An analytical model for PVC-FRP confined reinforced concrete columns under low cyclic loading |
Fang, Yuan
(Department of Civil Engineering and Architecture, Anhui University of Technology)
Yu, Feng (Department of Civil Engineering and Architecture, Anhui University of Technology) Chen, Anchun (Department of Civil Engineering and Architecture, Anhui University of Technology) Wang, Shilong (Department of Civil Engineering and Architecture, Anhui University of Technology) Xu, Guoshi (Department of Civil Engineering and Architecture, Anhui University of Technology) |
1 | Realfonzo, R. and Napoli, A. (2012), "Results from cyclic tests on high aspect ratio RC columns strengthened with FRP systems", Constr. Build. Mater., 37, 606-620. https://doi.org/10.1016/j.conbuildmat.2012.07.065 DOI |
2 | Rodrigues, H., Furtado, A. and Arede, A. (2017), "Experimental evaluation of energy dissipation and viscous damping of repaired and strengthened RC columns with CFRP jacketing under biaxial load", Eng. Struct., 145, 162-175. https://doi.org/10.1016/j.engstruct.2017.05.021 DOI |
3 | Rodrigues, H., Romão, X., Andrade-Campos, A., Varum, H., Arede, A. and Costa, A.G. (2012), "Simplified hysteretic model for the representation of the biaxial bending response of RC columns", Eng. Struct, 44(6), 146-158. https://doi.org/10.1016/j.engstruct.2012.05.050 DOI |
4 | Sajedi, F. and Shariati, M. (2019), "Behavior study of NC and HSC RCCs confined by GRP casing and CFRP wrapping", Steel. Compose. Struct., 30(5), 417-432.https://doi.org/10.12989/scs.2019.30.5.417 DOI |
5 | Shao, Y.T. and Mirmiran, A. (2004), "Nonlinear cyclic response of laminated glass FRP tubes filled with concrete", Compos. Struct, 65(1), 91-101. https://doi.org/10.1016/j.compstruct.2003.10.009 DOI |
6 | Skalomenos, K.A., Hatzigeorgiou, G.D. and Beskos, D.E. (2014), "Parameter identification of three hysteretic models for the simulation of the response of CFT columns to cyclic loading", Eng. Struct, 61, 44-60. https://doi.org/10.1016/j.engstruct.2014.01.006 DOI |
7 | Folkman, S. (2014), "Validation of the long life of PVC pipes", Proceedings of the 17th Plastic Pipes Conference PPXVII, Chicago; Illinois, USA . |
8 | Zhang, B., Teng, J.G. and Yu, T. (2015), "Experimental behavior of hybrid FRP-concrete-steel double-skin tubular columns under combined axial compression and cyclic lateral loading", Eng. Struct, 99, 214-231. https://doi.org/10.1016/j.engstruct.2015.05.002. DOI |
9 | Toutanji, H.A. and Saafifi, M. (2001), "Durability studies on concrete columns encased in PVC-FRP composite tubes", Compos. Struct, 54, 27-35. https://doi.org/10.1016/S0263-8223(01)00067-8 DOI |
10 | Umais, Khan, Al-Osta, M.A. and A. Ibrahim, (2017), "Modeling shear behavior of reinforced concrete beams strengthened with externally bonded CFRP sheets", Struct. Eng. Mech., 61(1), 125-142. https://doi.org/10.12989/sem.2017.61.1.125. DOI |
11 | Zhao, J. and Dun, H. (2014), "A restoring force model for steel fiber reinforced concrete shear walls", Eng. Struct., 75, 469-476. https://doi.org/10.1016/j.engstruct.2014.06.013. DOI |
12 | GB/T 50081- 2002 (2002), Standard for test method of mechanical properties on ordinary the concrete strength of the concrete, National Standards of People's Republic of China. |
13 | Wang, K., Lu, X.F., Yuan, S.F., Cao, D.F. and Chen, Z.X. (2017), "Analysis on hysteretic behavior of composite frames with concrete-encased CFST columns", J. Constr. Steel Res., 135, 176-186. https://doi.org/10.1016/j.jcsr.2017.03.011. DOI |
14 | Gao, C., Huang, L., Yan, L.B., Jin, R.Y. and Kasal, B. (2019), "Strength and ductility improvement of recycled aggregate concrete by polyester FRP-PVC tube confinement", Compos. Part B, 162, 178-197. https://doi.org/10.1016/j.compositesb.2018.10.102 DOI |
15 | GB/T 3354 - 2014 (2014), Test method for tensile properties of orientational fiber reinforced polymer matrix materials, National Standards of People's Republic of China. |
16 | GB/T 8804.1 - 2003 (2003), Thermoplastic pipes - determination of tensile properties. National Standards of People's Republic of China. |
17 | Han, L.H., Tao, Z., Liao, F.Y. and Xu, Y. (2010), "Tests on cyclic performance of FRP-concrete-steel double-skin tubular columns", Thin-Walled Struct, 48, 430-439. https://doi.org/10.1016/j.tws.2010.01.007 DOI |
18 | GB/T228.1 - 2010 (2010), Metallic materials - Tensile testing - Part 1: Method of test at room temperature, National Standards of People's Republic of China. |
19 | Gong, F. and Maekawa, K. (2018), "Multi-scale simulation of freeze-thaw damage to RC column and its restoring force characteristics", Eng. Struct., 156, 522-536. https://doi.org/10.1016/j.engstruct.2017.11.066 DOI |
20 | Hamid, S., Mohd, Z.J. and Shariati, M. (2011), "Numerical investigation on exterior reinforced concrete Beam-Column joint strengthened by composite fiber reinforced polymer (CFRP)", Int. J. Phys. Sci., 6(28), 6572-6579. https://doi.org/10.5897/IJPS11.1225 DOI |
21 | Youssf, O., Hassanli, R. and Mills, J.E. (2017), "Mechanical performance of FRP-confined and unconfined crumb rubber concrete containing high rubber content", J. Struct. Eng., 11, 115-126. https://doi.org/10.1016/j.jobe.2017.04.011 DOI |
22 | Xie, Q., Sinaei, H., Shariati, M., Khorami, M., Mohamad, E.T. and Bui, D.T. (2019), "An experimental study on the effect of CFRP on behavior of reinforce concrete beam column connections", Steel. Compose. Struct., 30(5), 433-441. https://doi.org/10.12989/scs.2019.30.5.433 DOI |
23 | Yang, S.Y., Song, X.B., Jia, H.X., Chen, X. and Liu, X.L. (2016), "Experimental research on hysteretic behaviors of corroded reinforced concrete columns with different maximum amounts of corrosion of rebar", Constr. Build. Mater, 121, 319-327. https://doi.org/10.1016/j.conbuildmat.2016.06.002 DOI |
24 | Youm, K.S., Cho, J.Y., Lee, Y.H. and Kim, J.J. (2013), "Seismic performance of modular columns made of concrete filled FRP tubes", Eng. Struct., 57(57), 37-50. https://doi.org/10.1016/j.engstruct.2013.09.001. DOI |
25 | Yu, F. (2007), "Experimental study and theoretical analysis of mechanical properties of PVC-FRP pipe concrete columns", Ph.D. Dissertation, Xi'an University of Architecture and Technology, Xian, China. |
26 | Yu, F. and Niu, D.T. (2010), "Stress-strain model of PVC-FRP confined concrete column subjected to axial compression", Int. J. Phys. Sci., 5(15), 2304-2309. |
27 | Yu, F. and Niu, D.T. (2016), "Experimental study on axial behavior of PVC-CFRP confined concrete column under alkaline environment", J. Basic Sci. Eng., 24, 573-581. https://doi.org/10.16058/j.issn.1005-0930.2016.03.014 DOI |
28 | Kocak, A. (2014), "Earthquake performance of FRP retrofitting of short columns around band-type windows", Struct. Eng. Mech., 53(1), 1-16. https://doi.org/10.12989/sem.2014.53.1.001 DOI |
29 | JGJ/T 101 - 2015 (2015), Specification for seismic test of buildings. National Standards of People's Republic of China. |
30 | Jiang, S.F., Wu, Z.L., Wu, Z.Q. and Yu, B. (2014), "Experimentalstudy on reinforced concrete columns confined by FRP-PVC tubes under reversed loading", J. Build. Struct., 35, 111-118. https://doi.org/10.14006/j.jzjgxb.2014.02.016 DOI |
31 | Li, W. and Han, L.H. (2012), "Seismic performance of CFST column to steel beam joint with RC slab: Joint model", J. Constr. Steel Res., 73, 66-79. https://doi.org/10.1016/j.jcsr.2012.01.011 DOI |
32 | Burn, S., Davis, P. and Schiller, T. (2006), "Long-term performance prediction for PVC pipes", Report 91092F, American Water Works Association AWWARF; USA. |
33 | Liu, M.X. and Qian, J.R. (2009), "Moment-curvature relationship of FRP-concrete-steel double-skin tubular members", Front. Archit. Civ. Eng., 3(1), 25-31. https://doi.org/10.16511/j.cnki.qhdxxb.2007.12.020 DOI |
34 | Luo, Z.Y., Sinaei, H., Ibrahim, Z., Shariati, M., Jumaat, Z., Wakil, K., Pham B.T., Mohamad E.T. and Khorami, M. (2019), "Computational and experimental analysis of beam to column joints reinforced with CFRP plates", Steel. Compose. Struct., 30(3), 271-280. https://doi.org/10.12989/scs.2019.30.3.271 DOI |
35 | Bailey, C.G. and Yaqub, M. (2012), "Seismic strengthening of shear critical post-heated circular concrete columns wrapped with frp composite jackets", Compos. Struct., 94(3), 851-864. https://doi.org/10.1016/j.compstruct.2011.09.004 DOI |
36 | Campione, G., Miraglia, N. and Papia, M. (2004), "Strength and strain enhancements of concrete columns confined with FRP sheets", Struct. Eng. Mech., 18(6), 769-790. https://doi.org/10.12989/sem.2004.18.6.769 DOI |
37 | Yu, T., Hu, Y.M. and Teng, J.G. (2016), "Cyclic lateral response of FRP-confined circular concrete-filled steel tubular columns", J. Constr. Steel Res., 124, 12-22. https://doi.org/10.1016/j.jcsr.2016.05.006. DOI |
38 | Yu, F., Niu, D.T. (2013), "Experimental study on PVC-CFRP confined reinforced concrete short column under axial compression", J. Build. Struct., 34, 129-136. https://doi.org/10.14006/j.jzjgxb.2013.06.018 DOI |
39 | Yu, F., Xu, G.S., Niu, D.T. Cheng, A.C., Wu, P. and Kong, Z.Y. (2018), "Experimental study on PVC-CFRP confined concrete columns under low cyclic loading", Constr. Build. Mater., 177, 287-302. https://doi.org/10.1016/j.conbuildmat.2018.05.111 DOI |
40 | Yu, F., Zhang, N.N., Niu, D.T., Kong, Z.Y., Zhu, D.F., Wang, S.L. and Fang, Y. (2019), "Strain analysis of PVC-CFRP confined concrete column with ring beam joint under axial compression", Compos. Struct., 224, 111012. https://doi.org/10.1016/j.compstruct.2019.111012. DOI |
41 | Nanni, A. and Bradford, N.M. (1995), "FRP jacketed concrete under uniaxial compression", Constr. Build. Mater., 9(2), 115-124. https://doi.org/10.1016/0950-0618(95)00004-Y DOI |
42 | Ozbakkaloglu, T., Jian, C.L., Vincent, T. (2013), "FRP-confined concrete in circular sections: Review and assessment of stress-strain models", Eng. Struct., 49(2), 1068-1088. https://doi.org/10.1016/j.engstruct.2012.06.010 DOI |
43 | Pan, Y., Rui, G., Li, H.Y., Tang, H.Y. and Xu, L. (2017), "Study on stress-strain relation of concrete confined by CFRP under preload", Eng. Struct., 143, 52-63. https://doi.org/10.1016/j.engstruct.2017.04.004 DOI |
44 | Ding, F.X., Liu, J., Liu, X.M., Yu, Z.W. and Li, Y.S. (2018), "Experimental investigation on hysteretic behavior of simply supported steel-concrete composite beam", J. Constr. Steel Res., 144, 153-165. https://doi.org/10.1016/j.jcsr.2018.01.018 DOI |
45 | Ceravolo, R., Erlicher, S. and Fragonar, L.Z. (2013), "Comparison of restoring force models for the identification of structures with hysteresis and degradation", J. Sound. Vib., 332(26), 6982-6999. https://doi.org/10.1016/j.jsv.2013.08.019 DOI |
46 | Chan, C.W., Yu, T., Zhang, S.S., Chan, C.W., Yu, T., Zhang, S.S. and Xu, Q.F. (2019), "Compressive behaviour of FRP-confined rubber concrete", Constr. Build. Mater., 211, 416-426. https://doi.org/10.1016/j.conbuildmat.2019.03.211 DOI |
47 | Priestley, M.J.N., Seible, F. and Calvi, M. (1996), Seismic Design and Retrofit of Bridges, Wilev, New York, USA. |
48 | Chen, G.M., He, Y.H., Jiang, T. and Lin, C.J. (2016), "Behavior of CFRP-confined recycled aggregate concrete under axial compression", Constr. Build. Mater., 111, 85-97. https://doi.org/10.1016/j.conbuildmat.2016.01.054 DOI |
49 | Clough, R.W. and Johnston, S.B. (1966), "Effect of stiffness degradation on earthquake ductility requirements", Proceedings of 2nd Japan Earthquake Engineering Symposium, Tokyo, March. |
50 | Costa, A.C. and Costa, A.G. (1987), "Hysteretic model of force - Displacement relationships for seismic analysis of structures", National Laboratory for Civil Engineering, Lisbon, Spain. |
51 | Fakharifar, M. and Chen, G.D. (2016), "Compressive behavior of FRP-confined concrete-filled PVC tubular columns", Compos. Struct., 141, 91-109. https://doi.org/10.1016/j.compstruct.2016.01.004 DOI |
52 | Fakharifar, M. and Chen, G.D. (2017), "FRP-confined concrete filled PVC tubes: A new design concept for ductile column construction in seismic regions", Constr. Build. Mater., 130, 1-10. https://doi.org/10.1016/j.conbuildmat.2016.11.056 DOI |