• 제목/요약/키워드: Overdenture attachment

검색결과 103건 처리시간 0.019초

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

Locator attachment를 이용한 하악 임플란트 유지 피개의치의 후향적 평가 (Retrospective Evaluation of Implant Retained Overdentures Using Two Implants and Locator Attachments in the Edentulous Mandibles)

  • 이주형;손동석;이청희
    • 구강회복응용과학지
    • /
    • 제29권2호
    • /
    • pp.153-162
    • /
    • 2013
  • 이번 연구는 2개의 임플란트 식립 후 로케이터를 이용한 하악 임플란트 유지 피개의치를 한 20명의 환자를 대상으로 임플란트 생존율, 변연골 흡수량, 보철적 합병증을 알아보았다. 진료 기록부를 조사하고 방사선 사진을 계측하여 후향적 임상연구를 하였으며, 임플란트는 95%의 누적 생존율을 보였고, 평균 94주 후 방사선 사진에서 임플란트는 평균 1.21 mm($SD{\pm}0.20mm$)의 골소실을 보였다. 보철적 합병증으로는 피개의치 파절, 의치상 이장 또는 개상, 메일의 탈락 또는 유지력 감소로 인한 메일 교체 등이 있었다. 그러나 의치상 이장 및 개상, 메일 인써트의 간단한 교체로 인해 장기적으로 임플란트 및 임플란트 유지 피개의치가 환자에게 유지되고 있었다. Locator를 이용한 하악 임플란트 유지 피개의치는 최소침습적인 수술, 간단한 보철 과정 및 수리 과정의 장점으로 인해 장기적으로 안정적인 치료법으로 사료된다.

하악 부분 무치악 환자에서 Milled-bar와 ADD-TOC 부착 장치를 이용한 탈착 가능한 지르코니아 보철물 수복 증례 (Detachable zirconia prosthesis using Milled bar and ADD-TOC attachment in partial edentulous mandible: A case report)

  • 손민성;허중보
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.90-99
    • /
    • 2023
  • 임플란트 피개의치는 골 흡수가 심한 완전 무치악 또는 부분 무치악 환자의 구강 기능 회복을 위한 치료 방법으로 널리 사용되고 있다. Milled bar를 이용한 임플란트 피개의치의 경우 bar가 임플란트 고정체를 연결 고정하므로 기계적으로 유리하며, bar에 추가적으로 부착 장치를 적용하면 임플란트에 가해지는 응력을 분산시킬 수 있다는 이점이 있다. 본 증례에서는 4개의 임플란트를 사용하여 임플란트 피개의치를 사용하던 환자가 의치의 반복적인 파절과 유지력의 약화로 인해 새로운 보철물 제작을 원하여 ADD-TOC 부착 장치가 부착된 milled bar와 탈착 가능한 지르코니아 보철물을 CAD-CAM 방식으로 제작하였고, 이를 통해 기능적, 심미적으로 만족할 만한 결과를 얻었다.

기성품 바 어태치먼트 시스템인 SFI bar를 이용한 피개의치 전악수복 증례 (Full mouth rehabilitation with maxillary implant overdenture using prefabricated bar attachment system: a case report)

  • 신은정;주한성;방몽숙;양홍서;박상원;임현필;윤귀덕
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.331-337
    • /
    • 2014
  • 전통적인 바와 클립 유지형 피개의치의 경우, 인상채득 및 기공과정에서 오차가 생길 수 있어 바가 nonpassive fit하게 제작될 수 있다. 최근에 나온 기성품 바 어태치먼트 시스템인 SFI-Bar (Stress Free on Implant Bar) system (Cendres+Metaux, Biel/Bienne, Switzerland)은 튜브바로 연결하여 조립하는 방식이므로 밀링방식이나 캐스팅방식에서 겪을 수 있는 작업상의 많은 어려움과 긴 작업 시간의 단점을 보완 할 수 있고, 임플란트 주위골에 가해지는 스트레스도 줄여줄 수 있다. 본 증례에서는 골흡수가 심한 상악 무치악 환자에게 최근에 나온 stress free implant bar인 SFI-Bar system을 사용한 피개 의치로 수복하였다. SFI Bar를 이용한 피개의치 제작시 수동적 적합을 얻을 수 있어 임플란트에 스트레스를 덜 가하는 장점을 얻을 수 있을 것으로 생각한다. 추후 정기적인 검사를 통해 장기적인 결과에 대한 평가가 필요하리라 사료된다.

다수치아를 상실한 엇갈린 교합 환자에서 임플란트와 $Locator^{(R)}$ attachment를 이용한 가철성 국소의치 증례 (Removable partial denture restoration using single implant supported with $Locator^{(R)}$ attachment in a crossed occlusion patient: a case report)

  • 신운철;방몽숙;양홍서;박상원;임현필;윤귀덕
    • 대한치과보철학회지
    • /
    • 제51권2호
    • /
    • pp.113-118
    • /
    • 2013
  • 다수 잔존치를 상실한 경우 잔존치간의 관계가 역학적으로 불리한 상황에 놓일 수 있다. 환자가 의치에 관한 거부감이 없을 때, 이러한 경우 피개의치를 고려할 수 있지만, 무치악 부위에 임플란트를 이용함으로써 역학적인 불리함을 극복하고 국소의치의 지지, 안정, 유지를 향상시킬 수 있다. 본 증례는 소수 잔존치간에 엇갈린 교합을 보이는 환자로 상악 치아에 대합되는 하악의 무치악 부위에 단일 임플란트를 식립하고 $Locator^{(R)}$ attachment를 연결하여 상하악 국소의치로 치료하였다. 기존의 기울어진 교합평면을 이상적으로 재설정하여 환자의 심미적 만족도를 향상시켰다. 치료 이후 6개월간의 임상 관찰에서 환자는 심미적, 기능적으로 만족하고 안정적으로 유지되었기에 보고하고자 한다.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study

  • Aroso, Carlos;Silva, Antonio Sergio;Ustrell, Raul;Mendes, Jose Manuel;Braga, Ana Cristina;Berastegui, Esther;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.21-29
    • /
    • 2016
  • This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS. Three commercially available attachments were investigated: $Clix^{(R)}$, Dalbo-$Plus^{(R)}$ and $Locator^{(R)}$. In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and $37^{\circ}C$. The abutments were placed at angulations of $0^{\circ}$, $10^{\circ}$ and $20^{\circ}$. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS. The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation ($F_{(2.48)}=343619$, P<.05) and the type of attachment ($F_{(7.48)}=23.220$, P<.05). CONCLUSION. Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.

임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교 (Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment)

  • 최재원;채성기;허중보
    • 대한치과보철학회지
    • /
    • 제59권2호
    • /
    • pp.173-180
    • /
    • 2021
  • 목적: 본 연구는 반복적인 착탈에 따른 임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장치의 유지력 특성을 평가해보고자 하였다. 재료 및 방법: 본 연구에서는 새롭게 개발된 유지장치(ADD-Lock; AL)와 기존의 상용화된 유지장치(Locator blue; LB)의 두 가지 유지장치를 평가하였다. 두 개의 고정체를 하부 구조물에 평행하게 위치시키고, 각 유지장치의 patrix를 고정체에 연결하였다. 각 유지장치의 matrix는 대합되는 상부 구조물에 위치시키고 고정하였다. Universal testing machine을 이용하여 초기, 100, 250, 500, 1000, 2000, 2500회의 반복적인 착탈 동안에 각 유지장치의 유지력을 측정하였다. 유지장치의 마모 및 변형 정도는 주사전자현미경으로 관찰하였다. Kruskal-Wallis test, Mann-Whitney U test (α = .05), 그리고 wilcoxon signed-rank test (α = .05)를 이용하여 통계분석 실시하였다. 결과: 초기 유지력과 2500회의 반복적인 착탈 후 유지력에서, AL군(15.24 ± 1.46 N, 9.74 ± 1.16 N)은 LB군(43.53 ± 12.39 N, 22.99 ± 4.77 N)보다 유의하게 작은 값을 보였다(P < .05). 또한, 유지력 소실량에 있어서도 AL군(5.50 ± 1.08 N, 36.08%)이 LB군(20.54 ± 11.89 N, 47.19%)에 비해 낮은 값을 보였다(P < .05). 주사전자현미경 분석 결과, AL군은 patrix에서, LB군은 matrix에서 눈에 띄는 마모 및 변형이 관찰되었다. 결론: Locator는 새롭게 개발된 유지장치보다 높은 초기 유지력을 보인 반면 높은 유지력 소실량을 보였다. 한편, 두 가지 부가적인 유지장치는 반복적인 착탈 후에도 충분한 유지력을 가지는 것으로 나타났다.

Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

  • Rinke, Sven;Buergers, Ralf;Ziebolz, Dirk;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.329-337
    • /
    • 2015
  • PURPOSE. This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS. In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS. One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: $5.9{\pm}2.2years$), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION. Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required.

두 종류의 임플란트 시스템을 이용한 하악의 미니-임플란트지지 피개의치 수복 증례 (Mandibular implant supported overdentures with two different mini-implant systems: A case report)

  • 박진홍;이정열;류재준;신상완
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.267-272
    • /
    • 2016
  • 본 증례는 치조골의 흡수가 심한 두 명의 완전무치악 환자에서 서로 다른 임플란트 시스템을 이용한 하악의 미니-임플란트 지지 피개의치에 대한 증례보고이다. 두 환자는 하악 의치의 유지력 부족으로 인한 의치 사용시 불편감 및 동통을 주소로 호소하였다. 각각의 환자는 4개의 미니 임플란트를 이공사이에 판막의 거상없이 식립하였다. 첫번째 증례는 미니볼 어태치먼트와 일체형으로 된 미니-임플란트(Slimline, Dentium, Seoul, Korea)를 식립하고 구강내 직접법으로 어태치먼트를 연결하여 즉시하중을 시행하였다. 두번째 증례는 분리형으로 로케이터 어태치먼트와 연결되는 미니-임플란트(LODI, Zest Anchors, Escondido, CA, USA)를 이용하였으며, 임플란트 식립 8주 후 간접법으로 어태치먼트를 연결하였다. 최종 의치 장착 후 6개월 정기검진까지 미니볼과 로케이터 어태치먼트를 이용한 하악의 미니-임플란트 지지 피개의치 증례에서 환자의 전반적인 만족도가 개선되었으며 주목할 만한 합병증 없이 만족할 만한 임상적 결과를 얻었다. 단 추후 지속적인 유지관리 및 장기적인 평가가 더 필요하리라 사료된다.