• Title/Summary/Keyword: PCs

Search Result 1,840, Processing Time 0.031 seconds

Comparison of Irradiated Food with Electron Beam and Gamma-ray by PSL and TL Methods (광자극발광법과 열발광법 분석을 통한 전자선과 감마선 조사식품의 비교 연구)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Yoon, Jin-Ho;Park, Young-Eun;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.258-266
    • /
    • 2013
  • This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or $^{60}Co$ gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around $300^{\circ}C$ with low intensity on non-irradiated samples. Maximum peak in the range of $150-250^{\circ}C$ was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.

The Association of Intra-Annual Cambial Activities of Pinus koraiensis and Chamaecyparis pisifera planted in Mt. Worak with Climatic Factors (월악산에 식재된 잣나무와 화백나무의 형성층 활동과 기후인자와의 관계)

  • Seo, Jeong-Wook;Choi, En-Bi;Ju, Jeong-Deok;Shin, Chang-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.43-52
    • /
    • 2017
  • This study was fulfilled to verify the durations of cambial activity and analyze the associations of degree days and precipitation with the initiation of cambial activity and intra-annual wood formation for Pinus koraiensis and Chamaecyparis pisifera planted at Mt. Worak, respectively, by monitoring of their intra-annual cambial activities. And more, the reason was also analyzed why the DBH of Chamaecyparis pisifera known as planted in the same year could be classified as two groups (CPL: ${\phi}30cm$, CPS: ${\phi}15cm$). The intra-annual cambial activity was monitored using mini-cores (${\phi}2mm$) and they were collected in 2-week interval between April and October. However, between April and May and between middle September and October expected as the initiation and cessation of the cambial activity, respectively, it was fulfilled in 1-week interval. The average number of tree rings for PK (30) was less than CPS (37) and CPL (38), whereas the average ring width of PK (4.12 mm) was wider than CPS (1.84 mm) and CPL (3.97 mm). In the comparison of ring widths between CPL and CPS, CPL was 2.13 mm wider than CPS, however, excepting CPS 1 (0.83 mm), the average ring widths of CPS 2 (2.42 mm) and CPS 3 (2.73 mm) in the last 3 years were close to the average of CPL (2.71 mm). The initiation of cambial activity for PK was between 1 and 21 April, which was 1 week earlier than CPL and CPS (excepting CPS 1) and the cessation was between 1 and 22 September. The longest growing season therefore was 157.3 days (${\pm}3.3$) and it was longer than CPL ($145.7{\pm}6.6days$) and CPS ($148.0{\pm}15.1days$). In CP groups there were wide variations for the cessation of cambial activity and also there were the meaningful linear relationship between the growing seasons and the ring widths (r = 0.69, p < 0.064). The cambial activity in PK was initiated when degree days were between 99 and 134 and in CPS (excepting PCS 1) and CPL between 134 and 200. Excepting CPS 3, the false ring was observed in all samples collected on 21 July when drought stress was high due to low precipitation from June to the beginning of July.

A development of DS/CDMA MODEM architecture and its implementation (DS/CDMA 모뎀 구조와 ASIC Chip Set 개발)

  • 김제우;박종현;김석중;심복태;이홍직
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1210-1230
    • /
    • 1997
  • In this paper, we suggest an architecture of DS/CDMA tranceiver composed of one pilot channel used as reference and multiple traffic channels. The pilot channel-an unmodulated PN code-is used as the reference signal for synchronization of PN code and data demondulation. The coherent demodulation architecture is also exploited for the reverse link as well as for the forward link. Here are the characteristics of the suggested DS/CDMA system. First, we suggest an interlaced quadrature spreading(IQS) method. In this method, the PN coe for I-phase 1st channel is used for Q-phase 2nd channels and the PN code for Q-phase 1st channel is used for I-phase 2nd channel, and so on-which is quite different from the eisting spreading schemes of DS/CDMA systems, such as IS-95 digital CDMA cellular or W-CDMA for PCS. By doing IQS spreading, we can drastically reduce the zero crossing rate of the RF signals. Second, we introduce an adaptive threshold setting for the synchronization of PN code, an initial acquistion method that uses a single PN code generator and reduces the acquistion time by a half compared the existing ones, and exploit the state machines to reduce the reacquistion time Third, various kinds of functions, such as automatic frequency control(AFC), automatic level control(ALC), bit-error-rate(BER) estimator, and spectral shaping for reducing the adjacent channel interference, are introduced to improve the system performance. Fourth, we designed and implemented the DS/CDMA MODEM to be used for variable transmission rate applications-from 16Kbps to 1.024Mbps. We developed and confirmed the DS/CDMA MODEM architecture through mathematical analysis and various kind of simulations. The ASIC design was done using VHDL coding and synthesis. To cope with several different kinds of applications, we developed transmitter and receiver ASICs separately. While a single transmitter or receiver ASC contains three channels (one for the pilot and the others for the traffic channels), by combining several transmitter ASICs, we can expand the number of channels up to 64. The ASICs are now under use for implementing a line-of-sight (LOS) radio equipment.

  • PDF

A Review of Questionnaire for the Clinical Trials on Chronic Low Back Pain (만성 요통 임상연구에 사용된 설문지 현황 고찰)

  • Kim, Doo-Hee;Shin, Woo-Suk;Lee, Jin-Won;Park, Won-Hyung;Cha, Yun-Yeop;Ko, Youn-Seok;Lee, Jung-Han;Chung, Won-Suk;Shin, Byung-Cheul;Song, Yun-Kyung;Go, Ho-Yeon;Sun, Seong-Ho;Jeon, Chan-Yong;Jang, Bo-Hyoung;Ko, Seong-Gyu
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.95-115
    • /
    • 2013
  • Objectives The aim of this review is to provide fundamental data for low back pain scales which can be used in clinical trial. Methods We investigated the latest studies on chronic low back pain via PubMed. And we also investigated domestic studies through "http://oasis.kiom.re.kr". 95 research papers were analyzed. Scales were classified into pain scale, function scale, generic health status scale and psychological scale. Results 1) According to foreign clinical studies, Visual Analog Scale (VAS) and Numerical Rating Scale (NRS) were used 18 times as pain scale. Oswestry Disability Index (ODI) was used 20 times as function scale, Roland-Morris Disability Questionnaire (RMDQ) was 17, and Hannover Functional Ability Questionnaire (HFAQ) was used 3 times. 36-item Short Form Health Survey (SF-36) was used 13 times as generic health status scale, Euroqol-5 Dimentions Questionnaire (EQ-5D) was 11, and 12-item Short Form Health Survey (SF-12) was used 3 times. Fear-Avoidance Beliefs Questionnaire (FABQ) was used 9 times as psychological scale, Pain Catastrophizing Scale (PCS) and Tampa Scale for Kinesiophobia (TSK-R) both were used 3 times. 2) According to domestic clinical studies, VAS was used 37 times as pain scale, NRS was 11, and Short Form McGill Pain Questionnaire (SF-MPQ) was used 6 times. ODI was used 30 times as function scale, RMDQ was 2 times only. SF-36 was used once as generic health status scale and Beck's Depression Inventory (BDI) was used 3 times as psychological scale. Conclusions We recommend VAS or NRS as a measure to evaluate pain, and ODI as a measure to evaluate functional disability. And we also recommend SF-36 or SF-12 and EQ-5D as a measure to evaluate generic health status. Finally, we recommend FABQ for use in measuring psychological scale.

Identification of Pre-pasteurization or Pre-irradiation Treatment in Frozen Crushed Garlic Commercially Available in Korean Market (시판 유통 중인 냉동 다진 마늘의 사전 살균 및 조사처리 여부 판별 모니터링)

  • Kim, Hyo-Young;Ahn, Jae-Jun;Kim, Gui-Ran;Jeong, Jin-Hwa;Park, Ki-Hwan;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1673-1681
    • /
    • 2013
  • Five different chopped frozen garlic products samples, three from Chinese and two from Korean origins being commercially available products in Korean market, were used to confirm their pre-pasteurization or pre-irradiation status by screening (direct epifluorescent filter technique/aerobic plate counts, DEFT/APC; electronic nose, E-nose; photostimulated luminescence, PSL) and identification (thermoluminescence, TL; electron spin resonance, ESR) techniques. Some parts of samples were gamma-irradiated at 1 kGy to be used as control samples in irradiation history identification. DEFT/APC and e-nose successfully showed distinct results between the domestic and imported samples. The PSL photon counts of all the unknown samples were less than 700 (negative), while most of 1 kGy-irradiated samples gave PSL photon counts more than 5,000 (positive). The domestic unknown samples produced the TL glow peaks after $300^{\circ}C$ or more, whereas the imported samples showed TL peaks at the range of $240{\sim}250^{\circ}C$. A clear TL glow peak was obtained from all irradiated samples at $150{\sim}250^{\circ}C$. The unknown samples of Chinese origin gave radiation-specific cellulose ESR signal that was not shown by domestic samples. A multiple step of applying the physical analytical methods is recommended for the effective identification of irradiation status on chopped frozen garlic products.

Multivariate Analysis of Variation of Growth and Quality Characteristics in Colored Rice Germplasm (유색미 도입 유전자원의 생육 및 품질특성 변이 다변량 분석)

  • Park, Jong-Hyun;Lee, Ji-Yoon;Chun, Jae-Buhm;You, Oh-Jong;Son, Eun-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.63 no.3
    • /
    • pp.175-185
    • /
    • 2018
  • The aim of this study was to evaluate the variation of growth and quality characteristics in colored rice from 178 accessions and to develop useful, basic rice breeding data by classifying these germplasm characteristics via principal component (PC) analysis. The coefficient of variation of the 178colored rice accessions were the highest for panicle length (PL) and protein contents, followed by length-width ratio (LWR), 1000-grain weight (TGW), culm length (CL), and amylose contents, whereas the lowest was for the number of panicles per hill (NP), which is a yield component. The results from the PC analysis exhibited eigenvalues and contributions respective to each PC as follows: PC1, 2.06 and 29.49%; PC2, 1.31 and 18.75%; PC3, 1.21 and 17.36%; PC4, 1.01 and 14.38%. The eigenvalues of four PCs were over 1.0, and their cumulative contributions were 79.98%, which completes the necessary condition for evaluation of the 178 colored rice accessions. Cluster analysis showed cluster I as the largest, which included 79 accessions, while clusters II, III, IV, V, VI, and VII comprised 46, 19, 13, 4, 8, and 9 accessions, respectively. Moreover, dark brown accessions were dispersed in clusters I and II, and many resources of purple seed coat color were found in clusters V, VI, and VII. Particularly, cluster V had resources of only black and purple seed coat colors. Resources of cluster VII were found to have a relatively small average CL, PL, and LWR; notably, cluster V had the smallest average TGW, and cluster IV the lowest NP but the highest TGW. Finally, considering the yield potential, growth characteristics, heading stage, and color during breeding of colored rice, we obtained the following conclusions: cluster VII is suitable for breeding of colored rice; cross breeding among clusters I, II, and VII has a high yield potential; and it is possible to produce a superior color by cross breeding plants from cluster V and VI.

Design Evaluation Model Based on Consumer Values: Three-step Approach from Product Attributes, Perceived Attributes, to Consumer Values (소비자 가치기반 디자인 평가 모형: 제품 속성, 인지 속성, 소비자 가치의 3단계 접근)

  • Kim, Keon-Woo;Park, Do-Hyung
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.4
    • /
    • pp.57-76
    • /
    • 2017
  • Recently, consumer needs are diversifying as information technologies are evolving rapidly. A lot of IT devices such as smart phones and tablet PCs are launching following the trend of information technology. While IT devices focused on the technical advance and improvement a few years ago, the situation is changed now. There is no difference in functional aspects, so companies are trying to differentiate IT devices in terms of appearance design. Consumers also consider design as being a more important factor in the decision-making of smart phones. Smart phones have become a fashion items, revealing consumers' own characteristics and personality. As the design and appearance of the smartphone become important things, it is necessary to examine consumer values from the design and appearance of IT devices. Furthermore, it is crucial to clarify the mechanisms of consumers' design evaluation and develop the design evaluation model based on the mechanism. Since the influence of design gets continuously strong, various and many studies related to design were carried out. These studies can classify three main streams. The first stream focuses on the role of design from the perspective of marketing and communication. The second one is the studies to find out an effective and appealing design from the perspective of industrial design. The last one is to examine the consumer values created by a product design, which means consumers' perception or feeling when they look and feel it. These numerous studies somewhat have dealt with consumer values, but they do not include product attributes, or do not cover the whole process and mechanism from product attributes to consumer values. In this study, we try to develop the holistic design evaluation model based on consumer values based on three-step approach from product attributes, perceived attributes, to consumer values. Product attributes means the real and physical characteristics each smart phone has. They consist of bezel, length, width, thickness, weight and curvature. Perceived attributes are derived from consumers' perception on product attributes. We consider perceived size of device, perceived size of display, perceived thickness, perceived weight, perceived bezel (top - bottom / left - right side), perceived curvature of edge, perceived curvature of back side, gap of each part, perceived gloss and perceived screen ratio. They are factorized into six clusters named as 'Size,' 'Slimness,' 'No-Frame,' 'Roundness,' 'Screen Ratio,' and 'Looseness.' We conducted qualitative research to find out consumer values, which are categorized into two: look and feel values. We identified the values named as 'Silhouette,' 'Neatness,' 'Attractiveness,' 'Polishing,' 'Innovativeness,' 'Professionalism,' 'Intellectualness,' 'Individuality,' and 'Distinctiveness' in terms of look values. Also, we identifies 'Stability,' 'Comfortableness,' 'Grip,' 'Solidity,' 'Non-fragility,' and 'Smoothness' in terms of feel values. They are factorized into five key values: 'Sleek Value,' 'Professional Value,' 'Unique Value,' 'Comfortable Value,' and 'Solid Value.' Finally, we developed the holistic design evaluation model by analyzing each relationship from product attributes, perceived attributes, to consumer values. This study has several theoretical and practical contributions. First, we found consumer values in terms of design evaluation and implicit chain relationship from the objective and physical characteristics to the subjective and mental evaluation. That is, the model explains the mechanism of design evaluation in consumer minds. Second, we suggest a general design evaluation process from product attributes, perceived attributes to consumer values. It is an adaptable methodology not only smart phone but also other IT products. Practically, this model can support the decision-making when companies initiative new product development. It can help product designers focus on their capacities with limited resources. Moreover, if its model combined with machine learning collecting consumers' purchasing data, most preferred values, sales data, etc., it will be able to evolve intelligent design decision support system.

The Structure of Korean Radiation Oncology in 1997 (국내 병원 별 방사선치료의 진료 구조 현황(1997년 현황을 중심으로 한 선진국과의 비교 구))

  • Kim Mi Sook;Yoo Seoung Yul;Cho Chul Koo;Yoo Hyung Jun;Yang Kwang Mo;Je Young Hoon;Lee Dong Hun;Lee Dong Han;Kim Do Jun
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.172-178
    • /
    • 1999
  • Purpose : To measure the basic structural characteristics of radiation oncology facilities in Korea during 1997 and to compare personnel, equipments and patient loads between Korea and developed countries. Methods and Materials : Mail serveys we conducted in 1998 and data on treatment machines, personnel and peformed new patients were collected. Responses were obtained from the 100 percent of facilities. The consensus data of the whole country were summarized using Microsoft Excel program. Results: In Korea during 1997, 42 facilities delivered megavoltage radiation theraphy with 71 treatment machines, 100 radiation oncologists, 26 medical physicist, 205 technologists and 19,773 new patients. Eighty nine percent of facilities in Korea had linear accelators at least 6 MeV maximum photon energy. Ninety five percent of facilities had simulators while five percent of facilities had no simulator, Ninety one percent of facilities had computer planning systems and eighty three percent of facilities reported that they had a written quality assurance program. Thirty six percent of facilities had only one radiation oncologist and thirty eight percent of facilities had no medical physicists. The median of the distribution of annual patients load of a facility, patients load per a machine, patients load per a radiation oncologist, patients load per a therapist and therapists per a machine in Korea were 348 patients per a year, 263 patients per a machine, 171 patients per a radiation oncologist, 81 patients per a therapist, and 3 therapists per a machine respectively. Conclusions : The whole scale of the radiation oncology departments in Korea was smaller than Japan and USA in population ratio regard. In case of hardware level like linear accelerators, simulators and computer planning systems, there was no big differences between Korea and USA. The patients loads of radiation oncologists and therapists had no significant differences as compared with USA. However, it was desirable to consider the part time system in USA because there were a lot of hospitals which did not employ medical physicists.

  • PDF

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF