• 제목/요약/키워드: Overshoot voltage

검색결과 118건 처리시간 0.024초

출력 커패시터가 없는 위상천이 풀브릿지 컨버터의 전류 전향 보상을 이용한 출력 전압 제어 기법 (Output Voltage Control Technique Using Current Forward Compensation for Phase Shifted Full Bridge Converter Without Output Capacitor)

  • 신유승;백승우;김학원;조관열;강정원
    • 전력전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.40-47
    • /
    • 2022
  • At present, the low-voltage, high-current type power supply is mainly used for effective sterilization in the ballast water treatment system. Research on PSFB converters without output capacitors has been ongoing. Such converters effectively treat ballast water without a separate disinfectant through electric pulses by applying a pulse-type power to the output electrode without an output capacitor. However, in the case of the pulse-type electrolysis treatment method, voltage overshoot can occur due to abrupt voltage fluctuations when the load changes, resulting in circuit reliability problems because of the output capacitorless system. Therefore, a new voltage control algorithm is required. In this paper, we will discuss voltage control for pulsed electrolysis topology without an output capacitor. The proposed voltage control method has been verified using Simulation and experiment. The usefulness of the proposed control method has been proven by the experimental results.

도시철도 직류급전용 더블컨버터의 출력특성 향상을 위한 모드 변환 시 점호각 제어 연구 (A Study on the Firing Angle at the Mode Conversion to Improve the Output Characteristics of the Double Converter for Urban Railway DC Power Supply)

  • 서승삼;한성우;변기식
    • 한국철도학회논문집
    • /
    • 제18권6호
    • /
    • pp.533-542
    • /
    • 2015
  • 본 논문은 도시철도 전동차 정차 시에 발생하는 회생전력으로 인해 전차선 가선전압 상승 시에 Converter(Forward)에서 Inverter(Reverse)로 mode 변환하여 상승된 가선전압을 AC 모선으로 환류하여 전차선 전압을 일정하게 유지하고 전동차 정차 시에 발생하는 회생전력을 재사용할 수 있는 부산도시철도의 더블 컨버터 직류 변전설비를 제안하며 전차선 직류전압 품질향상을 위해 부산도시철도 더블 컨버터 직류 변전설비에서 발생하는 Converter/Inverter mode 변환 시의 undershoot와 overshoot를 최소화할 수 있는 최적의 사이리스터 점호각을 시뮬레이션을 통하여 제시하였다.

Spice parameter를 이용한 IGBT의 과도응답 예측 (Prediction of the transient response of the IGBT using the Spice parameter)

  • 이효정;홍신남
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.815-818
    • /
    • 1998
  • The Insulated Gate Bipolar Transistor has the characteristics of MOSFET and BJT. The characteristics of proposed device exhibit high speed switching, the voltage controlled property, and the low ON resistance. This hybrid device has been used and developed continuously in the power electronic engineering field. We can simulate many IGBT circuits, such as the motor drive circuit, the switching circuits etc, with PSpice. However, some problems in PSpice is that the IGBT is old-fashioned and is very difficult to get it. In this paper, the IGBT in PSpice is considered as the basic structure. We changed the valuse of base width, gate-drain overlaping area, device area, and doping concentration, then calculated MOS transconductance, ambipolar recombination lifetime etc. Using this resultant parameter, we could predict the transient response characteristicsof IGBT, for examplex, voltage overshoot, the rising curve of voltage, and the falling curve of current.

  • PDF

Internal Model Control of UPS Inverter using Resonance Model

  • Park J. H.;Kim D. W.;Kim J. K.;Lee H. W.;Noh T. K.;Woo J. I.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.184-188
    • /
    • 2001
  • In this paper, a new fully digital control method for single-phase UPS inverter, which is based on the double control loop such as the outer voltage control loop and inner current control loop, is proposed. The inner current control loop is designed and implemented in the form of internal model control and takes the presence of computational time-delay into account. Therefore, this method provides an overshoot-free reference-to-output response. In the proposed scheme, the outer voltage control loop employing P controller with resonance model implemented by a DSP is introduced. The proposed resonance model has an infinite gain at resonant frequency, and it exhibits a function similar to an integrator for AC component. Thus the outer voltage control loop causes no steady state error as regard to both magnitude and phase. The effectiveness of the proposed control system has been demonstrated by the simulation and experimental results respectively.

  • PDF

Minimization of Rising and Falling Times of A Boost Type Converter Output Voltage in Pulsed Mode Operation

  • Nho Eui-Cheol;Kim In-Dong;Joe Cheol-Je;Chun Tae-Won;Kim Heung-Geun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.286-290
    • /
    • 2001
  • This paper describes an improved short-circuit protection method with a boost type rectifier using a multilevel ac/dc power converter. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. Once the fault has been cleared the dc power is reapplied to the load. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the dc voltage because the dc output capacitors hold undischarged state. The converter, which employs the proposed method, has the characteristics of a simplified structure, reduced cost, weight, and volume compared with a conventional power supply, which has frequent output short-circuits. Experimental results are presented to verify the usefulness of the proposed converter.

  • PDF

Modified 멀티레벨 컨버터 기반 펄스모드 동작 직류전원장치 (A Pulsed Mode Operating DC Power Supply Based on Modified Multilevel Converter)

  • 안종수;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.264-268
    • /
    • 2003
  • This paper describes a high voltage high power DC power supply which has the ability of pulsed mode operation. The power supply Is constructed with several series connected power converters based on modified multilevel converters. The modified multilevel converters are suitable for the protection of frequent output short-circuit. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the do voltage because the dc output capacitors keep undischarged state. Analysis, simulations, and experiments are carried out to Investigate the operation and usefulness of the proposed scheme.

  • PDF

능동 클램프형 전류형 단상 풀브리지 DC-DC 컨버터의 동작 해석 (Analysis of Current Fed Full Bridge DC-DC Converter with Active Clamp)

  • 차한주;최순호;안치형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.205-207
    • /
    • 2007
  • Isolated Current fed full-bridge converter with active clamp is analyzed in this paper. An active clamp branch is used for limiting the voltage overshoot in the bridge switches and rectifier diodes. Zero voltage switching(ZVS) is also realized by using the energy stored in the transformer leakage inductance. To analyze the converter, 6 modes of operation are introduced and investigated. For each of the modes, voltage and current equations are derived together with corresponding equivalent circuits. 200W prototype dc-dc converter is assembled and verifies the effectiveness of the analysis and simulation.

  • PDF

동기발전기 여자시스템 제어를 위한 직접순시전압제어기법 (Direct Instantaneous Voltage Control Strategy for Synchronous Generator Excitation System)

  • 이상훈;김태형;이동희;안진우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.218-223
    • /
    • 2007
  • This paper presents a simple, robust excitation control system for synchronous generator using direct instantaneous voltage control(DIVC) method. The proposed DIVC excitation system can operate as high dynamics of power conversion system without any control gains such as Pill controller. And the transient overshoot of generator voltage can be suppressed with a simple time constant. For the continuous control of excitation system, the fast IGBT inverter system is used in this paper for exciter's field control. The proposed control scheme is verified by the computer simulations and experimental results in the prototype generation system.

  • PDF

고분자 전해질형 연료전지 자동차의 급기 시스템의 동적 모델링 및 분석 (Dyamic Modeling and Analysis of Air Supply System for Vehicular PEM Fuel Cell)

  • 장현탁
    • 한국수소및신에너지학회논문집
    • /
    • 제15권3호
    • /
    • pp.175-186
    • /
    • 2004
  • In this paper, we developed the dynamic model of a fuel cell system suitable for controller design and system operation. The transient phenomena captured in the model include the flow characteristics and inertia dynamics of the compressor, the intake manifold filling dynamics, oxygen partial pressures and membrane humidity on the fuel cell voltage. In the simulations, we paid attention to the transient behavior of stack voltage and compressor pressure, stoichiometric ratio. Simulation results are presented to demonstrate the model capability. For load current following, stack voltage dynamic characteristics are plotted to understand the Electro-chemistry involved with the fuel cell system. Compressor pressure and stoichiometric ratio are strongly coupled, and independent parameters may interfere with each other, dynamic response, undershoot and overshoot.

Low-ripple coarse-fine digital low-dropout regulator without ringing in the transient state

  • Woo, Ki-Chan;Yang, Byung-Do
    • ETRI Journal
    • /
    • 제42권5호
    • /
    • pp.790-798
    • /
    • 2020
  • Herein, a low-ripple coarse-fine digital low-dropout regulator (D-LDO) without ringing in the transient state is proposed. Conventional D-LDO suffers from a ringing problem when settling the output voltage at a large load transition, which increases the settling time. The proposed D-LDO removes the ringing and reduces the settling time using an auxiliary power stage which adjusts its output current to a load current in the transient state. It also achieves a low output ripple voltage using a comparator with a complete comparison signal. The proposed D-LDO was fabricated using a 65-nm CMOS process with an area of 0.0056 μ㎡. The undershoot and overshoot were 47 mV and 23 mV, respectively, when the load current was changed from 10 mA to 100 mA within an edge time of 20 ns. The settling time decreased from 2.1 ㎲ to 130 ns and the ripple voltage was 3 mV with a quiescent current of 75 ㎂.