• Title/Summary/Keyword: P-value Method

Search Result 2,682, Processing Time 0.039 seconds

A Study on the Characteristics of Pine-tree Mushroom(Tricholoma matsutake Sing.) Pickle for the Standard Recipe (냉동 자연 송이버섯의 피클 조리법 표준화를 위한 연구)

  • Park, Mi-Lan
    • Culinary science and hospitality research
    • /
    • v.14 no.4
    • /
    • pp.55-66
    • /
    • 2008
  • This study investigated the rheological and sensory characteristics of pickle with frozen pine mushroom. P3(Developed pickle seasoning) was the best by preference among three kinds of pine mushroom pickle seasoning. For flavor and functionality, pine mushroom pickle was processed by using three kinds of method(P3-1: P3+cinnamon 10 g, P3-2: P3+licorice 10 g and P3-3: P3+licorice 5 g+cinnamon 5 g). As a result, the product from P3-3(P3+licorice 5 g+cinnamon 5 g) was the best preferred pine mushroom pickle. The pH value of P3-3 was 2.15, 42.9 degrees Brix, and its color value was L(54.65), a(-1.61), b(17.87). Its texture level was higher than that of other products, but it would be lowered on storage. Until the 28th day of storage, microorganisms in pine mushroom pickle seasoning were detected less than 30 CFU/mL.

  • PDF

Development of pH-Responsive Core-Shell Microcapsule Reactor

  • Akamatsu, Kazuki;Yamaguchi, Takeo
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.191-194
    • /
    • 2004
  • A novel type of intelligent microcapsule reactor system was prepared. The reactor can recognize pH change in the medea and control reaction rate by itself. For the reactor system, acrylic acid (AA), N-isopropylacrylamide (NIPAM), and glucose oxidase (GOD) were selected as a pH-responsive device, a gating device according and a reaction device, respectively. Poly(NIPAM-co-AA) (P-NIPAM-co-AA) are known to change its hydrophilicity-hydrophobicity due to pH change. They were integrated in a core-shell microcapsule space. GOD was loaded inside the core space and the pores in the outside shell layer were filled with P-NIPAM-co-AA linear grafted chains as pH-responsive gates by plasma graft filling polymerization method. When P-NIPAM-co-AA gates are hydrophilic at high pH value, this microcapsule permits glucose penetration into the core space and GOD reaction proceeds. However, when P-NIPAM-co-AA gates are hydrophobic at low pH value, this microcapsule forbids glucose penetration and GOD reaction will not occur. The accuracy of this concept was examined.

  • PDF

A STUDY ON THE PROBABILISTIC PRODUCTION COST SIMULATION BY THE EFFICIENT LARGE DEVIATION METHOD (효율적인 LARGE DEVIATION 방법에 의한 발전 시뮬레이션에 관한 연구)

  • Song, K.Y.;Cha, J.M.;Kim, Y.H.;Oh, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.244-246
    • /
    • 1990
  • This paper describes the Large Deviation Method for computing the loss-of-load-probability (L.O.L.P.) index for a generating system. Also, we introduce a rule to prevent the initial value from diverging in Newton-Raphson method which we have to use to determine the value of t. By applying the Large Deviation Method to computing the L.O.L.P. index for some representative reliability test systems, it is verified that the Large Deviation Method is generally very accurate and very fast.

  • PDF

Development of Shape Optimization System using Stress Control (응력 제어를 통한 형상 최적화 시스템 개발)

  • 한석영;배현우
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.3
    • /
    • pp.52-58
    • /
    • 1999
  • In this study, the growth-strain method was used for shape optimization. The adequate value of growth ratio in the method was used the value obtained by volume control. And the linear PID control theory was applied to control internal stresses by stresses required by a designer. The effect of the values of $K_{P}$, $K_{I}$, and $K_{D}$ was investigated and the adequate values of $K_{P}$, $K_{I}$, and $K_{D}$ were determined empirically. Finally, a shape optimal design system was built up by the improved the growth-strain method with a commercial software I-DEAS. The effectiveness and practicality of the developed shape optimal design system was verified by some examples.les.les.les.

  • PDF

Rheological Studies on the Aqueous Suspension of Korean Bentonite (국산벤토나이트 현탁액의 유동학적 성질)

  • Kim, Eun-Hee;Rhee, Gye-Ju
    • YAKHAK HOEJI
    • /
    • v.34 no.5
    • /
    • pp.302-310
    • /
    • 1990
  • A study has been made of the Korean bentonite aqueous suspension contrast with American bentonite by means of XRD IR swelling, gel formation and rheogram at various conditions such as concentration, temperature and pH. The Korean bentonite was identified as montmorillonite clay containig a small proprotion of crystoballite and mordenite, and its swelling power were acceptable for requirements of Korean pharmacopeia regulations though its values were not satisfied. Korean bentonite swelled to 10 times and American one did to 15 times compared to its bulkiness of powder. The rheogram of Korean bentonite suspension reveals bulged pseudoplatic flow with yield value at higher concentration and pseudoplastic flow without yield value at lower concentration. The higher the concentration, the greater were the apparent viscosity and hysteresis loop. Korean bentonite suspension showed insignificant temperature dependence on both apparent viscosity and hysteresis loop and it was more temperature dependent on viscosity but less on hysteresis loop than those of American sample. The pH dependence was so high on viscosity that apparent minimum value was near pH 7 and maximum value at pH 3 or 7. The hysteresis loop appeared minimum over the pH range 5-7 and maximum near pH 3 or 11. The Korean bentonite was inferior to the American bentonite in swelling volume, gel formation, thioxotropy, however, it would be possible to improve the quality of Korean bentonite by developing the method of purification for bentonite clay.

  • PDF

H.P.L. Value in Serum of Normal Pregnancy and Pospartum State by Hemagglutination-Inhibition Reaction (정상(正常) 임산부(妊産婦)의 혈청중(血淸中) H.P.L.의 면역학적(免疫學的) 측정(測定)에 관(關)한 연구(硏究))

  • Chung, Ae-Rhee;Shin, Myun-Woo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.3 no.1
    • /
    • pp.13-19
    • /
    • 1976
  • Serum levels of human placental lactogen have been measured by hemagglutination-inhibition reaction in 67 normal pregnant state and in 15 postpartum 24 hour state, HAIR is less sensitive and reliable method than radioimmunoassay, but simple, rapid, less expensive and fairly accurate, so it is more helpful in screening of large antenatal population with or without high risk complications. 1) Sensitivity of HPL-HAIR test kit was $0.1{\mu}g$/ml of H.P.L. serum level and had no cross reaction to HCG or male serum or non-pregenant female or newborn infant, 2) H.P.L. value was around $2{\mu}g$/ml until 24th week of pregnancy and rose to $6{\sim}8$ ${\mu}g$/ml continuously until about 36th week of pregnancy and then slightly decreased or stationary. 3) H.P.L. value in postpartum 24 hour state was undetectable. 4) There was poor correlation between maternal serum H.P.L. value at term and baby weight.

  • PDF

CORRELATION ASSESSMENT BETWEEN RESONANCE FREQUENCY ANALYSIS AND RADIOGRAPHIC METHOD ACCORDING TO PERI-IMPLANT BONE CHANGE

  • Lee Mi-Ran;Cho Lee-Ra;Yi Yang-Jin;Choi Hang-Moon;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.736-744
    • /
    • 2005
  • Statement of problem. Initial stability of implant is an important factor for predicting osseointegration. It requires a rapid, non-invasive, user-friendly technique to frequently assess the implant stability and the degree of osseointegration. Purpose. The aim of this study was to evaluate the correlation between the resonance frequency analysis (RFA) and the radiographic method for peri-implant bone change under in vitro conditions. Material and Method. Twenty implants of 3.75 mm in diameter(Neoplant, Neobiotech, Korea) were used. To simulate peri-implant bone change, 2 mm-deep $45^{\circ}$ range horizontal defect and 2 mm-deep $90^{\circ}$ range horizontal defect area were serially prepared perpendicular to the X-ray beam after conventional implant insertion. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of implants and direct digital image was obtained. ISQ values and gray values inside threads were measured before and after peri-implant bone defect preparation. Results. Within a limitation of this study, ISQ value of resonance frequency analysis was changed according to peri-implant bone change (p<0.05) and gray value of radiographic method was changed according to peri-implant bone change (p<0.05). There was no correlation between the ISQ value and the gray value for peri-implant bone change (p>0.05). But, in horizontal defect condition, relatively positive correlation were between ISQ and gray values(r=0.663). Conclusion. This results provided a possibility that peri-implant bone change may be evaluated by both RFA and radiographic method.

Measurement Instruments for Superior Product Development: A Case Study of Deli Serdang Cassava in Indonesia

  • P, Remus Hasiholan;TARMIZI, Hasan Basri;RAHMANTA, Rahmanta;PURWOKO, Agus
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.5
    • /
    • pp.1139-1145
    • /
    • 2021
  • This study is aimed at developing a measurement instrument for the superior product development program of Deli Serdang cassava, Indonesia. This research population is the target population of Deli Serdang Micro, Small and Medium-sized Enterprises (MSMEs) which produces cassava. The sample was randomly selected and consisted of 300 MSMEs. The study method is research and development with confirmatory factor analysis using Amos software. The data collection technique was a questionnaire. Study results used the maximum likelihood method which showed that the validity and reliability instruments met the ideal loading factor value > 0.5 and a significance value of p (0.000). The model built also meets the fit criteria based on the Goodness of Fit Model Standard. All instruments are presented to build and measure the superior cassava product development program by Deli Serdang MSMEs. This superior product development program comprises (1) economic contribution (with a loading factor value of 0.76) (2) social aspects (with a loading factor value of 0.76) (3) cultural aspects (with a loading factor value of 0.99) and (4) institutional (with a loading factor value of 0.87). This result means that all instruments have proven construct validity.

A genome-wide association study (GWAS) for pH value in the meat of Berkshire pigs

  • Park, Jun;Lee, Sang-Min;Park, Ja-Yeon;Na, Chong-Sam
    • Journal of Animal Science and Technology
    • /
    • v.63 no.1
    • /
    • pp.25-35
    • /
    • 2021
  • The purpose of this study is to estimate the single nucleotide polymorphism (SNP) effect for pH values affecting Berkshire meat quality. A total of 39,603 SNPs from 1,978 heads after quality control and 882 pH values were used estimate SNP effect by single step genomic best linear unbiased prediction (ssGBLUP) method. The average physical distance between adjacent SNP pairs was 61.7kbp and the number and proportion of SNPs whose minor allele frequency was below 10% were 9,573 and 24.2%, respectively. The average of observed heterozygosity and polymorphic information content was 0.32 ± 0.16 and 0.26 ± 0.11, respectively and the estimate for average linkage disequilibrium was 0.40. The heritability of pH45m and pH24h were 0.10 and 0.15 respectively. SNPs with an absolute value more than 4 standard deviations from the mean were selected as threshold markers, among the selected SNPs, protein-coding genes of pH45m and pH24h were detected in 6 and 4 SNPs, respectively. The distribution of coding genes were detected at pH45m and were detected at pH24h.

Research on Optimizing Luminosity Factor Through Color Filter $Y_{1-X}G_X$, $Y_{1-X}P_X$ ($Y_{1-X}G_X$, $Y_{1-X}P_X$ 칼라필터를 통한 시감도 최적화 연구)

  • Kim, YongGeun;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.47-56
    • /
    • 2009
  • Purpose: To find optimized luminosity factor of color from light transmission filter. Methods: To make $Y_{1-x}G_{x}$, $Y_{1-x}P_{x}$ by using CR-39 compound within dipping method, mixing up Y(Yellow), G(green) and P(pink) for optimize eye sensitivity. Modeling for relative luminous efficiency(relative sensitivity) curves in Luminose transmission, it could be resolved by Multiplying sensitivity of eye within transmission rate of Lens ($P_f({\lambda}=T({\lambda}){\cdot}P({\lambda}).)$.). To evaluate Wavelength between 400~700 nm, relative luminous efficiency curve in Area and Height value is being used. Results: In color filter of $Y_{1-x}G_{x}$ position of x equals to 0.04, 0.1, 0.08, 0.12, 0.14, 0.5 at ${\beta}=S_1/S_0{\cdot}100$ each consist value of 76.1, 77.9, 80.7, 81.6, 80.2, 18.6 In color filter of $Y_{1-x}P_{x}$ position of x equals to 1.00, 0.2, 0.6, 0.8 at ${\beta}=S_1/S_0{\cdot}100$ each consist value of 74.3, 74.0, 70.5, 33.0 The result from experiment $Y_{1-x}P_{x}$ value less than $Y_{1-x}G_{x}$, from evaluating luminous efficiency curve and test was successfully optimized. Conclusions: Optimized relative luminous efficiency curve result have value of X=0.12-0.14 at $Y_{1-x}G_{x}$.

  • PDF