• Title/Summary/Keyword: Oxygen saturation

Search Result 548, Processing Time 0.023 seconds

Effects of Mask Wearing Due to COVID-19 on Cardiovascular Function in Treadmill Exercise (COVID-19로 인한 마스크 착용이 보행 속도에 따라 심혈관계 기능에 미치는 영향)

  • Ki-Won, Nam;Dong-Yel, Seo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.4
    • /
    • pp.37-43
    • /
    • 2022
  • PURPOSE: To find out how wearing a mask due to COVID-19 affects cardiovascular function as the pace of walking changes. METHODS: Forty-nine college students (27 men, 22 women) were subjected to treadmill exercises without masks (Group I) and wearing masks (Group II). The body temperature, heart rate, oxygen saturation, and blood pressure were measured to determine the changes in cardiovascular function. These parameters were measured at rest (Control I), low-intensity (Control II), medium-intensity (Control III), and high-intensity (Control IV) before and after exercise. RESULTS: Significant differences in heart rate were observed between Control III and Control IV, and a significant difference in oxygen saturation was noted in Control IV. Significant differences in the exercise intensity change in Group II were as follows: Body temperature was Control IV compared to Control I and Control II, heart rate was Control III and Control IV compared to Control I and Control II, and Control IV compared to Control III. The heart rate was Control III and Control IV compared to Control I and Control II, Control IV for Control III, oxygen saturation was Control IV compared to Control I, blood pressure was Control II and Control III and Control IV compared to Control I, and Control IV compared to Control II. CONCLUSION: Exercising when wearing a mask affects the cardiovascular system. Therapists should consider the patient's condition when setting the exercise intensity. In particular, therapists should be more careful when setting the exercise intensity of patients with cardiovascular disease.

Comparison of Arterial Oxygen Saturation Measured by Pulse Oximetry at Different Sensor Sites in Neurocritical Patients (신경계 중환자의 측정부위별 맥박 산소포화도의 비교)

  • Jeon, Min-Jeong;Hwang, Sun-Kyung
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Purpose : This study aimed to compare peripheral pulse oxygen saturation (SpO2) values, measured at different monitoring sites, and arterial oxygen saturation (SaO2) of neurocritical patients. Methods : The study included 110 patients admitted to the neurosurgical intensive care unit of a university hospital. The patients' SpO2 values were measured in their index fingers, both second toes, both earlobes, and foreheads, using the patient monitoring system. These values were compared with the standard value of SaO2 measured using a blood gas analyzer. Data were analyzed using descriptive values, Pearson's correlation coefficients, Lin's concordance correlation coefficients (CCC), and Bland-Altman plots. Result : Regardless of the measuring site, SpO2 was correlated with the paired measurements of SaO2 (r=.40~.60, p<.001, CCC range=.40~.58). No significant bias in paired measurements of SpO2 and SaO2 was observed at all sites (-0.06~0.19%, p>.05). SpO2 values at the left finger and right earlobe had the narrowest range, with a 95% limits of agreement (LOA) (left finger -3.04~2.93% and right earlobe -3.18~2.79%). SpO2 at the index finger, on the side without an arterial catheter, had a narrower range of 95% LOA than that of the opposing finger (-3.00~2.97% vs. -3.73~3.26%). Conclusion : SpO2 at the finger without an arterial catheter had the highest level of precision. This study suggests using the index finger, on the side without an arterial catheter, for pulse oximetry in neurocritical patients.

Comparison of tolerance of red seabream, Pagrus major exposed to hypoxia with body size (저산소에 노출된 참돔(Pagrus major)의 개체 크기에 따른 내성 비교)

  • Ji-Do Han;Heung-Yun Kim
    • Journal of fish pathology
    • /
    • v.36 no.2
    • /
    • pp.379-388
    • /
    • 2023
  • Experiments were performed to investigate hypoxia tolerance with body size of red seabream (Pagrus major) at 24℃. The rate of oxygen consumption was measured at an interval of 10 min using automated intermittent-flow respirometry. The weight-specific standard metabolic rate (SMR, mg O2 kg-1hr-1) and critical oxygen saturation (Scrit, % air saturation) of the fish were measured under normoxic condition and progressive hypoxia with 0.6-786 g of fish weight (W), respectively. SMR typically decreased with increasing body weight based on SMR=351.59·W-0.195 (r2=0.934). Scrit was higher in larger fish than those of smaller fish in the range of 17.3-24.4%. The result of this study suggests that the smaller seabream can withstand in hypoxic waters better than the larger ones.

Effect of Aerobic Exercise using Bruce Protocol on Heart Rate, Oxygen Saturation, and Blood Pressure after Recovery from COVID-19 Infection (COVID-19 이환자의 브루스 프로토콜을 이용한 유산소 운동이 심박수, 산소포화도, 혈압에 미치는 영향)

  • Yeon-Seop Lee;Seung-Soo Yang;Seul-Gi Jang;Ji-Hee Seol;Ji-Eun Lee;Dong-Jin Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.2
    • /
    • pp.141-147
    • /
    • 2023
  • Purpose : This study aimed to find out the effect of aerobic exercise using Bruce protocol on heart rate, oxygen saturation, and blood pressure after recovery from COVID-19 infection. Methods : In this study, 34 students from D University located in J city were targeted, COVID-19 infected group (17 people) and non-COVID-19 non-infected group (17 people). The Bruce protocol using a treadmill was applied to the aerobic exercise of this study. The Bruce protocol has in the first stage of METs 4 (slope 10 %, speed 2.7 km/h). The second stage was METs 5 (slope 12 %, speed 4 km/h), and the third stage was METs 6 (slope 14 %, speed 5.4 km/h). All measurements were measured 3 times and the average value was used. Results : As a result of this study, as a result of comparing heart rate changes according to aerobic exercise using the Bruce protocol. EG group and the CG group increased significantly according to the progressive exercise load (METs 4~5), and in the third stage of the Bruce protocol between groups, The EG group showed a significantly lower heart rate. As a result of comparing changes in oxygen saturation and blood pressure, there was no significant difference between the EG and C groups according to the gradual exercise load. Conclusion : In conclusion, there was no difference between normal and pressure when MET of moderate intensity exercise (4 to 6) was applied to the effect on heart rate, oxygen saturation, and blood pressure in healthy adults who were fully recovered from COVID-19. Secondary side effects may occur when high intensity exercise with a MET of 6 or higher, so it is strongly recommended that hospitals or specialized institutions measure exercise and physical ability according to individual exercise intensity.

Experimental Investigation of Ion Mobility Measurements in Oxygen under Different Gas Pressures

  • Liu, Yun-Peng;Huang, Shi-long
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.852-857
    • /
    • 2017
  • In this paper, measurements of ion mobility were performed in oxygen at gas pressures of 44.52 - 101.19 kPa using the drift tube method. Over this pressure range, mobility values were within the limits of 1.796 to $3.821cm^2{\cdot}V^{-1}{\cdot}s^{-1}$ were determined and ion mobility shown to decrease non-linearly with increasing gas pressure towards a certain level of saturation. Ion mobility measured in air was lower than that measured in oxygen at the same gas pressure. Finally, a parameter correction method for calibrating the relationship between the ion mobility and gas pressure in oxygen was proposed.

COMPARATIVE STUDY OF SEVERAL TYPE PULSE OXIMETER AND OXYGEN SATURATION EXTRACTED FROM THEM (다종의 Pulse Oximeter에서 측정된 산소 분압도의 차이와 상호 비교 결과에 대한 보고)

  • Yoo, Seung-Hoon;Kim, Eung-Hak;Kwon, Soon-Won;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.494-498
    • /
    • 2000
  • A major concern in pediatric dentistry is maximizing risk management through optimal monitoring of respiratory function during sedation techniques, and Pulse Oximeter is one of the most popular devices for these purpose. Pulse Oximeter is non-invasive device for detecting the sensitive fraction between the saturated & desaturated hemoglobin. Several Studies proved that there is no significant difference between the $SpO_2$ and $SaO_2$. In this article, We examined three Pulse Oximeter $(3300MX^{(R)},\;OX90^{(R)},\;BPM200^{(R)})$. The Pulse Oximeter using shorter pulse beat averaging showed more sensitive reaction to the statue of the patient and lower saturation data. We compared pair of Pulse Oximeter applied to one patient at one time. and $BPM200^{(R)}$(using shorter pulse beat averaging) showed statistically low saturation.

  • PDF

Feedback Control of Dissolved Oxygen with Hardware Modification of Fermenter (발효기 하드웨어 변환을 이용한 용존산소 제어)

  • 이중헌;이인영;박영훈
    • KSBB Journal
    • /
    • v.15 no.3
    • /
    • pp.280-284
    • /
    • 2000
  • The simple imcroprocessor device was provided for the control of dissolved oxygen(DO) level. The DO analog signal output from fementer was used as a measurement variable and the agitation speed of fermenter was used as a manipulatio variable. Agitation speed was manipulated to maintain DO level above 10% of saturation condition during cell growth period with microprocessor. Since the experimental resultsshowed that the DO level was maintained above 10% and agitation speed was inverse proportional to DO level ithis simple control device can be used for the DO control of fermenter.

  • PDF

Measurement of Oxygen Saturation Concentration by Zeolite (제올라이트별 산소포화농도 측정 실험)

  • Park, Sung-Sik;Kim, Kwang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.617-622
    • /
    • 2018
  • Air is essential for human beings to survive, but urban air is polluted with soot and harmful gases, due to the increase in industrial development and the population. Thus, air pollution in large cities is of increasing interest in the research community. One of the plausible solutions to this problem is supplying sufficient oxygen to indoor spaces. The main principle of the oxygen generator is to separate oxygen from air using synthetic zeolite. Various synthetic zeolites have been applied to public indoor spaces with the focus being placed on the oxygen exchange quality. Among the characteristics of zeolites which can be applied to oxygen generators is their ability to adsorb nitrogen from the air and, in this way, generate only oxygen. Thus, we investigated the degree of nitrogen adsorption by five kinds of natural zeolite and LTA zeolite 3A, 4A, and 5A (two different sizes). Using the PSA method, the higher the degree of nitrogen adsorption, the higher the oxygen saturation concentration, it was found that the nitrogen adsorption degree of the 5A zeolite was the highest. 6% on average. It was also found that the size of the zeolite had a significant effect on the degree of nitrogen adsorption.

Characteristics of Synthesized Red Cells Using Bovine Hemoglobin as Oxygen Carrier

  • Cho, Eng-Haeng;Hah, Jong-Sik;Kim, Ku-Ja
    • The Korean Journal of Physiology
    • /
    • v.26 no.1
    • /
    • pp.37-44
    • /
    • 1992
  • The encapsulation of the Purified bovine hemoglobin with Phospholipids obtained from egg folk was performed using a rotary vacuum evaporator. The prepared Hb-containing liposome (hemosome) had good properties as artificial red blood cell. The shape and size of the hemosomes were measured by a phase contrast microscope and image analyzer. The function of the hemosome as oxygen carrier was tested by measuring oxygen saturation curve with blood gas analyzer and infusing it into rats. The prepared hemosome was 1.184 + 0.423 ${\mu}m$ in diameter and round in shape. $P_{50}$ value of the hemosome solution was 28 mmHg. The synthesized red cells seem to function as oxygen carrier, because the severely bled rats were prolonged in their life by transfusion of the hemosome solution containing bovine hemoglobin.

  • PDF

Early Summer Dissolved Oxygen Characteristics in Restored Streams in Seoul (서울시 복원하천들의 초여름 용존 산소량 특성 분석)

  • Thoenen, Casey;Choi, Woonsup;Choi, Jinmu
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.3
    • /
    • pp.336-347
    • /
    • 2013
  • This paper presents an evaluation of stream restoration projects in Seoul with a focus on dissolved oxygen. Five test sites across four streams were measured for dissolved oxygen (DO) in late May to early June in 2012 and compared against a set of minimum and maximum thresholds. Only one test site, Hwarang-cheon, showed measurements below 6 mg/l DO. Towards the upper limit, the Hwarangcheon site was the only tested stream which was not at risk of DO supersaturation. The Danghyeon-cheon site had the highest probability of supersaturation, with DO saturation exceeding 130% expected 86.5% of the time. When measured every hour during daytime, DO levels showed diurnal variations, peaking in the afternoon. However, they showed inconsistent results along transects of the streams. Overall, the streams are rich in DO. To maintain the streams in good standing, nutrient loading should be addressed to prevent potential algal bloom induced hypoxic events down the line.

  • PDF