• 제목/요약/키워드: Oxidation process

검색결과 2,156건 처리시간 0.032초

MBR 공정 적용을 위한 전처리 오존산화에 의한 형광증백제 제거 연구 (Study on the Removal of Fluorescent Whitening Agent by Pretreatment Ozone Oxidation for MBR Process Application)

  • 최장승;류승한;신동훈;이재훈;이수철;김성기;류재용;신원식;이슬기;박민수
    • 한국염색가공학회지
    • /
    • 제29권1호
    • /
    • pp.11-17
    • /
    • 2017
  • In this study, ozone oxidation experiment was carried out for the removal of fluorescent whitening agent which is widely used in textile dyeing and paper industry. The stilbene fluorescent whitening agent has been industrialized since the earliest, and the amount of current production is the highest. Due to the characteristics of the fluorescent whitening agent that can not be removed by conventional wastewater treatment methods, the fluorescent whitening agent in wastewater treatment has difficulty in using as recycled water in the process. Pre-treatment ozone oxidation experiment was conducted prior to the introduction of Membrane Bio Reactor(MBR) treatment process by converting biodegradable materials into biodegradable materials. The removal efficiencies of fluorescent whitening agents, a diaminostilbenedisulfonic acid derivative by ozone oxidation were evaluated by $UV_{254}$ Scan, $COD_{Mn}$, T-N and color using a synthetic wastewater sample ($COD_{Mn}=433.0mg/{\ell}$) and paper and paper mill wastewater ($COD_{Mn}=157.2mg/{\ell}$).

구리기둥주석범프의 전해도금 형성과 특성 (Formation and Properties of Electroplating Copper Pillar Tin Bump)

  • 소대화
    • 한국정보통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.759-764
    • /
    • 2012
  • 고밀도집적을 위하여 전기도금과 무전해도금법을 적용하여 구리기둥주석범프(CPTB)를 제작하고, 그 특성을 분석하였다. CPTB는 ${\sim}100{\mu}m$의 피치를 갖도록 KM-1250 건식감광필름(DFR)을 사용하여 먼저 구리기둥범프(CPB)를 도금 전착시킨 다음, 구리의 산화억제를 위하여 그 위에 주석을 무전해 도금하였다. 열-압력에 따른 산화효과와 접합특성을 위하여 전기저항계수와 기계적 층밀림 전단강도를 측정하였다. 전기저항계수는 산화두께의 증가에 따라서 증가하였고, 전단강도는 $330^{\circ}C$에서 500 N의 열-압력일 때 최고치를 나타냈다. 시뮬레이션 결과에 따르면, CPTB는 시간이 경과됨에 따라 통전면적의 크기 감소의 결과를 나타냈으며, 그것은 구리의 산화에 의해 크게 영향을 받는 것으로 확인되었다.

전기산화공법을 이용한 고농도폐수 처리공정의 모델링 및 최적화 (Modeling and Optimization of High Strength Wastewater Treatment Using the Electro Oxidation Process)

  • 이홍민;이상선;황성원;진동복
    • Korean Chemical Engineering Research
    • /
    • 제54권3호
    • /
    • pp.340-349
    • /
    • 2016
  • 본 연구에서는 정유산업의 유지 및 보수기간에 배출되는 고농도폐수의 COD (Chemical Oxygen Demand)를 효과적으로 제거하기 위해 전기산화공법을 적용하였다. 우선 산업에서 배출되는 실제 폐수를 처리하기 위하여 BDD전극을 개발하고, 개발된 전극을 이용하여 전류밀도, pH, 전해질농도, 반응시간 등과 같은 다양한 운전조건하에 실험을 진행하였다. 둘째, 이러한 실험결과를 이용하여 전기분해의 kinetic parameter를 산출한 후에, 이를 토대로 전기산화 처리설비를 수학적으로 모델링 하였다. 마지막으로, 기존에 정상운전 조건 시 사용하던 저 농도 폐수를 처리하는 공정의 유입조건에 맞추기 위하여 전기산화 처리설비의 설계 및 운전의 다양한 변수들을 최적화함으로써 보다 효율적인 폐수 전처리 시스템을 개발하였다. 본 연구를 통해 개발된 모델의 결정계수($R^2$)는 0.982로 상당히 작은 오차범위를 보여줌으로써 모델의 높은 정확도를 입증하였다.

화학적 산화법에 의한 부식산의 분해 처리기술에 관한 연구(I) - 광산화공정을 통한 부식산의 분해특성 분석 - (Characterization of Humic Acid in the Chemical Oxidation Technology(I) - Characteristics by Photocatalytic Oxidation Process -)

  • 김종부;이동석
    • 분석과학
    • /
    • 제13권2호
    • /
    • pp.234-240
    • /
    • 2000
  • 수질계의 부식산을 화학적 산화처리하기 위한 방법의 하나로 광산화공정을 도입하여 부식산의 특성 변화를 조사하였다. 광산화공정은 UV단독, UV/$TiO_2$ 및 UV/$H_2O_2$ 시스템을 실험하였다. UV 단독 조사시 TOC 제거율은 pH 7-9에서 가장 높았으며, 흡광도는 강알카리성 영역에서 감소율이 향상된 결과를 보였다. 각 시스템별로 처리도를 보면, UV/$TiO_2$ 시스템의 경우 $TiO_2$ 의 농도가 50ppm 일때 TOC 제거와 흡광도 감소의 효율이 높았으며 50ppm 이상을 투입해도 처리율에 변화가 없었다. UV/$H_2O_2$ 시스템에서는 과산화수소의 농도가 20mM이 최적의 주입농도로 조사되었으며, 그 이상 투입할 경우 TOC와 흡광도의 처리율이 저하되었다. 탄산이온을 첨가할 경우, TOC 제거율 및 UV 흡광도의 감소율 모두 감소하며, TOC 제거율이 흡광도 감소율에 비해 상대적으로 더 크게 나타났다.

  • PDF

Development of the Pilot System for Radioactive Laundry Waste Treatment Using UV Photo-Oxidation Process and Reverse Osmosis Membrane

  • Park, Se-Moon;Park, Jong-Kil;Kim, Jong-Bin;Shin, Sang-Woon;Lee, Myung-Chan
    • Nuclear Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.506-511
    • /
    • 1999
  • The pilot system for radioactive liquid laundry waste was developed with treatment capacity, 1ton/hr and set up in the Yong Kwang unit #4. The system is composed of tank module, RO systems and a UV/$H_2O$$_2$photo-oxidation unit. The RO system consists of the BW unit (low-pressure RO for brackish water desalination) and the SW unit (high-pressure RO for seawater desalination). The BW unit possesses 4 RO membranes and it can reduce the feed water volume down to 1/10. This concentrated feed water can be reduced again up to 1/10 in its volume in the SW unit composed of 4 RO membranes. The UV/$H_2O$$_2$ photo-oxidation process unit was used for the detergent degradation. The operation of the pilot system was carried out and verified in its capability through the continuous operation and concentration operation using the actual liquid waste from the power plant. The design criteria and data for industrialization were yielded. The efficiency of the UV/$H_2O$$_2$ photo-oxidation process and the optimum operational procedure were evaluated. The decontamination factors for radioactive cobalt and cesium were measured. This on-site test showed the experimental result in the DF$\geq$300 and volume reduction factor$\geq$100.

  • PDF

Electrochemical Advanced Oxidation of Lamotrigine at Ti/DSA (Ta2O5-Ir2O5) and Stainless Steel Anodes

  • Meena, Vinod Kumar;Ghatak, Himadri Roy
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.292-307
    • /
    • 2022
  • The study presents kinetics of degradation and mineralization of an anti-epileptic drug Lamotrigine (LAM) in the aqueous matrix by electrochemical advanced oxidation process (EAOP) on Ti/DSA (Ta2O5-Ir2O5) and Stainless Steel (SS) anodes using sodium sulphate as supporting electrolyte. On both the anodes, kinetic behaviour was pseudo-first-order for degradation as well as mineralization of LAM. On Ti/DSA anode, maximum LAM degradation of 75.42% was observed at an associated specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 100 ppm Na2SO4 concentration. Maximum mineralization attained was 44.83% at an associated specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 50 ppm concentration of Na2SO4 with energy consumption of 2942.71 kWh/kgTOC. Under identical conditions on SS anode, a maximum of 98.92% LAM degradation was marked after a specific charge (Q) of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 100 ppm concentration of Na2SO4. Maximum LAM mineralization on SS anode was 98.53%, marked at a specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 75 ppm concentration of Na2SO4, with energy consumption of 1312.17 kWh/kgTOC. Higher Mineralization Current Efficiency (MCE) values were attained for EAOP on SS anode for both degradation and mineralization due to occurrence of combined electro-oxidation and electro-coagulation process in comparison to EAOP on Ti/DSA anode due to occurrence of lone electro-oxidation process.

정수처리에서의 Peroxone ($O_3/H_2O_2$) 공정 (Peroxone ($O_3/H_2O_2$) Process in Drinking Water Treatment)

  • 손희종;염훈식;빈재훈
    • 대한환경공학회지
    • /
    • 제32권3호
    • /
    • pp.296-308
    • /
    • 2010
  • Peroxone 공정은 정수처리 공정에서 기존의 염소와 오존 공정들의 여러 가지 한계점들을 극복할 수 있는 공정이다. 과산화수소와 오존에 의해 생성되는 OH 라디칼은 다양한 유기성 오염물질들에 대해 빠른 산화분해 및 높은 제거효율을 나타낸다. Peroxone 공정을 운영하는데 있어 주요 과제는 OH 라디칼 생성을 저해시키는 또는 생성된 OH 라디칼을 소모시키는 scavenger들과 공존할 때 peroxone 공정의 효율을 높일 수 있는 방안을 강구하는 것이다. Bromate와 같은 무기성 산화 부산물의 생성을 최소화할 수 있는 방안과 peroxone 공정 처리 후 염소 소독시 생성되는 염소 소독부산물들의 생성을 보다 저감할 수 있는 방안에 대해서도 많은 연구가 필요하다. 또한, 수중에 잔류하는 과산화수소에 대한 문제이다. 잔류 과산화수소를 on-line으로 측정할 수 있는 정밀한 측정장비의 개발 및 보급이 우선되어야 peroxone 공정의 운영에 있어서 안전성이 확보될 수 있다. 이러한 과제들이 해결이 된다면 peroxone 공정은 보다 다양한 목적으로 정수처리에 효율적으로 적용될 수 있을 것이다.

하수처리수 재이용을 위하여 Sym-bio공정과 용존 오존 부상공정을 이용한 하수처리의 효율 분석 (A Treatment Efficiency of Wastewater by using Sym-Bio Process and Dissolved Ozone flotation Process for Water Reuse)

  • 박찬규;박재한;이경희;안윤희;고광백;정현철
    • 한국물환경학회지
    • /
    • 제24권1호
    • /
    • pp.86-90
    • /
    • 2008
  • Water reuse of effluent is limited, due to bacteria and chromaticity or turbidity which may result in low perception of water quality. Consequently, this study showed a method in the reuse of treated wastewater by a diversified treatment method, with separation of centralized reformation of aeration tank into pre-treatment with minimum installation of facilities, and post-treatment, applying advanced oxidation treatment. A pilot plant experiment was performed using Sym-Bio process adopting an NADH Sensor without modification of the exiting aeration tank. The Dissolved Ozone Flotation process, which is an advanced oxidation process, to treat the remaining organics, nutrients, chromaticity, turbidity and bacteria. As a result in the Sym-Bio process, the biological treatment, even on the condition of single stage reaction tank, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS and T-N were 96.6%, 84.6%, 88.25%, 95.1% and 71.0%, respectively, while that for T-P was 25.0%, which required further treatment. In the Dissolved Ozone Flotation process, the advanced oxidation treatment, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS, T-N, T-P, chromaticity, turbidity, bacteria, coliforms were 78.9%, 34.6%, 28.7%, 48.0%, 70.4%, 82.4%, 84.0%, 74.5%, 99.8% and 99.4%, respectively.

정밀여과법 하수재이용 공정에서 오존의 전처리 효과에 관한 연구 (Effect of Ozonation in Microfiltration Membrane for Wastewater Reuse)

  • 문성용;안세혁;이상협;박종훈;홍석원;최용수
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.535-543
    • /
    • 2006
  • The Ozone oxidation process was applied to increase the efficiency of reuse process when treating the secondary effluent by the membrane system. This paper focus on decreasing efficiency of membrane fouling, because of membrane fouling reduction by ozone and evaluation of application of the ozone oxidation. The feed water was secondary effluent from BNR process. The result shows that the ozone pretreatment can reduce membrane fouling effectively. Also, the improvement of treated water quality was obvious. The reduction of the membrane fouling led decrease of following pollutant and increase of lnner adsorptive ability of hydrophilic organic matter and decrease of molecular weight. MF membrane process alone can meet the domestic reuse water standards. And ozone pretreatment process also can increase the removal rates of turbidity, COD, nitrogen, and color.

Cyclitol 유도체 합성에 관한 연구 (제3보)-myo-Inositol의 전해 산화- (Synthesis of Cyclitol Derivatives (Ⅲ). Electrolytic Oxidation of myo-Inositol)

  • 손주환;남종우;김유옥
    • 대한화학회지
    • /
    • 제15권3호
    • /
    • pp.127-132
    • /
    • 1971
  • To obtain the various kinds of inosose stereomers, the process of electrochemical oxidation is more effective than chemical oxidation of myo-inositol. So that myo-inositol aqueous solution was electrolyzed by platinum and lead peroxide anode to confirming the occurrence of electrochemical oxidation. The result is that myo-inosose-2 is producing with high yield comparatively by electrolytic oxidation of myo-inositol. Also we studied about the relation between the electrolytic current efficiency and electrolytic temperature and anodic current density. The current efficiency is rising with lowering of electrolytic temperature identically in both anode such as platinum and lead peroxide and also rising with increasing of anodic current density in platinum anode, but inversely in lead peroxide.

  • PDF