• 제목/요약/키워드: Overvoltage

검색결과 359건 처리시간 0.028초

직류전차선로의 뇌과전압 해설 및 피뢰기와 가공지선 차폐효과 검토 (Analysis of Lightning Overvoltage and Shielding Effect of Arrester and Overhead Grounding Wire on DC Railroad)

  • 정채균;홍동석;이종범;조한구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권8호
    • /
    • pp.359-364
    • /
    • 2001
  • This paper presents the influence of the lightning overvoltage and the shielding effect of lightning arresters and overhead grounding wires on the DC railroad systems. Modeling of railroad system is established in ATPDraw to perform the simulation and the line constants of railroad were calculated using ATP_LCC. When a direct lightning strikes to the DC railroad, the result of simulation reveals that the shielding effect of arresters is reduced at messenger, trolly-wire, and the shielding effects of overhead grounding wire is over 90% than the case which does not include it. Therefore it is evaluated that overhead grounding wires should be installed in the DC railroad line.

  • PDF

PSCAD/EMTDC를 이용한 시송전계통의 고조파 공진현상 분석 (Analysis of the Harmonic Resonance of Primary Restorative Transmission System Using PSCAD/EMTDC)

  • 이흥재;조병관;이경섭;박성민;배주천;황봉환;이낭호;송인준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.31-33
    • /
    • 2003
  • Power system restoration following a partial or complete blackout starts with energizing of primary transmission lines. Because system changed rapidly during early restoration process, transformer energization and load pickup is executed to maintain the power system stability. However unexpected problem such as harmonic overvoltage may be arisen during energizing transformer. The reason of harmonic overvoltage is known as transformer saturation and magnetizing in-rush current and so on, but it is difficult to estimate the condition of occurrence. This paper describes the analysis of the harmonic overvoltage while unloaded transformer is energized using PSCAD/EMTDC.

  • PDF

IGBT 직렬 연결을 위한 게이트 구동기법 (An Improved Gate Control Scheme of Series Connected IGBTs)

  • 김완중;최창호;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.195-197
    • /
    • 1998
  • The large scale industry needs high voltage converters. Therefore series connection of power semiconductor devices is necessary. It is important to prevent a device induced the overvoltage above ratings by proper voltage balancing in the field of IGBT series connection. In addition, the overvoltage induced by a stray inductance has to be limited in the high power circuit. This paper proposes a new gate control scheme which can balance the voltage properly and limit the overshoot by control the slope of collector voltage under series connected IGBT turn-off transient. The propose gate control scheme limits the overvoltage by sensing the collector voltage and controlling the gate signal actively. The new series connected IGBT gate driver is made and its validity is verified by the experimental results for series connected IGBT circuit.

  • PDF

여자시스템과 동기발전기의 회전자 권선에 발생되는 과전압에 대한 보호회로 연구 (The study of the protection circuit about overvoltage between excitation system and synchronous machines)

  • 류호선;임익헌
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.188-192
    • /
    • 1997
  • In the case of synchronous machines, certain power system disturbances cause the induced rotor current to assume negative values when no static converter is present. A converter, however, prevents negative current from flowing, so that overvoltages occur. The overvoltages can be effectively limited as crowbar circuit using GTO. This newly proposed crowbar circuit with current limiting resistor absorbs energy when overvoltage comes from power system repeatedly and verified through experiment

  • PDF

혼합송전계통에서 재폐로 시행시 개폐과전압 해석 (Analysis of Switching Overvoltage on Operating Reclosing in Combined Transmission Systems)

  • 임광식;이종범;정채균;강지원;박흥석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.391-393
    • /
    • 2008
  • This paper is analysed by switching overvoltage on operating reclosing in 154 [kV] combined transmission systems. Combined transmission systems are modeled by EMTP/ATPDraw program. It is fault condition that simulate high resistance earth fault. The simulation is carried out considering variation of parameters such as resistance value of fault point and rate of underground line.

  • PDF

혼합배전계통에서 EMTP/ATPDraw를 이용한 개폐서지 해석 (A Study and Analysis on the Switching Surge Using EMTP/ATPDraw in Combined Distribution Systems)

  • 이장근;이종범;이재봉;김병숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.280-282
    • /
    • 2005
  • This paper describes switching overvoltage generated during transient state in 22.9kV combined distribution systems. For analysis, distribution overhead line, underground cable and surge arrester are modeled using EMTP/ATPDraw. Simulation results show switching overvoltage according to various kind of parameter and systems such as closing angle and cable length.

  • PDF

외부 전자파 펄스에 의해 전송선로에 유기되는 과전류 및 과전압 보호회로의 해석 (Analysis of Protection Circuits of Overcurent and Overvoltage on Transmission Line Induced by External Electromagnetic Pulse)

  • 하헌태;김세윤;이경재;오명환
    • 전자공학회논문지A
    • /
    • 제28A권1호
    • /
    • pp.8-14
    • /
    • 1991
  • A new algorithm for calculation of overcurrent and overvoltage at load for parallel two-wire transmission line with nonlinear protection circuits induced by and external electromagnetic pulse is suggested. The rigorous solution is obtained for a particular type of the incident waveform and protection circuit. The validity of our algorithm is checked by comparing numerical results to the analytic solution in the particular case.

  • PDF

방전등 안정기의 보호회로 기술 현황 (A Stuty of Protection Circuit for Discharge Lamp Ballast)

  • 한수빈;박석인;송유진;정학근;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.133-135
    • /
    • 2008
  • In a design of ballast for discharge lamp, various kind of protection circuit are essential for safe operation. In this paper, overvoltage and current detection, no-load detection, lamp-fault detection, end of lamp detection for protection are introduced. Individual circuit operation and their function are described with the base that all circuit form is similar with overvoltage protection circuit.

  • PDF

초고압 GAS Voltage Transformer의 장기 과전압 시험에 관한 연구 (The study on the Long-Term overvoltage test of EHV Gas Voltage Transformer)

  • 송희석;박경원;계장석;정장근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.157-159
    • /
    • 2002
  • In order to obtain reliability and extend life of GAS Voltage Transformer in GIS, it has to prevent aging by overvoltage considered to insulation characteristics of insulating material. This paper describes some characteristics of V-T characteristics and partial discharges.

  • PDF

3-레벨 GTO 인버터를 위한 과전압 제한회로 설계 (A Circuit Design for Clamping an Overvoltage in Three-level GTO Inverters)

  • 서범석;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.258-261
    • /
    • 1994
  • This paper presents a circuit design far clamping the overvoltages across the GTOs in three-level GTO inverters. The proposed circuit has two roles as follows; one is to minimize the power dissipation in each GTO. It can be achieved by clamping the overvoltage to half that of the DC-link voltage as exactly as possible. The other is to get blocking voltage balancing between the inner GTOs and the outer GTOs.

  • PDF