• Title/Summary/Keyword: PHC pile

Search Result 176, Processing Time 0.021 seconds

Analysis on the Lotting Price Fluctuation of the Multi-Family Attached House According to the Construction Material Cost Variation (건설자재 가격 변동에 따른 공동주택 분양가 변화 분석)

  • Choi, Yeol;Yim, Ha Kyoung;Park, Bong Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6D
    • /
    • pp.753-760
    • /
    • 2009
  • This study analyzed the fluctuation of the construction material cost from 2001 to 2008 in Busan to examine the effect of the fluctuation of the construction material cost on lotting price of the multi family attached house. The major findings are as follow. First, as the result of the analysis on four materials such as reinforced bar, remicon, PHC piles, Copper Tubes, those take largest portion of construction cost, it was found that the there is wide difference in price fluctuation of the each materials. The reinforced bar and Copper Tubes showed high price increase by an average 14.03% and 14.91% per year while remicon, PHC piles remained almost unmoved by an average 0.86% and 2.41%. Second, According to the result of the analysis on the mutuality between the fluctuation of the construction material cost and the lotting price of the multi-family attached house, it was found that the fluctuation of the construction material cost have the most enormous effect on the sale price of the multi-family attached house, when there is 3 month time lag in reinforced bar, remicon, PHC piles, Copper Tubes, commonly. Also this mutuality continues to 6 month, 9 month and 1 year, although it decrease a little bit.

Behavior of bearing Capacity of Piles with an Extended Head by Model Tests (모형실험에 의한 선단확장파일의 지지력 특성)

  • Yoo, Chung-Sik;Kim, Sun-Bin;Lee, Bong-Won;Kim, Young-Hun;Byun, Jo-Seph;Heo, Kab-Soo;Song, Ki-Yong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.536-545
    • /
    • 2006
  • In this study the behavior of piles with an extended head is invested experimentally using reduced-scale model tests. Special attention is given to verifying the increase of end bearing capacity of piles with spreading head. Model piles and extended head plates made of steel pipe were used in this study. Bearing capacity of piles is regarded as only end bearing capacity. The study analyzed the tendency of single and group pile of bearing capacity compared with the existing PHC pile, and examined optimum effect of extended head.

  • PDF

Bending characteristics of Prestressed High Strength Concrete (PHC) spun pile measured using distributed optical fibre strain sensor

  • Mohamad, Hisham;Tee, Bun Pin;Chong, Mun Fai;Lee, Siew Cheng;Chaiyasarn, Krisada
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.267-278
    • /
    • 2022
  • Pre-stressed concrete circular spun piles are widely used in various infrastructure projects around the world and offer an economical deep foundation system with consistent and superior quality compared to cast in-situ and other concrete piles. Conventional methods for measuring the lateral response of piles have been limited to conventional instrumentation, such as electrical based gauges and pressure transducers. The problem with existing technology is that the sensors are not able to assist in recording the lateral stiffness changes of the pile which varies along the length depending on the distribution of the flexural moments and appearance of tensile cracks. This paper describes a full-scale bending test of a 1-m diameter spun pile of 30 m long and instrumented using advanced fibre optic distributed sensor, known as Brillouin Optical Time Domain Analysis (BOTDA). Optical fibre sensors were embedded inside the concrete during the manufacturing stage and attached on the concrete surface in order to measure the pile's full-length flexural behaviour under the prescribed serviceability and ultimate limit state. The relationship between moments-deflections and bending moments-curvatures are examined with respect to the lateral forces. Tensile cracks were measured and compared with the peak strains observed from BOTDA data which corroborated very well. By analysing the moment-curvature response of the pile, the structure can be represented by two bending stiffness parameters, namely the pre-yield (EI) and post-yield (EIcr), where the cracks reduce the stiffness property by 89%. The pile deflection profile can be attained from optical fibre data through closed-form solutions, which generally matched with the displacements recorded by Linear Voltage Displacement Transducers (LVDTs).

Estimation of Flexural Strength of Hollow Prestressed Concrete Filled Steel Tube Piles (긴장력이 도입된 중공형 콘크리트 충전 강관말뚝의 휨강도 산정)

  • Paik, Kyu-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.91-100
    • /
    • 2019
  • Hollow prestressed concrete-filled steel tube (HCFT) piles, which combines PHC piles inside thin-wall steel tubes, were developed to increase the flexural strength of the pile with respect to the lateral load. Since P-M curves are needed for evaluating the structural safety of piles when applying HCFT piles to fields, equations for plotting P-M curves of HCFT piles in limit states were proposed. When the yield strength is applied to the steel tube and PC steel bar of HCFT piles, the proposed equations significantly underestimated the flexural strength of HCFT piles. Unlike the flexural strength test results, the proposed equations also provide greater flexural strengths for 12 mm thick steel pipe piles with the same diameter than for HCFT piles. However, when the ultimate strengths are used instead of the yield strengths for the steel tube and PC steel bar, the proposed equations provide the flexural strengths very close to the flexural strength test results.

Development of Non-Contact Penetration Measuring Device for Pile Driving Workers (항타 시공 작업자를 위한 비접촉식 관입량 측정기 개발)

  • Kim, J.K.;Kong, Y.K.;Choi, K.H.;Cho, M.U.;Kim, S.Y.;Kim, M.J.;Lee, J.H.;Park, Chae Won
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.58-63
    • /
    • 2020
  • At the construction site of the driving site, the pile rebound and penetration measurements are performed manually to determine the end point of the driving operation, thereby causing the measurer to be exposed to a death accident. In this study, in order to eliminate the risk of this work, a non-contact penetration measuring device was developed and usability evaluation was conducted. The penetration measuring device is manufactured based on the ultrasonic sensor, and can be combined with the pile to deliver the data in real time, and the delivered data can be output in real time on the portable PC and the final penetration can be calculated. Usability evaluation on the device was conducted by comparison with manual work. Usability evaluation was largely evaluated on measured values, subjective comfort, and body parts comfort. The result of the measured value tended to overestimate the value measured manually by the measuring device, which is similar to the previous research. In terms of subjective comfort and body part comfort, overall satisfaction was higher than the manual method when using the measuring device. Taken together, these results indicate that it is possible to use the rudder measuring device in place of manual work in the construction site, and it is judged that the worker's comfort is greatly increased by using the measuring machine. The results of this study suggest that the use of non-contact measuring device in the field can be used as basic data to support them.

Estimation of resistance coefficient of PHC bored pile by Load Test (재하시험에 의한 PHC 매입말뚝의 저항계수 산정)

  • Park, Jong-Bae;Kwon, Young-Hwan
    • Land and Housing Review
    • /
    • v.8 no.4
    • /
    • pp.233-247
    • /
    • 2017
  • In Europe and the USA, the use of limit state design method has been established, and the Korea Ministry of Land, Transport and Maritime Affairs has implemented the bridge substructure design standard based on the critical state. But Korean piling methods and ground conditions are different from Europe and USA, the limit state design method can not be used immediately. In this study, the resistance coefficient was proposed by comparing and analyzing the results of the static load test(9 times) and dynamic load tests(9 times of EOID and 9 times of Restrike) with the bearing capacity calculated by Meyerhof(LH design standard, Road bridge design standard) method and surcharge load method(using Terzaghi's bearing capacity coefficient and Hansen & Vesic's bearing capacity coefficient). The previous LHI study showed the resistance coefficient of the LH design standard was 0.36 ~ 0.44, and this research result showed the resistance coefficient was 0.39 ~ 0.48 which is about 8% higher than the previous study. In this study, we tried to obtain the resistance coefficient mainly from the static load test and the resistance coefficient was 0.57 ~ 0.69(Meyhof method : LH design standard) based on the ultimate bearing capacity and the resistance coefficient was 0.49 ~ 0.60(Meyhof method : LH design standard) based on the Davissons bearing capacity. The difference of the resistance coefficient between the static and dynamic load test was greater than that we expected, we proposed the resistance coefficient(0.52 ~ 0.62 : Meyerhof method: LH design standard) using the modified bearing capacity of the dynamic load test. Summarizing the result, the coefficient of resistance obtained from the static and dynamic load tests was 0.35 ~ 0.76, which is greater than 0.3 suggested by the Road bridge design standard, so the economical design might be possible using the coefficient of resistance proposed by this study.

Evaluation of Thermal Response Test of Energy Pile (에너지 파일의 현장 열응답 시험에 관한 연구)

  • Yoon, Seok;Lee, Seung-Rae;Kim, Min-Jun;Go, Gyu-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.4
    • /
    • pp.93-99
    • /
    • 2014
  • Use of geothermal energy has been increased for its economical application and environmentally friendly utilization. Particularly, for energy piles, a spiral coil type ground heat exchanger (GHE) is more preferred than line type GHEs such as U and W shaped GHEs. A PHC energy pile with spiral coil type GHE was installed in an area of partially saturated dredged soil deposit, and a thermal response test (TRT) was conducted for 240 hours under a continuous operation condition. Besides, remolded soil samples from different layers were collected in the field, and soil specimens were reconstructed according to the field ground condition. Non-steady state probe methods were conducted in the lab, and ground thermal conductivity and thermal diffusivity were measured for the different soil layers. An equivalent ground thermal conductivity was calculated from the lab test results and it was compared with the field TRT result. The difference was less than 5%, which advocates the use of an equivalent ground thermal conductivity for the multi-layered ground. Furthermore, this paper also represents an equivalent ground thermal diffusivity evaluation method which is another very important design parameter.

A Case of Change in Pile Foundation By Construction Condition in Site (현장상황을 반영한 말뚝기초의 변경 사례)

  • Park, See-Boum;Oh, Geon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.775-778
    • /
    • 2008
  • 기초의 지지방식 중 깊은 기초로 분류되는 말뚝기초는 일반적으로 고강도의 기성강관(Spiral Steel Pipe)을 재료로 한 말뚝을 사용하는 것이 설계 및 시공측면에서 유리하나, 현재 국내 외의 치솟는 건설원자재 비용 및 고유가에 따른 장거리 운반비용의 증가와 더불어 건설현장에서의 경제적 부담이 상당부분 증가되고 있는 실정이다. 특히, 개발후진국을 비롯한 건설 산업의 국제적 진출에 대한 활기와 더불어 해외현장 변동상황(원자재의 수급 문제에 따른 공기지연 및 경제성) 등을 고려하면 이에 대한 능동적인 대처가 절실할 수 있다. 본 사례는 중동지역 $\bigcirc\bigcirc$조선소의 이러한 현장여건을 고려하여 중 소하중 규모의 크레인 기초에 적용된 말뚝의 구조 해석적 검토와 지역 지반조건을 반영하여 안정하고 현지조달이 가능한 말뚝 재료의 변경을 제안한 경우이다. 본 검토에서는 기초 말뚝의 정역학적 허용지지력과 기초지반 조건을 고려한 항타관입 분석 및 크레인 이동하중을 고려한 응력해석을 실시하여 최대연직력, 모멘트, 전단력, 응력비 등을 비교하였으며, 동일한 검토조건하에서 결과를 바탕으로 변경 가능한 말뚝을 선정하였다. 기초지반에 대한 적정안전율을 갖는 허용지지력 및 구조적 안정성의 확보가 가능한 콘크리트 말뚝으로의 변경이 가능하며 상부하중 규모에 따라 설치간격에 따른 파일본수의 증 감이 발생되었다.

  • PDF

Calculation method for settlement of micropile installed in rock layers through field tests

  • Hwang, TaeHyun;Cho, JungMin;Lee, YeongSaeng
    • Geomechanics and Engineering
    • /
    • v.31 no.2
    • /
    • pp.197-208
    • /
    • 2022
  • Micropiles consisting of steel bars and grouts are commonly used in underpinning methods to reinforce supports or to suppress the subsidence of existing structures. Recently, applications in the field of geotechnical engineering have expanded. Despite the increasing use of micropiles are used, the PHC or steel pile formula is still applied for the settlement amount of micropiles. Compared with field test results, the amount of micropile subsidence obtained from the existing method may result in a very large error in the displacement of the micropile. Therefore, it is difficult to utilize micropiles effectively. Hence, to solve this problem, this study evaluated the behaviors and support characteristics of micropiles through field compression and tensile tests, and proposed a method for predicting the amounts of their subsidence. To confirm the appropriateness of the proposed method, field test results and the results obtained using the proposed method were compared. It was found that the settlement amounts of the micropiles as predicted through the existing method were significantly overestimated (error ≈ 50-80%) relative to the field test results, whereas the settlement errors of the piles predicted through the proposed method decreased (error ≈6-32%). Thus, it is possible to reduce the previously overestimated amount of settlement, and the modified method of this study allows more efficient design than the conventional method.

Mixture Study for Early-age Strength Improvement of NAC-typed High-strength Concrete Piles (NAC 방식 고강도 콘크리트 파일의 초기강도증진을 위한 배합에 대한 연구)

  • Yi, Seong Tae;Noh, Jae Ho;Heo, Hyung Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.58-64
    • /
    • 2012
  • Due to the influence of global oil prices, industrial productivity, which oil consumption is high, was significantly reduced. AC type of high-strength PHC piles is being manufactured through twice the steam curing process and this have resulted in a significant rise for product's manufacturing costs. NAC way other types of file manufacturing process has the advantage of reducing manufacturing costs by a turn of the steam curing. Nevertheless, because the initial strength be poor than that of AC method, shipment is being after the curing period of approximately three days. In addition, the growth of the product enhance with curing period can not be avoided, as a result, cost of inventory is acting as the rise. Piles by the AC method is immediately shipped after curing, damaging problems does not occur when they are introduced to the field site (for example, pile on-site). In the case of NAC, however, at least after the curing period of three days and after expressing the strength of 80 MPa or more, they are shipped on the scene. Therefore, NAC type has problems as follows: (1) increase in moderate inventory holding costs with type and (2) breakage in the field due to lack of strength. In this study, for NAC-typed PHC files, mixing characteristics research for the strength development at 1 day equivalent to AC method were conducted and strength characteristics with changes of original materials were evaluated were also identified.