• Title/Summary/Keyword: P-loop

Search Result 519, Processing Time 0.025 seconds

Adaptive Techniques for Joint Optimization of XTC and DFE Loop Gain in High-Speed I/O

  • Oh, Taehyoun;Harjani, Ramesh
    • ETRI Journal
    • /
    • v.37 no.5
    • /
    • pp.906-916
    • /
    • 2015
  • High-speed I/O channels require adaptive techniques to optimize the settings for filter tap weights at decision feedback equalization (DFE) read channels to compensate for channel inter-symbol interference (ISI) and crosstalk from multiple adjacent channels. Both ISI and crosstalk tend to vary with channel length, process, and temperature variations. Individually optimizing parameters such as those just mentioned leads to suboptimal solutions. We propose a joint optimization technique for crosstalk cancellation (XTC) at DFE to compensate for both ISI and XTC in high-speed I/O channels. The technique is used to compensate for between 15.7 dB and 19.7 dB of channel loss combined with a variety of crosstalk strengths from $60mV_{p-p}$ to $180mV_{p-p}$ adaptively, where the transmit non-return-to-zero signal amplitude is a constant $500mV_{p-p}$.

Effect of Substituted Residue 139 and 258 on Structural Changes of Mutant Tryptophan Synthase Pro96→Leu α-Subunit (트립토판 중합효소 α 소단위 잔기 치환체 Pro96→Leu의 구조 변화에 영향을 미치는 139 및 258 잔기의 치환 효과)

  • Lee, Joo-Youn;Jeong, Jae-Kap;Shin, Hae-Ja;Lim, Woon-Ki
    • Journal of Life Science
    • /
    • v.12 no.4
    • /
    • pp.464-468
    • /
    • 2002
  • Enzymatic activities and fluorescence spectroscopic properties of the double mutant proteins P96L/F139W, P96L/F258W and a triple mutant protein P96L/F139W/F258W of tryptophan synthase $\alpha$ subunit from Escherichia coli was examined to study tertiary and local structure changes around the tryptophan residues. The enzymatic activities of P96l./F139W and P96L/F258W were similar, but P96L/F139W/F258W had lower activity, as compared to wild type. The fluorescence intensities of double mutant, P96L/F139W and P96L/F258W, were decreased but that of a triple mutant, P96L/F139W/F258W, was increased when compared to wild type. The sum of the maximum fluorescence intensity (fluorescence intensity at the λ$_{max}$) for the double mutant proteins was not equal to the intensity seen in the triple mutant protein. The enzymatic activity and fluorescence data indicate that the replacement of Pro$^{96}$ longrightarrowLeu might affect on the stability of helix 8 and the loop located between strand 4 and helix4. The result suggests that the tertiary structure of triple mutant (P96L/F139W/F258W), being different from wild type, might have more compact residual structure at the vicinity of 139 and 258.8.

Fuzzy-based PID Controller for Cascade Process Control

  • Tummaruckwattana, S.;Pannil, P.;Chaikla, A.;Tirasesth, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.268-271
    • /
    • 2004
  • This paper describes the development of a fuzzy logic control based on PID controller to improve the performances of the control system using conventional PID controller for the cascade process control systems. The structure of the proposed control system consists of two fuzzy-based PID controllers. One is used to eliminate the input disturbances of the inner loop and the other is used to regulate output response of the outer loop. The fuzzy PID design is derived from the linear-time continuous function of the conventional PID controller. The performance of the proposed controller is verified by MATLAB/SIMULINK simulation. Results of simulation studies demonstrates the outstanding of the control system using fuzzy-based PID controller in terms of reduced overshoot and fast response compared with the conventional PID controller.

  • PDF

Study on MPPT controller using limit cycle (리미트 사이클을 이용한 MPPT 제어기에 대한 연구)

  • Kang Taekyung;Koh Kanghoon;Kwon Soonkurl;Suh Kiyoung;Nakaoka Mutsuo;Lee Hyunwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.160-163
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current-Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF

Measurement of weak magnetic signals using high-$T_c$ SQUID magnetometers in magnetically disturbed environment (High-$T_c$ SQUID 자력계를 이용한 자기잡음 환경에서의 미세자기신호 측정 및 분석)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • v.4 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The single layer direct-coupled YBCO SQUID magnetometers have been fabricated and characterized for the purpose of the measurement of weak magnetic signals in unshielded environment. Two types of magnetometers have been designed and fabricated using 10 mm$\times$ 10 mm substrates. We could operate the conventional 3-mm-wide solid pickup loop magnetometers more stably than the 12-parallel-line pickup loop magnetometers in laboratory environment. We developed a first-order electronic gradiometer system using the SQUID sensors with axial displacement of 80 mm without any mechanical alignment of magnetometers. The system with a software filter using calculation of discrete Fourier transform could record clearly weak pulse signal of 100 pT in a magnetically disturbed environment.

  • PDF

Disturbance-Observer-Based Robust H Switching Tracking Control for Near Space Interceptor

  • Guo, Chao;Liang, Xiao-Geng
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • A novel robust $H_{\infty}$ switching tracking control design method with disturbance observer is proposed for the near space interceptor (NSI) with aerodynamic fins and reaction jets. Initially, the flight envelop of the NSI is divided into small subregions, and a slow-fast loop polytopic linear parameter varying (LPV) model is proposed, to approximate the nonlinear dynamic of the NSI, based on the Jacobian linearization and Tensor-Product (T-P) model transformation approach. A disturbance observer is then constructed, to estimate the modeled disturbance. Subsequently, based on the descriptor system method, a robust switching controller is developed, to ensure that the closed-loop descriptor system is stable with a desired $H_{\infty}$ disturbance attenuation level. Furthermore, the outcome of the proposed switching tracking control problem is formulated as a set of linear matrix inequalities (LMIs). Finally, simulation results demonstrate the effectiveness of the proposed design method.

An Enhanced Architecture of CMOS Phase Frequency Detector to Increase the Detection Range

  • Thomas, Aby;Vanathi, P.T.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.198-201
    • /
    • 2014
  • The phase frequency detector (PFD) is one of the most important building blocks of a phase locked Loop (PLL). Due to blind-zone problem, the detection range of the PFD is low. The blind zone of a PFD directly depends upon the reset time of the PFD and the pre-charge time of the internal nodes of the PFD. Taking these two parameters into consideration, a PFD is designed to achieve a small blind zone closer to the limit imposed by process-voltage-temperature variations. In this paper an enhanced architecture is proposed for dynamic logic PFD to minimize the blind-zone problem. The techniques used are inverter sizing, transistor reordering and use of pre-charge transistors. The PFD is implemented in 180 nm technology with supply voltage of 1.8 V.

A 1.5V CMOS High Frequency Operational Amplifier for High Frequency Signal Processing Systems. (고주파 신호처리 시스템을 위한 1.5V CMOS 고주파 연산증폭기)

  • 박광민;김은성;김두용
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1117-1120
    • /
    • 2003
  • In this paper, a 1.5V CMOS high frequency operational amplifier for high frequency signal processing systems is presented. For obtaining the high gain and the high unity gain frequency with the 1.5V supply voltage, the op-amp is designed with simple two stages which are consisting of the rail-to-rail differential input stage and the class-AB output stage. The designed op-amp operates with the 1.5V supply voltage, and shows well the push-pull class-AB operation. The simulation results show the DC open loop gain of 77dB and the unity gain frequency of 100MHz for the 1㏁ ┃ 10pF load. When the resistive load R$_1$. is varied from 1㏁ to 1 ㏀, the DC open loop gain decreases by only 4dB.

  • PDF

Empirical Closed Loop Modeling of a Suspension System Using Neural Network (신경회로망을 응용한 현가장치의 폐회로 시스템 규명)

  • Kim, I.Y.;Chong, K.T.;Hong, D.P.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.7
    • /
    • pp.29-38
    • /
    • 1997
  • A closed-loop system modeling of an active/semiactive suspension system has been accomplished through an artificial neural network. A 7DOF full model as a system's equation of motion has been derived and an output feedback linear quadratic regulator has been designed for control purpose. A training set of a sample data has been obtained through a computer simulation. A 7DOF full model with LQR controller simulated under several road conditions such as sinusoidal bumps and rectangular bumps. A general multilayer perceptron neural network is used for dynamic modeling and target outputs are fedback to the a layer. A backpropagation method is used as a training algorithm. Model validation of new dataset have been shown through computer simulations.

  • PDF

WH형 3-Loop 원전에 대한 분리형 및 일체형 가연성흡수봉 평가

  • 배성만;김양은;이상희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.33-38
    • /
    • 1996
  • 국내 WH형 가압경수로에서 V-5H 연료와 함께 사용되고 있는 분리형 가연성흡수봉인 WABA와 V-5H 연료의 5대 장점중 하나로 국외에서 널리 사용중인 일체형 가연성흡수봉인 IFBA에 대한 비교 평가를 수행하였다. WH형 3-Loop 원전을 대표한 영광 2호기를 대상으로 하여 4.2 w/o 농축도의 신연료 60개 장전을 가정하여 WABA 사용 노심, IFBA 사용 노심, WABA+IFBA 혼합사용 노심에 대한 최적 평형노심 장전모형을 선정하고 각각에 대한 노심특성 및 경제성을 평가하였다. 장전모형 선정 및 노심특성 분석에는 한전이 보유하고 있는 WH사의 APA (ALPHA/ PHOENIX-P/ANC) 7.8.0 코드체계를 사용하였으며 경제성 평가에는 POCO 코드를 사용하였다.

  • PDF