• Title/Summary/Keyword: Overload Failure

Search Result 87, Processing Time 0.027 seconds

A Study on Auxiliary Control Safety Apparatus for RCD Trip on Electric Arc and Spark Disasters - Using by Power Semiconductor Switching Device - (아크 및 스파크 재해에 대한 누전차단기 트립을 위한 보조제어 전기안전장치에 관한 연구 - 전력용 반도체 스위칭 소자 적용 및 응용 -)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.71-76
    • /
    • 2006
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young;Kim, Hyo-Jin;Baek, Seong-Hyun;Choi, Byung-Seub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

Scrophulariae Radix Aqueous Extracts Ameliorate the Pressure Overloaded Heart Failure by Transverse Aortic Constriction in Mice

  • Woo, Seong-jin;Baek, Kyung-min;Jang, Woo-seok
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.624-636
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the cardioprotective effect of the potent antioxidant properties of Scrophulariae Radix (SR) aqueous extracts by examining pressure overload (PO) heart failure (HF) induced by transverse aortic constriction (TAC) of C57BL/6 mice. Methods: SR (500, 250, 125 mg/kg) and resveratrol (10 mg/kg) were administered orally once a day for 14 days, after the TAC operation. Changes in mortality, the body and heart weights, histopathology of the heart, and antioxidant defense system of the heart were analyzed. Results: After the TAC operation, increases were observed in mortality, heart weights, left ventricular hypertrophy, and lytic and focal fibrotic histological change, and destruction of the heart antioxidant defense system. However, the HF signs showed dose-dependent inhibition following 14 days of continuous oral treatment with SR. A SR dose of 125 mg/kg gave a similar inhibition to that obtained with resveratrol at 10 mg/kg. Conclusions: Oral administration of SR beneficially improves PO-induced HF following TAC surgery by increasing the activity of the heart antioxidant defense system. The overall effect of SR at 125 mg/kg is similar to the effect of resveratrol at 10 mg/kg. However, more detailed mechanistic studies should be performed by screening of the biologically active compounds in SR.

Development of Smart-phone based Thermal Imaging Diagnostic System for Monitoring Disc Pads of Crane (크레인 디스크 패드 모니터링을 위한 스마트폰 기반의 열영상 진단 시스템 개발)

  • Oh, Yeon-Jae;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.12
    • /
    • pp.1397-1404
    • /
    • 2014
  • Grab cranes are used for multi-purpose when the sand and soil are deposited into harbor wharf or the undersea construction is performed. Among the components of crane grab, the wire drum and disc brake pad are key expendables and have disadvantages that lot of heat is generated and very expensive when replacing them. In this study, the thermal image analysis for the disc brake, which works with wire drum of the crane is suggested. The suggested system performs the pad thermal diagnosis through the thermal image using the characteristics that the disc and pad surface temperatures are distributed abnormally before the brake failure and the disc pad damage. Therefore, the damage by the failure can be prevented by discovering the abnormality of the machine parts before failure and the life cycle of the pad and the cost can be extended and saved by operating the crane performing constant checkup for the overload.

Fracture Analysis of Implant Components using Scanning Electron Microscope - Part I : Implant Fixture (임플란트 구성요소의 파절면에 관한 주사전자현미경적 연구 - Part I: 임플란트 고정체)

  • Lim, Kwang-Gil;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.297-309
    • /
    • 2010
  • The objective of the present study was to perform a fracture analysis on fractured implant fixture after use in vivo and make clear the cause & mechanisms of failure. In case of fatigue fracture, the fractured surface represents fatigue striation. Fatigue striation indicate the progression of the crack front under cyclic loading, are characteristic of stage 2 crack growth. The site of crack initiation and stage 1 crack growth were not easily identified in any of the failure, presumably because of the complex microstructural features of the polycrystalline sample. In case of fractured by overload, dimpled or cleavage surface were observed. Using the interpretation of characteristic markings(ratchet mark, fatigue striation, dimple, cleavage et al) in fracture surfaces, failure events containing the crack origin, crack propagation, material deficiency could be understand.

Cardioprotective Effects of Salvia Miltiorrhiza Radix on the Pressure Overloaded Heart Failure Model by Transverse Aortic Constriction-induced Mice

  • Kim, Sae-Won;Jang, Woo-Seok;Baek, Kyung-Min
    • The Journal of Korean Medicine
    • /
    • v.37 no.2
    • /
    • pp.23-35
    • /
    • 2016
  • Objectives: The objective of this study is to demonstrate the cardioprotective effects of Salvia Miltiorrhiza Radix (SMR) on the pressure overload (PO)-induced heart failure (HF) by transverse aortic constriction (TAC) in C57BL/6 mice through possible antioxidant effects. Methods: The mortality, body and heart weights, antioxidant defense system of the heart and histopathology of heart were analyzed. The obtained results were compared with resveratrol, in which potent cardioprotective effects on TAC mice model were already proved at a dose level of 10 mg/kg by antioxidant effects, as reference in this experiment. Results: Significant increases of mortalities, heart weights, and hypertrophic, lytic and focal fibrotic histological changes in the left ventricles were found with defects of heart antioxidant defense systems - the increases of heart cortex MDA contents, decreases of GSH contents, SOD and CAT activities in TAC control mice as compared with sham vehicle control mice, respectively. However, these HF signs induced by TAC surgery through PO and destroys heart antioxidant defense systems were significantly and dose-dependently inhibited by 14 days continuous oral treatment of SMR 500, 250 and 125 mg/kg, similar to those of resveratrol 10 mg/kg in SMR 125 mg/kg. Conclusions: The results obtained in this study propose that oral administration of SMR potently alleviates PO-induced HF by TAC, through augmentation of heart antioxidant defense system.

Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm (펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.111-116
    • /
    • 2022
  • The causes of motor burnout include overload, phase loss, restraint, interlayer short circuit, winding ground fault, instantaneous overvoltage, and the rotor contacting the stator, leading to insulation breakdown, leading to breakdown or electrical accidents. Therefore, equipment failure causes not only loss due to cost required for equipment maintenance/repair, but also huge economic loss due to productivity decrease due to process stop because the process itself including the motor is stopped. The current level of technology for diagnosing motor failures uses vibration, heat, and power analysis methods, but there is a limit to analyzing the problems only after a considerable amount of time has passed according to the failure. Therefore, in this paper, a device and algorithm for measuring insulation resistance using DC AMP signal was applied to an industrial motor to solve this problem. And by following the insulation resistance state value, we propose a diagnosis of deterioration and failure of the motor that cannot be solved by the existing method.

A Study for Examples of Fire including with Combustible Substance and electrical overload in Automotive Inside Room (자동차 실내 인화성물질과 전기과부하에 의한 화재관련 사례 연구)

  • Han, Jae Oh;Ham, Sung Hoon;Lim, Ha Young;Lee, Il Kwon
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.38-43
    • /
    • 2014
  • This paper is to analyze and study the failure examples of fire by inflammables and electric contact faulty in interior of vehicle. The first example, the driver used to air freshener that remove the air conditioner bad smell. He get out of a car. And then, he put it on the crash pad. Before long, a fire breaks out because of explosion solar radiation. The second example, the driver used in room of a car. It certified the fire by disconnection phenomenon happened the electric overload. The third example, the driver install the heat rays to warm his body, In the initial stages, it didn't seek the dangerous of fire during using a car to 5,000km. This heat rays become to down durability so that produced the electric overload in an instant. The fourth example, after the man smoked the cigarette on riding with rear seat, he put it on seat in vehicle no extinguishing the burning cigarette. It knew the fact that burnt to ashes a car by on well combustible paper. Thus, the driver must consider a countermeasure for minimize the fire production when he use the inflammable and install adding electric system.

The Role of Plasma B-type Natriuretic Peptide Measurements in the Differential Diagnosis of Acute Dyspnea (급성호흡곤란의 감별진단에서 혈장 B-type Natriuretic Peptide의 역할)

  • Moon, Ji Yong;Bae, Joong Ho;Kim, Tae Hyung;Sohn, Jang Won;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.656-663
    • /
    • 2005
  • Background : The B-type natriuretic peptide (BNP) is a cardiac neurohormone that is specifically secreted from the ventricles in response to volume expansion and a pressure overload. Differentiating congestive heart failure from the pulmonary causes of dyspnea is very important for patients presenting with acute dyspnea. Methods : A retrospective study was carried out on 261 patients who were admitted to the emergency department of Hanyang University Hospital due to acute dyspnea from March to July 2004. The serum BNP levels of the patients were measured using the ELISA method. Results : The BNP levels were 382, 111-1140 pg/ml (median, interquartile range) in the heart failure group (n=119) and 29, 7-81 pg/ml in the non-heart failure group (n=142). The BNP levels according to the subgroups of heart failure were 820, 354-1620 pg/ml, 1650, 239-1990 pg/ml, and 378, 106-1120 pg/ml for the chronic obstructive pulmonary disease (COPD) with combined left heart failure (n=5), cor pulmonale (n=3), and left heart failure groups (n=111), respectively. The BNP levels according to the subgroups of non-heart failure were 39, 21-101 pg/ml, 59, 10-129 pg/ml, and 15, 6-47 pg/ml for the COPD (n=20), other pulmonary diseases (n=56), and other causes groups (n=66), respectively. The BNP levels were significantly different according to the underlying etiology (p<0.001), and were significantly higher in the COPD patients with left heart failure than in those without (p=0.002). When the patients with no cardiovascular risk factor such as diabetes mellitus, hypertension, smoking or renal failure were analyzed, the BNP levels were also significantly higher in the patients with heart failure than in those without(p<0.001). When 133 pg/ml was designated as the BNP cut-off level the sensitivity for predicting heart failure was 73 percent and the specificity was 87 percent. Conclusion : BNP measurements are useful for determining the presence of heart failure in the patients presenting with acute dyspnea. The possibility of heart failure must be seriously considered in patients with high BNP levels even when they have a pre-existing pulmonary disease such as COPD or no risk factors for heart failure.

The Application of B-Type Natriuretic Peptide Level of the Dyspneic Patients : Differentiation Between Cor Pulmonale and Left Ventricular Dysfunction (호흡곤란을 주소로 내원한 환자에서 혈청 B-type Natriuretic Peptide 검사의 유용성 : 폐성심과 좌심부전의 감별에 대하여)

  • Park, Hong-Hoon;Kim, Sehyun;Choi, Jeongeun;Kim, Kang-Ho;Cheon, Seok-Cheol;Lee, Jihyun;Lee, Yong-Gu;Kim, In-Jae;Cha, Dong-Hoon;Hong, Sang-Bum;Lee, Ji-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.3
    • /
    • pp.320-329
    • /
    • 2003
  • Background : The serum B-type natriuretic peptide (BNP) is released from the ventricles as a response to volume or pressure overload of the ventricles. A few studies have reported that the BNP measurements are useful in differentiating between heart failure and pulmonary causes in patients who visited the emergency department with dyspnea as the chief complaint. It is difficult to differentiate a right heart failure from a left heart failure in the emergency room. However, there is no report on the application of a BNP assay to differentiate in right heart failure from left heart failure. In this study, the BNP levels were measured from dyspneic patients in the emergency department to determine whether or not the BNP level would be useful in differentiating the cause of the dyspnea from right ventricular failure and left ventricular failure. Method : 89 patients who visited emergency department of the Bundang Cha Hospital with dyspnea from June 2002 to March 2003 were selected. The 29 patients from the outpatient clinics and inpatients were randomly selected as the control. Results : The BNP levels of patients in the left heart failure group were significantly different from that of the patients in the right heart failure group ($682{\pm}314$ pg/mL vs. $149{\pm}94$ pg/mL, p=0.000). When the BNP cut-off level was designated as 219 pg/mL using the receiver operating characteristic curve, the sensitivity was 94.3%, and specificity was 92.9%. In addition, the positive predictive value was 97% and the negative predictive value was 86.7% in differentiating right heart failure from left heart failure. Conclusion : Measurements of the serum BNP levels is an accurate and rapid method that can aid in distinguishing between right heart failure and left heart failure.