• Title/Summary/Keyword: Overcurrent protection

Search Result 65, Processing Time 0.025 seconds

ELECTRICAL FIRE (전기화재)

  • Park, Heon-Sik
    • Fire Protection Technology
    • /
    • s.11
    • /
    • pp.13-22
    • /
    • 1991
  • To understand electrical fire, the cause of it is classified into overcurrent, short circuit, leak, joint, overheat, accumulation of heat, spark, deterioration of insulation, static electricity, and lightning etc. and explained. And then by the precautions to it, proposed to the improvement of electric products, the completeness of safecty management and the use of alarm systems.

  • PDF

Gray Wolf Optimizer for the Optimal Coordination of Directional Overcurrent Relay

  • Kim, Chang-Hwan;Khurshaid, Tahir;Wadood, Abdul;Farkoush, Saeid Gholami;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1043-1051
    • /
    • 2018
  • The coordination of directional overcurrent relay (DOCR) is employed in this work, considering gray wolf optimizer (GWO), a recently designed optimizer that employs the hunting and leadership attitude of gray wolves for searching a global optimum. In power system protection coordination problem, the objective function to be optimized is the sum of operating time of all the main relays. The coordination of directional overcurrent relays is formulated as a linear programming problem. The proposed optimization technique aims to minimize the time dial settings (TDS) of the relays. The calculation of the Time Dial Setting (TDS) setting of the relays is the core of the coordination study. In this article two case studies of IEEE 6-bus system and IEEE 30-bus system are utilized to see the efficiency of this algorithm and the results had been compared with the other algorithms available in the reference and it was observed that the proposed scheme is quite competent for dealing with such problems. From analyzing the obtained results, it has been found that the GWO approach provides the most globally optimum solution at a faster convergence speed. GWO has achieved a lot of relaxation due to its easy implementation, modesty and robustness. MATLAB computer programming has been applied to see the effectiveness of this algorithm.

Optimal Coordination of Overcurrent Relays in the Presence of Distributed Generation Using an Adaptive Method

  • Mohammadi, Reza;Farrokhifar, Meysam;Abyaneh, Hossein Askarian;Khoob, Ehsan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1590-1599
    • /
    • 2016
  • The installation of distributed generation (DG) in the electrical networks has numerous advantages. However, connecting and disconnecting of DGs (CADD) leads to some problems in coordination of protection devices due to the changes in the short circuit levels in the different points of network. In this paper, an adaptive method is proposed based on available setting groups (SG) of relays. Since the number of available SG is less than possible CADD states, a classifying index (CI) is defined to categorize the several states in restricted setting groups. Genetic algorithm (GA) with a suitable objective function (OF) is used as an optimization method for the classification. After grouping, a modified coordination method is applied to achieve optimal coordination for each group. The efficiency of the proposed technique is demonstrated by simulation results.

A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection (비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구)

  • Kim, Kyung-Chul;Kho, Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

A Sensorless PMDC Motor Speed Controller with a Logical Overcurrent Protection

  • Guerreiro, M.G.;Foito, D.;Cordeiro, A.
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2013
  • A method to control the speed or the torque of a permanent-magnet direct current motor is presented. The rotor speed and the external torque estimation are simultaneously provided by appropriate observers. The sensorless control scheme is based on current measurement and switching states of power devices. The observers performances are dependent on the accurate machine parameters knowledge. Sliding mode control approach was adopted for drive control, providing the suitable switching states to the chopper power devices. Despite the predictable chattering, a convenient first order switching function was considered enough to define the sliding surface and to correspond with the desired control specifications and drive performance. The experimental implementation was supported on a single dsPIC and the controller includes a logic overcurrent protection.

An Innovative Fast Relay Coordination Method to Bypass the Time Consumption of Optimization Algorithms in Relay Protection Coordination

  • Kheshti, Mostafa;Kang, Xiaoning;Jiao, Zaibin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.612-620
    • /
    • 2017
  • Relay coordination in power system is a complex problem and so far, meta-heuristic algorithms and other methods as an alternative approach may not properly deal with large scale relay coordination due to their huge time consuming computation. In some cases the relay coordination could be unachievable. As the urgency for a proper approach is essential, in this paper an innovative and simple relay coordination method is introduced that is able to be applied on optimization algorithms for relay protection coordination. The objective function equation of operating time of relays are divided into two separate functions with less constraints. As the analytical results show here, this equivalent method has a remarkable speed with high accuracy to coordinate directional relays. Two distribution systems including directional overcurrent relays are studied in DigSILENT software and the collected data are examined in MATLAB. The relay settings of this method are compared with particle swarm optimization and genetic algorithm. The analytical results show the correctness of this mathematical and practical approach. This fast coordination method has a proper velocity of convergence with low iteration that can be used in large scale systems in practice and also to provide a feasible solution for protection coordination in smart grids as online or offline protection coordination.

Application of Fault Location Method to Improve Protect-ability for Distributed Generations

  • Jang Sung-Il;Lee Duck-Su;Choi Jung-Hwan;Kang Yong-Cheol;Kang Sang-Hee;Kim Kwang-Ho;Park Yong-Up
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.137-144
    • /
    • 2006
  • This paper proposes novel protection schemes for grid-connected distributed generation (DG) units using the fault location algorithm. The grid-connected DG would be influenced by abnormal distribution line conditions. Identification of the fault location for the distribution lines at the relaying point of DG helps solve the problems of the protection relays for DG. The proposed scheme first identifies fault locations using currents and voltages measured at DG and source impedance of distribution networks. Then the actual faulted feeder is identified, applying time-current characteristic curves (TCC) of overcurrent relay (OCR). The method considering the fault location and TCC of OCR might improve the performance of the conventional relays for DG. Test results show that the method prevents the superfluous operations of protection devices by discriminating the faulted feeder, whether it is a distribution line where DG is integrated or out of the line emanated from the substation to which the DGs are connected.

Analysis of Protection Circuits of Overcurent and Overvoltage on Transmission Line Induced by External Electromagnetic Pulse (외부 전자파 펄스에 의해 전송선로에 유기되는 과전류 및 과전압 보호회로의 해석)

  • 하헌태;김세윤;이경재;오명환
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.1
    • /
    • pp.8-14
    • /
    • 1991
  • A new algorithm for calculation of overcurrent and overvoltage at load for parallel two-wire transmission line with nonlinear protection circuits induced by and external electromagnetic pulse is suggested. The rigorous solution is obtained for a particular type of the incident waveform and protection circuit. The validity of our algorithm is checked by comparing numerical results to the analytic solution in the particular case.

  • PDF

The Assessment and Development of Protection Models in HVDC DC side (HVDC시스템의 직류측 보호 모델 개발)

  • Lee, Seong-Doo;Kim, Chan-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1754-1760
    • /
    • 2010
  • The HVDC system consists of ac side and dc side through thyristor valve. ac side protection is similar to conventional ac system protection schemes but dc side protection is different from ac side of HVDC system. AC system don't have controller but HVDC system has controller that controls and protects system from faults and disturbance. This paper show protectional function of HVDC dc side such as asymmetry protection, ac/dc differential protection, dc overvoltage, dc overcurrent protection. Protection models is developed using RTDS software and assessment of protection models is also performed by RTDS system.

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.