• Title/Summary/Keyword: P.B.T.

Search Result 3,566, Processing Time 0.041 seconds

An Extracellular Polysaccharide Produced by Methylovorus sp. Strain SS1 Growing on Methanol (메탄올을 이용하여 성장하는 Methylovorus sp. strain SS1이 생산하는 세포외 다당류)

  • 추원호;송택선;김영민
    • Korean Journal of Microbiology
    • /
    • v.33 no.2
    • /
    • pp.142-148
    • /
    • 1997
  • Mrthylov~orits sp. starin SSl, a restricted facultative methylotrophic bacterium. growing on methanol was found to produce small amount of extracellular polysaccharide (EPS) under the optimal growth conditions, while it produced large amount of the polysaccharide under nitrogen limihtion. The optimal ratio of carbon to nitrogen for EPS production were found to be 5.2. The optimal temperature and pH for EPS production were 30^{\circ}C.$ and 6.5, spectively. The EPS consisted of carbohydrate, protein and small amount pyruvic acid. The reducing sugars in the EPS consisted mainly of glucose and a small amount of mannose. The EP!; treated with ethanol (EPSae) was found to have several properties different from those of the EPS which was not treated with ethanol (EPSbe); the EPSae contained no pyruvic acid. It also contained less protein and showed much lower viscosity than the EPSbe. The viscosity of EPSbe was very sensitive to NaCl and decreased t;harply upon exposure of the polysaccharide to even 0.5% (wiv) NaCl solution. The viscosity, however, was increased irreversibly upon exposure of the saccharide to high temperature. The molecular weight of EPS was estimiited to be $2.5{\times}$10^6$ - $3.5{\times}*$10^6$ using Sepharose hB column chromatography. Scanning electron microscopy revealed that the lyophilized EPSbe and EPSae have a structure of thread-like fibers and a mesh-like structure resembling bee-hive, respectively.

  • PDF

A Study on Hospitalized Patients' Intent to Use Home Care Nursing According to the Types of Medical Security (입원환자의 의료보장형태에 따른 가정간호 이용의사에 대한 연구)

  • Kim, Myung-Hee;Cho, Eun-Ji;Park, Hyoung-Sook;Kang, In-Soon
    • Journal of Home Health Care Nursing
    • /
    • v.12 no.2
    • /
    • pp.63-86
    • /
    • 2005
  • Purpose: This study is a descriptive research which is designed to investigate hospitalized patients' intent to use home care nursing according to the types of medical security. Method: This researcher surveyed 236 patients who were hospitalized at B medical center located in Busan,. Data were collected from Sep. 1 to Nov. 30, 2005 using a questionnaire survey, medical records, face-to-face interviews and observations. Collected data were analyzed in terms of frequency, percentage, mean and standard deviation through $x^2$-test and t-test under SPSS WIN 10.0 Program. Result: Out of the total subjects, 59.3% were medical aid clients and the remaining 40.7%, health insurance ones. The hospitalized period and frequency of the former group were 38.0 days and 4.0 times, respectively, while those of the latter, 37.7 and 3.4. When home care nursing clients were examined using a given classification device, it was found that out of the total 236 subjects, 205(86.9%) were needed to receive home care nursing, 121, medical aid and the other 84, health insurance. 24.0% of medical aid clients heard about home care nursing ever before, lower than 39.3% of health insurance clients. 43.8% of the former clients said cost for home care nursing was high while, 47.6% of the latter group responded expense for the nursing intervention was low. 30.6% of medical aid clients had intent to use home care nursing, lower than 47.6% of health insurance clients. 71.7% of those patients whose monthly income was 99 million won or below had no intent to use home care nursing, higher than 62.5% of those who were 100 million or over in monthly income(p<.05). 76.4% of those clients who had no nursing provider intented to use home care nursing, higher than those who had nursing provider(p<.05). Concerning contents of home care nursing, 85.1% of medical aid clients needed education, training and counseling while, 77.4% of health insurance aids wanted medication and injection. Conclusion: In conclusion, the use of home care nursing by medical aid clients should be promoted through improving conditions for home care nursing in terms of expense, family and residence and making public relations about activities and contents of the home care nursing.

  • PDF

Effect of Coptidis Rhizoma extract on Atopic Dermatitis-like Skin Lesions in NC/Nga Mice (황련 추출물의 아토피피부염 유발 생쥐에서 피부손상 완화 효과)

  • Jung, A Ram;Ahn, Sang Hyun;Jeong, Han Sol;Kim, Ki Bong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.33 no.2
    • /
    • pp.102-108
    • /
    • 2019
  • This study aims to evaluate the anti-inflammatory effect of Coptidis Rhizoma (CR) extract for atopic dermatitis through maintaining skin barrier and regulating Th2 cell differentiation. We divided NC/Nga mice into 3 groups as follows; atopy-like dermatitis induced group with CR treatment (CT, n=10), no treatment group(Ctrl), atopy-like dermatitis elicited group(AE). Atopy-like dermatitis was induced to NC/Nga mice by sensitizing with dermatophagoides farinae(DfE) on 7, 8, 9, 11, 12, and 13th week. After inducing atopic dermatitis, CR extract was administered 20 mg/kg daily for the experimental duration to the CT group. We measured the integrity of lipid layers in the epidermis and Th2 differentiation through immunohistochemical staining against filaggrin, loricrin, IL-4, and IL-13. We also measured the distribution of subcutaneous collagen fibers by the Masson's trichrome staining. Administration of CR significantly inhibited the reduction of lipid layers in the skin that caused atopy. The expression of IL-4, IL-13, each of which is a cytokine secreted by T helper type 2 (Th2) cells, was markedly suppressed in the CT group as compared with AE group (p<0.05). CR treatment also decreased the expression of iNOS, $p-I{\kappa}B$. Atopic dermatitis induced dermatological damage to skin, such as hyperplasia of epithelium, and capillary proliferation was significantly reduced by CR administration. CR effectively inhibited the thinning of the skin barrier and inflammatory responses in atopic dermatitis-induced mice. In particular, it showed anti-inflammatory effects by reducing the expression of IL-4 and IL-13, Th2 cell cytokines, which play a crucial role in development of atopic dermatitis. Therefore, CR can be a good candidate to ameliorate and treat atopic dermatitis.

Consumption Pattern and Sensory Evaluation of Traditional Doenjang and Commercial Doenjang (재래식 된장과 시판된장의 관능적 특성 및 소비실태)

  • Ahn, Sun-Choung;Bog, Hye-Ja
    • Journal of the Korean Society of Food Culture
    • /
    • v.22 no.5
    • /
    • pp.633-644
    • /
    • 2007
  • The study results regarding the ingredient differences, sensory characteristics, purchasing type, usage and improvement direction for home-made traditional doenjang and factory produced commercial doenjang are as follows. The L-value indicates that home-made traditional doenjang has a higher value in average than the factory produce done, and the a-value indicates the opposite. Home-made traditional doenjang had higher water content than commercial doenjang ; however the pH values of commercial doenjang and home-made were 5.34 and 5.32 respectively, which was very similar. Factory produced commercial doenjang showed higher protein content than the home-made traditional doenjang. Regarding the correlation between ingredients, there was a significantly negative relationship between the L-value and a-value but a significantly positive relationship between the L-value and b-value. There were no significant relationship with water content, pH and protein content. For the color and taste, which are the sensory characteristics, commercial doenjang showed higher value than the traditional doenjang, but for smell, the values were similar. Regarding grittiness, the factory produced commercial doenjang had bigger particles than the traditional doenjang. Preference was a bit higher in the traditional doenjang. Of the 380 study subjects, most were from 40 to 49 years old (65.5%), and the most family type were nuclear families which was a total of 400 people (69%). Moreover, the most residential type was apartment which was 355people (61.2%), and for the monthly income, more than 2,510,000won was 48.3%. For the educational background, college education was 304 people (52.4%), and high school education was 199 people, 34.3%. In the usage, most of the people eat doenjang more than once a week, and usually their parents make the doenjang. People used both commercial doenjang and home-made traditional doenjang >home-made only >factory produced commercial doenjang only in that order. The reasons for using the home-made traditional doenjang aredelicate taste and flavor>more nutritious> anti-cancer ingredients in that order. The reason they use the factory produced commercial doenjang is because they don't know how to make it at home. The things that needed to be improved in the home-made traditional doenjang are bad smell> entire quality> flavor> color in order, indicating that studies for reducing bad smell are required. The things that needed to be improved in the factory produced commercial doenjang are taste & flavor> entire quality>bad smell> color in that order, indicating that people are more concern about it tasting like home-made than the smell. From the above results, we can see that better functional doenjang should be developed for family health and to increase the consumption of the doenjang, which has good functional psychological activities, also more various types of foods that use doenjang and scientific studies to reduce the home-made doenjang smell should be continuously studied. Moreover, studies on how to make the factory produced commercial doenjang taste more like traditional doenjang should be performed.

Detection of Contralateral Breast Cancer Using Diffusion-Weighted Magnetic Resonance Imaging in Women with Newly Diagnosed Breast Cancer: Comparison with Combined Mammography and Whole-Breast Ultrasound

  • Su Min Ha;Jung Min Chang;Su Hyun Lee;Eun Sil Kim;Soo-Yeon Kim;Yeon Soo Kim;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.867-879
    • /
    • 2021
  • Objective: To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. Materials and Methods: Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. Results: Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). Conclusion: In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Correlations between the Capacity of In Vitro Fertilization and the Assays of Sperm Function and Characteristics in Frozen-thawed Bovine Spermatozoa (소 동결-융해 정자에 있어서 체외수정능력과 정자 기능 및 성상 분석법간의 상관관계)

  • Ryu, B.Y.;Chung, Y.C.;Kim, C.K.;Shin, H.A.;Han, J.H.;Kim, S.H.;Moon, S.Y.;Kim, H.R.;Choi, H.
    • Korean Journal of Animal Reproduction
    • /
    • v.26 no.3
    • /
    • pp.275-289
    • /
    • 2002
  • The objective of this study was to develop an in vitro assessment of sperm fertilizing capacity of bulls and investigate the factors influencing sperm function and characteristics of frozen-thawed bovine spermatozoa. in vitro fertilization (IVF), the evaluation of motility and normal morphology, HOST (hypoosmotic swelling test), Ca-ionophore induced acrosome reaction, luminol and lucigenin-dependent chemiluminescence for the measurement of reactive oxygen species (ROS), the measurement of malondialdehyde formation for the analysis of lipid peroxidation (LPO), and the evaluation of DNA fragmentation using the method of 747-mediated nick end labelling (TUNEL) by flow cytometry were performed in frozen-thawed bovine spermatozoa. Correlations between the rates of fertilization, blastocyst formation after IVF and the values of respective assays were investigated. 1. IVF rate and blastocyst formation rate averaged 64.4% and 34.3% for spermatozoa from high -fertility bull group and averaged 18.5% and 6.2% for spermatozoa from low-fertility bull group, respectively. There were significantly different between two bull groups. Sperm motility and percentage acrosome reaction averaged 79.0% and 66.2% for spermatozoa from high-fertility bull group and averaged 40.7% and 22.9% for spermatozoa from low-fertility bull group, respectivitely. There were not different between two bull groups. 2. Luminol depenent chemiluminescence, LPO and DNA fragementation averaged 6.4, 2.0 nmol and 2.6% from spermatozoa from high-fertility bull group and averaged 6.5, 3.1 nmol and 7.4% for spermatozoa from low-fertility bull group, respectively. There were significantly different between two bull groups. There was no significant difference in lucigenin dependent chemiluminescence between two bull groups. 3. Fertilization rate was positively correlated with motility and the rate of Ca-ionophore induced acrosome reaction, but negatively correlated with the frequency of luminol-dependent chemiluminescence, the rate of LPO, and the percentage of sperm with DNA fragmentation. There was no correlation between fertilization rate and the percentage of swollen spermatozoa, normal morphology, and the frequency of lucigenin-dependent chemiluminescence. 4. Blastocyst formation rate was positively correlated with the rate of Ca-ionophore induced acrosome reaction, but negatively correlated with the frequency of luminol-dependent chemiluminescence, the rate of LPO, and the percentage of sperm with DNA fragmentation. There was no correlation between blastocyst formation rate and motility, the percentage of swollen spermatozoa, normal morphology, and the frequency of lucigenin-dependent chemiluminescence. In conclusion, these data suggest that ROS significantly impact semen quality. The assays of this study may provide a basis fur improving in vitro assessment of sperm fertilizing capacity.

Effects of Ferrous Sulfate and Ascorbic Acid on In Vitro Fertility and Sperm Lipid Peroxidation in the Pig (돼지의 체외수정능력과 정자의 Lipid Peroxidation에 있어서 Ascorbic Acid와 Ferrous Sulfate의 영향)

  • Park, C. K.;J. Y. Ann;Kim, I. C.;Lee, J. H.;B. K. Yang;Kim, C. I.;H. T. Cheong
    • Korean Journal of Animal Reproduction
    • /
    • v.25 no.4
    • /
    • pp.317-325
    • /
    • 2001
  • This study investigated the effect of ferrous sulfate (Fe$^{2+}$) and/or ascorbic acid (Asc) on fertilizing ability in vitro of frozen-thawed boar spermatozoa. Using chlortetracycline (CTC) fluorescence, the spermatozoa was treated in preincubation medium with control, Fe$^{2+}$(1 mM), Asc (0.5 mM) and Fe$^{2+}$Asc to assessed for acrosome reaction, and the oocyte penetration test to determine whether the Fe$^{2+}$ and/or Asc can promote the penetration ability in vitro. When frozen-thawed spermatozoa was washed with preincubation medium, there were significantly (P < 0.05) more acrosome-reacted in medium with Fe$^{2+}$Asc (38%) than control (27%). The penetration rates were also significantly (P < 0.05) higher in medium with Fe$^{2+}$Asc (76%) than control (55%). Next, the lipid peroxidation of sperm was evaluated on the basis of malondialdehyde production following same treatments. The addition of Fe$^{2+}$Asc to sperm suspension increases the formation of malondialdehyde. However, there were not significantly different under the all conditions. The sperm suspension were also treated with control, Fe$^{2+}$, Asc and Fe$^{2+}$/Asc and assayed for sulfhydry1(-SH) group content. In the Fe$^{2+}$/Asc group, sperm-SH group were higher than another groups. In spermatozoa treated with Fe$^{2+}$ and/or Asc, however, no changes in sperm -SH-groups were detected when compared to controls. In another experiment, the activity of sperm binding to zona pellucida was evaluated through binding to salt-stored porcine oocytes. In control and Asc treatment groups, sperm binding to zona pellucida were significantly (P < 0.05) higher than in medium with Fe$^{2+}$. On the other hand, there is not a significant increase in binding to zona pellucida with spermatozoa treated by Fe$^{2+}$/Asc. In summary, the present study suggests that Fe$^{2+}$/Asc causes an enhancement in fertilizing ability that is associated with penetration rate increased without change of spermatozoa binding capacity to homologous zona pellucida.o homologous zona pellucida.

  • PDF

Effect of the Combination of Co-Culture System and Supplemented Protein Sources on the In Vitro Development of Bovine IVF Embryos (각종 공동배양 배지와 첨가 단백질원의 조합이 소 체외수정란의 체외배양에 미치는 영향)

  • Cheong, H.T.;Lee, J.H.;Park, C.K.;Yang, B.K.;Kim, C.I.
    • Korean Journal of Animal Reproduction
    • /
    • v.23 no.4
    • /
    • pp.337-345
    • /
    • 1999
  • The present study was conducted to investigate the effects of various co-culture systems and supplemented protein sources on the in vitro development of bovine IVF embryos. Bovine cumulus oocyte complexes (COCs) were matured and fertilized in vitro. Presumptive zygotes with cumulus cells were transferred to TCM-199 or CRlaa containing 10% FBS or 3mg/$m\ell$ BSA, and cultured for 36~40 hr. After primary culture, cleaved embryos were co-cultured with cumulus cells(CC), bovine oviduct epithelial cells(BOEC) or Buffalo rat liver cells (BRLC) in TCM-199 or CRlaa supplemented with FBS or BSA respectively, for further 6 days. Cleavage rate increased with BSA(P<0.01) in the both TCM-199(79%) or CRlaa(74%) When embryos were co-cultured with CC or BOEC in TCM-199, blastocyst development was enhanced with BSA(40% and 43%) compared to FBS (22% and 29%) , whereas in CRlaa no difference observed between BSA(40% and 39%) and FBS (40% and 42%). When embryos were co-cultured with BRLC monolayer, FBS enhanced the blastocyst development (P<0.05) compared to BSA in both TCM-199(41% vs 31%) and CRlaa (44% vs 37%). The result of the present study showed that the cleavage rate of bovine IVF embryos increased with BSA, The result also showed that BSA can enhance the development of IVF embryos in co-culture with CC or BOEC in TCM-199, suggesting the in vitro development is affected by the medium and supplemented protein sources in co-culture with somatic cells.

  • PDF

Satisfaction Evaluation of Diabetic Foot Disease Measurement using AI-based Application (AI기반 에플리케이션을 활용한 당뇨병성 족부질환 측정의 만족도 평가)

  • Hyeun-Woo Choi;Hyo-jin Lee;Min-jeong Kim;Jong-Min Lee;Dong-hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.327-334
    • /
    • 2024
  • The purpose of this study is to develop a customized foot disease analysis and management system for diabetic patients to prevent foot ulcers in diabetic foot disease patients. This system utilizes image analysis technology to measure not only foot pressure, but also ankle deformation, body balance, and foot wounds. Through various data, it is possible to accurately analyze the state of foot deformation, and based on this, the exact state of deformation of the foot of a patient with diabetic foot disease was identified and a customized insole was produced. This study was conducted to examine the satisfaction level of using an application that checks the status of diabetic foot disease wounds and to identify the degenerative status of diabetic foot disease patients and foot disease patients by wearing customized insoles and to survey the satisfaction of wearing insoles. As a result of the study, the knee angle measured for plantar pressure was -0.8 ± 1.3 degrees and ranged from a minimum of -2.4 degrees to a maximum of 1.1 degrees, and there was no significant difference in valgus knee between both lower extremities (p = 0.534). There was a significant difference in tibial angle between both lower extremities (p < 0.001). Ankle angle on the left side was 2.6 ± 2.0 degrees, ranging from a minimum of 0 degrees to a maximum of 6.3 degrees, and on the right, it was 4.5 ± 2.1 degrees, with a distribution of minimum 1.5 degrees to a maximum of 9.1 degrees. There was a significant difference in ankle angle between both lower extremities (p = 0.011). They responded that they felt an average of 4.3 points of satisfaction with the plantar pressure measurement application. Respondents responded that they felt an average of 3.9 points of satisfaction with the use of customized insoles.