Photosynthesis and Respiration (P&R) Analyzer Analysis Optimization for Microalgal Activity Evaluation (미세조류 활성도 평가를 위한 Photosynthesis and Respiration (P&R) Analyzer 분석조건 최적화)

  • Huh, Jae-Hee;Sim, Tae-Suk;Hwang, Sun-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.449-457
    • /
    • 2021
  • Photosynthesis and respiration rate of microalgae are important factors during advanced wastewater treatment research using microalgae, There are several equipments and measurement methods for measuring photosynthesis and respiration, with different challenges that occur during pretreatment and stabilization of the analysis process. Therefore, in this study, for accurate Photosynthesis and Respiration (P&R) analyzer measurement, the analysis process was divided into pre-processing, DO stabilization, and analysis stages and each was optimized to enable accurate evaluation. For this purpose, the effect of DO saturation of the sample on P&R analysis, DO stabilization according to the degassing flow rate, and photoinhibition of the OD level on photosynthesis was investigated. Based on our study results, when DO was supersaturated, photosynthetic efficiency decreased due to photorespiration, making it inappropriate as a P&R sample. In addition, 0.5 L-N2/min level was the optimal nitrogen degassing flow rate for DO desaturation. The inhibition of photosynthetic efficiency by self-shading caused by the increase in OD was observed from OD 2.0, and it was found that P& R analysis is preferably performed on samples with OD less than 2.0. In addition, based on the above three optimization results, an optimized P&R Analyzer instruction for accurate P&R analysis was also presented.

Foot Pressure Analysis of Chronic Low Back Pain Patients by Foot Analyzer (Foot analyzer를 이용한 만성 요통 환자들의 족저 압력 분석)

  • Kim, Eun-Joo;Cho, Yu-Jeong;Song, Mi-Yeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.4
    • /
    • pp.115-126
    • /
    • 2009
  • Objectives : The aim of this study was to evaluate whether the foot pressure distribution correlates with the lumbo-sacral curvature, and the Oswestry Disability Index in chronic low back pain patients. Methods : We measured the fore foot pressure and the rare foot pressure using the foot analyzer in 28 women subjects with chronic low back pain. The lumbo-sacral curvature and the Oswestry Disability Index(ODI) were also measured. Results : 1. Subjects with higher ODI(%) had significantly lower Fore foot pressure/Rare foot pressure ratio(F/R ratio) (p<0.01). 2. Lumbar lordotic angle and Ferguson angle were inversely related to ODI(%) (p<0.05, p<0.01). 3. Lumbar lordotic angle and Ferguson angle were positively related to F/R ratio (all p<0.05). Conclusions : Using the Foot Analyzer(FA-48S, Tech storm Inc.) we have shown that F/R ratio has significant correlation with the lumbo-sacral curvature and the Oswestry Disability Index. These result suggest that the Foot analyzer may be used in assessing back pain in chronic low back pain patients.

Implementation on the Portable Blood Gas Analyzer (휴대형 혈액가스 분석시스템의 구현)

  • Kang S.C.;Jeong D.U.;Bae J.W.;Shon J.M.;Shim Y.B.;Jeon G.R.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1032-1036
    • /
    • 2006
  • In this study, we implement the potable blood gas analyzer measuring pH, $pCO_2\;and\;pO_2$ of the arterial blood. The implemented system by this study is divided into hardware and software part and also the hardware portion is parted by mechanism and electronic circuit mit. The system program is composed of operating, washing, correcting and measuring program. And to correct the system, two-point calibration method is used, one-point calibration method is also added for more accuracy, and system program is coded. For verifying the implemented system, We examine to response property of each electrode. And evaluate accuracy of the system using standard reagent and was construed as statistical.

  • PDF

Evaluation and Application of Algae Online Analyzer for Alarming Algal Bloom and Water Quality Management of Korean Reservoirs (조류발생 경보 및 호수 수질관리를 위한 엽록소 자동측정기의 적용 및 타당성 연구)

  • Hwang, Su-Ok;Han, Myung-Soo;Kim, Baik-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.2 s.116
    • /
    • pp.257-264
    • /
    • 2006
  • In order to evaluate the application of Algae Online Analyzer (AOA), an instrument of automatic measurement of chlorophyll a concentration, was tested and compared with the acetone extraction method on the basis of microscopic counting of phytoplankton in field water (Paltang Reservoir). We simultaneously conducted AOA operation and extraction method with the same water sample, to compare both results of chlorophyll a measurement. Phytoplankton were enumerated by inverted microscope with the Sedgwick-Rafter chamber, and classified into the genus or species. According to the AOA measurement, the diatom most (83.6%) strongly contributed to the total chlorophyll a concentration, followed by chlorophyceae> cyanophyceae>cryptophyceae. Overall, the results of both AOA and extraction method showed a similar trend and significant correlation (r=0.87, n=302, p<0.001), however, there were some differences according to the season and species. In particular, the relationship between AOA Chl-a density of the diatom (r=0.73, p=0.010) and cyrptophyceae (.=0.83, p=0.00154) were siginificant, while chlorophyceae (r= -0.13) and cyanophyceae (r= -0.16) showed no clear relationship during the study period. Although we can not fully understand why there was difference between both mothods, AOA application for alarming algal bloom and water quality management during the algal bloom appears to be very relevant. However, the further study or technical upgrade of AOA measurement is required, especially in the case of low density of phytoplankton or species-specific measurement.

Methodological Comparison of the Quantification of Total Carbon and Organic Carbon in Marine Sediment (해양 퇴적물내 총탄소 및 유기탄소의 분석기법 고찰)

  • Kim, Kyeong-Hong;Son, Seung-Kyu;Son, Ju-Won;Ju, Se-Jong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.235-242
    • /
    • 2006
  • The precise estimation of total and organic carbon contents in sediments is fundamental to understand the benthic environment. To test the precision and accuracy of CHN analyzer and the procedure to quantify total and organic carbon contents(using in-situ acidification with sulfurous acid($H_2SO_3$)) in the sediment, the reference material s such as Acetanilide($C_8H_9NO$), Sulfanilammide($C_6H_8N_2O_2S$), and BCSS-1(standard estuary sediment) were used. The results indicate that CHN analyzer to quantify carbon and nitrogen content has high precision(percent error=3.29%) and accuracy(relative standard deviation=1.26%). Additionally, we conducted the instrumental comparison of carbon values analyzed using CHN analyzer and Coulometeric Carbon Analyzer. Total carbon contents measured from two different instruments were highly correlated($R^2=0.9993$, n=84, p<0.0001) with a linear relationship and show no significant differences(paired t-test, p=0.0003). The organic carbon contents from two instruments also showed the similar results with a significant linear relationship($R^2=0.8867$, n=84, p<0.0001) and no significant differences(paired t-test, p<0.0001). Although it is possible to overestimate organic carbon contents for some sediment types having high inorganic carbon contents(such as calcareous ooze) due to procedural and analytical errors, analysis of organic carbon contents in sediments using CHN Analyzer and current procedures seems to provide the best estimates. Therefore, we recommend that this method can be applied to measure the carbon content in normal any sediment samples and are considered to be one of the best procedure far routine analysis of total and organic carbon.

  • PDF

THE EFFECT OF FORMATION OF PAPER FROM EUCALYPTUS CHEMIMECHANICAL PULP ON PRINTABILITY

  • Kai-Tang HU;Guo-Min TAN;Qi-Rong FU;Nam-Soek CHO
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04b
    • /
    • pp.394-397
    • /
    • 1999
  • The relation between the paper formation analyzer by image process system and smoothness, compressibility uniform of ink absorption is studied. There results indicate that the paper with bad formation has higher apparent bulk than the paper with good formation. The bad formation of paper results in the nonuniform calendering and decrease of the compressibility. The bad formation of paper also results in deformation and omission of printing dots, which affects the reproduction of the printing images.

Comparison of the bovine blood gas parameters produced with three types of portable blood gas analyzers

  • Ro, Younghye;Choi, Woojae;Hong, Leegon;Kim, Eunkyung;Choe, Eunhui;Kim, Danil
    • Journal of Veterinary Science
    • /
    • v.23 no.4
    • /
    • pp.60.1-60.6
    • /
    • 2022
  • Background: A definite diagnosis should be made in the bovine practice field, however, it was difficult to perform laboratory analysis immediately. Currently, three types of portable blood gas analyzers are available in Korea. Objectives: This study aimed to evaluate the correlations among these three analyzers. Methods: Seventy-two plasma samples from Holstein-Friesian cows were used for blood gas analysis, and three instruments (EDAN i15 Vet, VETSCAN i-STAT, and EPOC) were operated simultaneously. Moreover, plasma calcium levels were compared between these portable analyzers and blood chemistry device, which is usually used in a laboratory environment. Pearson analysis was performed to confirm the correlation of each parameter produced with the three instruments and blood chemistry analyzer. Results: As results, high correlation was observed in parameters of pH, pO2, potassium ion, ionized calcium, and glucose (p < 0.001, r > 0.7). In addition, pCO2 showed a moderate correlation among the three analyzers (p < 0.001, r > 0.5), and there was no correlation among all instruments for sodium ions. There was also a high correlation between ionized calcium from the three portable devices and total calcium from the biochemistry analyzer (p < 0.001, r > 0.9). Conclusions: In conclusion, there was a high correlation between results from the three different blood gas analyzers used in the bovine clinical field in Korea. Thus, a consistent diagnosis can be made even with different equipment if the operator is aware of the strengths and weaknesses of each piece of equipment and operates it properly.

Evaluation of Autochemical Analyzer Toshiba 120 FR (자동화학 분석기 Toshiba 120 FR의 평가)

  • Park, Jum Gi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.98-109
    • /
    • 2004
  • The lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with another equipment was evaluated for the Toshiba-120FR chemistry autoanalyzer which was newly introduced at the Daejeon Veteran Hospital in Dec. 2003. Nineteen kinds of test for AST, ALT, ALP, LDH, GGT, TP, ALB, GLU, T-cho, T-bil, TG, UA, CAL, IP, AMY, HDL-C, LDL-C, Cre and BUN were performed to evaluate the lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with other equipment according to the NCCLS guidelines(EP5-A, EP6-P, EP9-A). The Toshiba-120FR autochemical analyzer showed good precision for all tested items. The data concerning the lower limit of detection, precision(total CV 0.47%~3.65%), setting method of target value, reportable range determination, recovery(93%~111%), linearity($R^2=0.997{\sim}0.999$), and comparison study(r=0.977~0.999) with other equipment was acceptable for all tested items. The results of evaluation for the Toshiba-120FR autochemical analyzer showed that this equipment could be used as an alternative to other equipment.

  • PDF

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.