• Title/Summary/Keyword: PET Scan

Search Result 253, Processing Time 0.026 seconds

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

A Significant Discrepancy of Uptake between I-131 MIBG and F-18 FDG in a Patient With Malignant Paraganglioma (I-131 MIBG와 F-18 FDG 섭취의 불일치를 보였던 악성 부신경절종 1례)

  • Kim, Jong-Su;Kim, Hyun-Keun;Choi, Kyu-Young;Park, Hyung-Ki;Kim, Eun-Sil;Kim, Yun-Kwon;Kim, So-Yon;Kim, Young-Jung;Lee, Hyo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.247-251
    • /
    • 2007
  • A 38-year-old man who was diagnosed with malignant paraganglioma underwent computed tomography (CT) and I-131 metaiodobenzylguanidine (MIBG) san. CT showed extensive lymph node enlargement in right iliac area and retroperitoneum with severe hydronephrosis and mass on posterior bladder wall. However, I-131 MIBG scan didn't showed abnormal uptake. He also underwent F-18 fluorodeoxyglucose (FDG) positron emisson tomography/CT for localizing accurate tumor site. F-18 FDG PET/CT showed multiple metastases of left supraclavicular, hilar, mediastinal para-aortic, inguinal, right iliac lymph nodes, lung, vertebrae, and pelvis. There are a few reports showing that the F-18 FDG PET/CT is helpful for staging and localizing tumor site of patients who are diagnosed with negative on the MIBG scans. Thus, we report a case with paraganglioma which showed negative I-131 MIBG scan, but revealed multiple intense hypermetabolic foci in F-18 FDG PET/CT.

Small Animal PET Imaging Study of 68Ga-BAPEN (68Ga-BAPEN 소동물 PET영상 연구)

  • Kim, Ji-Who;Lee, Jae-Sung;Yang, Bo-Yeun;Kim, Su-Jin;Kim, Joong-Hyun;Jeong, Jae-Min;Lee, Dong-Soo
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.172-177
    • /
    • 2011
  • The purpose of this study was to analyze $^{68}Ga$-BAPEN dynamic PET image in rat myocardium to evaluate potential of this radiotracer as a perfusion imaging agent. Animal PET/CT scan was done in 9 rats during 120 minutes. Especially we synthesized $^{68}Ga$-BAPEN with kit which is simple and low cost method. PET images showed the in vivo dynamic distribution of $^{68}Ga$-BAPEN in the chest region of rats. Initially $^{68}Ga$-BAPEN PET images showed aorta and liver activities and a few minutes later, $^{68}Ga$-BAPEN moved to myocardium. Regions of interest were drawn on myocardium, liver, lung and blood pool. Time-activity curves showed significant uptake of $^{68}Ga$-BAPEN in myocardium. The contrast ratios of myocardial to blood pool, lung and liver at 60 minutes after injection were 1.66, 2.82 and 0.60. To estimate accurate kinetic parameters, 60 minutes after injection was required to PET scan as myocardium image contrast ratios reached to constant values. As a result, $^{68}Ga$-BAPEN would be suitable radiotracer for PET which can applied to diagnosis of myocardial perfusion diseases after further preclinical and clinical investigations.

Usefulness Evaluation of Open Mouth View when PET/CT scan In Tongue Cancer Patients (Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가)

  • Kim, Jae Hwan;Yun, Jong Jun;Jung, Ji Wook;Kim, Jung Wook;Hwang, Ju Won;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.14-20
    • /
    • 2016
  • Purpose Tongue cancer is 1.8% of all cancer tumors occur in the tongue, it is known that the high incidence enough to account for 75% of oral cancer conducted a PET / CT examination for early diagnosis, metastasis, staging, etc. and. Tongue when PET / CT scan of a cancer patient and a Torso taken to close mouth lesions if the condition was caused due to the overlapping or corresponding artifacts are not clearly observed. The purpose of this study is to evaluate the changes that occur during PET / CT scan with open mouth and its usefulness under. Materials and Methods From June 2015 to March 2016 complained of herein by May 21 had received a diagnosis of tongue cancer underwent PET / CT scan patients were treated with a target (16 males, 5 female). The first was taken to close mouth Torso state, it was taken to add 1 bed open mouth condition. Tumor (T), measuring the Normal Tongue (NT), Lymph Node (LN) standard intake coefficient by setting a region of interest in the (standardized uptake value, SUV) SUVmean, the average value was measured SUVmax, drawn to each region of interest 3 times and Background (Carotid artery) was out of the SUV. In Chapter 3 of the slice to the tumor clearly visible by setting the region of interest to measure the change Tumor size was calculated average value. Gross Image resolution assessment were analyzed statistically through were divided into 1-5 points by the Radiation 7 people in 2, more than five years worked in specialized nuclear medicine compare to proceed with the blind test nonparametric test (wilcoxon signed rank test). (SPSS ver.18) Results $SUV_{mean}$ T's were in close mouth $5.01{\pm}2.70$ with open mouth $5.48{\pm}2.88$ (P<0.05), $SUV_{max}$ were respectively $8.78{\pm}5.55$ and $9.70{\pm}5.99$ (P<0.05). $SUV_{mean}$ in the NT were respectively $0.43{\pm}0.30$ and $0.34{\pm}0.24$ (P=0.20), $SUV_{max}$ was $0.56{\pm}0.34$ and $0.45{\pm}0.25$ (P=0.204). LN $SUV_{mean}$ were respectively $1.62{\pm}1.43$ and $1.69{\pm}1.49$ (P=0.161), $SUV_{mean}$ was $2.09{\pm}1.88$ and $1.99{\pm}1.74$ (P=0.131). Tumor size change is close mouth $4.96{\pm}4.66cm^2$ $5.33{\pm}4.64cm^2$ with 7.45% increase was (P<0.05), gross image resolution evaluation is $2.87{\pm}0.73$, $3.77{\pm}0.68$ with open mouth examinations 30.5% increase was (P<0.05). Conclusion Tumor SUV on the changes that had an increase in open mouth during inspection, the normal tongue and lymph node, but there was no significant difference in the change slightly. It is also one open mouth PET / CT scan will provide improved image to all patients with tongue cancer, but it could be confirmed that similar overall through the blind test, or tumor size changes and showing a high resolution image. It can be the perfect alternative method for problems that occur when the close mouth Open mouth PET / CT scan, but is believed to be through the open mouth to observe the boundary of overlapping or tumor of the oral cavity other structures a little more clearly. Tongue cancer patients how to recommend that the shooting further open mouth PET / CT.

  • PDF

Analysis on Early Detection of Lung Cancer by PET/CT Scan

  • Wang, Huo-Qiang;Zhao, Long;Zhao, Juan;Wang, Qiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2215-2217
    • /
    • 2015
  • Background: This systemic analysis was conducted to to evaluate the application value of positron emission tomography/computed tomography (PET/CT) in early diagnosis of lung cancer. Methods: Clinical studies evaluating the application value of PET/CT for patients underwent PET/CT imaging. The histological diagnosis served as the standard of truth. Results: Four clinical studies which including 1330 patients with pulmonary spaceoccupying lesions were considered eligible for inclusion. Systemic analysis suggested that, in all 1330 patients, pooled sensitivity was 98.7% (1313.2/1330) and specificity was 58.2%(276.85/476). Conclusion: This systemic analysis suggests that integrated PET/CT imaging provides high sensitivity, and reasonably high specificity, and could be applied for early diagnosis of lung cancer.

Sequential Change of Hypometabolic Metastasis from Non-small-cell Lung Cancer on Brain FDG-PET/CT (연속적인 FDG-PET/CT 검사에서 섭취 감소로 관찰된 비소세포암의 뇌전이)

  • Park, Soon-Ah;Yang, Sei-Hoon;Yang, Chung-Yong;Choi, Keum-Ha
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.505-507
    • /
    • 2009
  • A 60-year-old woman, who had non-small-cell lung cancer (NSCLC) in left lower lobe underwent brain F-18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for evaluation of cerebral metastasis. On follow-up FDG-PET/CT, only hypometaolic lesion was detected and progressed in right frontal lobe at 6 months and 10 months, later. Hypermetabolic metastasis was not detected even at last scan time of FDG-PET/CT. Brain MRI showed brain metastasis in right frontal lobe. As might be expected, the physician should take cerebral metastasis into consideration even though there is only hypometabolic change on subsequent FDG-PET/CT in patients with NSCLC.

Case Report of Prostate Cancer Patient with Only Lymph Node Involvement on F-18 FDG PET/CT

  • Jung, Hyun Jin;Kang, Sungmin
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.391-395
    • /
    • 2018
  • We report a case of a patient with locally advanced prostate cancer who had only lymph node involvement without bone metastasis on F-18 FDG PET/CT. A 62-year-old Korean male was admitted to our hospital due to dysuria. His PSA level on admission was 79.35 ng/mL. A transrectal ultrasound-guided prostate biopsy confirmed prostate cancer and his Gleason score was 10 (5+5). F-18 FDG PET/CT demonstrated a hypermetabolic mass lesion with SUVmax 7.0 in the prostate and hypermetabolism with SUVmax 4.7 of the abdominal and pelvic lymph nodes. Tc-99m HDP bone scan showed no significant bone metastasis. The patient underwent hormonal therapy for 9 months. Follow-up F-18 FDG PET/CT showed significantly reduced size and FDG uptake in the prostate and abdominal and pelvic lymph nodes. In this case, treatment monitoring with F-18 FDG PET/CT showed decreased mass size and FDG uptake in the prostate and abdominal and pelvic lymph nodes.

Hypermetabolism of Compensatory Laryngeal Muscles in Unilateral Vocal Cord Palsy: Comparison Study between Speech and Silence with Normal Subjects by Co-registered PET-CT Fusion Images (일측 성대마비 환자의 보상기전에 관여하는 후두내근육 : PET-CT 융합 영상을 사용한 정상군과의 발성시 및 비발성시의 비교)

  • Pai, Moon-Sun;Kim, Hyon-Kyong;Kim, Han-Su
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • Purpose: There are a few case reports on asymmetric vocal cord uptake on FDG-PET in patients with unilateral vocal cord paralysis, which could be a potential pitfall in the interpretation of FDG-PET images. We evaluated the metabolic activity of laryngeal muscles of patients with unilateral vocal cord paralysis in comparison to normal controls during both speech and silence. Methods: Eleven patients with unilateral vocal cord palsy (thyroldectomy=7, lung cancer=1, others=3) and 12 normal controls underwent FDG-PET with usual protocol. They were divided into two groups respectively; one group read books aloud for 20 minutes (phonation group) and the other kept silence (non-phonation groups) after FDG injection. Recent neck CT scan were co-registered with FDG-PET to produce PET-CT fusion images to elaborate small laryngeal muscles. Results: In patients with unilateral vocal cord palsy, contralateral non-paralyzed vocal cord showed hypermetabolism mainly on thyroarytenoid muscle, more intensely with phonation group ($SUV=5.88{\pm}2.65$) than with non-phonation group ($SUV=2.30{\pm}0.39$). Normal control subjects showed hypermetabolism ($3.68{\pm}0.96$) in interarytenoid muscle and symmetric mild hypermetabolism in both lateral cricoarytenoid muscles in only phonation group. Conclusion: FDG-PET with fusion images using CT scan in patients with unilateral vocal cord paralysis showed hypermetabolism of contralateral non-paralyzed thyroarytenoid muscle, suggesting compensatory action during phonation. Phonation durung FDG PET study enhanced FDG uptake on different laryngeal muscles between patients with unilateral vocal cord paralysis and normal subjects.

Conceptual Study of Brain Dedicated PET Improving Sensitivity

  • Shin, Han-Back;Choi, Yong;Huh, Yoonsuk;Jung, Jin Ho;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.236-240
    • /
    • 2016
  • The purpose of this study is to propose a novel high sensitivity neuro-PET design. The improvement of sensitivity in neuro-PET is important because it can reduce scan time and/or radiation dose. In this study, we proposed a novel PET detector design that combined conical shape detector with cylindrical one to obtain high sensitivity. The sensitivity as a function of the oblique angle and the ratio of the conical to cylindrical portion was estimated to optimize the design of brain PET using Monte Carlo simulation tool, GATE. An axial sensitivity and misplacement rate by penetration of ${\gamma}$ rays were also estimated to evaluate the performance of the proposed PET. The sensitivity was improved by 36% at the center of axial FOV. This value was similar to the calculated value. The misplacement rate of conical shaped PET was about 5% higher than the conventional PET. The results of this study demonstrated the conical detector proposed in this study could provide subsequent improvement in sensitivity which could allow to design high sensitivity PET for brain imaging.

The evaluation of useful on the additional PET/CT Liver scan (PET/CT 검사에서 Gastrointestinal Cancer 환자의 Liver 추가촬영에 대한 유용성 평가)

  • Park, Se Youn;Lee, Hwa Jin;Lee, Mu Seok;Kim, Jung Uk;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.46-48
    • /
    • 2016
  • Purpose The liver one of the most common site for distant metastasis for a variety of tumor, especially of gastrointestinal origin. the purpose of this study was to analyze image quality between standard scan and additional liver scan. Materials and Methods From September 2015 to February 2016. 152 patients were examined undergo gastrointestinal cancer. 32 patients confirmed liver metastasis analyzed same liver ROI level and check the SNR, SUV and T/N ratio Results The $SNR_{mean}$ of standard was $17.7{\pm}10.3$; addition was $22.3{\pm}9.7$ (p<0.05). In $SUV_{max}$ of standard was $6.7{\pm}2.8$; addition was $7.6{\pm}3.2$ (P<0.05). and the T/N ratio of standard was $2.1{\pm}0.6$; addition was $2.5{\pm}0.8$ (P<0.05). Conclusion The $SNR_{mean}$, $SUV_{max}$ and T/N ratio were higher than those on the first scan (P<0.05). The SNRmean showed the highest change rate among the parameters. A additional liver scan is more favorable for the detection of gastrointestinal cancer patients.

  • PDF