• 제목/요약/키워드: PLC Modem

검색결과 70건 처리시간 0.021초

제어용 PLC 모뎀을 위한 대기전력 절감 모듈 개발 (A Development of Module Operating on Standby-power Reduction for PLC Control Modem)

  • 김기현;김지홍;김남균;김상철;서길수;김은동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.296-299
    • /
    • 2004
  • This paper introduces a supplementary module reducing tile standby-power of Power Line Communication(PLC) modem, one of the network equipments that take up much of tile stand-by power. This supplementary module consists of three parts, such as a compare part, a control part, and a switch part. This supplementary module controls the power going from the power supply element into PLC modem, which brings about the effect of standby-power reduction. It is assured that over 30% standby-power reduction is estimated when we applied this module to a low-speedy PLC control modem.

  • PDF

전력선통신모뎀의 전자계강도 측정방법 연구 (A Study for the Measurement Method of Electromagnetic Field Strength of Power Line Communications Modem)

  • 장동원
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2006년도 하계학술대회
    • /
    • pp.162-165
    • /
    • 2006
  • This paper describes a measurement method for electromagnetic field strength of power-line communications(PLC) modem. First it outlines the technology used in PLC modems, and the technical regulation being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this protection. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC modem mean that there is no consensus as yet as to how PLC modem components can be made compliant with EMC requirements globally. It is concluded that there is a measurement method according to CISPR standards which satisfy requirements in domestic regulation.

  • PDF

저속 PLC 모뎀을 위한 대기전력 절감 모듈 개발 (A Development of Module Operating on Standby-power Reduction for Low-speedy PLC Modem)

  • 김기현;김지홍;김남균;김상철;서길수;김은동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1537-1539
    • /
    • 2004
  • This paper introduces a supplementary module reducing the standby-power of Power Line Communication(PLC) modem, one of the network equipments that take up much of the stand-by power. This supplementary module consists of three parts, such as a compare part, a control part, and a switch part. This supplementary module controls the power going from the power supply element into PLC modem, which brings about the effect of standby-power reduction. It is assured that over $30\%$ standby-power reduction is estimated when we applied this module to a low-speedy PLC control modem.

  • PDF

듀얼 모드형 고신뢰 PLC 모뎀 칩 설계 및 구현 (Design and Implementation of the Dual-Mode Type Reliable PLC Modem Chip)

  • 이원태;최성수;윤성하;이영철
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.488-493
    • /
    • 2008
  • This paper represents a dual-mode type transmission technique for a high reliable narrow-band power line communication(PLC) modem, and its design and implementation of a system-on-chip(SoC). The proposed transmission technique is based on a Chirp modulation for the purpose of overcoming time variations of power line channel environments in the narrow-bandwidth of the frequency range of 95-145.5 kHz. The designed modem is fabricated utilizing a mixed 0.18 ${\mu}m$ CMOS technology. Especially, according to the power line channel environments the data transmission rate can be selectively changed into 2.5 kbps and 480 bps. The total hardware complexity of the implemented chip is about 50,000 gates, the power consumption is about 26mW, and the operating frequency is up to 5.12 MHz.

전력선통신과 인터넷을 이용한 원격제어 및 검침구현 (Development of Telemetering and Control system using PLC and Web)

  • 최원호;박종연
    • 전자공학회논문지SC
    • /
    • 제40권4호
    • /
    • pp.282-290
    • /
    • 2003
  • 전력선 통신을 이용한 기존의 원격검침 시스템은 설치가 복잡하고 비용이 많이 든다. 현대 국내의 대부분의 아파트 및 다세대주택에 인터넷사업자에 의하여 이미 상용화된 인터넷망이 구축되어 있음에 따라 전력회사의 독자적인 네트워크장비가 아닌 인터넷 사업자에 의하여 펼쳐진 인터넷망을 이용하여 저속 전력선통신 모뎀과 웹서버와의 연결로서 저가이고 구조가 간단하여 시스템의 구성이 간편한 원격검침 및 원격제어 시스템 구성을 목적으로 총 2가지의 하드웨어와 2가지의 소프트웨어를 설계 및 제작하였다.

전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구 (A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC))

  • 김용태;신관우;이윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

비파괴검사 공정자동화를 위한 전력선통신 기반 복합통신장치의 구현 (Implementation of PLC-Based Multi-modem for Process Automation of Non-destructive Inspection)

  • 정준환;전호익;김현식;강석근
    • 한국정보통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.822-828
    • /
    • 2013
  • 본 논문에서는 다양한 종류의 데이터가 발생할 수 있는 비파괴검사의 공정자동화를 위한 복합통신장치를 구현하고 검증한다. 여기서는 검사장비와 센서, 컴퓨터 등에서 발생된 제어신호, 텍스트형 데이터, 영상 데이터를 직렬통신, 이더넷, 동축케이블 등을 이용하여 복합통신장치에 전송하고 통신장치 간은 기간 전송매체인 전력선을 이용한다. 이를 위하여 구현된 장치는 여러 가지 통신이 가능하도록 다양한 포트와 이에 따른 인터페이스를 장착하고 있다. 실험결과 구현된 복합통신장치는 신호파형의 왜곡이 거의 없으면서도 일정한 전송속도를 유지하는 것으로 나타났다. 또한 주변 환경의 극심한 온도변화에 대해서도 정상적으로 동작함을 검증하였다. 따라서 본 논문에서 구현된 복합통신장치는 다양한 종류의 데이터가 발생될 수 있는 비파괴검사 공정의 자동화를 위한 전력선통신 기반 통신네트워크 구축에 크게 기여할 수 있을 것으로 판단된다.

Broadband Impedance Matching Circuit Design for PLC Coupler Using Tchebycheff Equalizer

  • Kim, Gi-Rae;Tangyao, Xie
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.113-118
    • /
    • 2009
  • This paper is about design broadband impedance matching circuit for Coupler to improve power transfer efficiency in the power line communication (PLC) system. The Tchebycheff gain function algorithm is represented to design broadband matching circuit. A practical PLC Coupler impedance matching circuit is designed, and the characteristics for S11 and S21 of PLC coupler are enhanced comparing with unmatched one. This is done by maximizing the power transfer gain from modem to the load.

PLC 기반 인적 재난 방지 및 위치 정보 모니터링 시스템 구현 (Implementation of the Man-made Disaster Prevention and Localization Information Monitoring System based on PLC)

  • 윤선태;박기원;고봉진
    • 한국항행학회논문지
    • /
    • 제14권3호
    • /
    • pp.384-390
    • /
    • 2010
  • 산업현장 내 작업장에서 재난, 사건 사고 등이 빈번하게 발생됨에 따라 그에 대한 예방, 복구, 대비 대응 등 재난 안전 관리의 요구 사항들이 증가되고 있다. 이런 재난들을 방지하기 위한 방법으로 PLC 기반 무선 센서 네트워크를 이용하였으며, 시스템 구성은 작업장 내의 각 작업 구역마다 PLC Modem과 Zigbee를 결합한 메인노드를 설치하여 작업자에 부착된 무선 센서노드들과 무선으로 센서 값을 송수신하고, 메인노드에 전송된 데이터 값은 PLC를 통해 모니터링 PC로 전송하게 된다. 본 논문에서 구현된 시스템을 통해 실시간 상황 및 재난 위치정보를 파악하여 재난을 예방하고 피해를 줄일 수 있으리라 기대한다.

일반 환경에서 마스터-슬레이브 기반 전력선 통신 모뎀의 성능 시험 및 분석 (Performance Test and Analysis of Master-Slave Based PLC Modem in General Building)

  • 황민태;하현석;이재호
    • 한국멀티미디어학회논문지
    • /
    • 제8권5호
    • /
    • pp.660-669
    • /
    • 2005
  • 본 논문에서는 국내에서 개발된 마스터-슬레이브 기반의 10Mbps급 전력선 통신 모뎀을 전력선 통신 시범 서비스 대상의 일반 가정에 설치한 다음 전력선 통신의 네트워크 성능 및 멀티미디어 수용 능력을 측정하고 그 결과를 분석하였다. 본 연구를 위한 테스트베드는 하나의 마스터 모뎀과 3개의 슬레이브 모뎀으로 구성되며, 이들 간에 RFC 2544에서 규정한 처리율, 지연시간, 그리고 프레임 손실율을 측정하였으며, 아울러 RFC 2285에서 규정하고 있는 일대다 및 다대일의 처리율 시험을 실시하였다. 성능 시험 및 분석 결과 여러 노이즈 소스가 있는 일반 가정에서 전력선 통신모뎀의 성능은 대체적으로 단위 프레임의 크기가 클수록, 전송 속도가 느릴수록 좋은 성능을 나타냄을 알 수 있었다. 이러한 성능 분석 결과는 노이즈 소스가 통제된 환경에서의 성능 분석 결과와 비교하여 노이즈 소스가 실제 성능에 어떠한 영향을 미치는 지를 파악하는 용도로 사용될 수 있다.

  • PDF