• 제목/요약/키워드: P-closed

검색결과 1,015건 처리시간 0.026초

SOME INVARIANT SUBSPACES FOR BOUNDED LINEAR OPERATORS

  • Yoo, Jong-Kwang
    • 충청수학회지
    • /
    • 제24권1호
    • /
    • pp.19-34
    • /
    • 2011
  • A bounded linear operator T on a complex Banach space X is said to have property (I) provided that T has Bishop's property (${\beta}$) and there exists an integer p > 0 such that for a closed subset F of ${\mathbb{C}}$ ${X_T}(F)={E_T}(F)=\bigcap_{{\lambda}{\in}{\mathbb{C}}{\backslash}F}(T-{\lambda})^PX$ for all closed sets $F{\subseteq}{\mathbb{C}}$, where $X_T$(F) denote the analytic spectral subspace and $E_T$(F) denote the algebraic spectral subspace of T. Easy examples are provided by normal operators and hyponormal operators in Hilbert spaces, and more generally, generalized scalar operators and subscalar operators in Banach spaces. In this paper, we prove that if T has property (I), then the quasi-nilpotent part $H_0$(T) of T is given by $$KerT^P=\{x{\in}X:r_T(x)=0\}={\bigcap_{{\lambda}{\neq}0}(T-{\lambda})^PX$$ for all sufficiently large integers p, where ${r_T(x)}=lim\;sup_{n{\rightarrow}{\infty}}{\parallel}T^nx{\parallel}^{\frac{1}{n}}$. We also prove that if T has property (I) and the spectrum ${\sigma}$(T) is finite, then T is algebraic. Finally, we prove that if $T{\in}L$(X) has property (I) and has decomposition property (${\delta}$) then T has a non-trivial invariant closed linear subspace.

불포화 자연토의 동전기 시스템에 따른 정화 특성 (The Remediation Characteristics of Natural Soil according to ElectroKinetic Remediation Systems under Unsaturated Conditions)

  • 김병일;김기년;한상재;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.873-881
    • /
    • 2004
  • A serious of EK remediation tests on contaminated soil are performed under unsaturated conditions and analyzed for electrical potential, water content, pH and so on. The results indicated that electrical potential and pH distributions in the sample are dependent on the amount and inward/outward flow of hydrogen ion. Specially, for the closed system the water content is largely decreased with the flow of hydrogen. The maximum electrical conductivity is measured at the catholyte of CEM(Sealing) test and directly related to the remedial efficiency. Although pHs in the region near to the anode are similarly developed, the different concentration of lead is measured with the electrical gradient contrary to the lead concentration dependent on pH within the sample.

  • PDF

REMARKS ON THE LIECHTI-STRENNER'S EXAMPLES HAVING SMALL DILATATIONS

  • Ham, Ji-Young;Lee, Joongul
    • 대한수학회논문집
    • /
    • 제35권4호
    • /
    • pp.1299-1307
    • /
    • 2020
  • We show that the Liechti-Strenner's example for the closed nonorientable surface in [13] minimizes the dilatation within the class of pseudo-Anosov homeomorphisms with an orientable invariant foliation and all but the first coefficient of the characteristic polynomial of the action induced on the first cohomology nonpositive. We also show that the Liechti-Strenner's example of orientation-reversing homeomorphism for the closed orientable surface in [13] minimizes the dilatation within the class of pseudo-Anosov homeomorphisms with an orientable invariant foliation and all but the first coefficient of the characteristic polynomial p(x) of the action induced on the first cohomology nonpositive or all but the first coefficient of p(x)(x ± 1)2, p(x)(x2 ± 1), or p(x)(x2 ± x + 1) nonpositive.

Two notes on "On soft Hausdorff spaces"

  • El-Shafei, M.E.;Abo-Elhamayel, M.;Al-shami, T.M.
    • Annals of Fuzzy Mathematics and Informatics
    • /
    • 제16권3호
    • /
    • pp.333-336
    • /
    • 2018
  • One of the well known results in general topology says that every compact subset of a Hausdorff space is closed. This result in soft topology is not true in general as demonstrated throughout this note. We begin this investigation by showing that [Theorem 3.34, p.p.23] which proposed by Varol and $Ayg{\ddot{u}}n$ [7] is invalid in general, by giving a counterexample. Then we derive under what condition this result can be generalized in soft topology. Finally, we evidence that [Example 3.22, p.p. 20] which introduced in [7] is false, and we make a correction for this example to satisfy a condition of soft Hausdorffness.

Simple P-I diagram for structural components based on support rotation angle criteria

  • Kee, Jung Hun;Park, Jong Yil
    • Advances in concrete construction
    • /
    • 제10권6호
    • /
    • pp.509-514
    • /
    • 2020
  • In the preliminary design phase of explosion-proof structures, the use of P-I diagram is useful. Based on the fact that the deformation criteria at failure or heavy damage is significantly larger than the yield deformation, a closed form solution of normalized P-I diagram is proposed using the complete plastic resistance curve. When actual sizes and material properties of RC structural component are considered, the complete plasticity assumption shows only a maximum error of 6% in terms of strain energy, and a maximum difference of 9% of the amount of explosives in CWSD. Thru comparison with four field test results, the same damage pattern was predicted in all four specimens.

초소형 밀폐형 이상 써모싸이폰 기포의 거동에 관한 해석적인 연구 (Analytical Study on the Behavior of the Bubble in the Micro Two-Phase Closed Thermosyphon)

  • 이윤표;이영수;이영
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.85-93
    • /
    • 1993
  • The rise of a large gas bubble or slug in a Micro Two-Phase Closed Thermosyphon with a thin wire insert has been analiged by the potential flow theory. The effect of the interfacial surface tension is explicitly accounted by application of the Kelvin-Laplace equation and solved for the bubble shape. The solution is expressed in terms of the Stokes stream function which consists of an infinite series of Bessel functions. The conditions of the bubble movement in a Micro Two-Phase Closed Thermosyphon were theoretically ascertained.

  • PDF

밀폐계 유동시스템내에서 고분자물질의 퇴화에 관한 실험적 연구 (An Experimental Study on the Degradation of Polymer in Closed Flow System)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권5호
    • /
    • pp.679-686
    • /
    • 1999
  • This study is to investigate the effect of a substantial drag reduction caused by the polymer(A611P) when the working fluids flow to the vertical direction in the vertical cylindrical equipment of closed flow system. The drag reduction is associated with the mechanical degrada-tion thermal degradation and heat transfer. By ignore the heat fluxs within the closed system the pressure drop due to the polymer concentration the flow velocity and flow time have been mea-sured. By taking into account the mechanical and thermal degradation in the closed system an experiment has been focused on the determination of the condition which could improve the pump capacity in the heat union electric power plant. Under the condition of non-boiling it has been found out that the change of heat flux has little influence on the drag reduction.

  • PDF

Trimethyl-indium 소스 고갈에 따른 InGaAsP 에피층의 특성 변화 (Effect of trimethyl-indium source depletion on InGaAsP epilayer grown by MOCVD)

  • 김현수;오대곤;편광의;최인훈
    • 한국진공학회지
    • /
    • 제9권4호
    • /
    • pp.400-405
    • /
    • 2000
  • 유기금속 소스의 농도를 연속적으로 in-situ 측정이 가능한 EPISON ultrasonic monitor를 이용하여 TMIn(trimethly-indium)의 소스 고갈이 InGaAs, InGaAsP bulk 에피층과 1.55 $mu extrm{m}$ InGaAs/InGaAsP SMQW (strained multi-quantum well)에 미치는 영향을 조사하였다. TMIn 소스는 사용량이 80%에서 급격하게 소스 고갈 현상을 보였다. TMIn 소스는 사용량이 80%에서 급격하게 소스 고갈 현상을 보였다. TMIn 소스 고갈에 의한 에피층의 특성 변화를 조사한 결과, bulk 에피층의 경우에는 소스가 고갈 되기 전에 성장한 에피층과 비교하여 DCXRD(double crystal X-ray diffractometry) spectrum에서 피크 분리가 약 300 arcsec정도 Ga-rich 방향으로 이동하였으며 relative FWHM은 약 2배 가량 증가하는 것을 보였다. SMQW 구조에서는 bulk 에피층과는 달리, PL 중심파장에서도 약 40 nm 정도 단파장쪽으로 이동하였으며, 피크 분리는 약 300 arcsec정도 Ga-rich 방향으로 이동하였다. 하지만, EPISON의 closed loop 기능을 사용할 경우에는 TMIn 소스 사용량이 95%에서도 피크 분리가 $\pm$100 arcsec이내의 재현성 있는 에피층 성장이 가능하다는 것을 알 수 있었다.

  • PDF

구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향 (THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR)

  • 이강;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제27권5호
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.