• Title/Summary/Keyword: PULSE

Search Result 10,423, Processing Time 0.033 seconds

A study on The Pulse taking diagnostics of Nan Jing 1-23 Nan (난경(難經) 1-23난중(難中) 맥학조(脈學條)에 관한 연구(硏究))

  • Kim, Bup-Jin;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.131-154
    • /
    • 2000
  • Nan Jing(Difficult Classic), as a catechism, describes in detail and deeply the ideas in Nei Jing(Huangdi's Internal Classic). The description of Nan Jing is focused on basic theories including theories about some disease and is excellent in identification and analysis. The contents of Nan Jing are as follows: 1-23 Nan-pulse and pulse condition, 24~29 Nan-channels and collaterals, 30~47 Nan-viscera and bowels(Zang Fu organs), 48~61 Nan-disease, 62~68 Nan-acupuncture points, 69~91 Nan-acupuncture. Especially, diagnosis techniques in Nan Jing make 'Only method of cunkou pulse taking' that is a technique for feeling the pulse widely applied in these days in Oriental medicine clear. Thus, this book adjusts the theory of pulse and pulse condition given in 1~23 Nan of 'The Study of Nan Jing' in order to enhance an understanding about the theory of pulse and pulse condition. The text of 1~23 Nan about pulse lore centers on all pulse of human body interconnected each other and cunkou, both ends of the pulse, and contrasts regular pulse with irregular pulse. 1. 10 Nan describes the theory about five kinds of evils and hardness and softness, and unique pulse condition of each bowels. 2. 13 Nan explains that the relative difficulty of medical treatment is determined by the degree of balance or unbalance among three factors-colors, pulse and pulse condition, flesh shape. 3. 14 Nan divides pulse and pulse condition into slow pulse and rapid pulse, and explains separately abnormality, great loss of semen, death caused by slow pulse, and abnormality, great loss of semen, death caused by rapid pulse. 4. 15 Nan about taut pulse(弦), full pulse(鉤), floating pulse(毛), deep pulse(石脈) describes that pulse and pulse condition differs according to four seasons. Therefore, Nan Jing establishes clearly techniques of feeling the pulse in 'Only method of cunkou pulse taking(獨取寸口)' and advances the theory of Nei Jing. Futhermore, Nan Jing is more valuable in that it suggests unique theory different with Nei Jing.

  • PDF

The Development of pulse Diagnostic Apparatus enable to gain multi-information and it's Clinical Significance (다정보(多情報) 획득(獲得)을 위한 맥진기 개발과 임상적 의의)

  • Park, Y.B.;Lee, H.J.;Huh, W
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.499-504
    • /
    • 1995
  • Recently, there are deep and much concerns about the objective assessment of diagnosis in Oriental Medicine. Among them, pulse diagnostics is used for the quantitative device of diagnosis. The objective research of pulse diagnosis were mainly conducted by pulse wave. So it is important to gain multi-information for the quantification of pulse diagnosis. We report the development of pulse diagnostic apparatus enable to gain the multi-information, detect the pressure pulse wave in conku(寸口) area and obtain the gradient curve and original pulse wave simultaneously, and consider the pulse wave with the traditional pulse diagnosis at the same time.

  • PDF

Implementation of Radial Pulse Diagnosis System using Inyoung-Cheongu Comparison Method (인영.촌구 대비법을 이용한 맥 진단 시스템 구현)

  • Lee, Ho-Jae;Park, Young-Bae;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.73-80
    • /
    • 1993
  • This paper describes the implementation of a computerized radial pulse diagnosis by Elds of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diag nosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed It. Then, we have got the characteristic parameters of radial pulse wave and also quantified thats according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial Pulse diagnosis system and then we confirmed the PossibiliLy for realization of automatic radial Pulse diagnosis in korean traditional medicine.

  • PDF

A Pulse Power Supply for Metal Vapor Lasers (금속 증기 레이저용 펄스 전원 장치)

  • Cha Byung Heon;Lee Heung Ho;Jin Jeong Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.190-197
    • /
    • 2005
  • A reliable and compact pulse power supply using a thyratron and a magnetic pulse compression (MPC) circuit was developed for a metal vapor laser. The life time of the pulse power supply is expected to be much longer than that of a conventional thyratron-discharge type pulse power supply. A thyratron generated a long pulse of its conduction pulse width 500 ns and then it was compressed to less than 80 ns of its output voltage rise time by a three stage MPC circuit. This pulse power supply was applied to a laser plasma tube of 30 mm inner diameter and 1.5 m discharge length. It was operated several hundreds hours without any troubles.

A Study on Destruction Characteristics of BJT (Bipolar Junction Transistor) at Different Pulse Repetition Rate (다양한 펄스 반복률에서의 NPN BJT (Bipolar Junction Transistor)의 파괴 특성에 관한 연구)

  • Bang, Jeong-Ju;Huh, Chang-Su;Lee, Jong-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • This paper examines the destruction behavior of NPN BJT (bipolar junction transistor) by repetition pulse. The injected pulse has a rise time of 1 ns and the maximum peak voltage of 2 kV. Pulse was injected into the base of transistor. Transistor was destroyed, current flows even when the base power is turned off. Cause the destruction of the transistor is damaged by heat. Breakdown voltage of the transistor is 975 V at single pulse, and repetition pulse is 525~575 V. Pulse repetition rate increases, the DT (destruction threshold) is reduced. Pulse Repetition rate is high, level of transistor destruction is more serious.

A Peaking Switch to Generate a High Voltage Pulse of Sub-nanosecond Rise Time (서브 나노초 상승시간의 고전압 펄스 발생용 피킹 스위치)

  • Roh, Young-Su;Jin, Yun-Sik;Cho, Chu-Hyun;Lim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1300-1305
    • /
    • 2012
  • A triaxial Blumlein pulse forming line has been designed to generate a pulse whose voltage is ~300 kV, pulse duration is ~5 ns, and rise time is ~500 ps. It turns out, however, that the rise time of the pulse becomes much longer than 500 ps due to parasitic inductances and capacitances existing inside the system. A peaking switch has been developed to shorten the rise time of the pulse from Blumlein pulse forming line. In the peaking switch, a wedge-shaped dielectric material (MC 901 nylon) is employed to surround the electrode on the antenna side. This shape inhibits an abrupt change of the output impedance, thereby minimizing the reflection of the output pulse. Experimental results show that the peaking switch is capable of improving the rise time of the pulse at a level of 500 ps.

The philological study on the form of intermittent pulse(代脈) (대맥(代脈)의 체상(體狀)에 대한 문헌적(文獻的) 고찰(考察))

  • Kim, Jeong-Giu
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.1-12
    • /
    • 2010
  • The form of intermittent pulse(代脈) has three standards. The first is "The persistence of the pulse stop(止不能還)". This standard is extensively accepted to the medical scientists in every ages of after the . The second is "The replacement of the former pulses(更代)". This standard is very useful to explain the situations that the intermittent pulse(代脈) is regarded as a dead pulse(死脈). The third is "The regular inerval of the pulse stop(止有定數)". This standard is impractical and illogical to practical using of the intermittent pulse(代脈). The reason is misreading on the of Wang-Suk-Hwa(王淑和) and the inexact & expansive reproduction of medical men of the Myeong-Chung dynasty(明淸代).

Frequency-Modulated Pulse-Amplification Method for Reducing Pulse Shape Distortion

  • Jeong, Jihoon;Cho, Seryeyohan;Hwang, Seungjin;Yu, Tae Jun
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1637-1643
    • /
    • 2018
  • To reduce the laser pulse shape distortion accompanying the amplification process and achieve an intended output pulse shape in the Nd:YAG amplifier chain, we propose a frequency-modulated pulse-amplification method. Assuming carrier-frequency-modulated seed pulses, we numerically simulate the pulse amplification in an Nd:YAG amplifier chain where severe distortion occurs. For the calculation, we develop a modified Frantz-Nodvik equation, which enables two inputs with different carrier frequencies. The simulation results indicate that the temporal contrast of the seed pulse needed to obtain a flat output pulse shape is reduced by 16 - 25 dB when frequency modulation is applied.

Significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'The affected part of the pulse wave' ('맥상(脈狀)의 환측(患側)' 취혈(取穴)과 침(鍼) 치료(治療) 경과 확인 기준으로서의 촌구맥진(寸口脈診)의 의의(意義))

  • Sim, So-Hyun;Kang, Min-Jung;Kim, Jae-Kyu;Baek, Jin-Ung
    • Journal of Korean Medical classics
    • /
    • v.27 no.1
    • /
    • pp.47-56
    • /
    • 2014
  • Objective : The aim of this study is to find out the significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' based on the literature. Method : (1) The clear concepts of the 'unaffected part' and the 'affected part' were organized. (2) The relation between the pulse diagnosis and the acupuncture in Hwangjenaekyung was studied. (3) The indications of Mu acupuncture treatment(繆刺法) and Geo acupuncture treatment(巨刺法) in Hwangjenaekyung was studied. (4) The types and changes of pulse diagnosis in Hwangjenaekyung was studied, especially based on the relation between Sambuguhu pulse diagnosis(三部九候脈診) and Chongu pulse diagnosis(寸口脈診). (5) By synthesizing these results, the significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' was found. Result & Conclusion : 1. When the affected part and the unaffected part are defined, it is necessary to make clear that which one of next three definitions is used ; Firstly, 'the broad sense of definition of the affected part and the unaffected part of the symptom', which contains the pulse wave. Secondly, 'the narrow sense of definition of the affected part and the unaffected part of the symptom', without the pulse wave. And thirdly, 'the definition of the affected and the unaffected part of the pulse wave', which has the only independent standard of the pulse wave. 2. Geo acupuncture treatment(巨刺法) is an acupuncture treatment which means the needling on 'the affected part of the pulse wave' based on Sambuguhu pulse diagnosis (三部九候脈診), and Mu acupuncture treatment(繆刺法) is an acupuncture treatment which means the needling on 'the unaffected part of the symptom based on the narrow sense of the definition'. The range of the indications of Mu acupuncture treatment(繆刺法) and Geo acupuncture treatment(巨刺法) contains most of the diseases which contains Rakbyung(絡病), Kyungbyung(經病) and Ojangbyung(五臟病). 3. Chongu pulse diagnosis(寸口脈診) contains not only the range of the indications of Sambuguhu pulse diagnosis(三部九候脈診), but also most of the diseases. 4. From synthesizing these results of the study on the literature, we infer that Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' is significant.

Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System (카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Ha, Hyun Chul;Kim, Sung Joon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.