• 제목/요약/키워드: POSCO

검색결과 1,202건 처리시간 0.027초

Construction Process & Technologies Applied to Parc.1 Project

  • Hoi-soo, Seo;Jae-min, Baek
    • 국제초고층학회논문집
    • /
    • 제11권3호
    • /
    • pp.181-187
    • /
    • 2022
  • POSCO E&C has completed Parc.1 project successfully. The construction period was 42months, and 1.5 million workers were participated till completion. To meet schedule management and quality control, POSCO E&C has adopted a lot of technologies such as GPS measurement, 3D scanning, vibration control, stack effect control, column shortening control, etc

가파도 마이크로그리드에서의 풍력발전 연계를 위한 2MVA급 배터리 에너지 저장시스템(BESS) 적용 및 실증 (The Application and Verification of the 2MVA Battery Energy Storage System(BESS) with Wind-turbine in Micro-grid of Gapado, Jeju)

  • 김승모;오승진;이종학;김태형;권병기;안재민;진경민;최창호
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.303-311
    • /
    • 2014
  • This paper shows the test result of 2MVA BESS(Battery Energy Storage System) with wind-turbine in micro-grid of the Gapado. To implement of micro-grid with BESS, characteristics of generator and customer load in grid are considered. Also, to operate of 2-parallel PCU(Power Conversion Unit) in BESS, the droop control is adopted with operating mode of grid independent. Performances of BESS with wind-turbine were verified by analysis of power quality such as voltage harmonics, ratio of voltage and frequency regulation, and by measurement of waveform such as output voltage and current.

산학연관 협력네트워크를 활용한 강원도의 POSCO 유치 전략 (A Strategy for the Attraction of POSCO into Gangwon Province through the Collaborative Network of Industry-University Institute-Government)

  • 김인중;김석중;정성훈;김경환
    • 한국경제지리학회지
    • /
    • 제13권4호
    • /
    • pp.710-726
    • /
    • 2010
  • 이 논문의 목적은 산업발전을 위한 불리한 입지여건을 지닌 강원도가 산학연관 협력적 네트워크를 통하여 POSCO 를 유치한 전략을 고찰하는 데 있다. 그러나 최근 POSCO의 마그네슘 제련공장을 강릉에 유치하게 되면서 강원도의 산업 발전은 새로운 국면을 맞이하고 있다. 강원도의 POSCO 마그네슘 제련공장 유치의 성공 요인은 다음과 같다. 첫째, 지자체와 지방연구소, 투자 대상 기업의 기술연구소, 지역의 연관 기업이 상호 협력적으로 역할 분담, 둘째, 지자체와 투자대상 기업, 연구소의 상호 배려에 입각한 합리적인 제안을 통해 형성한 신뢰, 셋째, 기업에 대한 철저한 분석을 토대로 수립한 기업 유치 전략, 마지막으로, 전방산업의 수요시장의 확보 등을 들 수 있다.

  • PDF

사업장 자체측정기관 국내, 외 정도관리 참여 결과 (The Result of Quality Control in POSCO's Industrial Hygiene Laboratory)

  • 이영세;이송권;조기현;채종홍;김용래
    • 한국산업보건학회지
    • /
    • 제5권1호
    • /
    • pp.87-103
    • /
    • 1995
  • Since being granted permission for self-assessment of the work environment by the Department of Labor in 1992, POSCO's Industrial Hygiene Laboratory has participated in domestic and Foreign Quality Control Programs 8 times and has obtained remarkable results. It has made a lot of effort to be a proficient laboratory with the ability to observe and analyse environmental monitoring data. The summary of results is as follows: 1. POSCO's Industrial Hygiene Laboratory has received a "P(Proficient)" grade from the round 115 to round 119 of AIHA/NIOSH PAT Program for analysis of such metals as lead, cadmium, zinc, and chromium, and also has received a "P(Proficient)" grade from its round 119 of for organic solvent analysis, i,e,. Trichloroethylene(TCE), Carbon Tetr-achloride(CTC), 1,2-Dichloroethane(DCE), 1,1,1-Trichloroethane(MCM), Tetrachloroethylene (PCE), Chloroform(CFM), Benzene(BNZ), toluene(TOL), and O-xylene(OXY). 2. In the Quality Control Evaluation Program performed by the Industrial Health Research Institute,Korea Industrial Safety Corporation, POSCO has passed impressively in the3-metal analysis test for lead, cadmium, cupper, and in the 6 organic solvent analysis test for Benzene(BNZ), toluene(TOL), O-xylene(OXY), Trichloroethylene(TCE) and Methyl isobutyl keton(MIBK), n-Hexane with 2 standard deviations. These analytic techniques should be practically applied to various fields, and reliable results of environmental monitoring should be considered to improve the work environment and to keep workers from occupation related diseases.

  • PDF

주파수 조정용 에너지 저장 시스템의 변전소 적용 사례 (Case Study of ESS for Frequency Regulation in Substation)

  • 김태형;인동석;이종학;오승진;박영민;김동환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.421-422
    • /
    • 2016
  • 에너지 저장 시스템(ESS, Energy Storage System)은 주파수 조정을 통한 계통 전력품질 개선, 풍력(WT)발전, 태양광(PV)발전등과 같은 신재생 에너지의 출력안정화, 에너지 저장을 통한 에너지효율화 등의 분야에 적용되고 있다. 특히 주파수 조정(F/R, Frequency Regulation)을 위한 에너지 저장 시스템은 한전의 많은 투자를 통해 활발하게 이루어 지고 있으며, 전국 변전소에 설치되고 있다. 주파수 조정을 위한 에너지 저장 시스템은 주파수 상승 시 계통의 전력을 배터리에 충전하고, 주파수 하락 시에는 배터리에 저장된 에너지를 계통에 공급하여 주파수를 안정화 시키는 역할을 한다. 본 논문에서는 주파수 조정용 에너지 저장 시스템의 변전소 적용 사례에 대해 설명한다.

  • PDF

신재생에너지 연계형 MW급 ESS 설계 및 적용 (Design and Application of MW ESS Connected with Renewable Energy Source)

  • 허남억;인동석;권병기;이명준;권용효;홍종석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.95-96
    • /
    • 2014
  • 본 논문에서는 KEPCO가 신안 팔금도에서 진행 중인 능동배전망 운영실증 관련 2MW급 태양광발전 출력 안정화, 비상발전기, 계통 역률제어 등이 가능한 1MW/1MWh급 ESS의 설계 및 적용 결과를 기술하였다. 1MW/1MWh급 ESS는 외부환경으로부터 시스템 보호를 위해 공조설비 및 소방설비를 포함한 컨테이너에 ESS 관리 및 제어를 위한 PMS, 전력변환을 위한 PCS, 에너지 저장을 위한 배터리 시스템 등을 구성하였다. 또한 배전선로에 ESS 시스템 연계를 위해 변압기, 스위치기어 등의 계통연계설비를 함께 구성하였다. MW급 대용량 전력 시험설비를 이용하여 1MW/1MWh급 ESS의 다양한 기능 및 성능을 검증 후 신안 팔금도 현장에 적용하였다.

  • PDF

연료전지 전압 특성을 고려한 100kW 계통 연계 인버터 설계 (Design of 100kW Grid connected Inverter system for Fuel Cell Voltage characteristics)

  • 장주영;정우택;문상호;이정흠;손용훈;김민규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.142-143
    • /
    • 2012
  • EBOP(Electrical Balance of Plant)는 연료전지 출력인 DC 전원을 전력변환기술을 이용하여 계통 전원에 연계하는 계통 연계형 PCU 시스템이다. EBOP는 연료전지의 DC 전압 특성을 고려하여 인버터를 설계하여야 안정적인 전력 제어가 가능하다.

  • PDF

300kW급 발전용 연료전지 EBOP 시스템 개발 (Development of EBOP system for 300kW Fuel Cell Power Plant)

  • 양승철;권진만;임재관;정승수;김병섭;김재식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.122-123
    • /
    • 2012
  • 본 논문에서는 300kW급 EBOP(Electrical Balance of Plant)의 개발에 관한 내용을 설명하고 있다. EBOP는 연료전지 출력인 DC 전원을 전력변환기술을 이용하여 AC전원으로 변환하는 인버터 시스템이다. 포스코에너지에서는 300kW급 EBOP 시스템을 국제 규격에 준하는 시험을 통해 개발 완료하였고 실증단지에 적용하여 성능 검증을 하였다.

  • PDF

수냉형 인버터의 최대 효율 출력 추적 방법 (Maximum Efficiency Point Tracking Method for Liquid Cooled Inverter)

  • 김상현;김광섭;인동석;이종학;박영민;원선민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.538-539
    • /
    • 2012
  • 수냉형 인버터는 냉각 시 칠러를 사용하게 되는데 칠러는 입력 냉각수의 온도가 높을수록 열교환 효율이 높아져 소비전력이 감소한다. 하지만 인버터는 입력 냉각수의 온도가 높을수록 손실이 증가하게 되므로 수냉형 인버터는 각각의 출력 부하에 따라 최대 효율 점이 존재한다. 본 논문에서는 각각의 출력 부하에서 냉각수 온도 제어를 통해 수냉형 인버터의 최대 효율점을 추적하는 방법을 제안한다.

  • PDF