• 제목/요약/키워드: Overhead Transmission Conductor

검색결과 77건 처리시간 0.024초

HVDC ${\pm}500kV$ 가공 송전선로의 최적 도체방식 선정을 위한 전기환경특성 평가 (Assessment of the Electrical Environmental Characteristics to Decide Optimal Bundle Type for HVDC ${\pm}500kV$ Overhead Transmission Lines)

  • 주윤노;길경석;양광호;이성두;황기현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권11호
    • /
    • pp.520-526
    • /
    • 2006
  • Corona interferences, such as radio noise, audible noise and television noise, need to be taken into account in the design of HVDC transmission line conductor configuration. Therefore the line designer requires data from which to estimate the corona performance of any set of conductors. To get a sufficiently complete set of design data, it is necessary to examine the corona test of a large number of conductor geometries. This paper presents the results of corona cage test among three types of candidate conductors. It is quite clear from test results that the conductor geometries play an important role in establishing the magnitude of corona noise. Corona noise data from corona cage test are expressed as a statistical distribution of results obtained over long periods of time and various weather conditions. Therefore we can determine an environmentally-friendly conductor bundle for HVDC overhead transmission line. Based on this finding results, various simulations about HVDC line configurations, such as pole space and pole height, will be conducted. And then finally an optimal configuration for HVDC transmission line will be decided.

가공송전선 유도장해 특성을 고려한 최적 상배열 연구 (Study on Optimal Phase Arrangement Considering the Characteristics of Inductive Interference from Overhead Transmission Lines)

  • 강경두;김진규
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.13-18
    • /
    • 2019
  • The domestic overhead transmission lines use a vertical configuration and reverse phase arrangement, but when there is a limitation in steel tower height because the transmission lines pass a height limit zone or special zone, an application of triangular arrangement is necessary, and a study on the optimal phase arrangement to minimize inductive interference for this is necessary. If conductor arrangement are changed, the action of electrostatic induction and electromagnetic induction becomes different from before changes, so the changed conductor arrangement should be reviewed in terms of inductive interference. So this paper presents an optimal phase arrangement to reduce inductive interference by calculating electrostatic induction and electromagnetic induction according to conductor arrangement.

슬리브 시공유형별 기계적 및 열적 가속열화특성 분석 연구

  • 안상현;김병걸;김상수;손홍관;박인표
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.286-286
    • /
    • 2009
  • According to previous report, aged sleeves for old transmission lines have various defect such as biased installation or corrosion of steel sleeve. These defects can cause serious accidents such as rapid increasing of sag or falling out of overhead conductor from sleeves. Moreover, the defects have been limited power capacity of transmission line. This paper study on mechanical and thermal behavior of ACSR $410mm^2$ conductor and sleeve with various defect model. The conductor has been aged artificially for 50 years. The detailed results were presented in the text.

  • PDF

산불이 가공송전선의 온도에 미치는 영향 (The Effect of Forest Fire on Temperature of Overhead Conductor)

  • 김병걸;김상수;전완기;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.523-524
    • /
    • 2007
  • Forest fire can give a serious damage to overhead conductors. Therefore, the definite understanding about aging behavior of burned conductor is very important in maintaining the transmission line safely. It is sure that the temperature of conductor itself will be affected by the distance apart from flame. From this point of a view, we monitored the conductor's temperature with distance from flame. As a result, the conductor's temperature decreased as the flame goes away from the conductor gradually. The temperature of conductor was reached up to 55~65% level of its atmospheric temperature. The detailed results will be presented in the text.

  • PDF

가공송전선의 부하용량과 이도 특성에 관한 실험적 연구 (A An Experimental Study for Load Capacity and Dip Characteristic in Overhead Transmission Lines)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.177-183
    • /
    • 2010
  • Overhead transmission lines in domestic area have been built by several different design standards of dip and ground clearance. This paper describes an experimental study for evaluating load capacity and dip margin in overhead transmission lines. Such design standards for selection of overhead transmission conductors, dip and ground clearance, as well as electrical equipment technical standard are discussed. Based on daily load and weather data, several characteristics such as line utilization factor, load factor, conductor temperature and dip, etc. are analyzed, and compared with the specified levels of design standards. As a result, it is verified that DLR method can be a clue of the solving of the problem, for occurring in old transmission conductors which may be rarely operating below standards.

산불에 의해 가열된 가공송전선의 이도거동 (The SAG Behavior of Overhead Conductor due to Forest Fire)

  • 김병걸;김상수;전완기;한세원;김진한
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.516-517
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about sag behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90%. and then sag of overhead conductor become deteriorated. The detailed results will be given in the text.

  • PDF

이도 측정에 의한 가공송전선 도체의 교체수명 진단 (A Refurbishment life Diagnosis for Overhead Transmission Conductors using Dip Measurement)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.139-146
    • /
    • 2008
  • 가공송전선 도체는 장기간 동안 다양한 환경조건에 노출되어 있으므로 공기오염원이나 열적 이력에 의하여 서서히 열화된다. 노화도체는 전력시스템의 신뢰성과 공중 안전을 감소시키다. 따라서 운용 중인 노화도체의 진단은 적정한 용량으로 전력을 안전하게 공급하거나 노화도체의 교체 또는 새로운 선로의 건설이라는 관점에서 매우 중요한 관심사가 되었다. 본 논문에서는 이도를 측정하여 노화도체의 교체수명을 진단하고 잔존수명을 추정하는 새로운 방법을 제안한다. 도체온도, 도체전류 및 장력 사이의 관계를 해석함으로써 이도가 노화도체의 기계적 인장손실을 정확하게 나타낼 수 있다는 것을 확인하였다. 몇 가지 수치해석결과를 토대로 제안된 방법이 가공도체의 교체수명이나 잔존수명을 진단하는데 효과적으로 사용될 수 있음을 보였다.

산불에 노출된 강심알루미늄연선 송전선 알루미늄 선재의 기계적 및 전기적 특성 거동 (Mechanical and Electrical Properties of Aluminum Wires of ACSR Conductors due to Forest Fire)

  • 이원교;이정원;김병걸
    • 한국전기전자재료학회논문지
    • /
    • 제23권9호
    • /
    • pp.730-735
    • /
    • 2010
  • Forest fire can cause a serious damage to overhead conductors. Therefore, detailed investigation on the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is of critical importance in maintaining transmission line safely. This paper examines the changes of mechanical and electrical properties of flame exposed conductor. Tensile strength (TS) decreased according to increase of forest fire temperature and conductivity changed according to forest fire temperature. Specimens were aluminum conductors of aluminium conductor steel reinforced (ACSR) 410, 240, 480 $mm^2$. In this paper, the electrical and mechanical characteristics of forest fires exposed overhead conductors depending on the diameter of aluminum conductors are presented. It was possible to estimate the degree of deterioration caused by forest fires. The detailed results are given in the paper.

산불과 소화약제에 노출된 가공송전선의 기계적 및 전기적 특성 변화 (The Mechanical and Electrical property changes of Overhead Conductor due to Forest Fire and Agents)

  • 장용호;김병걸;김상수;한세원;김진한
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.459-460
    • /
    • 2008
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very much important to maintain transmission line safely. Oxidation of overhead conductor was increased with temperature and time(maximum time : 30min). Conductivity of Al conductor was decreased by Agents. The detailed will be given in the text.

  • PDF

소화약제 및 산불에 노출된 가공송전선의 전기적, 기계적 거동 변화 (The Mechanical and Electrical behavior Changes of Overhead Conductor due to Forest Fire and Agents)

  • 장용호;김병걸;김상수;한세원;김진한
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.242-247
    • /
    • 2009
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very much important to maintain transmission line safely. Oxidation of overhead conductor was increased with temperature and time(maximum time : 30min). Conductivity of Al conductor was decreased by Agents. The detailed will be given in the text.