• Title/Summary/Keyword: PLS-II

Search Result 65, Processing Time 0.028 seconds

Welding Deformation of The PLS Storage Ring Chamber (포항가속기 저장링 Chamber의 용접변형)

  • 최만호;김효윤;한영진;최우천
    • Journal of Welding and Joining
    • /
    • v.11 no.4
    • /
    • pp.36-43
    • /
    • 1993
  • 1)sector chamber II에서 가장 우려되었던 J5, J8의 변형량이 $28\mu\textrm{m}$,$36\mu\textrm{m}$ 이었으므로 목표 값 $50\mu\textrm{m}$을 충분히 보증할 수 있다. 2) Helicoflex gasket type으로 제작된 초도품 챔버에서는 140.deg.C bake-out후 이온 펌프만 으로 20시간 진공배기한 후의 진공도는 2*$10^{-9}$ Torr에 도달하였으며, 용접 type으로 제 작된 챔버에서는 2*$10^{-10}$ Torr에 도달하여서 진공도도 우수하였다. 3)표면조도에 민감한 Helicoflex gasket를 사용하지 않고 알루미늄 플랜지를 용접하여 AI gasketc 를 이용할 수 있기 때문에 초도품챔버에서와 같이 알루미늄 챔버와 스텐레스 스틸 부품을 연결하 는 stainless spool piece가 필요하지 않게 된다. 4)고가의 helicoflex gasket을 쓰지 않으므로 가격절감을 할 수 있다.

  • PDF

Fabrication and Installation of the MPK-EPU Vacuum System

  • Hong, Man-Su;Gwon, Hyeok-Chae;Han, Hong-Sik;Kim, Chang-Gyun;Ha, Tae-Gyun;Kim, Jae-Yeong;Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.148.1-148.1
    • /
    • 2014
  • 포항가속기연구소는 Dipole Magnet, Wiggler, Undulator 등 다양한 광원에서 발생되는 강한 방사광을 여러 연구에 이용하고 있다. Max-Planck POSTECH 분원용 타원편광 Undulator (이하, MPK-EPU)는 carbon의 흡수선을 포함하는 250 eV에서 시작하여, 1,500 eV~3,000 eV 에너지 영역의 방사광을 발생시켜 자성물질을 비롯한 다양한 이방성 물질의 연구를 수행하는데 활용할 예정이다. 현재, MPK-EPU용 진공용기의 기계가공, 화학세척, 용접 및 최종 초고진공 진공 달성을 위한 탈기체처리, NEG 활성화 작업등을 마무리하고 PLS-II 저장링 6A 구간에 설치 완료하였다. 이 논문에서는 MPK-EPU용 진공시스템의 제작 및 설치작업에 대한 전반적인 사항과 진공작업 및 그 결과를 발표하고자 한다.

  • PDF

방사광 이용 표면분석 총론

  • Hwang, Chan-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.79-79
    • /
    • 2012
  • 방사광이 고체물리의 연구에 이용되기 시작한 60년대 말 이후부터 지난 반세기동안 방사광시설과 이를 이용한 분석 장치들은 큰 발전이 거듭되어 왔다. 90년대에는 포항가속기 연구소에서 방사광을 이용한 실험 시설이 완공되어 지난 20 여년간 이용되어 왔고 현재는 이시설이 업그레이드(PLS II) 되어 조만간 다시 이용자에게 공개될 예정이다. 연 x-선의 경우 광전자를 분석하게 되면 시료의 표면으로부터 1 nm - 수십 nm 두께의 현상에 대한 분석이 가능하다. 경 x-선(수 keV 이상의 에너지를 갖는)의 경우는 비교적 큰 penetration depth를 갖지만 grazing incidence를 이용하게 되면 수 나노 이하의 두께에서 일어나는 현상에 대한 연구가 가능하다. 본 tutorial에서는 전자의 에너지 영역인 VUV영역에서 가능한 방사광을 이용한 여러 가지 표면분석법(XPS, MCD, XAS, ARPES, SPEM, PEEM등)에 대한 세부강의를 제공하고자 한다. 총론에서는 경 x-선을 포함하는 방사광을 이용한 표면분석기술이 어디까지 발전되어 왔고 어느 수준까지 분석이 가능한지에 대한 전체적인 view를 제공하고자 한다. 본 tutorial은 이제 막 방사광을 이용한 연구를 수행하려는 연구자들, 지금까지 특정 분석기술을 사용한바 있는 연구자들, 그리고 여러 가지 방사광이용 표면분석방법에 대한 이해가 필요한 소재 혹은 소자의 개발자들에 좋은 배움의 기회가 될 것입니다.

  • PDF

Design Efforts of PAL XFEL RF Components to Reduce RF Breakdown Due to Surface Electric Gradient in High Power Operation

  • Ju, Yeong-Do;Park, Yong-Jeong;Lee, Heung-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.239-239
    • /
    • 2013
  • The peak klystron power for the PAL (Pohang Accelerator Laboratory) XFEL (X-ray Free Electron Laser) is up to 80 MW which is higher than that of PLS-II LINAC. To prevent the RF breakdown such a high power operation, some of RF components need to be redesigned to reduce the surface electric field gradient to be less than the breakdown gradient at the vacuum-metal surface. For instances, the redesign of the Stanford Linear Accelerator Energy Doubler (SLED) system, the directional coupler and 3dB power splitter using the finite-difference time-domain (FDTD) simulation will be presented.

  • PDF

Compensation of Variation from Long-Term Spectral Measurement for Non-invasive Blood Glucose in Mouse by Near-Infrared Spectroscopy (근적외분광분석법을 이용한 생쥐꼬리에서의 비침습 혈당 정량시 장기간 측정에 따른 변이 요인의 보정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.48 no.3
    • /
    • pp.177-181
    • /
    • 2004
  • Non-invasive blood glucose measurement from mouse tail was performed by near-infrared (NIR) spectroscopy. Three groups; normal, type I diabetes (insulin dependent diabetes mellitus, IDDM), type II diabetes (non-insulin dependent diabetes mellitus, NIDDM) group, were studied over a 10 weeks period with the collection of near-infrared (NIR) spectra. Spectral variations from long-term measurement (10 weeks) from dramatic and nonlinear changes in the optical properties of the live tissue sample were compensated by chemometrics techniques such as principle component analysis (PCA) and partial least squares (PLS) regression. The effect from mouse body temperature changes on NIR spectral data was also considered. This study showed that the compensation of variations from long-term measurement and temperature changes improved calibration accuracy of non-invasive blood glucose measurement.

Design of a Multi-Band Low Noise Amplifier for 3GPP LTE Applications in 90nm CMOS (3GPP LTE를 위한 다중대역 90nm CMOS 저잡음 증폭기의 설계)

  • Lee, Seong-Ku;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.5
    • /
    • pp.100-105
    • /
    • 2010
  • A multi-band low noise amplifier (LNA) is designed in 90 nm RF CMOS process for 3GPP LTE (3rd Generation Partner Project Long Term Evolution) applications. The designed multi-band LNA covers the eight frequency bands between 1.85 and 2.8 GHz. A tunable input matching circuit is realized by adopting a switched capacitor array at the LNA input stage for providing optimum performances across the wide operating band. Current steering technique is adopted for the gain control in three steps. The performances of the LNA are verified through post-layout simulations (PLS). The LNA consumes 17 mA at 1.2 V supply voltage. It shows a power gain of 26 at the normal gain mode, and provides much lower gains of 0 and -6.7 in the bypass-I and -II modes, respectively. It achieves a noise figure of 1.78 dB and a IIP3 of -12.8 dBm over the entire band.

Nondestructive Determination of Sugar Contents in Shingo Pears with Different Temperature

  • Lee, Kang-J.;Choi, Kyu H.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1264-1264
    • /
    • 2001
  • The affect of surface temperatures of fruits on spectrum which measures actual sugar contents was observed. PLSR was applied to develop the sugar content evaluation system that was not affected by temperature. The reflected spectrum was used at the wavelengths of 654 and 1052nm with the separation distance of 2.5nm. To increase the conformance of a model using unknown samples, let the minimum value of PRESS be an optimum factor. 71 Shingo pears stored in a refrigerator were left in a room temperature for a while and these temperatures and reflected spectrums were measured. Reflected spectrums were measured at the wavelengths of 654 and 1052nm, 3 samples in one second. To measure these at different temperatures, the experiment was repeated hourly and four times. Starting temperatures of 2-3 were increased up to 17. The total number of measured spectrum was 284. To develop a sugar content evaluation system model using measured reflected spectrum, three groups of samples were considered. First group had 51 samples at 14 and second group had 141 samples with lower or higher temperatures than 14. Third group had 155 samples with well distributed temperatures. Other samples were used as validations to ensure the conformance. Measuring the sugar contents of samples with surface temperatures other than 14 were difficult with PLS model I, developed by using a sample temperature of 14. If the sugar contents were compensated using samples' temperatures, results of prediction would be close to the expected results and it would be one of the most important factors to develop this system. PLS models I and II could compensate the temperature but the precision would not come up to the standard. High precision was expected by using samples with wide ranges of temperatures and sugar contents. Both models showed the possibility of an improvement of a sugar content evaluation system disregarding the temperature. For practical use of a system, selecting samples should be done carefully to reduce the effect of the temperature.

  • PDF

Covariance patterns between ramus morphology and the rest of the face: A geometric morphometric study

  • Marietta Krusi;Demetrios J. Halazonetis;Theodore Eliades;Vasiliki Koretsi
    • The korean journal of orthodontics
    • /
    • v.53 no.3
    • /
    • pp.185-193
    • /
    • 2023
  • Objective: The growth and development of the mandible strongly depend on modeling changes occurring at its ramus. Here, we investigated covariance patterns between the morphology of the ramus and the rest of the face. Methods: Lateral cephalograms of 159 adults (55 males and 104 females) with no history of orthodontic treatment were collected. Geometric morphometrics with sliding semi-landmarks was used. The covariance between the ramus and face was investigated using a two-block partial least squares analysis (PLS). Sexual dimorphism and allometry were also assessed. Results: Differences in the divergence of the face and anteroposterior relationship of the jaws accounted for 24.1% and 21.6% of shape variation in the sample, respectively. Shape variation was greater in the sagittal plane for males than for females (30.7% vs. 17.4%), whereas variation in the vertical plane was similar for both sexes (23.7% for males and 25.4% for females). Size-related allometric differences between the sexes accounted for the shape variation to a maximum of 6% regarding the face. Regarding the covariation between the shapes of the ramus and the rest of the face, wider and shorter rami were associated with a decreased lower anterior facial height as well as a prognathic mandible and maxilla (PLS 1, 45.5% of the covariance). Additionally, a more posteriorly inclined ramus in the lower region was correlated with a Class II pattern and flat mandibular plane. Conclusions: The width, height, and inclination of the ramus were correlated with facial shape changes in the vertical and sagittal planes.

Discrimination of African Yams Containing High Functional Compounds Using FT-IR Fingerprinting Combined by Multivariate Analysis and Quantitative Prediction of Functional Compounds by PLS Regression Modeling (FT-IR 스펙트럼 데이터의 다변량 통계분석을 이용한 고기능성 아프리칸 얌 식별 및 기능성 성분 함량 예측 모델링)

  • Song, Seung Yeob;Jie, Eun Yee;Ahn, Myung Suk;Kim, Dong Jin;Kim, In Jung;Kim, Suk Weon
    • Horticultural Science & Technology
    • /
    • v.32 no.1
    • /
    • pp.105-114
    • /
    • 2014
  • We established a high throughput screening system of African yam tuber lines which contain high contents of total carotenoids, flavonoids, and phenolic compounds using ultraviolet-visible (UV-VIS) spectroscopy and Fourier transform infrared (FT-IR) spectroscopy in combination with multivariate analysis. The total carotenoids contents from 62 African yam tubers varied from 0.01 to $0.91{\mu}g{\cdot}g^{-1}$ dry weight (wt). The total flavonoids and phenolic compounds also varied from 12.9 to $229{\mu}g{\cdot}g^{-1}$ and from 0.29 to $5.2mg{\cdot}g^{-1}$dry wt. FT-IR spectra confirmed typical spectral differences between the frequency regions of 1,700-1,500, 1,500-1,300 and $1,100-950cm^{-1}$, respectively. These spectral regions were reflecting the quantitative and qualitative variations of amide I, II from amino acids and proteins ($1,700-1,500cm^{-1}$), phosphodiester groups from nucleic acid and phospholipid ($1,500-1,300cm^{-1}$) and carbohydrate compounds ($1,100-950cm^{-1}$). Principal component analysis (PCA) and subsequent partial least square-discriminant analysis (PLS-DA) were able to discriminate the 62 African yam tuber lines into three separate clusters corresponding to their taxonomic relationship. The quantitative prediction modeling of total carotenoids, flavonoids, and phenolic compounds from African yam tuber lines were established using partial least square regression algorithm from FT-IR spectra. The regression coefficients ($R^2$) between predicted values and estimated values of total carotenoids, flavonoids and phenolic compounds were 0.83, 0.86, and 0.72, respectively. These results showed that quantitative predictions of total carotenoids, flavonoids, and phenolic compounds were possible from FT-IR spectra of African yam tuber lines with higher accuracy. Therefore we suggested that quantitative prediction system established in this study could be applied as a rapid selection tool for high yielding African yam lines.

Variey Discrimination of Sorghum-Sudangrass Hybrids Seed Using near Infrared Spectroscopy (근적외선분광법을 이용한 수수×수단그라스 교잡종 종자의 품종 판별)

  • Lee, Ki-Won;Song, Yowook;Kim, Ji Hye;Rahman, Md Atikur;Oh, Mirae;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.40 no.4
    • /
    • pp.259-264
    • /
    • 2020
  • The aim of this study was to investigate the feasibility of discrimination 12 different cultivar of sorghum × sudangrass hybrid (Sorghum genus) seed through near infrared spectroscopy (NIRS). The amount of samples for develop to the best discriminant equation was 360. Whole samples were applied different three spectra range (visible, NIR and full range) within 680-2500 nm wavelength and the spectrastar 2500 Near near infrared was used to measure spectra. The calibration equation for discriminant analysis was developed partial least square (PLS) regression and discrimination equation (DE) analysis. The PLS discriminant analysis model for three spectra range developed with mathematic pretreatment 1,8,8,1 successfully discriminated 12 different sorghum genus. External validation indicated that all samples were discriminated correctly. The whole discriminant accuracy shown 82 ~ 100 % in NIR full range spectra. The results demonstrated the usefulness of NIRS combined with chemometrics as a rapid method for discrimination of sorghum × sudangrass hybrid cultivar through seed.