• Title/Summary/Keyword: PLC control

Search Result 569, Processing Time 0.027 seconds

Development of Reefer Container Real-time Management System (실시간 냉동컨테이너 관리 시스템 개발)

  • Choi, Sung-Pill;Jung, Jun-Woo;Moon, Young-Sik;Kim, Tae-Hoon;Lee, Byung-Ha;Kim, Jae-Joong;Choi, Hyung-Lim;Lee, Eun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2917-2923
    • /
    • 2015
  • In spite of a recent trend of container ships becoming larger in size, the current circumstance is that managing reefer containers marine transportation is being mostly dependent upon manpower. Particularly, in the case of bad weather or nighttime, reefer containers are not being monitored due to lack of safety device. For the purpose of reducing such risk, IMO is recommending a system using PLC but the system is not being used. In addition, they are still relying on manpower for control and reliability of freight in transit is decreasing due to lack of information during marine transportation for every subject related to freight as well as shipper. Accordingly, the purpose of this paper is to propose a real-time reefer container management system to effectively control all reefer containers widely being used across the world.

A Study on the Installation of SCR System for Generator Diesel Engine of Existing Ship (기존 선박의 디젤발전기용 SCR 시스템 설치에 관한 연구)

  • Ryu, Younghyun;Kim, Hongryeol;Cho, Gyubaek;Kim, Hongsuk;Nam, Jeonggil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.412-417
    • /
    • 2015
  • The IMO MEPC has been increasingly strengthening the emission standard for marine environment protection. In particular, nitrogen oxide (NOx) emissions of all ocean-going ships built from 2016 will be required to comply with the Tier-III regulation. In this study, a vanadia based SCR (Selective Catalytic Reduction) system developed for ship application was installed on a diesel engine for power generation of the training ship T/S SAENURI in Mokpo National Maritime University. For the present study, the exhaust pipeline of the generator diesel engine was modified to fit the urea SCR system. This study investigated the NOx reduction performance according to the two kind of injection method of urea solution (40%): Auto mode through the PLC (Programable Logic Control) and Manual mode. We were able to find the ammonia slip conditions when in manual mode method. So, the optimal urea injection quantity can be controlled at each engine load (25, 35, 50%) condition. It was achieved 80% reduction on nitrogen oxide. Furthermore, we found that the NOx reduction performance was better with the load up-down (while down to 25% from 50%) than the load down-up (while up to 50% from 25%) test.

Development of a Remote Dust Collector Bag Control System using Power Line Communication (전력선 통신을 이용한 원격 집진기 bag 제어 시스템 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.91-98
    • /
    • 2010
  • Advances in communications and control technology, the strengthening of the Internet, and the growing recognition of the urgency to reduce the risk and production cost are motivating the development of improvements in the traditional manufacturing industry. In this paper, we developed a remote dust collector bag control system which is a combination of advanced IT and traditional dust collector based on the event. At first, we made the A/D(Analog/Digital) converter using a micro processor because the differential pressure transmission, which is a sensor of the dust collector, produces analog volt data. A/D converter can provide RS-232 communication to connect with Power Line Communication(PLC) modem. And, n-bytes message format was defined for the efficient dust collector bag information transmission from a dust collector to a user. Also, we designed the data types to model the dust collector and the dust collector bag, and they were logically modeled using XML and object-oriented modeling method. In addition to that, we implemented the system for showing the dust collector bag exchange time exactly to users at real-time using various visual user interfaces.

System Development of a 100 kW Molten Carbonate Fuel Cell III (System Control and Operation Mode) (100 kW급 용융탄산염 연료전지 시스템 개발 III (시스템 제어 및 운전모드))

  • Lim, Hee-Chun;Ahn, Kyo-Sang;Seo, Hai-Kyung;Eom, Yeong-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1350-1352
    • /
    • 2003
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately two substacks with 90 cells are required to generate 100 kW at a current density of $125\;mA/cm^2$ with $6000\;cm^2$ of cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. To operate and evaluate the MCFC system, control and measurement system and operation mode are designed before 100 MCFC system construction. In system control schematics, OS, PLC and MMI were consisted and have roles for MCFC system control. For operation of 100 kW MCFC system, NS, PS PR mode were considerated step by step and simulated.

  • PDF

Electric Power Energy Saving and Efficient Measures in Buildings using the Smart-Meter (스마트미터를 활용한 건축물의 전력에너지 절감 및 효율화 방안)

  • Hwang, Hyun Bae;Jung, Byeong Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.365-372
    • /
    • 2014
  • In this paper, We implement a power-saving and efficient measures in buildings using the smart-meter. In order to save electric power energy, We propose an improved automatic power-factor controller(APFC) and demand control measures. This is achieved by controlling directly circuit breakers and the capacitor bank feeders in real time via a two-way smart-meter's ICT skills. Improved APFC is minimizing installation costs by series-parallel connecting heterologous capacitors to form a more diverse capacitor banking and controlling using the smart-meter. In order to suppress the demand power, We have designed a smart-meter with communication functions using Atmel's AVR465 and tested an operated lodging building for 24-hours. As a result, We made sure to always retained more than 95% power factor and did not occur over compensation.

Development of Intelligent Green Fountain Culture System for Healthy Emotional Self-Concept (건강한 정서 자아를 위한 지능형 녹색경관 제어시스템 개발)

  • Park, Seung-Min;Lee, Young-Hwan;Kim, Jun-Yeup;Ko, Kwang-Eun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.281-286
    • /
    • 2012
  • In the growing standard of people's lives, we want desire to create eco-friendly water space what is called the Green Technology that is in the limelight. These green space is introduced the cultural contents and we use the water, music, and nature as tool of emotional verbalism. Presently, when we want to make scenario, water landscape scenario is made by director. but these systems have some disadvantages as the cost and limitation of direction. There is a growing interest in the integrated control system based on PC and Internet. In this paper, it is about fountain control system. Previous research area was only one using programmable logic controller or industrial PC. we proposed the development of intelligent green fountain culture system for healthy emotional self-concept. And we made automatic weather sensing system that is designed by the intelligent green fountain culture system to estimate the time-variant system.

Application of the Laser Vision Sensor for Corrugated Type Workpiece

  • Lee, Ji-Hyoung;Kim, Jae-Gwon;Kim, Jeom-Gu;Park, In-Wan;Kim, Hyung-Shik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.499-503
    • /
    • 2004
  • This application-oriented paper describes an automated welding carriage system to weld a thin corrugated workpiece with welding seam tracking function. Hyundai Heavy Industries Corporation has developed an automatic welding carriage system, which utilizes pulsed plasma arc welding process for corrugated sheets. It can obtain high speed welding more than 2 times faster than traditional TIG based welding system. The aim of this development is to increase the productivity by using automatic plasma welding carriage systems, to track weld seam line using vision sensor automatically, and finally to provide a convenience to operator in order to carry out welding. In this paper a robust image processing and a distance based tracking algorithms are introduced for corrugated workpiece welding. The automatic welding carriage system is controlled by the programmable logic controller(PLC), and the automatic welding seam tracking system is controlled by the industrial personal computer(IPC) equipped with embedded OS. The system was tested at actual workpiece to show the feasibility and performance of proposed algorithm and to confirm the reliability of developed controller.

  • PDF

A Study on the Implemention of a Mini-MAP Network Interface Module for CIM (CIM을 위한 Mini-MAP 네트워크 접속장치의 구현에 관한 연구)

  • 김현기;이전우;하정현;정하재;채영도
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.10
    • /
    • pp.59-68
    • /
    • 1993
  • This paper describes implemation of 'General-purpose ETRI MAP interface module' (GEM) for Mini-MAP network. GEM operates as a Mini-MAP node in our FA system. To communicate between GEM and programmable devices(PD) such as PLC and CNC, serial communication is used. Application programs of a MiNi-MAP host system control and monitor programmable devices via GEM. GEM is implemented and tested on the basis of the MAP 3.0. TBC in the Nini-MAP board performs the function of the MAC sublayer. The LLC sublayer is implemented according to the specification of Class 3 that includes Type 1 and 3. And the MMS services are designed within the scope of implementation class MAP3. All the softwares are implemented under the real-time multitask OS for real-time application of the Mini-MAP and they are loaded into PROMs at the network board of GEM. We tested the LLC functions to make use of a protocol analyzer for the token-passing protocol. Also the MMS conformance test was carried out by exchanging primitives between GEM and a MMS product that had already passed the conformance test. Therefore GEM is proposed as a network tool of Computer Integrated Manufacturing (CIM) to integrate PDs which don't support MAP functions.

  • PDF

Development of Sensor and Signal Duplicator for Building Automation (빌딩 자동제어용 센서 및 신호의 듀플리케이터(Duplicator) 개발)

  • Jang, Kyeong-Uk;Lee, Yong-Min;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.184-187
    • /
    • 2016
  • In this paper, we propose the sensor and the signal duplicator for the automatic building control. Developed duplicator realizes the sensor data collection apparatus and mimics the measured data and, thus, reduces the construction cost by using logical communication layer. Furthermore, the system supports the open protocols and can be associated with HMI(Human Machine Interface) used on the market. Developed duplicator is proved to be functional within the real environment. Measurement error rate, operating temperature, and operating humidity show very good results by the certified testing apparatus and organization.

Overexpression of GAP Causes the Delay of NGF-induced Neuronal Differentiation and the Inhibition of Tyrosine Phosphorylation of SNT in PC12 Cells

  • Yang, Sung-Il;Kaplan, David
    • BMB Reports
    • /
    • v.28 no.4
    • /
    • pp.316-322
    • /
    • 1995
  • The GTPase activating protein (GAP) can function both as a negative regulator and an effector of $p21^{ras}$. Overexpression of GAP in NIH-3T3 cells has been shown to inhibit transformation by ms or src. To investigate the function of GAP in a differentiative system, we overexpressed this protein in the nerve growth factor (NGF)-responsive PC12 cell line. Two-fold overexpression of GAP caused a delay of several days in the onset of NGF- but not FGF-induced neuronal differentiation of PC12 cells. However, the NGF-induced activation or tyrosine phosphorylation of upstream (Trk, PLC-${\gamma}1$, SHC) and downstream (B-Raf and $p44^{mapk/erk1}$) components of $p21^{ras}$, signalling cascade was not altered by GAP overexpression. Therefore, the change of phenotype induced by GAP was probably not due to GAP functioning as a negative regulator of $p21^{ras}$. Rather, we found that NGF-induced tyrosine phosphorylation of SNT, a specific target of neurotrophin-induced tyrosine kinase activity, was inhibited by GAP overexpression. SNT is thought to function upstream or independent of $p21^{ras}$. Thus in PC12 cells, overexpressed GAP may control the rate of neuronal differentiation through a pathway involving SNT rather than the $p21^{ras}$ signalling pathway.

  • PDF