• 제목/요약/키워드: PCS(Power Conditioning System)

검색결과 195건 처리시간 0.028초

30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석 (Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System)

  • 박재범;김미성;노대석
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.

태양광 발전 PCS 구성부품에 대한 열적특성 및 고장모드영향분석 (Thermal Characteristic and Failure Modes and Effects Analysis for Components of Photovoltaic PCS)

  • 김두현;김성철;김윤복
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.1-7
    • /
    • 2018
  • This paper is analyzed for the thermal characteristics(1 year) of the 6 components(DC breaker, DC filter(including capacitor and discharge resistance), IGBT(Insulated gate bipolar mode transistor), AC filter, AC breaker, etc.) of a photovoltaic power generation-based PCS(Power conditioning system) below 20 kW. Among the modules, the discharge resistance included in the DC filter indicated the highest heat at $125^{\circ}C$, and such heat resulting from the discharge resistance had an influence on the IGBT installed on the rear side the board. Therefore, risk priority through risk priority number(RPN) of FMEA(Failure modes and effects analysis) sheet is conducted for classification into top 10 %. According to thermal characteristics and FMEA, it is necessary to pay attention to not only the in-house defects found in the IGBT, but also the conductive heat caused by the discharge resistance. Since it is possible that animal, dust and others can be accumulated within the PCS, it is possible that the heat resulting from the discharge resistance may cause fire. Accordingly, there are two options that can be used: installing a heat sink while designing the discharge resistance, and designing the discharge resistance in a structure capable of avoiding heat conduction through setting a separation distance between discharge resistance and IGBT. This data can be used as the data for conducting a comparative analysis of abnormal signals in the process of developing a safety device for solar electricity-based photovoltaic power generation systems, as the data for examining the fire accidents caused by each module, and as the field data for setting component management priorities.

국내 태양광발전용 마이크로 인버터 기술기준에 관한 연구 (A Study on the Technical Standard of Micro-Inverter for Domestic Photovoltaic Power Generation)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.175-180
    • /
    • 2019
  • 스트링 인버터의 정격전력이 낮은 단점을 보완하기 위하여 전력변환장치(PCS: Power Conditioning System)를 마이크로 인버터를 사용하여 기존 PCS와 비교하여 마이크로 인버터의 필요성과 향후의 발전 방향을 고찰하고자 한다. 현재 가정용 태양광발전 시스템에서는 스트링 인버터를 사용해 왔으며 유럽을 시작으로 스트링 인버터의 단점을 보완할 수 있는 마이크로 인버터(PV-MIC)의 연구 및 보급률이 확장 되고 있는 실정이다. 그러나 국내 태양광인버터 업계에서는 태양광발전용 마이크로 인버터(PV-MIC)에 대한 정확한 기술기준 및 시험 측정 장비 및 관련 시험방법 부재가 제품 개발에 걸림돌이 되고 있다. 따라서 본 논문에서는 마이크로 인버터(PV-MIC)의 특성을 고려하여 시험측정 장비 및 관련 기술기준 연구를 통해 선진기술 변화에 뒤쳐지지 않도록 경쟁력을 갖출 수 있는데 목적을 둔다.

에너지 저장장치를 갖는 고 전력밀도 및 저가격형 태양광 인버터 시스템 (High Power Density and Low Cost Photovoltaic Power Conditioning System with Energy Storage System)

  • 장두희;지상근;박정필;정남성;노정욱;홍성수;한상규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.399-400
    • /
    • 2010
  • 본 논문에서는 고전력 밀도 및 저가형으로 구현이 가능한 새로운 구조의 계통 연계형 태양광 인버터 시스템을 제안한다. 제안된 시스템은 태양전지의 최대 전력점 추종기능과 배터리의 충 방전 기능을 통합하여 기존 3단 구성을 2단으로 줄임으로써 시스템 제작단가가 낮아지고 고전력 밀도 구성이 가능하다. 제안 시스템의 우수성과 신뢰성 검증을 위하여 1.5kW급 PV PCS 시작품을 제작하고 이를 이용한 실험결과를 바탕으로 제안 시스템의 타당성을 검증한다.

  • PDF

1kW급 계통연계 보조 전원용 PEMFC 시스템 개발 (Development of 1kW class grid-connected PEMFC system)

  • 이호준;함미숙;한세영;이정민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.176-179
    • /
    • 2007
  • 본 연구에서는 고분자연료전지(PEMFC)을 이용하여 보조전원용으로 사용할 수 있는 계통연계 연료전지 시스템을 개발하였다. 또한 본 연구에서는 DSP(Digital Signal Processor)칩을 이용한 계통 연계용 전력변환기(PCS, Power Conditioning System)와 제어시스템 개발도 병행하여 수행되었다. 개발된 1kW급 계통연계형 시스템은 다양한 조건에서의 스택 성능 실험 및 BOP 연계 시험을 통해 최적의 운전점을 도출할 수 있었으며, PID(Proportional, Integral, Differential) 운전제어 방법올 적용하여 시스템의 안정적인 운전 특성을 확보하였다. 향후 본 시스템을 계통연계용은 물론 독립전원용으로 사용하기 위해 전력변환장치를 설계중이며, 2007년 하반기에 시스템에 적용될 예정이다.

  • PDF

연료전지 시스템용 전력변환기(PCS) 회로 및 제어방식에 따른 저주파 리플 분석 (Analysis of the Low Frequency Ripple according to a Power Conditioning System Topology and Control Strategy for the Fuel Cell System Applications)

  • 김종수;강현수;이병국;이원용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.197-198
    • /
    • 2007
  • 본 논문에서는 연료전지 시스템에서 발생되는 저주파 리플의 전달과정을 분석하고, PCS 회로 및 인버터 제어방식에 따른 저주파 리플 영향을 비교 분석한다. 부스트 컨버터와 풀브리지 컨버터의 입력전류 고조파 분포와 인버터 PWM 스위칭 방식에 따른 입력전류에서의 영향을 고조파 분포 및 저주파 리플 측면에서 분석한다. 풀브리지 컨버터에서 전달되는 저주파 리플 크기가 상대적으로 작은 것을 확인하고, PWM 스위칭 방식은 저주파 리플에 영향을 주지 않는다는 것을 시뮬레이션을 통하여 확인한다.

  • PDF

1kW급 보조전원용 연료전지 시스템 개발 (Development of 1kW Class Fuel Cell System for Auxiliary Power)

  • 한세영;최동민;신범수;심재휘;이호준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.189-191
    • /
    • 2007
  • 본 연구에서는 고분자전해질연료전지(PEFC)를 이용하여 보조전 원용으로 사용할 수 있는 계통연계 연료전지 시스템을 개발하였다. 또한 본 연구에서 DSP(Digital Signal Processor)를 이용한 계통연계형 전력변환장치(PCS, Power Conditioning System)와 시스템 제어기의 개발도 병행하여 수행되었다. 개발된 1kW급 보조전원용 연료전지 시스템은 다양한 조건에서의 스택 성능 실험 및 BOP 연계 시험을 통해 최적의 운전점을 도출할 수 있었으며, PID(Proportional, Integral, Differential) 운전제어 방식을 통하여 시스템의 안정적인 운전 특성을 확보하였다. 향후 본 시스템은 계통연계용은 물론 독립전원용으로도 사용이 가능할 수 있도록 전력변환장치를 설계하여 적용할 예정이다.

  • PDF

에너지 저장장치를 갖는 고 전력밀도 및 저가격형 태양광 인버터 시스템 (High Power Density and Low Cost Photovoltaic Power Conditioning System with Energy Storage System)

  • 금문환;장두희;홍성수;한상규;사공석진
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.587-593
    • /
    • 2011
  • 본 논문에서는 고 전력밀도 및 저가형으로 구성 가능한 새로운 구조의 계통 연계형 태양광 인버터 시스템을 제안한다. 제안 시스템은 태양전지의 최대 전력점 추종기능과 배터리의 충 방전 기능을 단일 전력단으로 구성함으로써, 고 전력밀도 및 저가격형 시스템 구성이 가능하다. 또한, 제안 시스템은 배터리를 링크 캐패시터에 직렬 연결함으로써 링크 캐패시터의 전압 스트레스를 배터리 전압만큼 저감할 수 있으므로 가격저감 효과가 크다. 최종적으로 제안 시스템의 우수성과 신뢰성 검증을 위하여 1.5kW급 태양광 인버터 시스템의 시작품을 제작하였고, 이를 이용한 실험결과를 바탕으로 제안 시스템의 타당성을 검증한다.

풀브리지 컨버터를 갖는 1[kW] 연료전지 시스템 스위치 병렬 특성 분석 (Switch Paralleling Characteristic Analysis for FB Converter in 1[kW] Fuel-Cell System)

  • 최중묵;한동화;이영진;정병환;최규하
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.62-70
    • /
    • 2010
  • Fuel cell system which can solve the environmental problem is receiving attention. To use utility power necessary power conversion system from low voltage that is generated by fuel cell system. because fuel cell has special characteristic of low voltage high current. To improve PCS's efficiency the paralleling method is used. Available the method could reduce the switching loss. But the existing research could not be found optimal result and accompanying several effects. In this study analysis several effects causing the parallel method. The effects have been demonstrated through simulations and experiments.