• Title/Summary/Keyword: P-beam source

Search Result 75, Processing Time 0.028 seconds

Characterization of GaN on GaN LED by HVPE method

  • Jung, Se-Gyo;Jeon, Hunsoo;Lee, Gang Seok;Bae, Seon Min;Kim, Kyoung Hwa;Yi, Sam Nyung;Yang, Min;Ahn, Hyung Soo;Yu, Young Moon;Kim, Suck-Whan;Cheon, Seong Hak;Ha, Hong Ju;Sawaki, Nobuhiko
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc1
    • /
    • pp.128-131
    • /
    • 2012
  • The selective area growth light emitting diode on GaN substrate was grown using mixed-source HVPE method with multi-sliding boat system. The GaN substrate was grown using mixed-source HVPE system. Te-doped AlGaN/AlGaN/Mg-doped AlGaN/Mg-doped GaN multi-layers were grown on the GaN substrate. The appearance of epi-layers and the thickness of the DH was evaluated by SEM measurement. The DH metallization was performed by e-beam evaporator. n-type metal and p-type metal were evaporated Ti/Al and Ni/Au, respectively. At the I-V measurement, the turn-on voltage is 3 V and the differential resistance is 13 Ω. It was found that the SAG-LED grown on GaN substrate using mixed-source HVPE method with multi-sliding boat system could be applied for developing high quality LEDs.

Organic Thin Film Transistors for Liquid Crystal Display Fabricated with Poly 3-Hexylthiophene Active Channel Layer and NiOx Electrodes

  • Oh, Yong-Cheul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1140-1143
    • /
    • 2006
  • We report on the fabrication of P3HT-based thin-film transistors (TFTs) for liquid crystal display that consist of $NiO_x$, poly-vinyl phenol (PVP), and Ni for the source-drain (S/D) electrodes, gate dielectric layer, and gate electrode, respectively The $NiO_x$ S/D electrodes of which the work function is well matched to that of P3HT are deposited on a P3HT channel by electron-beam evaporation of NiO powder. The maximum saturation current of our P3HT-based TFT is about $15{\mu}A$ at a gate bias of -30 V showing a high field effect mobility of $0.079cm^2/Vs$ in the dark, and the on/off current ratio of our TFT is about $10^5$. It is concluded that jointly adopting $NiO_x$ for the S/D electrodes and PVP for gate dielectric realizes a high-quality P3HT-based TFT.

Manufacture of an Acousto-Optical Spectrometer for Radio Astronomical Observations (우주전파관측용 음향광학 전파분광기의 제작)

  • 임인성;최재현;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1997
  • The acousto-optical spectrometer as a new type backend of the receiver system for radio astronomical observations is manufactured for radio signal analysis. We studied on the effect of Acousto-Optic and Acousto-Optic devices and designed the optics system. We manufactured the optical mount and the CCD detector for deflected beam and interface card. This acousto-optical spectrometer consisted of a laser, optics, acousto-optic deflector, CCD detector and Interface card. This system use He-Ne laser as a light source and use optics to get parallel beam and to focus the deflected beam. Acousto-optic deflector converts IF signal to ultrasonic wave and deflect the laser beam according to the Bragg deflection. The ultra wide band acousto-optic deflector has 1 GHz bandwidth and a total of 2,048 channel Charge Coupled Device for signal detection. In this study, we discuss the theoretical description on the effect of Acousto-optics, the design of the optics, manufacture of optical mount, CCD detector, interface card and we presented the results of experiment. As a result of measurement, we have 1,000 channels bandwidth from CCD channels.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Efficient excitation and amplification of the surface plasmons

  • Iqbal, Tahir
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1381-1387
    • /
    • 2018
  • One dimensional (1D) grating has been fabricated (using focused ion beam) on 50 nm gold (Au) film deposited on higher refractive index Gallium phosphate (GaP) substrate. The sub-wavelength periodic metal nano structuring enable to couple photon to couple with the surface plasmons (SPs) excited by them. These grating devices provide the efficient control on the SPs which propagate on the interface of noble metal and dielectric whose frequency is dependent on the bulk electron plasma frequency of the metal. For a fixed periodicity (${\Lambda}=700 nm$) and slit width (w = 100 nm) in the grating device, the efficiency of SPP excitation is about 40% compared to the transmission in the near-field. Efficient coupling of SPs with photon in dielectric provide field localisation on sub-wavelength scale which is needed in Heat Assisted Magnetic recording (HAMR) systems. The GaP is also used to emulate Vertical Cavity Surface emitting laser (VCSEL) in order to provide cheaper alternative of light source being used in HAMR technology. In order to understand the underlying physics, far-and near-field results has been compared with the modelling results which are obtained using COMSOL RF module. Apart from this, grating devices of smaller periodicity (${\Lambda}=280nm$) and slit width (w = 22 nm) has been fabricated on GaP substrate which is photoluminescence material to observe amplified spontaneous emission of the SPs at wavelength of 805 nm when the grating device was excited with 532 nm laser light. This observation is unique and can have direct application in light emitting diodes (LEDs).

Characteristics of nanolithograpy process on polymer thin-film using near-field scanning optical microscope with a He-Cd laser (He-Cd 레이저와 근접장현미경을 이용한 폴리머박막 나노리소그라피 공정의 특성분석)

  • Kwon S. J.;Kim P. K.;Chun C. M.;Kim D. Y.;Chang W. S.;Jeong S. H.
    • Laser Solutions
    • /
    • v.7 no.3
    • /
    • pp.37-46
    • /
    • 2004
  • The shape and size variations of the nanopatterns produced on a polymer film using a near-field scanning optical microscope(NSOM) are investigated with respect to the process variables. A cantilever type nanoprobe having a 100nm aperture at the apex of the pyramidal tip is used with the NSOM and a He-Cd laser at a wavelength of 442nm as the illumination source. Patterning characteristics are examined for different laser beam power at the entrance side of the aperture($P_{in}$), scan speed of the piezo stage(V), repeated scanning over the same pattern, and operation modes of the NSOM(DC and AC modes). The pattern size remained almost the same for equal linear energy density. Pattern size decreased for lower laser beam power and greater scan speed, leading to a minimum pattern width of around 50nm at $P_{in}=1.2{\mu}W\;and\;V=12{\mu}m/s$. Direct writing of an arbitrary pattern with a line width of about 150nm was demonstrated to verify the feasibility of this technique for nanomask fabrication. Application on high-density data storage is discussed.

  • PDF

Volumetric analysis of normal condyles and those with disc displacement with reduction in the Indonesian population: A CBCT study

  • Nawawi, Azkya Patria;Rikmasari, Rasmi;Kurnikasari, Erna;Oscandar, Fahmi;Lita, Yurika Ambar
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.103-108
    • /
    • 2022
  • Purpose: Disc displacement can cause resorption of the head of the condyle and affect its volume. This study analysed the volume of normal condyles and those with disc displacement with reduction (DDR) in cone-beam computed tomography (CBCT) scans from the Indonesian population. Materials and Methods: This study analysed 56 condyles (26 normal and 30 with DDR) from patients who visited the Oral and Maxillofacial Radiology Unit after being referred from the Prosthodontics Unit at Dental Hospital Universitas Padjadjaran from December 2020 to February 2021. Samples were divided into 2 groups (normal and DDR left and right-side condyles) based on the DC/TMD Axis 1 form through the clinical examination results. Both sample groups were exposed to CBCT radiation. The CBCT imaging results in the Digital Imaging and Communications in Medicine format were exported to the open-source ITK-SNAP format to determine condyle volume. Volumetric data from the cortical and trabecular areas of the right or left side condyles were arranged by sex. The independent t-test was used to determine the significance of differences with IBM SPSS version 21.0. Intra- and inter-observer reliability and validity were tested before determining the volume of the condyles. Results: Normal condyles and DDR condyles showed significant differences in volume (P<0.05). Significant differences were also seen in cortical (P=0.0007) and trabecular (P=0.0045) volumes. There was a significant difference in condylar volume based on sex. Conclusion: The normal condyle volume was significantly different from the DDR condyle volume in both sexes.

Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT (간의 단일선원 Twin Beam과 이중선원 이중에너지 전산화단층촬영의 비조영증강 영상과 가상 비조영증강 영상의 비교 연구)

  • Jeong Sub Lee;Guk Myung Choi;Bong Soo Kim;Su Yeon Ko;Kyung Ryeol Lee;Jeong Jae Kim;Doo Ri Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.170-184
    • /
    • 2023
  • Purpose To assess the magnitude of differences between attenuation values of the true non-contrast image (TNC) and virtual non-contrast image (VNC) derived from twin-beam dual-energy CT (tbDECT) and dual-source DECT (dsDECT). Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT (n = 32) or dsDECT (n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs (n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of ≤ 10 Hounsfield units (HU). Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference ≤ 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively. Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.

Sensitivity Analysis of Core Neutronic Parameters in Electron Accelerator-driven Subcritical Advanced Liquid Metal Reactor

  • Ebrahimkhani, Marziye;Hassanzadeh, Mostafa;Feghhi, Sayed Amier Hossian;Masti, Darush
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.55-63
    • /
    • 2016
  • Calculation of the core neutronic parameters is one of the key components in all nuclear reactors. In this research, the energy spectrum and spatial distribution of the neutron flux in a uranium target have been calculated. In addition, sensitivity of the core neutronic parameters in accelerator-driven subcritical advanced liquid metal reactors, such as electron beam energy ($E_e$) and source multiplication coefficient ($k_s$), has been investigated. A Monte Carlo code (MCNPX_2.6) has been used to calculate neutronic parameters such as effective multiplication coefficient ($k_{eff}$), net neutron multiplication (M), neutron yield ($Y_{n/e}$), energy constant gain ($G_0$), energy gain (G), importance of neutron source (${\varphi}^*$), axial and radial distributions of neutron flux, and power peaking factor ($P_{max}/P_{ave}$) in two axial and radial directions of the reactor core for four fuel loading patterns. According to the results, safety margin and accelerator current ($I_e$) have been decreased in the highest case of $k_s$, but G and ${\varphi}^*$ have increased by 88.9% and 21.6%, respectively. In addition, for LP1 loading pattern, with increasing $E_e$ from 100 MeV up to 1 GeV, $Y_{n/e}$ and G improved by 91.09% and 10.21%, and $I_e$ and $P_{acc}$ decreased by 91.05% and 10.57%, respectively. The results indicate that placement of the Np-Pu assemblies on the periphery allows for a consistent $k_{eff}$ because the Np-Pu assemblies experience less burn-up.

Evaluation of the Volume Changes of Grafted Bone Materials in Sinus Augmentation Procedure Using Dental Cone-beam CT (치과용 Cone-beam CT를 이용한 상악동 골 이식 후 나타난 골 이식재의 부피 변화평가)

  • Ohn, Byung-Hun;Seon, Hwa-Kyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • To evaluate the 3-dimensional features of the grafted bone with maxillary sinus augmentation and to assess the relation between the degree of bone resorption and the type of bone grafting source and implant, and the operation method. A retrospective chart review of patients receiving sinus augmentation procedures for implant positioning was conducted: radiographic analysis of the volume and area of bone grafts was performed. The volumetric remodeling.measured at 6 months after implant positioning as the percentage of residual bone graft.was correlated to type of graft materials and operation methods. 53 dental implants positioned with sinus bone graft in 15 patients at Wonkwang University Sanbon Dental Hospital. Computed tomography scans,taken implant positioning after 6 months, showed greater resorption values for the group of $Puros^{(R)}$ graft alone from the group of mixed with $Puros^{(R)}$ and various bone graft (P<0.05, respectively). And resorption values according to operation methods have statistically significant difference(P<0.05). Volume change ratio of bone graft showed greater values for the group of delayed implant position from the group of simultaneously implant placement with bone graft. Retrospective data analysis shows that the method of graft with $Puros^{(R)}$ alone may occur greater resorption of graft materials than mixed graft material with $Puros^{(R)}$ and other graft materials. The group of simultaneously implant placement with bone graft also display smaller resorption ratio of bone graft than the group of delayed implant placement.