• Title/Summary/Keyword: P-loop

Search Result 521, Processing Time 0.037 seconds

A Model Calculation of Solar Microwave Burst Structure

  • Choi, Yong-Seok
    • Bulletin of the Korean Space Science Society
    • /
    • 1995.04a
    • /
    • pp.21-21
    • /
    • 1995
  • The structures of 17GHz microwave burst for bipolar sunspots have investigated. which included the effects of the projected shapes of radio sources as they traverse across the solar disk using a magnetic loop employing a model of solenoid coils. An ensemble of high-energy electrons confined in the loop be assumed. The projected brightnesls distributions of gyrosynchrotron emission in x- and o-modes are computed and converted into total intensity and circular polarization difference at 17GHz for various heliocentric distances using numerical integration of the transfer equation along the line of sight. The results of computations at 17GHz for optical thin case will be presented. and the effects of the orientation of the loop will be discussed in detail, as well as the effect of size, position, Structure, and polarization of the emission. Also the results of the various physical P8lrameters such as the strength of magnetic field. high and low energy cut-off of accelerated electrons. spectral index and density of electrons will be preslmted. After comparing the results of model calculation with observations. we found that the observations can be well explained in terms of a loop model and its projection effect.effect.

  • PDF

Stabilization Loop Design Method on Dynamic Platform

  • Kwon, Young-Shin;Kim, Doh-Hyun;Kim, Lee-Han;Hwang, Hong-Yeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.156.5-156
    • /
    • 2001
  • Stabilized tracking platform in a missile consisting of a flat planar antenna, pitch/yaw gimbals, gear trains, and current controlled DC drive motors for pitch and yaw gimbal must have a capability to track a target as an inertial sensor in the presence of missile body motion such as maneuvering and vibration. Because of this reason, tracking a target from dynamic platform requires a servo architecture that includes a outer tracking loop(position loop) and inner rate loop that stabilizes the line of sight(LOS). This paper presents a gimbaled platform model including nonlinear phenomena due to viscous and Coulomb friction based on experimental data and torque equilibrium equation, the design concept for the inner tacholoop having P controller structure ...

  • PDF

PWM-VSI controller of Three-phase UPS Using Stationary Reference Frame (정지좌표계를 이용한 3상 UPS용 PWM-VSI 제어)

  • Kim M.K.;Kim J.S.;Bang S.S.;Choi J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.965-968
    • /
    • 2003
  • This paper describes the PWM-VSI controller of three-phase UPS system using stationary reference frame. This controller meets the specification the UPS inverter output voltage even under the unbalanced or nonlinear load. This controller is also constructed with duble control loop of the outer voltage control loop and the inner current control loop. For the fast response of the output voltage control, yhr inner current control loop of the capacitor current os used. To get the good property against overshoot, the If controller us used. The outer voltage controller is designed with P controller and the high gain transfer function is used for the zero steady state error. All control gains of both controller is designed base on the CDM method.

  • PDF

Studies on the Interaction of Glut4 and Cytoskeletal Protein (Glut4와 Cytoskeletal Protein의 상호작용에 관한 연구)

  • 김미영;이경림
    • Biomolecules & Therapeutics
    • /
    • v.4 no.4
    • /
    • pp.398-401
    • /
    • 1996
  • The glucose transporters found in the plasma membrane of all animal cells are known to have 12 putative transmembrane domains. Among 7 cytoplasmic loops, the fourth loop is the largest one. Since previous studies showed that cofilin, an actin-modulating protein, was found to interact with the largest cytoplasmic loop of (Na, K)ATPase, we tested if cofilin interacts with the largest cytoplasmic loop of Glut4. We demonstrated by the two-hybrid system that the largest cytoplasmic loop of Glut4 did not show any interaction with cofilin, suggesting that cofilin is not required for the membrane targeting process of other membrane proteins but only for a P-type ATPase.

  • PDF

Robust controller design and performance analysis of seeker scan-loop (탐색기 주사루프의 강인 제어기 설계와 성능분석)

  • Lee, Ho-Pyeong;Hwang, Hong-Yeon;Song, Chang-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.2
    • /
    • pp.110-119
    • /
    • 1994
  • The Robust Controller for scan-loop is designed using LQG/LTR Methodology. The design and analysis of spiral, rosette and conical scan patterns are discussed. The perfermance and robustness of the LQG/LTR controller are analyzed through experiments and cpmpared with those of the P-controller. Especially to improve the scan performance at large look angle, the cage coil output is linearized using a binomial equation. It is demonstrated that the scan-loop system by the LQG/LTR control is very robust to phase uncertainties.

  • PDF

Effect of trimethyl-indium source depletion on InGaAsP epilayer grown by MOCVD (Trimethyl-indium 소스 고갈에 따른 InGaAsP 에피층의 특성 변화)

  • 김현수;오대곤;편광의;최인훈
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.400-405
    • /
    • 2000
  • We investigated the effect of TMIn (trimethly-indium) source depletion on InGaAs, InGaAsP and 1.55 $\mu\textrm{m}$ InGaAs/InGaAsP SMQW by using EPISON ultrasonic monitor for measuring the concentration of metalorganic/carrier gas mixtures. And the problems for the growth reproducibility in MOCVD was solved by using an EPISON ultrasonic monitor with closed-loop mode under the condition of TMIn source depletion. The saturation pressure of TMIn was dramatically decreased over consumption of 80%. In the case of bulk epilayer, Up-shifting of 300 arcsec to Ga-rich direction and FWHM broadening by a factor of two in DCXRD spectrum were observed due to the TMIn source depletion. In the case of SMQW, Up-shifting of 300 arcsec to Ga-rich direction in DCXRD spectrum and blue-shift of 40 nm in PL spectrum were observed due to the TMIn source depletion. However, good reproducibility ($\Delta\theta$<$\pm$100 arcsec) was achieved even the condition of 95% of TMIn consumption, when we used the EPISON with closed-loop mode.

  • PDF

Improvement of the Optimum pH of Aspergillus niger Xylanase towards an Alkaline pH by Site-Directed Mutagenesis

  • Li, Fei;Xie, Jingcong;Zhang, Xuesong;Zhao, Linguo
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • In an attempt to shift the optimal pH of the xylanase B (XynB) from Aspergillus niger towards alkalinity, target mutation sites were selected by alignment between Aspergillus niger xylanase B and other xylanases that have alkalophilic pH optima that highlight charged residues in the eight-residues-longer loop in the alkalophilic xylanase. Multiple engineered XynB mutants were created by site-directed mutagenesis with substitutions Q164K and Q164K+D117N. The variant XynB-117 had the highest optimum pH (at 5.5), which corresponded to a basic 0.5 pH unit shift when compared with the wild-type enzyme. However, the optimal pH of the XynB-164 mutation was not changed, similar to the wild type. These results suggest that the residues at positions 164 and 117 in the eight-residues-longer loop and the cleft's edge are important in determining the pH optima of XynB from Aspergillus niger.

$Co_2$ Corrosion Mechanism of Carbon Steel in the Presence of Acetate and Acetic Acid

  • Liu, D.;Fu, C.Y.;Chen, Z.Y.;Guo, X.P.
    • Corrosion Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.227-232
    • /
    • 2007
  • The corrosion behavior of carbon steel (N80) in carbon dioxide saturated 1%NaCl solution with and without acetic acid or acetate was investigated by weight-loss test, electrochemical methods (polarization curve, Electrochemical impedance spectroscopy). The major objective is to make clear that the effect of acetic acid and acetate on the corrosion of carbon steel in $Co_2$ environments. The results indicate that either acetic acid or acetate accelerates cathodic reducing reaction, facilitates dissolution of corrosion products on carbon steel, and so promotes the corrosion rate of carbon steel in carbon dioxide saturated NaCl solution. All Nyquist Plots are consisting of a capacitive loop in high frequency region, an inductive loop in medial frequency region and a capacitive arc in low frequency region. The high frequency capacitive loop, medial frequency inductive loop and low frequency capacitive arc are corresponding to the electron transfer reaction, the formation/adsorption of intermediates and dissolution of corrosion products respectively. All arc of the measured impedance reduced with the increase of the concentration of Ac-, especially HAc. However, the same phenomenon is not notable after reducing pH value by adding HCl. HAc is a stronger proton donor and can be reduced directly by electrochemical reaction firstly. Ac- can't participate in electrochemistry reaction directly, but $Ac^-$ an hydrate easily to create HAc in carbon dioxide saturated environments. HAc is as catalyst in $Co_2$ corrosion. As a result, the corrosion rate was accelerated in the presence of acetate ion even pH value of solution increased.

A Wide - Range Dual-Loop DLL with Programmable Skew - Calibration Circuitry for Post Package (패키지후 프로그램을 이용 스큐 수정이 가능한 광범위한 잠금 범위를 가지고 있는 이중 연산 DLL 회로)

  • Choi, Sung-Il;Moon, Gyu;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.408-420
    • /
    • 2003
  • This paper describes a Delay Locked Loop (DLL) circuit having two advancements : 1) a dual loop operation for a wide lock-range and 2) programmable replica delays using antifuse circuitry and internal voltage generator for a post-package skew calibration. The dual loop operation uses information from the initial time-difference between reference clock and internal clock to select one of the differential internal loops. This increases the lock-range of the DLL to the lower frequency. In addition, incorporation with the programmable replica delay using antifuse circuitry and internal voltage generator allows for the elimination of skews between external clock and internal clock that occur from on and off-chip variations after the package process. The proposed DLL, fabricated on 0.16m process, operates over the wide range of 42MHz - 400MHz with 2.3v power supply. The measured results show 43psec peak-to-peak jitter and 4.71psec ms jitter consuming 52㎽ at 400MHz.

Fabrications and measurements of single layer YBCO dc-SQUID magnetometers designed with parallel-loop pickup coil (Parallel-loop 검출코일을 가지는 단일층 YBCO dc-SQUID 자력계의 제작 및 특성 연구)

  • 유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.45-49
    • /
    • 2003
  • We have designed and fabricated the single-layer high $T_{c}$ SQUID magnetometer consisting of a directly coupled grain boundary junction SQUID with an inductance of 100 pH and 16 nested parallel pickup coils with the outermost dimension of 8.8 mm ${\times}$ 8.8 mm. The magnetometer was formed from a YBCO thin film deposited on an STO(100) bicrystal substrate with a misorientation angle of $30^{\circ}$. The SQUID magnetometer was further improved by optimizing the multi-loop pickup coil design for use in unshielded environments. Typical characteristics of the dc SQUID magnetometer had a modulation voltage of 40 $\mu\textrm{V}$ and a white noise of $30fT/Hz^{1}$2/. The SQUID magnetometer exhibited a 1/f noise level at 10 Hz reduced by a factor of about 3 compared with that of the conventional solid type pickup coil magnetometers and a very stable flux locked loop operation in magnetically disturbed environments.s.

  • PDF