anchorage), including the reduction in the time and labor for production, reusability and the mild nature, i.e. low hardness of the tab material, which retards and even prevents peeling and crushing in the gripping regions of an FRP sample. The methods were successfully applied to FRP bars with different types of fiber (CFRP, GFRP and BFRP) and different types of surface texture (ribbed, wrapped, sand-coated and wound). The test results indicated that the both types of end caps prevented slip of the bar, crushing and peeling in the gripping zone. The mechanical properties from the material tests with the new caps were in perfect agreement with the ones from the material tests with steel tubular caps.

A Fire Risk Assessment of Substrate for Fire Resistant Painted (난연도료를 도장한 바탕재의 화재 위험성평가)

  • Park Young-Keun;Lee Doo-Hyung;Yoon Myung-O;Hyun Seong-Ho
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.51-58
    • /
    • 2005
  • In this paper, The experimental materials of painted fire resistant paint on substrate, FRP, PVC, AL and stainless steel that fire resistant paint developed newly were evaluated as the hazard elements : the fire resistibility of the materials, fire spread test of flame, the oxygen index, flammability, the smoke density. the toxicity index from it when it burned. As a result of the experiments, the AL and the stainless steel were passed of fire resistant class 1, the FRP, the AL, and the stainless steel were ignited of fire spread test of flame, all the experimental materials showed about $50\%$ of oxygen index, V-0 of flammability, and 43-338 of maximum smoke density at flaming mode used smoke density chamber. Also, they showed that the toxicity index of combustion products were 0.57-1.12.

An analytical model for PVC-FRP confined reinforced concrete columns under low cyclic loading

  • Fang, Yuan;Yu, Feng;Chen, Anchun;Wang, Shilong;Xu, Guoshi
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.179-196
    • /
    • 2021
  • Experimental investigations on the seismic behaviors of the PVC-FRP Confined Reinforced Concrete (PFCRC) columns under low cyclic loading are carried out and two variable parameters including CFRP strips spacing and axial compression ratio are considered. The PFCRC column finally fails by bending and is characterized by the crushing of concrete and yielding of the longitudinal reinforcement, and the column with a high axial compression ratio is also accompanied by the cracking of the PVC tube and the fracture of CFRP strips. The hysteretic curves and skeleton curves of the columns are obtained from the experimental data. With the increase of axial compression ratio, the stiffness degradation rate accelerates and the ductility decreases. With the decrease of CFRP strips spacing, the unloading sections of the skeleton curves become steep and the ductility reduces significantly. On the basis of fiber model method, a numerical analysis approach for predicting the skeleton curves of the PFCRC columns is developed. Additionally, a simplified skeleton curve including the elastic stage, strengthening stage and unloading stage is suggested depending on the geometric drawing method. Moreover, the loading and unloading rules of the PFCRC columns are revealed by analyzing the features of the skeleton curves. The quantitative expressions that are used to predict the unloading stiffness of the specimens in each stage are proposed. Eventually, an analytical model for the PFCRC columns under low cyclic loading is established and it agrees well with test data.

Comparative Study of Metallic and Non-metallic Stiffened Plates in Marine Structures

  • Jeong, Han-Koo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.6
    • /
    • pp.715-726
    • /
    • 2010
  • In this paper, a comparative study of metallic and non-metallic stiffened plates under a lateral pressure load is performed using conventional statistically determinate and SQP(Sequential Quadratic Programming) optimisation approaches. Initially, a metallic flat-bar stiffened plate is exemplified from the superstructure of a marine vessel and, subsequently, its structural topology is varied as hat-section stiffened FRP(Fibre Reinforced Plastics) single skin plates and monocoque FRP sandwich plates having a PVC foam core. These proposed structural alternatives are analysed using elastic closed-form solutions and SQP optimisation method under stress and deflection limits obtained from practice to calculate and optimise geometry dimensions and weights. Results obtained from the comparative study provide useful information for marine designers especially at the preliminary design stage where various building materials and structural configurations are dealt with.

Axial behavior of square CFST encased seawater sea-sand concrete filled PVC/GFRP tube columns

  • Rong Su;Xian Li;Ziwei Li
    • Steel and Composite Structures
    • /
    • v.47 no.6
    • /
    • pp.781-794
    • /
    • 2023
  • In order to directly apply seawater and sea sand in construction without desalination, a type of square concrete-filled steel tube (CFST) encased with prefabricated seawater sea-sand concrete filled Polyvinyl Chloride (PVC)/Glass Fiber Reinforced Polymer (GFRP) tube column was proposed. Twenty short columns were tested under uniaxial loads, and the test parameters included inner tube types, seawater sea-sand concrete replacement ratios, concrete strength, the wrapping area of Carbon Fiber Reinforced Polymer (CFRP) strips and the thickness of GFRP tube. The effects of the parameters on failure modes, loading capacity, ductility and strain responses were discussed. All the tested specimens failed with serious buckling of the steel tubes and fracture of the inner tubes. The specimens had good residual bearing capacity corresponding to 64% to 88.9% of the peak capacity. The inner GFRP tubes and PVC tubes wrapped by CFRP strips provided stronger confinement to the core concrete, and were good choices for the proposed columns. Moreover, an analytical model for the composite column with different inner tube types was proposed.

Risk of Smoke Occurring in the Combustion of Plastics (플라스틱의 연소 시 발생하는 연기 위험성에 관한 연구)

  • You, Jisun;Chung, Yeong-jin
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • In this study, the combustibility of five types of plastic plates, fiber reinforced plastic (FRP), polystyrene (PS), polycarbonate (PC), polypropylene (PP), and polyvinyl chloride (PVC), were tested using a cone calorimeter (ISO 5660). The PVC plate showed a $44.65kW/m^2$ lower peak heat release rate (HRR) and a $30.97kW/m^2$ lower maximum average rate of heat emission than the other four types of plastics, whereas the PS plate showed a $773.44kW/m^2$ higher peak HRR and $399.14kW/m^2$ higher maximum average rate of heat emission. The PC plate and PS plate showed the highest HRR by a maximum of 3.88 times in $CO_{mean}$ yields, while the PS pate and PP plate showed the highest HRR by a maximum 4.88 times in $CO_{2mean}$ yields. In addition, the smoke performance index (SPI) of the PS plate decreased by 74.81%~95.99%; the smoke growth index (SGI) increased to 76%~300%; the smoke intensity (SI) also increased to 917.73% ~ 9607.57%, and the danger of smoke increased. The PS plate was found to have the highest risk of life damage due to smoke on the thermal and smoke sides.

A study on combustion gas toxicity of polymeric materials using FTIR gas analysis (FTIR 가스분석에 의한 고분자재료의 연소가스독성 평가)

  • Lee, Doo-Hyung;Kong, Young-Kun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.4 s.19
    • /
    • pp.79-84
    • /
    • 2005
  • When polymeric materials are exposed to fire condition, a lot of heat and toxic gases evolved and cause damage to property and human being. Especially toxic gases are major hazard to life safety. This study FTIR(Fourier Transform Infrared) spectrometer analysis was performaed to etermine the gas analysis and the concentration of gases evolved from PVC, FRP, SMC and Ureathane foam using ASTM E 1678 fire model. And FED toxicity index calculated from FTIR data also presented. By the comparison of animal test adopted in KS F 2271 and FTIR gas analysis method, FTIR gas analysis method can replace current animal toxicity test and produce precise and quantitative combustion gas data.

Resources of Polymer Wastes produced from Electrical Industry (전력산업분야에서 배출되는 폴리머 절연 폐기물의 자원화)

  • Chun, Sung-Nam;Park, Chul-Bae;Chu, Cheol-Min
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.58-60
    • /
    • 2008
  • 발전소에서 만들어진 전력을 소비자까지 수송하는 송변전변 및 배전설비를 주 대상으로 하는 전력계통 설비의 운영에는 전력의 수송과 이를 위해 설치되는 각종 기자재로부터 인체 및 재산의 안전을 확보하기 위해 많은 종류의 절연재를 사용하고 있다. 지금까지 전력분야에서 사용되어 온 절연재는 자기재(porcelain)가 주종을 이루어 왔으나 재료기술의 발달과 함께 폴리머 절연재료들이 속속 개발되면서 자기재에 비해 가격 및 시공성 등에서 이점이 많은 폴리머 절연재가 자기재를 대체하고 있다. 그러나 폴리머 절연재료는 기들의 재질 및 사용 환경 등에 따라 일정 수명을 가지는 것으로 나타나 수명종기에 이르면 폐기물로 배출되게 된다. 전력산업 중 배전분야에서는 2007년 구매한 기자재를 기준으로 연간 13만연 톤의 전력폐기물이 발생될것으로 예측되었으며 이들은 PE, XLPE, FRP, PVC, EPDM, Silicone 등 유기성분이 약 40%, Cu, Al, 철 등 금속과 무기성분이 약 60% 인 것으로 조사되었다. 그러나 전선 및 케이블류를 제외한 기자재를 대상으로 한 분석에서는 유기성분의 함량이 90%에 이르며 이들은 석유화학공업의 원료로부터 만들어지는 특성상 높은 에너지를 함유하는 것으로 나타난 바, 이들을 적정하게 처리하는 방안의 확보는 폐기물의 처리 외에 폐기물로부터 에너지를 회수하여 자원화하는 것이 가능한 것으로 보여진다.

  • PDF