• Title/Summary/Keyword: P-wave detection

Search Result 124, Processing Time 0.027 seconds

Attenuated total reflection Fourier transform infrared as a primary screening method for cancer in canine serum

  • Macotpet, Arayaporn;Pattarapanwichien, Ekkachai;Chio-Srichan, Sirinart;Daduang, Jureerut;Boonsiri, Patcharee
    • Journal of Veterinary Science
    • /
    • v.21 no.1
    • /
    • pp.16.1-16.10
    • /
    • 2020
  • Cancer is a major cause of death in dogs worldwide, and the incidence of cancer in dogs is increasing. The attenuated total reflection Fourier transform infrared spectroscopic (ATR-FTIR) technique is a powerful tool for the diagnosis of several diseases. This method enables samples to be examined directly without pre-preparation. In this study, we evaluated the diagnostic value of ATR-FTIR for the detection of cancer in dogs. Cancer-bearing dogs (n = 30) diagnosed by pathologists and clinically healthy dogs (n = 40) were enrolled in this study. Peripheral blood was collected for clinicopathological diagnosis. ATR-FTIR spectra were acquired, and principal component analysis was performed on the full wave number spectra (4,000-650 cm-1). The leave-one-out cross validation technique and partial least squares regression analysis were used to predict normal and cancer spectra. Red blood cell counts, hemoglobin levels and white blood cell counts were significantly lower in cancer-bearing dogs than in clinically healthy dogs (p < 0.01, p < 0.01 and p = 0.03, respectively). ATR-FTIR spectra showed significant differences between the clinically healthy and cancer-bearing groups. This finding demonstrates that ATR-FTIR can be applied as a screening technique to distinguish between cancer-bearing dogs and healthy dogs.

Atrial Fibrillation Pattern Analysis based on Symbolization and Information Entropy (부호화와 정보 엔트로피에 기반한 심방세동 (Atrial Fibrillation: AF) 패턴 분석)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.1047-1054
    • /
    • 2012
  • Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice, and its risk increases with age. Conventionally, the way of detecting AF was the time·frequency domain analysis of RR variability. However, the detection of ECG signal is difficult because of the low amplitude of the P wave and the corruption by the noise. Also, the time·frequency domain analysis of RR variability has disadvantage to get the details of irregular RR interval rhythm. In this study, we describe an atrial fibrillation pattern analysis based on symbolization and information entropy. We transformed RR interval data into symbolic sequence through differential partition, analyzed RR interval pattern, quantified the complexity through Shannon entropy and detected atrial fibrillation. The detection algorithm was tested using the threshold between 10ms and 100ms on two databases, namely the MIT-BIH Atrial Fibrillation Database.

Biological Assay of Mercury and Cadmium Ions Using DNA Immobilized on a Nanotube Paste Electrodes

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Hong-Rak;Park, Kwang-Ho;Park, Yong-Keun;Suk, Hong-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.302-310
    • /
    • 2012
  • Bio assay of mercury and cadmium ions were searched using voltammetric analysis using DNA doped carbon nanotube paste electrodes (DCP). The square-wave stripping voltammetryic optimized results indicated working ranges of 1-10.0 $ngL^{-1}$ and 20-100 $ugL^{-1}$, Hg(II) Cd(II) within an accumulation time of 120 seconds, in 0.1-M phosphate buffer solutions of pH 6.3. The relative standard deviations of 5 $ngL^{-1}$ Hg(II) and Cd(II) that observed were 0.14 and 0.22% (n=12), respectively, using optimum conditions. The low detection limit (S/N) was pegged at 0.1 $ngL^{-1}$ ($4.9{\times}10^{-11}M$) Hg(II) and 0.2 $ngL^{-1}$ ($1.77{\times}10^{-10}M$) Cd(II). The developed methods can be applied to assays in biological fish kidneys and water samples.

A Study of the Application of Earthquake Early Warning System for the Enhancements in Protective Action by Korea National Park (국립공원의 지진 대응 체계 개선을 위한 지진 조기경보 시스템의 적용에 관한 연구)

  • Yang, Eomzi;Ha, Seong Jun;Kim, Won Kyung;Yun, Tae Sup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.439-448
    • /
    • 2018
  • Conventional Earthquake Early Warning System (EEWS) detects the propagated P-wave from epicenter which should be achieved within 5 seconds to provide seconds to minutes of warning, allowing people to prepare for protective actions. EEWS in Korea is currently capable of providing a warning within 50 seconds after the primary P-wave detection, however, it is well-known that earthquake warning systems operating around Korean National Parks (KNP) have limited capability to fully monitor earthquake events. This study, therefore, presents a strategy to quantify the potential vulnerability to earthquake hazards by superimposing the distribution of Korea Integrated Seismic System (KISS) and the discretized map of KNP. Total 22 national parks are evaluated, and the results suggest that the improvement of the on-site systems should be necessitated for Gyoengju, Gyeryongsan, Songnisan, Gayasan, and Deogyusan national parks, whereas enhancement of regional systems is required for Bukhansan national park.

Electrochemical determination of chloramphenicol using a glassy carbon electrode modified with dendrite-like Fe3O4 nanoparticles

  • Giribabu, Krishnan;Jang, Sung-Chan;Haldorai, Yuvaraj;Rethinasabapathy, Muruganantham;Oh, Seo Yeong;Rengaraj, Arunkumar;Han, Young-Kyu;Cho, Wan-Seob;Roh, Changhyun;Huh, Yun Suk
    • Carbon letters
    • /
    • v.23
    • /
    • pp.38-47
    • /
    • 2017
  • In this study, magnetite ($Fe_3O_4$) nanoparticles were electrochemically synthesized in an aqueous electrolyte at a given potential of -1.3 V for 180 s. Scanning electron microscopy revealed that dendrite-like $Fe_3O_4$ nanoparticles with a mean size of < 80 nm were electrodeposited on a glassy carbon electrode (GCE). The $Fe_3O_4/GCE$ was utilized for sensing chloramphenicol (CAP) by cyclic voltammetry and square wave voltammetry. A reduction peak of CAP at the $Fe_3O_4/GCE$ was observed at 0.62 V, whereas the uncoated GCE exhibited a very small response compared to that of the $Fe_3O_4/GCE$. The electrocatalytic ability of $Fe_3O_4$ was mainly attributed to the formation of Fe(VI) during the anodic scan, and its reduction to Fe(III) on the cathodic scan facilitated the sensing of CAP. The effects of pH and scan rate were measured to determine the optimum conditions at which the $Fe_3O_4/GCE$ exhibited the highest sensitivity with a lower detection limit. The reduction current for CAP was proportional to its concentration under optimized conditions in a range of $0.09-47{\mu}M$ with a correlation coefficient of 0.9919 and a limit of detection of $0.09{\mu}M$ (S/N=3). Moreover, the fabricated sensor exhibited anti-interference ability towards 4-nitrophenol, thiamphenicol, and 4-nitrobenzamide. The developed electrochemical sensor is a cost effective, reliable, and straightforward approach for the electrochemical determination of CAP in real time applications.

The influence of misinformation on memory: detection of original memory using concealed information test (CIT) (기억에 대한 오정보의 영향: 숨긴정보검사를 이용한 원기억의 탐지)

  • Han, Yuhwa;Park, Kwangbai
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.85-100
    • /
    • 2015
  • This study aimed at examining if the original memory remains after a misinformation is presented, using Event-Related Potential based Concealed Information Test (ERP-based CIT). In the first stage of the study, the participant was presented with either the original information or a misleading information after experiencing an event (Post-information). The second stage was to measure brain wave and reaction time on the original, misleading, and irrelevant information (CIT-Stimulus). P300 amplitude, P300 area, P300 latency, and reaction time were used as dependant variables. In the result, a significant Post-information ${\times}$ CIT-Stimulus interaction effect was found on the P300 area measured at Cz, Pz, and Oz area. This interaction effect implied the possibility that the original information could be partially impaired in memory by misleading information presented afterward. P300 amplitude at Pz area did not differ between the accurate and the misleading stimuli in the condition in which a misleading information was presented. This result can be explained by source monitoring error. In discussion, the limitations of this study and directions of future studies were discussed.

S-Wave Velocities Beneath Jeju Island, Korea, Using Inversion of Receiver Functions and the H-κ Stacking Method (수신함수 역산 및 H-κ 중합법을 이용한 제주도 하부의 S파 지각 속도)

  • Jeon, Taehyeon;Kim, Ki Young;Woo, Namchul
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2013
  • Shear-wave velocity ($v_s$) structures beneath two seismic stations, JJU and JJB on the flanks of the volcano Halla on Jeju island, Korea, were estimated by receiver-function inversion and H-${\kappa}$ stacking applied to 150 teleseismic events ($M_W{\geq}5.5$) recorded since 2007. $P_S$ waves converted at the Moho discontinuity does not appear clearly for northwesterly back-azimuths ($207{\sim}409^{\circ}$, average $308^{\circ}$) at station JJU and southeasterly back-azimuths ($119{\sim}207^{\circ}C$, average $163^{\circ}$) at station JJB. This may be due to a gradual velocity increase at Moho or heterogeneity within the crust. The $v_s$ models derived by inversion of receiver functions indicate a distinct low velocity layer ($v_s{\leq}3.5km/s$; LVL) within the crust and a gradual increase in $v_s$ in the depth interval of 30 to 40 km. Within the radius of 18 km beneath station JJB, the LVL occurs at depths of 14 ~ 26 km and the 'Moho' ($v_s{\geq}4.3km/s$) is at 34 km depth. Ten kilometers to the west, within the radius of 16 km beneath station JJU, both the LVL and the Moho are significantly shallower, at depths of 14 to 24 km and 30 km, respectively. H-${\kappa}$ analyses for stations JJU and JJB yield estimated crustal thickness of 29 and 33 km and $v_p/v_s$ ratios of 1.64 and 1.75, respectively. The lesser $v_p/v_s$ ratio was derived for rocks nearest to th peak of the volcano.

The Utility of Contrast Enhanced Ultrasound and Elastography in the Early Detection of Fibro-Stenotic Ileal Strictures in Children with Crohn's Disease

  • Sarah D. Sidhu ;Shelly Joseph;Emily Dunn;Carmen Cuffari
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2023
  • Purpose: Crohn's disease (CD) is a chronic, idiopathic bowel disorder that can progress to partial or complete bowel obstruction. At present, there are no reliable diagnostic tests that can readily distinguish between acute inflammatory, purely fibrotic and mixed inflammatory and fibrotic. Our aim is to study the utility of contrast enhanced ultrasound (CEUS) in combination with shear wave elastography (SWE) to differentiate fibrotic from inflammatory strictures in children with obstructive CD of the terminal ileum. Methods: Twenty-five (19 male) children between 2016-2021 with CD of the terminal ileum were recruited into the study. Among these patients, 22 had CEUS kinetic measurements of tissue perfusion, including wash-in slope (dB/sec), peak intensity (dB), time to peak intensity (sec), area under the curve (AUC) (dB sec), and SWE. In total, 11 patients required surgery due to bowel obstruction. Histopathologic analysis was performed by a pathologist who was blinded to the CEUS and SWE test results. Results: Patients that underwent surgical resection had significantly higher mean area under the curve on CEUS compared to patients responsive to medical therapy (p=0.03). The AUC also correlated with the degree of hypertrophy and the percent fibrosis of the muscularis propria, as determined by histopathologic grading (p<0.01). There was no difference in the mean elastography measurements between these two patient groups. Conclusion: CEUS is a useful radiological technique that can help identify pediatric patients with medically refractory obstructive fibrotic strictures of the terminal ileum that should be considered for early surgical resection.

Study on Reduction of Microbial Contamination on Daruma by Combination Treatment of Strong Acidic Hypochlorous Water and Ultrasonic Waves (강산성차아염소산수와 초음파를 병용처리한 조미오징어 반가공품의 미생물 오염도 저감화에 관한 연구)

  • Chung, Won-Hee;Ko, Jun-Soo;Shin, Il-Shik
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.166-172
    • /
    • 2015
  • This study was performed to develop treatment method for reducing microbial contamination on Daruma (a semi-processed product of seasoned and dried squid) by combination of strong acidic hypochlorous water (SAHW) and ultrasonic waves (UW). The available chlorine concentration, oxidation reduction potential (ORP) and pH of SAHW were $69.67{\pm}0.58ppm$, $1071.33{\pm}4.16mV$ and 2.79, respectively. The 1.49 log CFU/g of viable cell count and 1.32 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of sodium hypochlorite solution (SHS) for 120 min. The 3.62 log CFU/g of viable cell count and 3.22 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 120 min. The antibacterial effects of SAHW were stronger than those of SHS at same available chroline concentration. SAHW treatment after washing strongly alkalic electrolyzed water (SAEW) showed better bactericidal effects than SAHW treatment only. The 4.0 log CFU/g of viable cell count was reduced, S. aureus was reduced below regulation limit (Log 2.0 CFU/g), and E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 90 min after washing with 20 times (w/v) of SAEW for 60 min. The viable cell number was reduced below detection limit and S. aureus was reduced below regulation limit when the Daruma was treated with 20 times (w/v) of SAHW for 60 min in ultrasonic washer. E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 10 min in ultrasonic washer. These results suggest that combination of SAHW and UW may be a good technique to reduce the microbial contamination in daruma.

Usefulness of auditory brainstem response as early predictor of kernicterus in early breast-feeding jaundice (조기 모유 황달에서 핵황달의 조기 예측도구로서의 청성 뇌간유발 반응 검사의 유용성)

  • Jang, Jae Won;Lee, Gil Sang;Song, Dae Keun;Kim, Sung Hee;Kim, Won Duck;Lee, Sang Geel
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.9
    • /
    • pp.848-854
    • /
    • 2007
  • Purpose : The present study examined the etiology and risk factors of the early breast-feeding jaundice and the usefulness of auditory brainstem response test as early predictor of kernicterus. Methods : Medical records of neonatal jaundice in newborn admitted to Daegu Fatima Hospital between September 2005 and May 2006 were analyzed prospectively. Infants were grouped according to feeding method : breast feeding group (breast feeding only, n=23), mixed feeding group (breast feeding mainly plus addition of fomula feeding, n=13). Results : There were no significant differences in gestational age, birth weight, sex, duration of phototherapy, serum bilirubin and hemolytic evidence between the two study groups. First visiting day of life at out patient department was significantly delayed in breast feeding group ($8.7{\pm}3.6day$) compared to mixed feeding group ($6.0{\pm}1.9$) (P=0.009). Weight loss was significantly severe in breast feeding group compared to mixed feeding group (P<0.05). In auditory brainstem response test, loss of Wave V in 3 cases was observed and recoverd after blood exchange transfusion in follow up test.Wave III latency had significant correlation to serum bilirubin in auditory brainstem response test (70 dB) (P=0.002). Conclusion : Our study suggest that further education about breast feeding and follow up within the first postnatal week would be necessary for early detection and prevention of early breast-feeding jaundice. Test of serum bilirubin and auditory brainstem response would be helpful in determination of blood exchange transfusion.