• Title/Summary/Keyword: PM10 Air Monitoring

Search Result 299, Processing Time 0.028 seconds

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

HEALTH RISK ASSESSMENT OF HOUSEHOLD EXPOSURE TO INDOOR RADON IN ASSOCIATION WITH THE DWELLING'S AGE

  • Shahrokhi, Amin;Shokraee, Forough;Reza, Ali;Rahimi, Hasn
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.155-161
    • /
    • 2015
  • Radon is a naturally occurring radioactive gas and a major indoor contribution of exposure to ionizing radiation in dwellings. $^{222}Rn$ is a health hazard gas what is responsible for thousand lung cancer deaths every year. In this study, indoor radon concentrations present in thirty representative houses in Mahallat city, Iran, were determined in order to estimate lung cancer risk associated with residential radon exposure. Long-term passive method, using CR-39, was used to measure the radon concentration. The results showed an association between the age of the dwellings and the indoor radon concentration that was found, in that the concentration of radon tended to increase as the age of the dwelling also increased. The indoor radon concentrations were calculated to be within the range of $23{\pm}2$ to $350{\pm}26Bq{\cdot}m^{-3}$, with an average of $158Bq{\cdot}m^{-3}$. The annual effective dose from inhaled radon and its decay products was calculated between $0.8{\pm}0.1$ and $12.3{\pm}0.9mSv{\cdot}y^{-1}$, with an average of $5.5mSv{\cdot}y^{-1}$. By taking into consideration the EPA recommendation and ICRP statement, the average annual risk of lung cancer from inhaled radon was calculated as 0.09%, 0.06%, 0.01%, and 0.03% for current smokers (CS), those who had ever smoked (ES), never smokers (NS) and the general population, respectively.

Implementation of Indoor Air Quality Monitoring System for Subway Stations (지하철 역사 공기질 모니터링 시스템의 구현)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.294-301
    • /
    • 2013
  • The particle matter concentrations in the subway stations should be monitored and controlled for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the cheap instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, a monitoring system is implemented to display and record the data of $PM_{10}$, $CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, CDMA M2M wireless communication method is applied.

Exploration of the Relationship between Traffic Volume and Air Quality Using Existing Monitoring Data (기존 교통량/대기질 모니터링 시스템 구축 자료를 활용한 상관성 분석)

  • Go, Jun-Ho;Choe, Yu-Jin;Lee, Se-Hui;Lee, Tae-Gyeong
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.5
    • /
    • pp.29-37
    • /
    • 2009
  • As the level of the ambient air quality becomes increasingly important, transportation management strategies tend to incorporate air quality standards into their measure of effectiveness. However, previous research efforts did not pay much attention to the empirical relationships between traffic volume and air quality, potentially due to the lack of data. With this background, this study investigates the relationship using Seoul's existing traffic and air quality monitoring data collected over the period of three years, from 2005 through 2007. In particular, those paired monitoring sites with a distance of less than one kilometer apart were utilized, targeting the emissions of CO, NO, $NO_2$, and $PM_{10}$. As a result, in general the data of two monitoring systems exhibited lower correlations, $NO_2$ showing a relatively higher correlation with traffic volumes than other emissions. In addition, it was found that the degree of correlation can be higher for the data obtained over the morning time period, 6am-9am, and the day after rainy days.

The Investigation and Comparison of Characteristics of Air Pollution for Cohort Study in Chungju with Industrial Cities (대조코호트 연구를 위한 충주의 대기오염현황 조사와 산단지역과의 비교)

  • Kim, Jae-Hoon;Wee, Seong-Seung;Nam, Sang-Hoon;An, Jung-Sun;Kim, Dae-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study was to investigate air quality in Chungju, Korea, using data obtained with a local air quality monitoring system. We have utilised cohort studies to investigate the relations between environmental pollution and the health of residents near large industrial complexes since 2004. This study analyzes the $O_3,\;NO_2,\;SO_2,\;CO\;and\;PM_{10}$ concentration in Chungju from 2002 to 2006. Air pollutants are closely related to the number of manufacturing facilities and cars, energy utilization and weather conditions. Generally, the diurnal concentration of air pollutants in Chungju reached the highest level in the morning (about$08:00{\sim}$) and early evening (about$19:00{\sim}$). On the other hand, the diurnal concentration of ozone as recorded gives the highest amount in late afternoon (about$16:00{\sim}$) and lowest in early morning (about$08:00{\sim}$). The concentration of air pollutants in Chungju was highest from winter to spring and lowest during the summer season. On the other hand, the monthly variation of ozone concentration was greatest in June and smallest in December. Also the, $PM_{10}$ concentration posted the highest record in April and the lowest during September. In general, this study analyzed air pollution changes in Chungju as well as in large scale industrial complex regions within Korea such as Ulsan, Pohang, Kwangyang, Sihwa Panwol and Gangneung in Korea. We compared the air quality of Chungju with those of these cites and found that air pollutants except for CO in Chungju was generally lower than large industrial complex regions.

Monitoring of Fine Particles and Particles-bound Mercury in Seongbuk-gu Area of Seoul Metropolitan City (서울 성북지역 미세먼지 및 미세먼지결합 수은의 모니터링)

  • Park, Eun-Jung;Lee, Jong-Wha;Kim, Dae-Seon;Park, Kwang-Sik
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.2 s.57
    • /
    • pp.185-188
    • /
    • 2007
  • PM10 and PM2.5 in ambient air were collected in Seongbuk-gu area of Seoul for one year, from April 2005 to February 2006, and the concentration of PM-bound mercury was monitored. The annual concentrations of particles were $66.4{\pm}43.2{\mu}g/m^3\;(47.6{\pm}19.1{\mu}g/m^3-106.1{\pm}78.0{\mu}g/m^3)$ in PM10 and $37.2{\pm}20.4{\mu}g/m^3\;(28.0{\pm}23.4{\mu}g/m^3{\sim}42.7{\pm}21.4{\mu}g/m^3)$ in PM2.5, which is about 56% of PM10 concentration. The annual average concentrations of mercury were $0.125{\pm}0.078ng/m^3\;in\;PM10\;and\;0.141{\pm}0.080ng/m^3$ in PM2.5, respectively. In April of Asian dust season in Korea, mercury showed the highest concentration in both PM10 and PM2.5.

A Study on Indoor Air Quality Monitoring System for Subway Stations (지하역사의 공기질 감시 시스템 구성에 관한 연구)

  • Lee, Byung-Seok;Hwang, Sun-Ju;Lee, Joon-Hwa;Kim, Gyu-Sik;Kim, Jo-Chun
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.48-50
    • /
    • 2009
  • This paper presents an IAQ(Indoor Air Quality) Monitoring System using equipments for measurement of fine Particle($PM1{\sim}PM10$), $CO_2$, VOCs(Volatile Organic Compounds), temperature and humidity for IAQ monitoring of subway station which millions of people use a day. The necessity of IAQ monitoring system is getting increased for more effective subway station monitoring in line with the recent government's regulation for IAQ is reinforcing. Subway Station is an unusual case. The structure of subway station is closed and complicated. Therefore when data of equipments are transferred, transmission error can happen occasionally. To prevent transmission error, an IAQ Monitoring System is needed the appropriate position and selection of equipments or sensor module. In addition IT(Information Technology) can be utilized like "WiBro(Wireless Broadband)" and "GateWay" for facilitate movement of data and construction of IAQ monitoring system of subway station.

  • PDF

Spatial and Temporal Assessment of Particulate Matter Using AOD Data from MODIS and Surface Measurements in the Ambient Air of Colombia

  • Luna, Marco Andres Guevara;Luna, Fredy Alejandro Guevara;Espinosa, Juan Felipe Mendez;Ceron, Luis Carlos Belalcazar
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.165-177
    • /
    • 2018
  • Particulate matter (PM) measurements are important in air quality, public health, epidemiological studies and decision making for short and long-term policies implementation. However, only few cities in the word have advance air quality-monitoring networks able to provide reliable information of PM leaves in the ambient air, trends and extent of the pollution. In Colombia, only major cities measure PM concentrations. Available measurements from Bogota, Medellin and Bucaramanga show that PM concentration are well above World Health Organization guidelines, but up to now levels and trends of PM in other cities and regions of the country are not well known. Satellite measurements serve as an alternative approach to study air quality in regions were surface measurements are not available. The aim of this study is to perform a spatial and temporal assessment of PM in the ambient air of Colombia. We used Aerosol optical depth (AOD) retrieved by the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite of NASA and surface measurements from the air quality networks of Bogota, Medellin and Bucaramanga. In a first step, we estimated the correlation between MODIS-AOD and monthly average surface measurements (2000 to 2015) from these three cities, obtaining correlation coefficient R values over 0.4 for the cities under study. After, we used AOD and $PM_{10}$ measurements to study the temporal evolution of PM in different cities and regions. Finally, we used AOD measurements to identify cities and regions with the highest AOD levels in Colombia. All the methods presented in this paper may serve as an example for other countries or regions to identify and prioritize locations that require the implementation of more accurate air quality measurements.

Monitoring of Trace Elements and Airborne Particulates in Taejon Areas using Neutron Activation Analysis and Gent Air Sampler (Gent Air Sampler와 중성자방사화분석을 이용한 대전지역의 대기분진중 미량금속 측정연구)

  • 정용삼;문종화;김선하;백성열;박광원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.330-332
    • /
    • 2000
  • 삶의 질 향상을 위한 쾌적한 대기환경의 관리 유지는 우리 모두의 관심사중의 하나이다. 호흡기관을 통해 인체내로 흡입되는 $PM_{10}$ 대기분진은 자연적이고 인위적인 발생원에 의해 다양한 미량원소들을 함유하고 있기 때문에 흔히 환경영향 평가를 위한 대기관측시료로 이용되고 있으며, 특히 $PM_{2.5}$ 분진의 질량농도(TSPM)나 원소의 농도가 높을 때 장.단기적으로 인체 보건에 큰 영향을 미치는 것으로 알려져 있다. (중략)

  • PDF

Two Dimensional Cluster Analysis of Air Quality by Time and Area (지역.시간별을 고려한 이차원 대기환경 군집 분석)

  • Wee, Seong-Seung;Kim, Jae-Hoon;Ahn, Chi-Kyung;Choi, Byong-Su;Kim, Dae-Seon
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.517-524
    • /
    • 2008
  • The purpose of this study was to investigate the characteristics of air quality using data from which obtain local air quality monitoring system for cohort study in Chungju, Korea. We analyzed the concentration data of $NO_2,\;SO_2$, and $PM_{10}$ in Chungju and industrial cities in 2006. We compared a industrial area with a cohort study area using by bicluster algorithm. In the case of $SO_2$, the rate of the cluster time was $10{\sim}60%$ and the cluster time number of two areas was similar. In the case of $NO_2$ and $PM_{10}$, the number of cluster time between a industrial area and cohort study area was clearly different.