• 제목/요약/키워드: PD Test

검색결과 463건 처리시간 0.025초

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.

AZ61-xPd (x = 0, 1 and 2 wt%) Mg합금의 미세조직 및 인장특성에 미치는 열처리의 영향 (Effect of Aging Treatment on the Microstructure and Tensile Properties of AZ61-xPd (x = 0, 1 and 2 wt%) Alloys)

  • 김상현;김병호;박경철;박용호;박익민
    • 대한금속재료학회지
    • /
    • 제50권10호
    • /
    • pp.711-720
    • /
    • 2012
  • In this study, the effect of aging treatment on the microstructure and tensile properties of AZ61-xPd (x = 0, 1 and 2 wt%) alloys were investigated. The microstructure of as-cast AZ61-xPd alloys mainly consisted of ${\alpha}-Mg$, $Mg_{17}Al_{12}$ and $Al_4Pd$ phases. After solution treatment, most of the $Mg_{17}Al_{12}$ phases were dissolved into the Mg matrix. Thereafter, $Mg_{17}Al_{12}$ phases were finely formed and distributed near thermally stable $Al_4Pd$ phases and inside the grains through aging treatment at $220^{\circ}C$ during 88 hours. With the aging at $220^{\circ}C$, the peak aged AZ61-xPd alloys showed higher hardness than as-cast and solution treated AZ61-xPd alloys. In particular, the AZ61-1Pd alloy was optimized due to refined $Mg_{17}Al_{12}$ and $Al_4Pd$ phases. Further, the peak aging time was reduced with increasing Pd addition (>1 wt%). Tensile strength was increased by Pd addition at $25^{\circ}C$, $150^{\circ}C$, both as-cast and peak aged AZ61-xPd alloys. After aging treatment, room and high temperature tensile strength were increased more than the as-cast specimens. The AZ61-1Pd alloy especially showed the largest strength increase range. Elongation was decreased with addition Pd at $25^{\circ}C$ and $150^{\circ}C$.

티타늄 및 티나늄-팔라듐 합금의 수소처리에 관한 연구 (A Study on the Hydrogen treatment of It and Ti-pd Alloy)

  • 차성수
    • 대한치과기공학회지
    • /
    • 제15권1호
    • /
    • pp.5-25
    • /
    • 1993
  • Effects of hydrogenation on microstructure and mechanical properties of pure Ti and Ti-0.15Pd alloy have been studied by means of optical microscopy, differential scanning calorimeter(DSC), Xray diffraction and micro vicker's hardness test. Grain size of pure Ti and Ti-0.15Pd alloy decresed largely by hydrogenation finer than that of pure Ti and the grain size refinement was evedent in Ti-0.15Pd alloy than that in pure Ti. Ti-.015Pd alloy carried out solution treatment at 950$^{\circ}C$, the transformation of $\alpha$' martensite was occured. The amount of Hydrogen absorption in Ti-.015Pd alloy was higher than that in pure Ti. Decomposition of hydride in pure titanium and Ti-0.15Pd alloy increased largely by hydrogenation, and micro vicker's hardness of Ti-.015Pd alloy was largely than that of pure Ti by 30% after hydrogenation. The micro vicker's hardness of Ti-0.15Pd alloy after solution treatment and dehydrogenation were higher at $\beta$ phase ranger(950$^{\circ}C$) than that phase range(750$^{\circ}C$).

  • PDF

Characteristics of Mammary Paget's Disease in China: a National-wide Multicenter Retrospective Study During 1999-2008

  • Zheng, Shan;Song, Qing-Kun;Zhao, Lin;Huang, Rong;Sun, Li;Li, Jing;Fan, Jin-Hu;Zhang, Bao-Ning;Yang, Hong-Jian;Xu, Feng;Zhang, Bin;Qiao, You-Lin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.1887-1893
    • /
    • 2012
  • The aim of this study was to detail characteristics of mammary Paget's disease (PD) representing the whole population in China. A total of 4211 female breast cancer inpatients at seven tertiary hospitals from seven representative geographical regions of China were collected randomly during 1999 to 2008. Data for demography, risk factors, diagnostic imaging test, physical examination and pathologic characters were surveyed and biomarker status was tested by immunohistochemistry. The differences of demography and risk factors between PD with breast cancer and other lesions were compared using Chi-square test or t-test, with attention to physical examination and pathological characters. The percentage of PD was 1.6% (68/4211) in all breast cancers. The mean age at diagnosis was 48.1, and 63.2% (43/68) patients were premenopausal. There is no difference in demography and risk factors between PD with breast cancer and other breast cancer (P > 0.05). The main pattern of PD in physical exam and pathologic pattern were patients presenting with a palpable mass in breast (65/68, 95.6%) and PD with underlying invasive cancer (82.4%, 56/68) respectively. The rate of multifocal disease was 7.4% (5/68). PD with invasive breast cancer showed larger tumor size, more multifocal disease, lower ER and PR expression and higher HER2 overexpression than those in other invasive breast cancer (P < 0.05). These results suggested that PD in China is a concomitant disease of breast cancer, and that PD with underlying invasive cancer has more multiple foci and more aggressive behavior compared with other breast invasive cancer. We address the urgent needs for establishing diagnostic and therapeutic guidelines for mammary PD in China.

Pd 나노갭 수소 센서의 신뢰성 연구 (Reliability Test of Pd Nanogap-Based Hydrogen Sensors)

  • 박세영;김원경;이우영
    • 센서학회지
    • /
    • 제29권6호
    • /
    • pp.399-406
    • /
    • 2020
  • Pd nanogap hydrogen sensors were developed using an elastomeric substrate and operated through an on-off mechanism. A 10 nm thick Pd thin film was formed on a polydimethylsiloxane (PDMS) substrate, and 50% of the physical strain was applied in the longitudinal direction to fabricated uniform nanogaps. The initial concentration of the hydrogen gas for the PDMS/Pd films was controlled, and subsequently, the on-off switching response was measured. We found that the average nanogap was less than 50 nm, and the Pd nanogap hydrogen sensors operated over a wide range of temperatures. In particular, the sensors work properly even at a very low temperature of -40℃ with a fast response time of 2 s. In addition, we have investigated the relative humidity and annealing effects.

XLPE 전력케이블의 부분방전 검출을 위한 HPF 적용 시험 (HPF Application Test for PD Detection of XLPE Power Cable)

  • 김정윤;양종경;박노준;최용성;박대희;이용성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.161-165
    • /
    • 2006
  • In this paper, we developed HPF (high pass filter) consists of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested it under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke Probe and oscilloscope (TDS-3054, Tektronix). As a result, we obtained available data showing the decrease of noises in the experiments with the developed HPF from the joint box of 22.9kV distribution line. The result can be adapted to prevent the degeneration of the XLPE power cable, and to observe and diagnosis the underground power transmission cable at the ultra-high voltage.

배전반 설비의 온라인 모니터링 및 진단의 동향 (Trend in Off-Line PD Monitoring with HVAC Testing)

  • 윤주효;홍창일;황종선;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

팔당호 현장수를 이용한 남조류 Anabaena circinalis의 발아 및 성장 잠재력 시험 (Akinete Germination and Algal Growth Potential Test of Cyanobacterium Anabaena circinalis on Different Waters in Lake Paldang)

  • 박명환;임병진;서완범;박채홍;김건희;황순진
    • 생태와환경
    • /
    • 제48권4호
    • /
    • pp.287-295
    • /
    • 2015
  • 본 연구는 2014년 9월과 2015년 3월에 채수한 팔당호 3지점의 현장수 (PD-1, PD-2 및 PD-3)를 이용하여 북한강에서 우점하는 A. circinalis의 휴면포자 발아 및 성장 잠재력을 평가하였다. 질소와 인 농도는 팔당댐앞 (PD-1)과 광동교 (PD-3)에 비교하여 금남리 (PD-2)에서 좀 더 높게 나타났다. 팔당호 3지점의 총질소에 대한 영양상태지수 (TSI)는 65~85의 범위로 나타났으며, 부영양 또는 과영양 상태로 평가되었다. 또한 총인에 대한 영양상태지수(TSI) 값은 49~68의 범위로서, 중영양 또는 부영양 상태로 평가되었다. 휴면포자 발아 잠재력은 영양염 농도가 높은 금남리 지점 (PD-2)에서 좀 더 높게 나타났으며, 영양세포 성장 잠재력도 영양염 농도가 높은 현장수에서 증가하였다.