Abstract
Conductors in overhead transmission lines are exposed under various environmental conditions for a long period of time, so that they may be slowly degraded due to air pollutant or thermal history. Aged conductors may reduce power system reliability and public safety. Therefore, diagnosis of aged conductors in service becomes more important concerns with respect to keeping power delivery stable with a proper capability, replacing aged conductors, or constructing a new line. In this paper, we posed a new method to diagnose the refurbishment life and estimate the remaining life of aged conductors by measuring dips. As analyzing some relations of conductor temperature, conductor current, and tension load, it could be verified that dip exactly shows mechanical tension loss for aged conductor. Based on several simulation results, it was shown that the proposed method may be effectively used to diagnose the refurbishment life or remaining one of overhead conductors.
Keywords
Overhead Transmission Conductor; Refurbishment Life; Dip Measurement;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. Sutton and K.G. Lewis, "The detection of internal corrosion in steel reinforced aluminum overhead power line conductors", U.K. Corrosion, pp.343-359, 1986
2 가공선 이도 설계기준 - 1211, 한국전력공사, 2003
3 R.L. Jackson, R.R. Gibbon, J.M. Ferguson and K.G. Lewis, "The condition of the supergrid and a strategy for refurbishment", International Conference on Revitalizing Transmission and Distribution Systems, pp. 44-48, 1987
4 Draft standard for calculating the current-temperature relationship for bare overhead conductors, IEEE Standard P738, 1999
5 가공송전선의 전류용량, 일본 전기학회 기술보고 제660호, 1997
6 가공송전선용 전선 선정기준 - 1210, 한국전력공사, 2003
7 M.F. Ishac, I.F. Boulos, A.P. Goel and D.J. Horrocks, "Life extension of an existing transmission line", The Seventh international Conference on Transmission and Distribution Construction and Live Line Maintenance, pp. 17-23, Ohio, 1995
8 D.L. Rudolph, "A systematic approach to the replacement of an aging distribution system", 1997 IEEE Rural Electric Power Conference, A4.1-8, Minneapolis, 1997
9 D.G. Harvard, et. al, "Aged ACSR conductors. I. Testing procedures for conductors and line items", IEEE Transactions on Power Delivery, Vol. 7, No. 2, pp. 581-587, 1992   DOI   ScienceOn
10 J.M. Ferguson, and R.R. Gibbon, "Overhead transmission lines-refurbishment and developments", Power Engineering Journal, Vol. 8, No. 3, pp. 109-118, 1994   DOI   ScienceOn
11 송전운용업무기준, 한국전력공사 송변전처, 1999
12 D.G. Harvard, et. al, "Aged ACSR conductors. II. Prediction of remaining life", IEEE Transactions on Power Delivery, Vol. 7, No. 2, pp. 588-595, 1992   DOI   ScienceOn