• Title/Summary/Keyword: PLT

Search Result 232, Processing Time 0.027 seconds

Effect of the Hydrogen Annealing on the Pb(Zr0.52Ti0.48)O3 Film using (Pb0.72La0.28)Ti0.94O3 Buffers ((Pb0.72La0.28)Ti0.94O3 Buffer를 사용한 Pb(Zr0.52Ti0.48)O3 박막의 수소 후열처리 효과)

  • Lee, Eun-Sun;Li, Dong-Hua;Chung, Hyun-Woo;Lim, Sung-Hoon;Lee, Sang-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.4
    • /
    • pp.327-329
    • /
    • 2005
  • Pb(Zr/sub 0.52/Ti/sub 0.48/)O₃(PZT) thin films were deposited by using a pulsed laser deposition method on a Pt/Ti/SiO₂/Si substrate with (Pb/sub 0.72/La/sub 0.28/)Ti/sub 0.93/O₃ (PLT) buffer and on a Pt/Ti/SiO₂/Si substrate without buffer. These films were annealed in H₂-contained ambient for 30 minutes at the substrate temperature of 400。C to evaluate the forming gas annealing effects. The comparative studies on the ferroelectric properties of these two films were carried out, which are shown that ferroelectric properties, such as remanent polarization didn't change in the case of PLT buffered PZT film while remanent polarization value of PZT film degraded from 20.8 C/㎠ to 7.3 C/㎠. The leakage current became higher in both cases, but that of the more-oriented PZT film had the moderate value of the 10/sup -6/ order of A/㎠. This is mainly because the hydrogen atoms which make the degradation of PZT films cannot infiltrate into the more -oriented PZT film as well as the less-oriented PZT film.

Is Early Detection of Colon Cancer Possible with Red Blood Cell Distribution Width?

  • Ay, Serden;Eryilmaz, Mehmet Ali;Aksoy, Nergis;Okus, Ahmet;Unlu, Yasar;Sevinc, Baris
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.753-756
    • /
    • 2015
  • Background: Red cell distribution width (RDW) is one of the standard parameters with blood cell counts. Much previous research has indicated that it increases in cases of systemic inflammation or cardiametabolic incident. However, information on the relation of RDW with solid tumors causing systemic inflammation is limited. In the present research, we examined the relation of RDW with malignant and benign lesions of the colon. Materials and Methods: 115 patients with colon polyps (group 1), and 30 with colon cancer (group 2) who were diagnosed histopathologically in our clinic between January 2010-January 2013 were scanned retrospectively. Patients with anemia, hematologic diseases and active inflammation were excluded. RDW, mean corpuscular volume (MCV), hemoglobin (Hgb) and platelet (Plt) measurements were recorded and their relations with the malignant and benign lesions of the colon were examined. Results: Both groups were similar in age and gender distribution. RDW values of patients with colon cancer were significantly higher than the patients with colon polyp (p=0,01). No significant differences were detected between the two groups in terms of MCV and Plt values (p>0,05). Conclusions: RDW can be used as an early warning biomarker for solid colon tumors. Further prospective research is required on the relations of cheap and easily measured RDW parameters with colon malignancies.

The Hematologic Study as risk factors on premature examination of stroke (PES) (중풍위험인자로서의 혈액학적 소견 연구 - 중풍조기검진 326명에 대한 분석 -)

  • Han, Deok-hee;Seol, In-chan;Kim, Yoon-sik
    • Journal of Haehwa Medicine
    • /
    • v.13 no.2
    • /
    • pp.221-229
    • /
    • 2004
  • 1.Purpose Stroke is the most frequent cause of mortality and morbidity rate in Korea with ischemic heart disease and cancer. Recent recurrence rate of stroke is high, but little attention had been given to the features of its' cause. The purpose of this studies is to examine the hematologic states in Korean normal adults through premature-examination of stroke(PES). 2.Method The study group consisted of 326 cases that they had no significant results by CT through premature examination of stroke(PES) in Cheonan oriental hospital of Daejeon university. We tested RBC, hemoglobin, hematocrit, WBC, PT, PTT, PLT, total protein, albumin, total bilirubin, direct bilirubin, GOT, GPT, $\gamma$-GTP, total cholesterol, triglyceride, HDL-C, glucose, BUN, creatinine, Na, K and evaluated by cross sectional study. 3.Result In the PES, there were many patients with low RBC(11%), shorten PT(26.7%), delayed PTT(19.3%), high TP, GPT, ${\gamma}$ -GTP(respective1y 16.9%, 14.4%, 13.5%), high cholesterol level and triglyceride level(respectively 18.7%, 28.2%). We didn't found significant cases in hemoglobin, hematocrit, WBC, PLT, albumin, total bilirubin, direct bilirubin, GOT, HDL-C, glucose, BUN, creatinine, Na, K. 4.Conclusion In this study, we demonstrated that short PT, high triglyceride level are special views in PES. Also prospective studies are needed continuously to search the preventing methods of the CVA.

  • PDF

Electrical and Retention Properties of MFSFET Device (MFSFET 소자의 전기적 및 리텐션 특성)

  • Chung, Yeun-Gun;Kang, Seong-Jun;Joung, Yang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.570-576
    • /
    • 2007
  • In this study, the characteristics of metal-ferroelectric-semiconductor FET (MFSFET) device is investigated using field-dependent polarization and square-law FET models. From drain current with the gate voltage variation, when coercive voltages of ferroelectric thin film are 0.5 and 1V, the memory windows are 1 and 2V, respectively. When the gate voltages are 0, 0.1, 0.2 and 0.3V, the difference of saturation drain currents of the MFSFET device at two threshold voltages in ID-VD curve are 1.5, 2.7, 4.0, and 5.7mA, respectively. As a result of the analysis for drain currents after tine lapse, which is based on the simulation for hysteresis loop and the fitting of retention properties of ferroelectric thin films such as PLZT(10/30/70), PLT(10) and PZT(30/70) thin film shows excellent reliability that the decrease of saturation current is about 18% after 10 years.

Characteristics of Quasi-MFISFET Device Considering Leakage Current (누설전류를 고려한 Quasi-MFISFET 소자의 특성)

  • Chung, Yeun-Gun;Joung, Yang-Hee;Kang, Seong-Jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.9
    • /
    • pp.1717-1723
    • /
    • 2007
  • In this study , quasi-MFISFET (Metal-Ferroelectric-Insulator-Semiconductor FET) devices are fabricated using PLZT(10/30/70), PLT(10), PZT(30/70) thin film and their drain current properties are investigated. It is found that the drain current of quasi-MFISFET is directly influenced by the polarization strength of ferroelectric thin fan. Also, when the gate voltages are ${\pm}5\;and\;{\pm}10V$, the memory windows are 0.5 and 1.3V, respectively. It means that the memory window is changed with the variation of coercive voltage generated by the voltage applied on ferroelectric thin film. The electric field and the leakage current with time delay of PLZT(10/30/70) thin lam are measured to investigate the retention property of MFISFET device. Some material parameters such as current density constant, $J_{ETO}$, electric field dependent factor K and time dependent factor m are obtained. The variation of charge density with time is quantitatively analyzed by using the material parameters.

Effect of Bisphenol A Administration on Reproductive Characteristic and Blood Metabolite in Mice (BPA의 투여가 생쥐의 번식특성과 혈액성분에 미치는 영향)

  • Park, D.H.;Jang, H.Y.;Park, C.K.;Cheong, H.T.;Kim, C.1.;Yang, B.K.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.957-966
    • /
    • 2004
  • The objective of this study was to investigate the effects of BPA on reproductive characteristic and blood hematological and chemical values in mice. The male mice were intraperitoneally injected BPA in native control(no treatment), positive control(corn oil, 3$m\ell$/kg B.W), 0.05, 0.5 and 5.0mg BPA/kg B.W and female mice were injected BPA in control(corn oil, 3$m\ell$/kg B.W), 0.05, 0.5 and 5.0mg BPA/kg B.W with 5 times at 3 days interval for 14 days. The administration of BPA in male mice didn't affect the body and reproductive organ weight such as testis, epididymis, vesicular gland and coagulating gland. We found that the 5.0mg BPA group was significantly reduced the sperm concentration and increased the sperm abnormality compared to native, positive control and 0.05mg BPA groups(P<0.05), but any other effects were not found in sperm viability and motility in BPA treatment groups. The RBC, HB, HT, MCV, MCH, MCHC, albumin, BUN and total protein of blood hematological and chemical values in male were not different in all experimental groups(P>0.05). However, the value of WBC was slightly lower in BPA treatment groups than that of control groups and PLT was slightly higher in BPA groups than that of control groups, but not significantly defference among the experimental groups(P>0.05). In female mice, the effects of BPA on body weight didn’t affect in all experimental groups, but ovary weights in 0.5 and 5.0mg BPA groups were significantly increased compared to those in control and 0.05mg BPA group(P<0.05). The uterine weight in BPA groups was slightly higher than that of control group, but not significantly different in all experimental groups(P>0.05). The RBC, Hb, HT, MCV, MCH, MCHC, albumin and total protein of blood hematological and chemical values in female were not different in all experimental groups(P>0.05). The values of WBC and PLT in BPA groups were slightly higher than that of control, but not significantly different among the experimental groups. The concentration of BUN was the higher in BPA groups than that of control group. The histological evaluation of testis, ovary and uterus were not different in all experimental groups.

Effect of DEHP Administration on Reproductive Characteristic and Blood Metabolite in Mice (DEHP의 투여가 생쥐의 번식특성과 혈액 성분에 미치는 영향)

  • Park, Dong-Heon;Jang, Hyun-Yong;Park, Choon-Keun;Cheong, Hee-Tae;Kim, Choung-Ik;Yang, Boo-Keun
    • Development and Reproduction
    • /
    • v.8 no.2
    • /
    • pp.77-84
    • /
    • 2004
  • The purpose of this experiment was to determine the effects of di(2-ethylhexyl) phthalate(DEHP) on reproductive characteristic, blood hematological and chemical values in mice. The male mice were intraperitoneally injected DEHP in negative control(no treatment), positive control(corn oil, 3ml/kg B.W), 0.5, 1.0 and 10.0mg DEHP/kg B.W and the female mice were injected DEHP in control(corn oil, 3ml/kg B.W), 0.5, 1.0 and 10.0mg DEHP/kg B.W with 5 times for 15 days on 3 days interval. The administration of DEHP in male mice were not affect on body weight, epididymis, vesicular gland and coagulating gland weight. The testis weight were slightly higher in DEHP treatment groups than in control. The semen characteristics(sperm concentration, viability, motility and abnormality) of male mice were not difference in all experimental groups. The RBC, Hb, HT, MCV, MCH, MCHC< PLT, albumin, BUN and total protein of blood hematological and chemical values were not affect the administration of DEHP in mice. The WBC values in 10.0mg DEHP group was slightly difference in all experimental group(P>0.05). The histological evaluation of testis, ovary and affevt the reproductive characteristic, blood hematological and chemical values.

  • PDF

A Study on the Analysis of Galloping for Power transmission line (송전선의 전선도약 해석에 관한 연구)

  • 김환성;변기식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1051-1057
    • /
    • 2001
  • In this paper, we deal with three types of modelling method for the analysis of galloping in power transmission line (PTL). The single mass model is obtained under linearization method and it is applied into f-order model. On these models, the nature frequencies of PTL are obtained and it makes an effects on the galloping directly. In simulation, we verify that the maximum magnitude of nature frequency depends on the galloping distance of PTL. Also from the analysis of frequency response, a few of reduction method for galloping are introduced which is effected by distance of PTL, wind velocity and icing types.

  • PDF

Realization of the IEC 61000-4-13 Flickermeter using PSCAD/EMTDC Module (PSCAD/EMTDC를 이용한 IEC 61000-4-15 플리커미터 Module 개발)

  • Jang, Young-Soo;Cho, Soo-Hwan;Jang, Gil-Soo;Kwon, Sae-Hyuk;Jeon, Young-Soo;Kwak, No-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.117-119
    • /
    • 2005
  • Voltage Flicker는 다른 전력품질 요소들과는 달리, 전압의 흔들림이 사람의 눈과 뇌에 미치는 영향을 고려한 지수이다. IEC 61000-4-15에서는 이러한 플리커의 평가 알고리즘을 제시하고 있으며, 제한치를 $Pst{\leq}1$, $Plt{\leq}0.65$로 정의하고 있다. 이 제한치는 다양한 비선형 부하들의 경우에도 만족시켜야 하며, 계통의 설계 시 미리 고려를 할 필요성이 있다. 본 논문에서는 Fortran을 이용하여 IEC61000-4-15의 플리커미터 알고리즘을 구현하고 이를 PSCAD/EMTDC의 Module로 적용시켜, 시험 계통이 플리커 제한치를 만족시키는가에 대한 테스트가 가능하도록 하였다.

  • PDF

Application of in-situ testing Methods for Bearing Capacity Estimation of Railroad Roadbed (철도 노반의 지지력 평가를 위한 현장 시험법 적용성 연구)

  • Park, Chang-Woo;Choi, Chan-Yong;Lee, Il-Wha;Kim, Dae-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.866-875
    • /
    • 2006
  • The field plate load test a good potential for determining modulus since it measures both plate pressure and settlement. However, because The field plate load test is expensive and takes plenty of time for operation, it is very difficult to figure out the test characteristics of railroad roadbed in detail. For faster and economical operation, the Dynamic Cone Penetrometer(DCP) and the Light Falling Weight Deflectometer(LFWD) have been utilized for estimating the bearing capacity of railroad roadbed. The objective of this study is to determine the relationship between the test(PLT, DCP, LFWD) of the railroad roadbed in Korea. The DCP test and LFWD test for evauluating the strength of railroad roadbed materials produced in Korea are presented in this paper.

  • PDF