• Title/Summary/Keyword: PET bottles

Search Result 65, Processing Time 0.027 seconds

Numerical study on the blowing deformation characteristics of a square shaped preform (사각 프리폼 블로우 성형 특성에 관한 수치적 연구)

  • Cho, Seung-Hyun;Song, Min-Jae;Lee, Dong-Won;KO, Young-Bae
    • Design & Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.1-8
    • /
    • 2015
  • This study presents the preform injection molding and the blow molding of the injection stretch-blow molding process for PET bottles. The numerical analysis of the injection molding and the blow molding of a preform is considered in this paper using CAE with a view to minimize the warpage and the thickness. In order to determine the design parameters and processing conditions in injection/blow molding, it is very important to establish the numerical model with physical phenomenon. In this study, we appropriately predicted the warpage, deformation and thickness distribution along the product walls.

  • PDF

Comparison of Mechanical and Interfacial Properties of Carbon Fiber Reinforced Recycled PET Composites with Thermoforming Temperature and Time (열 성형 온도 및 시간에 따른 탄소섬유 강화 재활용 PET 복합재료의 계면 및 기계적 물성 비교)

  • Baek, Yeong-Min;Shin, Pyeong-Su;Kim, Jong-Hyun;Park, Ha-Seung;Kwon, Dong-Jun;Park, Joung-Man
    • Composites Research
    • /
    • v.30 no.3
    • /
    • pp.175-180
    • /
    • 2017
  • Currently, since carbon fiber reinforced plastics (CFRPs) are lightweight and have excellent physical properties, their demand has increased dramatically. Many works have studied the CFRPs based on recycled thermoplastics. In this study, the applicability of recycled composite was evaluated using recycled polyethylene terephthalate (PET). PET was collected from waste materials used in beverage bottles and processed to produce PET films. Optimal thermoforming temperature and time were analyzed by comparing the mechanical properties with forming temperature and time difference for producing PET films. CF mat and PET film were used to determine the suitable parameters for the optimum thermoforming of CF/PET composites. The mechanical properties of each thermoforming condition were verified by bending test. The degree of impregnation of the PET film into the CF mat was evaluated by cross-sectional photographs, whereas the interfacial properties were evaluated by interlaminar shear strength (ILSS). Ultimately, it was confirmed that the thermoforming condition for forming the CF/recycled PET composites yielding the optimal mechanical and interfacial properties was at $270^{\circ}C$ for 5 minutes.

Concentration of Formaldehyde and Acetaldehyde depending on the Time of Storage into Mineral Water (먹는샘물의 보관 기간에 따른 formaldehyde 및 acetaldehyde의 농도 변화)

  • Lee, Youn-Hee;Lee, Jun-Bae;Park, Ju-Hyun;Choi, Ja-Yoon;Ahn, Kyung-Hee;Ahn, Hye-Sil;Kwon, Oh-Sang;Kim, Tae-Seung;Han, Jin-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.281-287
    • /
    • 2011
  • BACKGROUND: According to Korean regulations, bottled waters (BWs) can not be treated with chemical disinfectants like chlorine, so UV and ozone disinfection is applied. During the past several years, chemicals were detected in some BWs, and the public was concerned about the safety of BWs. METHODS AND RESULTS: Mineral waters were stored for 180 days at $25^{\circ}C$ and $50^{\circ}C$, tested acetaldehyde and formaldehyde by HPLC. When mineral waters were put in a PET bottles, the formaldehyde level ranged from 5 to $66{\mu}g/L$ during 180 days at $50^{\circ}C$. While the acetaldehyde level ranged from 31 to $221{\mu}g/L$, it was low than $16{\mu}g/L$ in glass bottle. CONCLUSION(s): This result showed that formaldehyde and acetaldehyde were detected higher in PET bottles than glass bottles, these also increased depending on the time of storage. Concentration of formaldehyde and acetaldehyde could be significantly influenced by the time of storage and temperature.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

A Study on the Origination of Backcountry Litter in Moaksan Provincial Park (모악산도립공원의 산쓰레기 발생특성)

  • Rho, Jae-Hyun;Huh, Joon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.5
    • /
    • pp.64-72
    • /
    • 2007
  • This study investigated the types, forms, and origination of litter found along one hiking course in Moaksan Provincial Park, 'Jungin-ri Course'(entrance-ridge-valley-peak). In addition, a survey was conducted to understand hikers' litter control awareness in order to determine possible backcountry litter control measures. The following are the results of this study: 1. For the litter Sequency investigation, 199 recyclable pieces of litter were found on the mid-slope(61.6%), 89 by the entrance(27.6%), 19 in the valley(5.9%) and 16 on the peak(4.9%). A total of 323 pieces of litter were found. Paper materials were the most common, followed by plastic containers such as PET bottles and yogurt containers. Of particular interest, 288 papers and cans were found on the mid-slope(46.9%). By the entrance, more plastics and bottles were found. 2. There were 614 pieces of flammable litter collected and only 19 pieces of non-flammable. Most of the flammable litter, including snack pacts, plastic bags, processed lumber, cigarette butts, tissues, cigarette boxes, and fabric was found on the mid-slope. 3. Very little food waste was found throughout the whole site proving that the policy prohibiting hikers from cooking and eating at the designated sites has been effective. However, food waste is difficult to find because it naturally decays with time. 4. $X^2$-test was used to find different types of litter and their verified origination frequency. It was found that recyclable litter, and food waste took about 1%. In addition, recyclable litter, especially bottles, was found relatively frequently by the entrance. Flammable litter was found most often at the peak. 5. The questionnaire results showed that 48.2% of the respondents "shorten their hiking journey and purchase food outside the entrance" and 29.6% said that they "bring a packed meal from home". Only 8.2% said that they "cook something when an appropriate location is found". At the Jungin-ri course, a few hikers brought their own food to eat or cook, but most hikers purchased something to eat onsite. 6. The results of the question about having experience littering while hiking showed that 19.3% litter and 79.2% do not. Those that responded "yes" gave various reasons for littering. 63.6% claimed, "there are no designated trash containers". 15.9% said they litter subconsciously. Finally, 3.2% insist that they litter "because food naturally decomposes". 7. As a result of the overall satisfaction according to the Likert scale and the analysis with an average of 14 variables, it was found that the average "toxic litter control convenience" was 2.41 with very low satisfaction. Thus, the results indicate the importance of providing appropriate back country litter control facilities.

An Experimental Study for Recycling of the Waste PET Bottle as a Fine Aggregate for Lightweight Concrete (폐 PET 병을 경량콘크리트용 잔골재로 재활용하기 위한 실험적 연구)

  • Choi Yun-Wang;Moon Dae-Joong;Jung Moon-Young;Cho Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.79-87
    • /
    • 2004
  • The qualify of lightweight aggregate made from waste PET bottle(WPLA) and the workability, the unit weight and strength property of concrete with WPLA were investigated for the purpose of recycling the waste PET bottles as lightweight concrete fine aggregate. This study indicated a good result that WPLA should be replaced with less than $50\%$ of natural fine aggregate. When WPLA was replaced with $50\%$ of natural fine aggregate, the specific gravity and water absorption of mixed fine aggregate were greatly reduced about 23 and $75\%$ respectively in comparison with those of river sand. The quality of WPLA affected on the properties of lightweight aggregate concrete. The workability of fresh concrete with WPLA(WPLAC) was improved with increasing the replacement ratio of WPLA and water cement ratio. Slump increasing ratio of the former showed about $45 {\~} 120\%$ because that a specific gravity of fine aggregate was decreased from 2.6 to 1.7. The unit weight of concrete with $75\%$ WPLA was decreased about $17\%$ in comparison with that of control concrete. Furthermore, the compressive strength of concrete with 25 and $50 \%$ WPLA at the age of 28 days increased higher than 30 MPa regardless with water cement ratio (W/C=45, 49 and $53\%$) of this study. Specific strength of concrete with $25\%$ WPLA, $15.11{\times}10^3 MPa{\cdot}m^3/kg$, was higher than that of contro concrete in water cement ratio of $49\%$. The compressive strength-splitting tensile strength ratio and compressive strength-modulus of elasticity ratio of WPLAC were similar to that of nomal lightweight aggregate concrete. This results showed a good estimation that WPLA will be able to recycled as a fine aggregate for lightweight concrete.

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Study on Water Quality of Spring Water in Seoul (서울지역 약수터의 수질특성에 관한 연구)

  • Kim, Kwang-Rae;Gil, Hae-Kyung;Kim, Hyun-Kook;Kim, Eun-Sook;Roh, Bang-Sik;Hong, Ju-Hee;Lee, Jin;Kim, Jeong-Yeon;Lee, Man-Ho;Eom, Seok-Won;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.99-106
    • /
    • 2010
  • We investigated springs in Seoul in 2009 to know the change of water quality according to storage method of spring water, the concentration of chemical compounds and their correlation. Even spring water that originally satisfied national standard for drinking water could be exceeded national standard for drinking water by storage method such as storage bottle, temperature and period; especially used PET bottles could affect the increase of total colony counts. Therefore, spring water is desirable to be consumed on the spot, or to be stored in sterilized bottles in refrigerator rather than room temperature at home, and also to be consumed shortly not exceeding 24 hours. Total colony counts, coliform, yersinia, $F^-$, $Cl^-$, $NO_3^--N$, hardness, total Solids, pH, color and Al were exceeded national standard for drinking water at some springs. The result of correlation analysis shows that hardness and total solids, which are caused by several ionic compounds, had relatively high correlations with other chemical compounds.

An Analysis of Environmentally Conscious Consumers' Features and Their Awareness of Green Fashion Products - Focusing on female residents of Seoul(Comparison between 1999 and 2007) - (그린 패션제품에 대한 환경친화적 소비자의 특성 및 인지도분석 - 서울시 거주여성을 중심으로(1999년도와 2007년도의 연구비교) -)

  • Lee, Jong-Sook;Yang, Lee-Na;Choi, Na-Young
    • Fashion & Textile Research Journal
    • /
    • v.9 no.4
    • /
    • pp.401-408
    • /
    • 2007
  • The study aims to examine consumer awareness of green fashion products and demographic characteristics by subdividing environmentally conscious consumers of such products in the current domestic fashion market. It then compares the result with the characteristics of environmentally conscious consumers studied by 1999 in order to understand the trend of the consumer group in the fashion market and to promote the use of green fashion products. Marketing strategies for green fashion products suggested by the study are as follows: First, fashion firms are required to develop and publicize shops selling recycled or second-hand clothing that environmentally conscious consumers show constant interest. For instance, clothing patterns may be developed to enable consumers to make their kids' clothing easily at home, and various garments made from recycled materials may stimulate environmentally conscious consumers' desire to buy. Particularly, advanced technologies should be developed and publicized to manufacture garments that can excel existing ones made of normal materials in their features in order to satisfy consumers' interest in clothing made from recycled PET bottles. In addition, various natural dyes should be developed to decrease water pollution. Second, it seems imperative to develop clothing made of recycled knitted apparel that attracts consumers' interest more than ever, fashionable multi-purpose clothing, and environmentally friendly materials. As the use of natural fur or leather can cause the endangerment of wild animals and the destruction of the ecosystem, synthetic fur or leather may be used to develop sophisticated products with the same texture as real ones to attract environmentally conscious consumers' interest.

Attractants and Trap Development for Ussur Brown Katydid, Paratlanticus ussuriensis (Orthoptera : Tettigoniidae) (갈색여치의 유인물질 탐색과 트랩개발)

  • Noh, Doo-Jin;Yang, Jeong-Oh;Moon, Sang-Rae;Yoon, Chang-Mann;Kang, Shin-Ho;Ahn, Ki-Su;Kim, Gil-Hah
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.3
    • /
    • pp.256-261
    • /
    • 2008
  • Recently, Ussur brown katydid outbreaks caused a serious pest problem in areas of Yeongdong, Chungbuk. This study was performed to control the pest with environment-friendly method. Trap was made of PET plastic bottles that easily found near farmhouse. Attractant materials such as oak (Quercus acutissima) leaf, fruits (peach, apple, grapefruit and pear) sarcocarp or its juices, rice wine (makgeolli) and fish meal were directly applied into the manufactured trap and investigated for the attraction efficacy compared with the funnel trap. During one day, manufactured trap (fish trap) attracted the Ussur brown katydid more than funnel trap. The efficacy of attractant materials were as follows: peach juice (32.7 adults) > rice wine+fish meal (31.3 adults) > rice wine (27.0 adults) > pear juice (19.0 adults) > apple juice (17.2 adults) > fish meal (16.7 adults) > grapefruit juice (14.4 adults) > oak leaf (2.3 adults). The attractive efficacy of fruit juices to ussur brown katydid was more than fruit carcocarps, and the trap hangover 1m in height more than that on ground. The composition of rice wine and fish meal prolonged its efficacy when treated with disinfectant.