• 제목/요약/키워드: Overhead line

Search Result 455, Processing Time 0.034 seconds

Development of an Image Processing Based Method for Dynamic Stagger Extraction of Pantograph-Overhead Contact Line System (영상처리를 통한 팬터그래프-전차선로 동편위 추출 기술 개발)

  • Cho, Chul-Jin;Cho, Yong-Hyeon;Kwon, Sam-Young;Lee, Ki-Won;Jang, Sa-Sool;Ryoo, Hyang-Bok
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1336-1341
    • /
    • 2011
  • The pantograph-overhead contact line system is an interface that supplies power to high-speed trains used in many countries including Korea. Due to the fact that power is supplied through direct contact between contact wires and contact strips, wear may occur, increasing the possibility of accidents over periods of time. Therefore, there is a need to establish methods of effectively extracting safety related parameters. In this paper, an image processing based method that calculates and draws graphs of a pantograph's dynamic stagger is proposed. To assess reliability, the results were compared with data collected from conventional maintenance vehicles.

  • PDF

Technique of Tension Length Calculation for 350km/h High Speed Catenary System (최고운행속도 350km/h급 전차선로 장력구간길이 계산 기법)

  • Chang, Sang-Hoon;Lee, Ki-Won;Kwon, Sam-Young;Park, Jae-Woong
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.932-939
    • /
    • 2011
  • This paper deal with technique of tension length calculation for 350km/h high speed catenary system. Tension length affects in facility investment. Possibility of overlap increasing a tension length and the equipment investor decreases in order to decrease. Considers the parameter which specifies and the grudge which is possible long the fact that decides a tension length is the aim which is important plans overhead contact line. The element which decides a tension length with next following; (i) Operating range of tension device, (ii) Change of the horizontal tension which affects possibility of the effect which operates to the line and span, (iii) Tension of wire material the tensile force which is relation, (iv) Wire thermal expantion which relates with a standard temperature, (v) Curve radius, (vi) Wind velocity, (vii) Thermal range of overhead contact wire and mechanical design of tension mechanism etc.

  • PDF

Calculations on the Reduction Rate of Ground Level Magnetic Fields due to Varying Configurations of Overhead Transmission Line (가공 송전선 형상변화에 따른 지표면 자계저감율 계산)

  • Min, Suk-Won;Kim, Eung-Sik;Park, Jun-Hyeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2027-2034
    • /
    • 2008
  • There are concerns on possible health effects from exposure to electromagnetic fields. One reflection of this concerns is the considerable controversy, delay, and cost increases involved in the construction of power lines and facilities. To cope with such challenges, in this paper we investigated magnetic fields reduction techniques such as general compaction, in' span compaction, cruciform, vertical, 3 way splits phase, and 4way splits phase. As results, we found general compaction and 4 way splits phase could reduce magnetic fields up to 90%, while cruciform, vertical, and 3 way splits phase gave lower reduction rates of 30% because these configurations were similar to a current type of low reactance arrangement. We also knew 1 spacer in span compaction was appropriate in Korea in view of effectiveness and economy.

The Study on the Impulse Characteristic of Secondary Arresters in Power Distribution System (가공 배전선로 중성선과 가공지선 겸용시의 임펄스 특성 연구)

  • Kang, Moon-Ho;Kim, Dong-Myeong;Song, Il-Keun;Chun, Sung-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.297-299
    • /
    • 2004
  • In multi-ground distribution system, overhead ground wire and neutral wire are parallel connected to offer the electrical power energy and protect damage of lightning strokes. Therefore a case where the two wires become single wire, the power company can get the benefit such as installation cost saving and line fault protection by simplify of distribution line. In this paper we describe the result of impulse test in both system ; one is the present power system the other is unified power system parallel connected overhead ground wire and neutral wire. As a result of this impulse test, the present power system get lower impulse voltage than the unified power system.

  • PDF

Degradation Diagnosis of Overhead Power Lines Using Eddy Current Technology (와전류 기법을 이용한 가공전력선 열화 진단)

  • Kim, Chng-Hyeok;Kim, Tag-Yong;Oh, Yong-Cheul;Choi, Woon-Sik;Jo, Choon-Nam
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.5
    • /
    • pp.322-327
    • /
    • 2014
  • Internal corrosion of the distribution line can be detected in order to develop techniques of non-destructive inspection methods that operate only on the metal track eddy current diagnosis is possible by applying the technique investigated. Sensor for the production of a finite element method modeled by using an eddy current sensor, a distribution line by using an accelerated aging samples of sodium hydroxide was prepared. Sheathed cables for internal corrosion studies detected using an eddy current sensor is considered to be possible.

Development of Polymer Bushing for Overhead Line Switch (가공개폐기용 폴리머 부싱 개발)

  • 최경선;주종민;이철호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.787-790
    • /
    • 2001
  • Polymer bushing used for overhead line switch was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage, impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 151-146∼147, 170∼180 of KEPCO. The polymer bushing consists of an internal epoxy bushing and external housing made of EPDM rubber. The rubber housing was molded with mold cone. Therefore, the polymer bushing offers several advantages like light weight, good sealing properties, easy installation and excellent performance in contamination. Electric field analysis was also introduced in order to verify the reliability of the design.

  • PDF

Analysis of Surge Behavior and Protection Method in the Underground Distribution Systems with Branch Lines (분기선로가 포함된 지중배전계통에서 서지특성 해석 및 보호방안에 관한 연구)

  • Lee, Jang-Geun;Lee, Jong-Beom;Lee, Jae-Bong;Kim, Byoung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.148-150
    • /
    • 2006
  • This paper describes the overvoltage at the branch line in underground distribution systems when the direct lightning surge strikes on conductor of overhead line. Distribution systems are very complex because it includes many branch lines, transformers, switches and so on. Therefore model system consists of overhead distribution lines, underground cable include branch lines, lightning source and switches. Analysis are performed using EMTP to understand and evaluate the surge behavior on branch lines considering various conditions in underground distribution systems. Simulation results show overvoltage with location in various cases. It is evaluated that result will be used to establish protection methods in actual underground distribution systems.

  • PDF

Characteristics of Wind Noise from Warning Spheres for Overhead Transmission Line (가공선로 표지용 구의 소음 특성)

  • Chu, Jang-Hee;Shin, Koo-Yong;Lee, Seong-Doo;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.497-499
    • /
    • 2002
  • 가공선로 표지물로 사용되는 구에서 발생하는 소음의 특성을 조사하였다. 현재 한전에서 사용하고 있는 표지용 구의 크기는 직경 62cm이며 두께가 3mm인 합성수지로 만든 반구를 접합부분에 요철형상으로 결합하도록 되어있다. 현장에서 발생하는 소음 스펙트럼을 측정하여, 무향 풍동에서 측정한 구형 셀에서 발생하는 스퍽트럼과 비교하였다. 백색음을 입사하여 구형 셀의 크기에서 발생하는 기본음의 스펙트럼을 조사하였다.

  • PDF

A Low-Power ECC Check Bit Generator Implementation in DRAMs

  • Cha, Sang-Uhn;Lee, Yun-Sang;Yoon, Hong-Il
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.4
    • /
    • pp.252-256
    • /
    • 2006
  • A low-power ECC check bit generator is presented with competent DRAM implementation with minimal speed loss, area overhead and power consumption. The ECC used in the proposed scheme is a variant form of the minimum weight column code. The spatial and temporal correlations of input data are analyzed and the input paths of the check bit generator are ordered for the on-line adaptable power savings up to 24.4% in the benchmarked cases. The chip size overhead is estimated to be under 0.3% for a 80nm 1Gb DRAM implementation.

Assessment of Short-Time Characteristic ACSR-OC Conductor (ACSR-OC 전선의 단시간 특성 평가)

  • Lee, Joong-Kwan;Kim, Dong-Muyng;Yi, Sue-Muk
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1446-1448
    • /
    • 2002
  • The short-time permissible temperature of an overhead distribution line conductor is determined by the softening characteristics of ACSR-OC, ACSR AW/OC 160, typical conductors employed in the overhead distribution line. Transient heat transfer equation and Newton's cooling law were applied to analyze the heating and cooling effects of the insulating conductors, respectively, and the error of co-relation was calibrated after simulating the softening test to assess the short-time characteristic of the insulating conductor. In order to verify the softening characteristic, the conductors were tested with heat cycle. The test was totally carried out 200 cycles, and 1 cycle was to heat and cool at 1.1 times permissible current of the conductor, 1.15 times for 120 minutes, respectively. After heating, the tensile strength and surface of the conductor were observed. In case of ACSR-OC, as the result of 100 hour heating test, the tensile strength of the insulator was 0.8 times the initial value. This is equivalent to the value of the conductors which are used for 10 years at sites.

  • PDF