• Title/Summary/Keyword: PA position

Search Result 107, Processing Time 0.023 seconds

A Study on Mechanical Properties Evaluation of Fiber-reinforced Plastic Cellular Injection-molded Specimens for the Development of High-strength Lightweight MHEV Battery Housing Molding Technology (고강성 경량 MHEV 배터리 하우징 성형기술개발을 위한 섬유강화 플라스틱 발포 사출 시험편의 기계적 물성평가에 관한 연구)

  • Eui-Chul Jeong;Yong-Dae Kim;Jeong-Won Lee;Sung-Hee Lee
    • Design & Manufacturing
    • /
    • v.17 no.3
    • /
    • pp.55-60
    • /
    • 2023
  • The fiber-reinforced plastics and cellular injection molding process can be used to efficiently reduce the weight of battery housing components of mild hybrid electronic vehicles(MHEV) made of metal. However, the fiber orientation of fiber-reinforced plastics and the growth of foaming cells are intertwined during the injection molding process, so it is difficult to predict the mechanical properties of products in the design process. Therefore, it is necessary to evaluate the mechanical properties of the materials prior to the efficient stiffness design of the target product. In this study, a study was conducted to evaluated the mechanical properties of fiber reinforced cellular injection-molded specimens. Two types of fiber-reinforced plastics that can be used in the target product were evaluated for changes in tensile properties of cellular injection-molded specimens depending on the foaming ratio and position from the injection gate. The PP and PA66 specimens showed a decrease of tensile modulus and strength of approximately 30% and 17% depending on the foaming ratio, respectively. Also, the tensile strength decreased approximately 26% and 17% depending on the position from the injection gate, respectively. As a result, it was confirmed that the PP specimens have a significantly mechanical property degradation compared to the PA66 specimens depending on the foaming ratio and position.

Development of Two Types of Novel Planar Translational Parallel Manipulators by Using Parallelogram Mechanism (평행사변형 기구를 이용한 평면 병렬형 병진운동 기구 개발)

  • Kim, Han-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.50-57
    • /
    • 2007
  • In this paper, two types of novel planar Translational Parallel Manipulators (TPMs) by using parallelogram mechanism are conceived. One is made up of two Pa-P (Parallelogram-Prismatic) legs connecting the base to the moving platform. The other consists of two P-Pa legs, which is the kinematic inversion of the former. Since connecting links in a parallelogram mechanism are subject to only tensile/compressive load and all the heavy actuators are mounted at the base, the proposed manipulators can be applied for planar positioning/assembly tasks requiring high stiffness and high speed. The position, velocity, and statics are analyzed, and the design methodology using prescribed workspace and velocity transmission capability is presented. Finally, two types of prototype manipulators have been developed.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

The change of frontal ramal inclination (FRI) after orthognathic surgery with laterognathism: posteroanterior cephalometric study (Laterognathism의 술후 전방하악골상행지경사도 변화에 관한 정모두부방사선학적 연구)

  • Yu, Sang-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.21-29
    • /
    • 2011
  • Introduction: To compare the change in frontal ramal inclination (FRI) in laterognathism after orthognathic surgery. Materials and Methods: Twenty four patients (10 men, 14 women; mean age, $22.8{\pm}5.2$ years) with minimal facial canting (${\leq}$ 2 mm) and apparent menton deviation ($5.9{\pm}2.4\;mm$) who had been operated on to correct facial asymmetry and skeletal CIII malocclusion, were selected. On a preoperative posteroanterior (PA) cephalogram, the FRI of the deviated side and non deviated side, L1 deviation amounts and menton deviation amounts were measured. The FRI differences between both sides were compared, and the correlations between the measured deviated elements and the FRI differences were analyzed. On a postoperative PA cephalogram, the shifting amount of L1, shifting amount of L7 and FRI of both sides were measured, and the correlations between the shifting elements and the change in FRI were analyzed. Results: On the preoperative PA cephalogram, the FRI of the non deviated side was significantly greater than those of the deviated side. The differences in FRI, with a menton deviation amount showed a significant correlation. On the postoperative PA cephalogram, the FRI differences between the deviated and non deviated side were decreased significantly and mandibular transverse movement toward central position was noted. The mean shifting amounts of L7 were associated with the amount of change in the deviated side of FRI. Conclusion: Transverse shifting of the mandible through orthognathic surgery decreases the FRI difference, which showed laterognathism, and improves the facial contour.

A Numerical Study on the Influence of the Shaft Geometry on the Stack Effect (수직통로의 형상이 연돌효과에 미치는 영향에 관한 수치해석 연구)

  • Jeon, Heung-Kyun;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.74-81
    • /
    • 2011
  • The numerical analyses for three different shafts in geometry of high buildings were carried out by using computational fluid dynamics model (FDS ver.5.3) for the calculation of the pressure difference and the location of the neutral plane and the visualization of stack effect. At 10 seconds of stack effect, the pressure difference of stack effect in the elevator shaft (79.3 Pa) almost corresponded to the theoretical value (78 Pa). At 300 seconds of stack effect, all the neutral planes of three cases were located about 49 m above floor, where was 5 m higher than the theoretical value. The maximum pressure difference between upper and lower position of shaft decreased with increasing of the geometrical complexity of shaft. This study showed that there was the difference of the stack effects among the geometries of shafts with the visualization of stack effect.

Bias Correction for Aircraft Temperature Observation Part I: Analysis of Temperature Bias Characteristics by Comparison with Sonde Observation (항공기 온도 관측 자료의 편향 보정 Part I: 존데와 비교를 통한 온도 편향 특성 분석)

  • Kwon, Hui-nae;Kang, Jeon-ho;Kwon, In-Hyuk
    • Atmosphere
    • /
    • v.28 no.4
    • /
    • pp.357-367
    • /
    • 2018
  • In this study, the temperature bias of aircraft observation was estimated through comparison with sonde observation prior to developing the temperature bias correction method at the Korea Institute of Atmospheric Prediction Systems (KIAPS). First, we tried to compare aircraft temperature with collocated sonde observations at 0000 UTC on June 22, 2012. However, it was difficult to estimate the temperature bias due to the lack of samples and the uncertainty of the sonde position at high altitudes. Second, we attempted a background innovation comparison for sonde and aircraft using KIAPS Package for Observation Processing (KPOP). The one month averaged background innovation shows the aircraft temperature have a warm bias against sonde for all levels. In particular, there is a globally distinct warm bias about 0.4 K between 200 hPa and 300 hPa corresponding to flight level. Spatially, most of the areas showed the warm bias except for below 300 hPa in some part of China at 0000 and 1200 UTC and below 850 hPa in Australia at 0000 UTC. In general, the temperature bias was larger at 1200 UTC than 0000 UTC. Based on the estimated temperature bias, we have applied the static bias correction method to the aircraft temperature observation. As a result, the warm bias of the aircraft temperature has decreased at most levels, but a slight cold bias has occurred in some areas.

Effects of Breast Dose on Plain Abdominal Position (복부 방사선검사 자세가 유방선량에 미치는 영향)

  • Joo, Young-Cheol;Kim, Sheung-Hyuk
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.155-159
    • /
    • 2020
  • The purpose of this study is to investigate the effect of posture changes(Anteroposterior projection, Posteroanterior projection) in the plain abdominal examination on breast dose and to examine its clinical usefulness. This study was used a human body phantom and a glass dosimeter. Glass dosimeters were directly inserted from the center and outside of medial and lateral. In this study, the deep dose was measured in the right breast and the surface dose in the left breast. During the abdominal examination, the central X-ray incident point was perpendicularly incident to the image receptor 5 cm above the iliac crest. The exposure parameters were 82 kVp, 320 mA, 50 ms, x-ray field size 14×17 inch The distance between the center X-ray and the detector was fixed at 110 cm, and only the top two AEC chambers were used. As a result of this study, the medial and lateral side doses of the right breast were 535.73±30.68 μGy and 414.46±33.52 μGy for erect AP, and 145.80±18.52 μGy and 148.76±12.92 μGy in erect PA. The superficial breast dose was 754.00±68.36 μGy on the medial side and 674.06±45.58 μGy on the lateral side in the erect AP, 70.66±7.98 μGy on the medial side, and 86.46±15.35 μGy on the lateral side in the erect PA. There was a statistically significant difference in the difference between the mean values of the medial and lateral side doses in the deep and superficial areas of the breast according to the postural change (p <0.01). As a result of this study, If the abdominal radiography was examined in the PA position, the dose reduction effect was 72.78% on the medial side, 64.10% on the lateral side of the deep breast, 90.62% on the medial side, and 87.17% on the lateral side of the superficial breast compared to the AP position.

Dose Reduction of the Adolescent Female Breast during Scoliosis Radiography (청소년기 여성의 척추측만증 검사에서 유방입사선량 저감효과)

  • Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.373-379
    • /
    • 2018
  • The purpose of this study was to investigate quantitative data on the difference in breast entrance surface dose with changes in focus-film distance, patient posture (anteroposterior-posteroanterior), thoracic wall thickness, rib bone thickness, lung tissue thickness, tube voltage, and high-voltage rectification method in Whole Spine Scanography, which is necessary for the treatment of scoliosis patients. Given a tube voltage of 90 kVp, kerma of 0.1 mGy, focus-film distance of 260 cm, tube voltage ripple rate of 0, filter thickness of 3.5 mm, and thickness of patient's thoracic wall of 120 mm as an X-ray exposure condition, from the simulation results using the Simulation of X-ray Spectra program to confirm the reduction effect of breast entrance surface dose according to the patient's posture (AP and PA), there was a dose reduction effect in aluminum filter thickness of 2.6 times at 3.5 mm, 25.7 times the thoracic wall thickness at 120 mm, 1.43 times higher tube voltage, and 0 to 1.14 times the tube voltage ripple rate. The total dose reduction effect was about 109 times. In order to confirm the dose reduction effect of RANDO phantom posture (AP and PA), from the results of the measurements taken under the conditions that the focus-film distance was 260 cm, the tube voltage was 90 kVp, the tube current was 270 mA, the exposure time was 0.31 sec, and the tube voltage ripple rate of X-ray generators was 0, the entrance surface dose reduction effect of the breast in the PA position was found to be 20.56 times lower than that of the AP position.

Numerical Analysis on Tilting Control of Suction Pile for Offshore Wind Power (해상풍력 석션파일의 수직도 제어에 대한 수치해석)

  • Kim, Byeongwan;Kim, Youseok;Jin, Byeongmoo;Bae, Kyung-tae;Youn, Heejung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.9
    • /
    • pp.5-12
    • /
    • 2016
  • Numerical analyses were carried out to simulate tilting control on the suction pile for offshore wind power embedded into cohesive soil and cohesionless soil using finite element software, ABAQUS. A 3-dimensional suction pile was modelled as a wished-in-place pile with $1^{\circ}$ tilted from vertical line. The inner room of suction pile was divided into 3 separate rooms for tilting control, and point load was applied to the center of gravity of a separate room to restore the original position of the suction pile. From numerical analyses, required suction pressure was obtained for desired tilting degree, and the maximum/minimum principle stresses of concrete skirt and the Mises stresses of inner steel wall were collected at original position. It was found that the required suction pressure was about 410 kPa for cohesive soil, and about 1,800 kPa for cohesionless soil.; likewise, obtained stresses were greater for cohesionless soil than cohesive soil.

Observational Characteristics of East Asian Monsoon during the Summers of 1993 and 1994 (1993, 1994년 여름철 동아시아몬순의 관측 특성)

  • Kim, Baek-Jo;Ryu, Chan-Su
    • Journal of the Korean earth science society
    • /
    • v.23 no.4
    • /
    • pp.369-379
    • /
    • 2002
  • The characteristics of the East Asian summer monsoon circulation associated with the cool and wet summer of 1993 and the warm and dry summer of 1994 are investigated by analyzing the atmospheric circulations features in the upper and lower troposphere and by examining the global SST and associated tropical convective precipitation fields. The negative geopotential height anomalies at 500 hPa and 200 hPa in 1993 over East Asia, the central North Pacific, and the western United States were replaced by positive ones in 1994. In addition, the 200 hPa zonal wind anomaly averaged over the East Asian summer monsoon region is negatively correlated with the Korean summer temperature anomaly. The subtropical jet stream in 1993 was displaced into the central part of Korea well south of its normal position. The western Pacific subtropical high was shifted southward, and the East Asian summer rainfall and temperature was above-normal and below-normal, respectively due to the southwestward extension of a cold and dry polar airmass from the Sea of Okhotsk to the Est Sea. In contrast, the subtropical jet stream in 1994 was displaced well north of its normal position. The abrupt northward shift of the western Pacific subtropical high was accompanied with the rapid northward movement of the rain band of the East Asian summer monsoon rainfall. The anomaly patterns of the East Asia summer rainfall and temperature were opposite to those of 1993. Large sea surface temperature anomalies of opposite signs existed in the tropical Pacific with a mature El $Ni{\~{n}o$ in 1993 and a weak La $Ni{\~{n}a$ condition in 1994. The role of the anomalous convective precipitation in the western Pacific and the Indian Ocean related with the variations in the low-level cross-equatorial flow along the northwestern periphery of the Australian high and the Mascarene high is probably to influence a large-scale atmospheric circulation over the East Asia during both the years.