• Title/Summary/Keyword: PM(particulate matter)

Search Result 820, Processing Time 0.032 seconds

Current Status of Ship Emissions and Reduction of Emissions According to RSZ in the Busan North Port (부산 북항에서의 선박 배출물질 현황과 선속제한에 의한 배출량 감소 연구)

  • Lee, Bo-Kyeong;Lee, Sang-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.572-580
    • /
    • 2019
  • In view of the numerous discussions on global environmental issues, policies have been implemented to limit emissions in the field of marine transport, which accounts for a major part of international trade. In this study, a ship's emissions were calculated by applying the engine load factor to determine the total quantity of emissions based on the ship's speed reduction. For ships entering and leaving the Busan North Port from 1 January to 31 December 2017, emissions were calculated and analyzed based on the ship's type and its speed in the reduced speed zone (RSZ), which was set to 20 nautical miles. The comparison of the total amount of emissions under all situations, such as cruising, maneuvering, and hotelling modes revealed that the vessels that generated the most emissions were container ships at 76.1 %, general cargo ships at 7.2 %, and passenger ships at 6.8 %. In the cruising and maneuvering modes, general cargo ships discharged a lesser amount of emission in comparison with passenger ships; however, in the hotelling mode, the general cargo ships discharged a larger amount of emission than passenger ships. The total emissions of nitrogen oxides (NOx), sulphur oxides (SOx), particulate matter (PM), and volatile organic compounds (VOC), were 49.4 %, 45 %, 4 %, and 1.6 %, respectively. Furthermore, the amounts of emission were compared when ships navigated at their average service speed, 12, 10, and 8 knots in the RSZ, respectively. At 12 knots, the reduction in emissions was more than that of the ships navigating at their average service speed by 39 % in NOx, 40 % in VOC, 42 % in PM, and 38 % in Sox. At 10 knots, the emission reductions were 52 %, 54 %, 56 %, and 50 % in NOx, VOC, PM, and Sox, respectively. At 8 knots, the emission reductions were 62 %, 64 %, 67 %, and 59 % in NOx, VOC, PM, and Sox, respectively. As a result, the emissions were ef ectively reduced when there was a reduction in the ship's speed. Therefore, it is necessary to consider limiting the speed of ships entering and leaving the port to decrease the total quantity of emissions.

Influence of Climate Factors and PM10 on Rotaviral Infection: A Seasonal Variation Study (Rotavirus 감염의 연도별 유행시기의 변동양상 및 기후요소와 PM10과의 관계)

  • Im, Hae-Ra;Jeon, In-Sang;Tchah, Hann;Im, Jeong-Soo;Ryoo, Eell;Sun, Yong-Han;Cho, Kang-Ho;Im, Ho-Joon;Lee, Gwang-Hoon;Lee, Hak-Soo;Kang, Yune-Jeung;Noh, Yi-Gn
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.2
    • /
    • pp.120-128
    • /
    • 2003
  • Purpose: Recently, while the authors were experiencing that the epidemic period of rotaviral infection happened more in the early spring, we tried to find out how the outbreaks of rotaviral infection are changing in detail depending on the weather condition since it has something to do with the climate factors and PM10. Methods: Fourteen hundreds seventy nine patients who were proved to be positive to rotavirus were chosen among children less than 5 years old from January 1995 to June 2003. Among various climate factors, monthly average temperature, humidity, rainfall and PM10 were selected. Results: Rotaviral infection was most active in 2002 as 309 (20.9%) patients. It has been the spring that is the most active period of rotaviral infection since 2000. The temperature (RR=0.9423, CI=0.933424~0.951163), rainfall (RR=1.0024, CI=1.001523~1.003228) and PM10 (RR=1.0123, CI=1.009385~1.015248) were significantly associated with the monthly distribution of rotaviral infection. Conclusion: Through this study we determined that the epidemic period of rotaviral infection is changed to spring, which is different from the usual seasonal periods such as late fall or winter as reported in previous articles. As increased PM10 which could give serious influence to the human body, and changing pattern of climate factors such as monthly average temperature and rainfall have something to do with the rotaviral infection, we suppose that further study concerning this result is required in the aspects of epidemiology, biology and atmospheric science.

  • PDF

Composition comparison of PM10 and PM2.5 fine particulate matter for Asian dust and haze events of 2010-2011 at Gosan site in Jeju Island (황사와 연무 시 PM10 및 PM2.5 미세먼지 조성 비교: 2010-2011년 고산지역 측정)

  • Kim, Ki-Ju;Lee, Seung-Hoon;Hyeon, Dong-Rim;Ko, Hee-Jung;Kim, Won-Hyung;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • The $PM_{10}$ and $PM_{2.5}$ samples were collected at Gosan Site of Jeju Island, and analyzed, in order to investigate the size distribution and pollution characteristics of their components. $NH{_4}{^+}$, nss-$SO{_4}^{2-}$, $K^+$, and $CH_3COO^-$ were mostly existed in fine particles. Meanwhile, $NO{_3}{^-}$ was distributed in both fine and coarse particles, and $Na^+$, $Cl^-$, $Mg^{2+}$, nss-$Ca^{2+}$ were rich in coarse particle mode. The concentrations of nss-$Ca^{2+}$ and $NO{_3}{^-}$ were increased 36.7 and 3.2 times in coarse particles, and 15.0 and 3.1 times in fine particles during the Asian Dust periods. Especially, the concentrations of crustal elemental species such as Al, Fe, Ca, K, Mg, Ti, Mn, Sr, Ba were highly increased for those periods. In the haze events, the concentrations of secondary air pollutants were increased 1.3~2.6 and 1.5~4.2 times in coarse and fine particles, respectively. Moreover, the remarkable increase of $NO{_3}{^-}$ concentration was also observed in fine particle mode. The factor analysis showed that the composition of coarse particles was influenced mainly by marine sources, followed by soil and anthropogenic sources. On the other hand, the fine particles were influenced by anthropogenic sources, followed by marine and soil sources.

Detection of Pathogenic Viruses in the Atmosphere during Asian Dust Events in Incheon City (인천지역에서 황사 기간 동안 대기 중의 바이러스 검출에 관한 연구)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Sun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.279-285
    • /
    • 2005
  • Background : Ambient particles during Asian dust events are usually less than $10{\mu}m$ in size, and known to be associated with the adverse effects on the general population. There is little evidence linking Asian dust to adverse effects on the airways. In 2002, the authors found that particulate matter during Asian dust events had an effect on the symptoms and pulmonary function of patients with bronchial asthma. An aggravating factor might be that of a viral infection, but this remains unclear. Conversely, it has been speculated that African dust may carry the virus responsible for foot and mouth disease. Asian dust events are also likely to be responsible for transporting viruses, some of which are pathogenic, and common in many environments. Therefore, in this study, air samples were screened for the presence of viruses. Methods : Air samples were collected 20 times each during Asian dust events and under non-dust conditions, for at least 6 hours per sample, using a high volume air sampler (Sibata Model HV500F), with an airflow rate of 500L/min, between April and August 2003, and between April and August 2004. The samples were then screened for the presence of targeted viruses (Influenza A, B, Hog cholera virus, and Aphthovirus) using a polymerase chain reaction method. Results : One Asian dust event occurred between April and August 2003, and 3 between April and August 2004, with a 24 hour average PM10 level of $148.0{\mu}g/m^3$. The 24 hour average PM10 level was $57{\mu}g/m^3$. There was a significant difference in the PM10 concentration between dusty and clear days. No viruses (Influenza virus, Aphthovirus, and Hog cholera virus) were identified in the air samples obtained during the dusty days. Conclusions : Although no virus was detected in this study, further studies will be needed to identify suspected viruses carried during Asian dust events, employing more appropriate virus detection conditions.

Seasonal Dust Concentration and Characteristics of Windowless Broiler Building (무창 육계사의 계절별 먼지 농도와 특성 연구)

  • Choi H. C.;Yeon G. Y.;Song J. I.;Kang H. S.;Kwon D. J.;Yoo Y. H.;Barroga A. J.;Yang C. B.;Chun S. S.;Kim Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.197-206
    • /
    • 2005
  • This study was carried out to investigate the concentration and characteristics of dust originating from windowless broiler building in each season. 12.0m width and 46m tenth with side wall height of 3.0m was investigated and capacity was 12,800 birds at a stock density of 23.2 birds per square meter. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10{\mu}m(PM10),\;2.5{\mu}m (PM2.5),\;and\;1{\mu}m(PM1)$ were measured at 30-minute intervals. On the basis of broiler age, the average dust concentration in summer in TSP as follows: 1,229 904.5 558.8 and $1,053{\mu}g/m^3$ on the broilers' first to fourth week of age, respectively. But during winter, the average dust concentration showed an increasing pattern, as follows: 465.4, 1,401, 4,497, 5,097 and $6,873{\mu}g/m^3$ on the broilers' first to fifth week of age, respectively. The maximum dust concentration of $11,132{\mu}g/m^3$ was observed on the fifth week. On a daily basis, the maximum dust concentration during summer was detected in early morning, and the minimum in the afternoon. The aerial dust particle size of $0.05\~0.35{\mu}m$ was the highest in number. But on volume basis, particle size of 16~99 un had the largest percentage in the broiler house. Crude protein of the dust $(42.8\~65.2\%)$, on dry matter basis, was higher than that $(20.5\~24.5\%)$ fed to the broilers. Heavy metal concentration of the dust also had high levels compared with that of the feed.

  • PDF

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(I) - Effect zone of environmental pneumoconiosis and fugitive dust - (대구 안심연료단지 환경오염물질 노출 평가(I) - 환경성 진폐증 및 비산먼지 영향권역 -)

  • Jung, Jong-Hyeon;Oh, In-Bo;Phee, Young-Gyu;Nam, Mi-Ran;Hwang, Mi-Kyoung;Bang, Jin-Hee;Jeon, Soo-Bin;Lee, Sang-sup;Yu, Seung-do;KimS, Byung-Seok;Yoo, Seok-Ju;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.366-379
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter(PM) pollution and its effect on health of residents living near Ansim Briquette Fuel Complex in Daegu metropolitan region. Methods: The California Puff(CALPUFF) dispersion model, version 5.8, which can estimate the dispersion direction and range of airborn $PM_{10}$ was used to determine the possible areas affected by $PM_{10}$ pollutants emitted from Ansim briquette fuel complex. The CALPUFF modeling with 200 m grid-cell resolution was performed based on $PM_{10}$ emissions estimated from the amount of coal consumption in the fuel complex for four months in 2012. The Weather Research and Forecasting(WRF) fields were processed using CALMET to produce CALPUFF-ready meteorological inputs. Also, the distance from Ansim Briquette Fuel Complex to the residence of each environmental pneumoconiosis patient was analyzed. In addition, the affecting region of the pollutants emitted from briquette factories in Ansim Briquette Fuel Complex was determined. Results: CALPUFF modeling results showed that the highest concentrations of $PM_{10}$ were found near around the fuel complex. The modeled $PM_{10}$ distributions were characterized by significant decreases in concentration with distance from the complex. Seasonally, the highest concentration of $45{\mu}g/m^3$ was calculated in October which was mostly due to the distinct variation of amount of emission. Additional modeling with the maximum $PM_{10}$ emission of about 88 tons per year in 1986 showed that the highest concentration in October was nearly increased by 8 times than the concentration modeled with emission of 2010. As a result of medical examination and interviews for the residents in Ansim Briquette Fuel Complex and its surroundings, 8 environmental pneumoconiosis patients were found. These patients do not have occupational exposure and history. These patients have lived 0.3~1.1 km area in Ansim Briquette Fuel Complex and its surroundings. Conclusions: Airborne particles emitted from Ansim Briquette Fuel Complex can contribute to significant increase in $PM_{10}$ concentration in residential areas near around the complex. Especially, the residents near fuel complex may exposed to the pollutants emitted from the factories in Ansim Briquette Fuel Complex.

A Study on Particulate Matter Forecasting Improvement by using Asian Dust Emissions in East Asia (황사배출량을 적용한 동아시아 미세먼지 예보 개선 연구)

  • Choi, Daeryun;Yun, Huiyoung;Chang, Limseok;Lee, Jaebum;Lee, Younghee;Myoung, Jisu;Kim, Taehee;Koo, Younseo
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.531-546
    • /
    • 2018
  • Air quality forecasting system with Asian dust emissions was developed in East Asia, and $PM_{10}$ forecasting performance of chemical transport model with Asian dust emissions was validated and evaluated. The chemical transport model (CTM) with Asian dust emission was found to supplement $PM_{10}$ concentrations that had been under-estimated in China regions and improved statistics for performance of CTM, although the model were overestimated during some periods in China. In Korea, the prediction model adequately simulated inflow of Asian dust events on February 22~24 and March 16~17, but the model is found to be overestimated during no Asian dust event periods on April. However, the model supplemented $PM_{10}$ concentrations, which was underestimated in most regions in Korea and the statistics for performance of the models were improved. The $PM_{10}$ forecasting performance of air quality forecasting model with Asian dust emissions tends to improve POD (Probability of Detection) compared to basic model without Asian dust emissions, but A (Accuracy) has shown similar or decreased, and FAR (False Alarms) have increased during 2017.Therefore, the developed air quality forecasting model with Asian dust emission was not proposed as a representative $PM_{10}$ forecast model in South Korea.

Reaction Characteristics of Oxidation Catalysts for HCCI Engine (HCCI 엔진용 산화촉매의 반응특성)

  • Park, Sung-Yong;Kim, Hwa-Nam;Choi, Byung-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.165-171
    • /
    • 2010
  • The Homogeneous Charge Compression Ignition (HCCI) engine concept allows for both NOx and particulate matter to be reduced simultaneously, and it is a promising way to meet the next environmental challenges. Unfortunately, HCCI combustion often increases CO and HC emissions. The development of oxidation catalyst (OC) requires high conversion efficiency for CO and HC at low temperature. Conventional oxidation catalyst technologies may not be able to convert these emissions because of the saturation of active catalytic sites. The OC used in this study was 600 cpsi cordierite. Three kinds of OC with different amounts of Pt and Pd were used. The influence of the space velocity (SV), $H_2O$ and $O_2$ concentration was also studied. All types of OCs were found to have over 90% CO conversion efficiencies at $170^{\circ}C$. When in the presence of water vapor, CO conversion was increased, but $C_3H_8$ conversion was decreased. The performance of the OC was not influenced by initial the HC concentration. The 2Pt/Pd catalyst was better in terms of thermal aging than the Pt-only catalyst. The $LOT_{50}$ of both fresh and aged OC was increased with increasing SV and with the presence of $H_2O$.

Assessment of Conscious Coginition Degree and Survey on the Indoor Air Quality at a public School in Seoul (서울시 일부 학교의 실내 공기질 조사 및 인식도 평가)

  • Sohn, Jong-Ryeul;Byeon, Sang-Hoon;Kim, Young-Whan;Kim, Jong-Hyeok;Cho, Yun-Su;Lee, Jae-Young;Park, Youn-Ju
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.100-109
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and schools has been concern of people, scientists and related the public. And so in Seoul has recognized the healthy effect related to IAQ in schools. Therefore, the objective of this study reported in this article were to measure and compare the perception of IAQ of selected air pollutants at three different schools in Seoul. We performed a questionnaire survey of 400 students about their awareness for the importance of IAQ in our school. And we measured the IAQ of 3 schools considering as site region, construction year and studying level. The indoor air pollutants and parameters such as temperature, relative humidity, respirable particulate matter(PM10), formaldehyde(HCHO), total bacteria counts(TBC), carbon dioxide(CO$_2$), and noise were monitored in indoors. In results, all most response of occupant has recognized the awareness of IAQ at schools. The PMIO, TBC and Noise level of all schools were higher than the standard of the public 150 ${mu}$g/m$^3$ and 500CFU/m$^3$, the level formaldehyde(HCHO) was below 0.1 ppm of the healthy guideline of Korea And the concentration of CO$_2$ were investigated below 1,000 ppm of the standard implying ventilation in 2 schools except for 1 school(c school). Finally, the control of most important pollutants of IAQ in school were PM10, TBC and Noise. Therefore, it can be concluded that the indoor air quality of selected 3 schools studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems in schools, and all member relating school need to be effort to reduce the exposure of sources to undesirable indoor pollutants such as Particlate and Noise.

Spatial-temporal Assessment and Mapping of the Air Quality and Noise Pollution in a Sub-area Local Environment inside the Center of a Latin American Megacity: Universidad Nacional de Colombia - Bogotá Campus

  • Fredy Alejandro, Guevara Luna;Marco Andres, Guevara Luna;Nestor Yezid, Rojas Roa
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.232-243
    • /
    • 2018
  • The construction, development and maintenance of an economically, environmentally and socially sustainable campus involves the integration of measuring tools and technical information that invites and encourages the community to know the actual state to generate positive actions for reducing the negative impacts over the local environment. At the Universidad Nacional de Colombia - Campus $Bogot{\acute{a}}$, a public area with daily traffic of more than 25000 people, the Environmental Management Bureau has committed with the monitoring of the noise pollution and air quality, as support to the campaigns aiming to reduce the pollutant emissions associated to the student's activities and campus operation. The target of this study is based in the implementation of mobile air quality and sonometry monitoring equipment, the mapping of the actual air quality and noise pollution inside the university campus as a novel methodology for a sub-area inside a megacity. This results and mapping are proposed as planning tool for the institution administrative sections. A mobile Kunak$^{(R)}$ Air & OPC air monitoring station with the capability to measure particulate matter $PM_{10}$, $PM_{2.5}$, Ozone ($O_3$), Sulfur Oxide ($SO_2$), Carbon Monoxide (CO) and Nitrogen Oxide ($NO_2$) as well as Temperature, Relative Humidity and Latitude and Longitude coordinates for the data georeferenciation; and a sonometer Cirrus$^{(R)}$ 162B Class 2 were used to perform the measurements. The measurements took place in conditions of academic activity and without it, with the aim of identify the impacts generated by the campus operation. Using the free code geographical information software QGIS$^{(R)}$ 2.18, the maps of each variable measured were developed, and the impacts generated by the operation of the campus were identified qualitative and quantitively. For the measured variables, an increase of around 21% for the $L_{Aeq}$ noise level and around 80% to 90% for air pollution were detected during the operation period.