• 제목/요약/키워드: Overhead ground wire

검색결과 42건 처리시간 0.029초

350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구 (A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line)

  • 이학표;서기범;박재영
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

배전선 1상의 피뢰기 및 가공지선 생략 방안 연구 (A Study on The Scheme for Omission of lightning Arresters on One-Phase and Overhead Ground Wires in the Power Distribution Lines)

  • 정현수;정창호;김진오;송일근;장완성
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.13-20
    • /
    • 2001
  • 본 논문은 배전선에 설치하는 내뢰설비인 가공지선과 피뢰기의 특성과 생략 방안에 대하여 언급하였다. 특히, 피뢰기의 중간 상을 생략하는 방안에 대하여 EMTP 시뮬레이션을 실시하여 생략시 나타날 수 있는 문제점과 생략 방안에 대해 기술하였으며, 가공지선은 지정된 경우에는 생략이 가능하고 피뢰기는 중간 상을 생략시 건전상의 피뢰기 용량을 재검토해야 할 것으로 생각된다.

  • PDF

축소모델을 이용한 22.9kV-Y 배전선로의 유도뢰 분석 (Analysis on Induced Lightning of a 22.9kV-Y Distribution Line Using a Reduced Model)

  • 김점식;김도영;박용범;권신원;길경석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.434-439
    • /
    • 2010
  • This study fabricated a simulation facility which reduced the structure of a current distribution line to 50:1 in order to analyze the induced lightning shielding effect of a 22.9kV-Y distribution line according to ground resistance capacity, grounding locations, etc. When installing an overhead ground wire, the standard for grounding a distribution line with a current of 22.9kV-Y requires that ground resistance in common use with the neutral line be maintained less than $50\Omega$every 200m span. The reduced line for simulation had 7 electric poles and induced lightning was applied to the ground plane 2m apart from the line in a direction perpendicular to it using an impulse generator. If induced voltage occurred in the line and induced current flowed through the line due to the applied current, the induced voltage and current of the 'A' phase were measured respectively using an oscilloscope. When all 7 electric poles were grounded with a ground resistance of less than $50\Omega$ respectively, the combined resistance of the line was $7.4\Omega$. When an average current of 230A was applied, the average induced voltage and current measured were 1,052V and 13.8A, respectively. Under the same conditions, when the number of grounding locations was reduced, the combined resistance as well as induced voltage and current showed a tendency to increase. When all 7 electric poles were grounded with a ground resistance of less than $100\Omega$, the combined resistance of the line was $14.9\Omega$. When an average current of 236A was applied, the average induced voltage and current of the 'A' phase calculated were 1,068V and 15.6A, respectively. That is, in this case, only the combined resistance was greater than when all 7 electrical poles were grounded, and the induced voltage and current were reduced. Therefore, it is thought that even though ground resistance is slightly higher under a construction environment with the same conditions, it is advantageous to ground all electric poles to ensure system safety.

154kV 변전소의 전자계와 유도전압계산 (The calculatation of induced voltages and electromagnetic fields in 154kV sub)

  • 최창혁;한풍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1659-1662
    • /
    • 1998
  • This paper is to analyze electromagnetic fields on a 154kV substation system and induced voltages on the substation fence when the network is operating in a normal condition or a fault condition in which one phase is shorted with the overhead ground wire. Also, changing the scalar potential and electromagnetic fields that are changed in accordance with changing resistivity and permeability of ground are studied. A finding of the study is that the scalar potential and electromagnetic fields are raised near the tower: The values of electric field on the corner of fence and at the edge of the ground grid are higher than other locations.

  • PDF

Evolution Strategy 알고리즘을 이용한 송진선로 주변에서의 최적 자계차폐 위치선정 (Decision of Optimal Magnetic Field Shielding Location around Power System Using Evolution Strategy Algorithm)

  • 최세용;나완수;김동훈;김동수;이준호;박일한;신명철;김병성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권1호
    • /
    • pp.5-14
    • /
    • 2002
  • In this paper, we analyze inductive interference in conductive material around 345 kV power transmission line, and evaluate the effects of mitigation wires. Finite element method (FEM) is used to numerically compute induced eddy currents as well as magnetic fields around powder transmission lines. In the analysis model, geometries and electrical properties of various elements such as power transmission line, buried pipe lines, overhead ground wire, and conducting earth are taken into accounts. The calculation shows that mitigation wire reduces fairly good amount of eddy currents in buried pipe line. To find the optimum magnetic field shielding location of mitigation wire, we applied evolution strategy algorithm, a kind of stochastic approach, to the analysis model. Finally, it was shown that we can find more effective shielding effects with optimum location of one mitigation wire than with arbitrary location of multi-mitigation wires around the buried pipe lines.

축소 모의된 22.9 kV-Y 배전선로의 유도 전압에 대한 신뢰성 검증 (Verification of Reliability by the Induced Voltage of a Downscaled and Simulated 22.9kV-Y Distribution Line)

  • 김점식;최충석
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.26-31
    • /
    • 2015
  • The purpose of this paper is to measure the induced voltage of the downscaled and simulated overhead ground wire of a 22.9kV-Y distribution line. This study performed a test of the downscaled and simulated distribution line according to whether it is grounded or not and the value of the ground resistance. In order to verify the reliability of the data measured by the test, the data was analyzed using the Minitab 17 program. It was found that the induced voltage of the downscaled and simulated distribution line is influenced by the value of the ground resistance. It was also found that the ground resistance obtained at a certain point is closely related to whether electric poles are grounded or not. The analysis results of the measured test data with a statistical method showed that the Anderson Darling (AD) was analyzed to be the smallest as 0.188 when the ground resistance of the electric poles had been maintained at $10{\Omega}$. In addition, the P value analyzed to be 0.894 which is in the proximity of the theoretical value of 1 and verified the reliability of the test data. It could be seen that the data measured by the downscaled simulation test forms a linear graph. It is thought that if a distribution line is installed in the same manner as the downscaled, simulated distribution line, the mean induced voltage will be reduced and reliability will be increased.

2단 장주로 구성된 배전선로의 인접 통신선에 대한 유도전압 계산 (An Induced Voltage Calculation on Telecommunication Line of Two Step Type Pole in Distribution Lines)

  • 김현수;이상봉;김철환;류승헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.148-150
    • /
    • 2007
  • This paper presents a calculation method of an induced voltage on telecommunication lines using primitive impedance matrix. The advantages of the method are using actual neutral current value and not using screening factor for considering the overhead ground wire and neutral wire. To verify the effectiveness and accuracy of the method, case studies are performed with EMTP (Electro-Magnatic Transient Program).

  • PDF

가공지선과 중성선을 겸용하는 실증 배전선로 구축 및 낙뢰 영향 분석 (Substantiation-Distribution line Construction and Analysis of the Lightning Influence of Neutral wire Combined as a Overhead Ground wire)

  • 김점식;김도영;박용범;권신원;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2103-2104
    • /
    • 2011
  • 본 논문에서는 이론적, 실험적 분석의 경험을 토대로 가공지선과 중성선을 겸용하는 실증 배전선로를 구성하고자 한다. 이를 위해 가공지선과 중성선을 겸용하는 선로를 제안하고 실증적 규모에서 가공지선과 중성선을 겸용하는 선로의 효율성을 입증하기 위해 실증 배전선로를 구성하여 운영하였으며, 선로 구조에 따른 낙뢰영향 및 중성선의 설치 위치 변경에 따른 효과를 비교 분석한다. 이에 충북 청원군 형동리 일대에 가공지선과 중성선을 겸용하는 실증 배전선로를 구성하여 운영하였으며 낙뢰카운터기를 설치하여 운영기간 동안 낙뢰 차폐효과를 분석하였다.

  • PDF

병행 배전선로에서의 통신선 유도전압 계산 (Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines)

  • 김현수;이상봉;여상민;김철환;류승헌;김성암;원봉주
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

가공지선 전류 검출 방식의 송전선 사고 및 낙뢰 구간 검출 시스템 개발 (The Development of Fault and Lightning Stroke Section Location System for Overhead Transmission Line)

  • 이창영;김정년;오덕진;하체웅;김동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.584-586
    • /
    • 2004
  • This paper deals with the development of on-line fault and lightning stroke section locating system for branched overhead transmission line. The section locating algorithm of this system i3 by analyzing the distribution pattern of current flowing through the overhead ground wire. It composes of three parts; current sensors, local remote terminal unit(RTU) and analysis program at surveillance tenter. Double Rogowski coil sensor having integrating amplifier was designed as current sensor. In order for current pattern analysis, the transmitted waves from each sensor wert synchronized by GPS tim c clock in RTU. While, lightning stroke location are judged only by polarity information of lightning currents. This design has a benefit in simplicity of signal processing unit of RTU.