• Title/Summary/Keyword: PD-spectrum

Search Result 80, Processing Time 0.026 seconds

Using the TDR in Dielectric for Partial Discharge Signals Detection Method (이종 비유전율에서 TDR을 이용한 PD발생 위치 추적방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1374-1379
    • /
    • 2015
  • Time Domain Reflectometry(TDR) using microwave bands, including broadband spectrum that occurs at the range of rates that start between partial discharge position it easier to make the techniques that could be measured. Partial discharge in the Gas Insulated Switchgear(GIS), the dielectric constant in the band more than GHz different the insulating material if you want to organize, and the insulating material regardless of how partial discharge position in the SF6 gas Partial Discharge by applying the heritability estimated its position, but the position error occurred about 23 percent of the existing way, correct in not suitable location tracking the outbreak PD. This technique the rate of other dielectric that make up the power apparatus heterology is measured at the function to slow the progression of the electromagnetic waves apart by calculating the partial discharge as the location, A simple way to track. Dielectric using other methods proposed new structure can calculate the speed of heritability PD is occurring can measure.

Spectrum Analysis of VHF/UHF PD in Simulated Transformer (모의 변압기의 VHF/UHF PD 스펙트럼 분석)

  • Kim, Duck-Keun;Kim, Jong-Seo;Lim, Yong-Bae;Lim, Jang-Seob;Moon, Chae-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.50-54
    • /
    • 2000
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

The distance and polarization characteristics of electromagnetic wave radiated at needle-to-plane electrodes in Air and complex dielectric (공기 및 복합유전체 갭에서의 방사전자파의 거리 및 편파특성)

  • 김충년;이현동;박광서;박원주;이광식;이동인;이동헌
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.241-245
    • /
    • 2000
  • In this paper, VHF(30~230[MHz]) electromagnetic waves radiated from partial discharge(PD) at two-type electrodes in air are measured and the peculiar patterns of their spectra are reported. Also, the polarization and distance characteristics of electromagnetic wave rediated by PD, were investigated. In case of epoxy insulator in inserted, the noise level of radiated electromagnetic waves is 0.6~6.2[dB] higher than the case in air at below 90[MHz]. The frequency spectrum distribution of radiated electromagnetic waves appears different in the whole frequency range according to the arrangement of antenna.

  • PDF

1H NMR Kinetic Studies for Degradation of Nitramine Explosives Using PdO Nanoparticle (PdO 나노입자를 이용한 니트라민 폭발물 분해반응에 대한 1H NMR 반응속도연구)

  • Kye, Young-Sik;Kumbier, Mathew;Kim, Dongwook;Harbison, Gerard S.;Langell, Marjorie A.
    • Applied Chemistry for Engineering
    • /
    • v.33 no.3
    • /
    • pp.302-308
    • /
    • 2022
  • The PdO nanoparticle with large surface area was selected to solve the environmental pollution problem at fire range caused by high energy explosives research department explosive (RDX) and high melting explosive (HMX). By simulating water pollution, RDX and HMX nitramine explosives were dissolved in water, followed by the degradation reaction at 313 K by adding PdO. In order to measure the degradation reaction rate of explosives, 1H NMR was used, which can monitor the reaction rate without losing sample during reaction, and observe the progress of the reaction through the spectrum. The results showed that the degradation of RDX and HMX by PdO nanoparticles are pseudo-first order reaction. The degradation of explosives compounds were observed via the chemical shift and peak intensity analysis of NMR peaks. The measured rate constants for these reactions of RDX and HMX were 2.10 × 10-2 and 6.35 × 10-4 h-1, respectively. This study showed that the application of PdO nanoparticles for explosives degradation is a feasible option.

Benchmarking on Product Development Curricula of Domestic and Foreign Universities (국내외 대학의 제품개발 교과과정 벤치마킹)

  • Han, Yune-Tech;Jung, Ki-Hyo;Mun, Jung-Tae;You, Hee-Cheon;Chang, Soo-Young;Jun, Chi-Hyuck
    • Journal of Engineering Education Research
    • /
    • v.13 no.3
    • /
    • pp.3-10
    • /
    • 2010
  • Human resources specialized in product development (PD) being essential in industry to enhance their competitiveness in the market with differentiated products, the PD curricula of domestic universities are in need of restructuring to better provide a comprehensive and diverse spectrum of knowledge as well as practical experiences for PD. We compared the PD curricula of selected domestic and foreign universities and identified advanced features of PD curricula. The major portion of the information used in our benchmarking of the seven, three domestic and four foreign, universities is obtained through their official websites. At domestic universities, the PD curricula comes in different sizes and is administered at the departmental level. On the other hand, each foreign university has her own unique form of PD curricula which is formulated on the firm basis of multidisciplinary collaboration among schools of Engineering, Management, and Arts with diversified program options ranging from giving course credits to offering various certificates and degrees. The industrial sponsorship in the form of financial support and mentorship at foreign universities is much more noticeable than at domestic universities. The survey results of the present study can be effectively utilized to develop an effective PD curriculum.

  • PDF

The Fundamental Study About Partial Discharge Detection With The Radiated Electromagnetic Wave Characteristics (방사전자파 특성을 이용한 부분방전 검출의 기초연구)

  • Lee, Sang-Hun;Park, Gwang-Seo;Kim, Chung-Nyeon;Lee, Hyeon-Dong;Song, Hyeon-Jik;Kim, Gi-Chae;Lee, Gwang-Sik;Lee, Dong-In
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.412-417
    • /
    • 2000
  • This paper offer fundamental materials about Partial Discharge(PD) detection by electromagnetic waves. All spectrum data-usually used as grape- can be used as numbers. And then the average of background noise spectrum strength was made. Average value subtract from every data. Then average value appeared, graphed. The graph was compared with the magnitude of charge. The shape of changes is similar, and the change of electric field strength could be seen in one sight. When the magnitude of charge is over than 100[pC], antenna can detect partial discharge. So this method will be very useful to diagnosis of insulation. It the performance of the antenna used in this experiment is analyzed, good results can be obtained.

  • PDF

On-line partial discharge measurement techniques of hydro-generator windings (수력 발전기 권선에서의 운전중 부분방전 측정기법)

  • 황동하;김진봉;김용주;박명수;김택수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

Design of Self-Validation Sensor Using Noise (노이즈를 이용한 자기진단센서 설계)

  • 김이곤;하종필
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.05a
    • /
    • pp.153-157
    • /
    • 2002
  • 자기 진단 센서는 자신의 상태를 스스로 진단하는 기능을 갖는 센서를 말한다. 이러한 기능을 갖기 위해서 자신의 상태를 판단 할 수 있는 정보를 얻는 것이 가장 중요하다. 본 연구에서는 자신의 노이즈 신호만으로 상태를 판단할 수 있는 자기 진단센서의 설계하는 방법을 제안하였다. 웨이브렛 및 ICA 분석기법을 이용하여 자신의 출력 신호로부터 대상목표의 측정물리량을 나타내는 신호성분을 제외한, 센서 자신으로부터 발생하는 특징 노이즈 신호만을 분류한 다음에, 이 신호를 PDS로 정량화하여 특징 데이터를 생성하였다. 실험을 통해 그 타당성을 입증하였다.

  • PDF

Tris(2-methoxyphenyl)phosphine as a Highly Active Ligand for the Synthesis of Biaryls by Suzuki Coupling Reaction

  • Kang, Pill-Seong;Ko, Sung-Bo;Ko, Jang-Myoun;Park, Jeong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2697-2700
    • /
    • 2009
  • A $Pd(OAc)_2/(o-MeOPh)_3P$ system has been developed for the catalytic Suzuki coupling of aryl bromides with arylboronic acids. Our catalyst system covers a broad spectrum of commonly available arylboronic acids and aryl bromides to provide biaryls in very good yields. The catalyst system works very well in the synthesis of sterically hindered biaryls.

Growth and photoluminescence properties of Er : Mg : LiNbO$_3$single crystal fibers by $\mu$-PD method ($\mu$-PD법에 의한 Er : Mg : LiNbO$_3$fiber 결정 성장 및 형광특성)

  • 양우석;윤대호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.6
    • /
    • pp.389-393
    • /
    • 2000
  • High-quality $Er^{3+}$ doped Mg : $LiNbO_3$single crystal fibers were grown by a micro-pulling down ($\mu$-PD) method. Single crystal fibers were pulled down through the nozzle, at a pulling down rate of 0.5 mm/min and using a Pt crucible with a nozzle 1 mm in diameter in air atmosphere. Defects such as bubbles, cracks and inclusions were not detected in any of the grown crystals. The optical transmission of Er : Mg : $LiNbO_3$crystal was measured and the energy levels of $Er_2O_3$ ion could be calculated. The photoluminescence spectrum of crystal fibers showed an energy band emission with the strongest line corresponding to the $^4I_{3/2}{\to}^4I_{15/2}$transition. The concentration dependence of the entire wavelength region emission intensity upon excitation intensity measured emission intensity for the 3 mol% MgO doped fibers was larger than that for the 1, 5 mol% MgO doped fibers.

  • PDF