• Title/Summary/Keyword: Over-frequency section

Search Result 89, Processing Time 0.025 seconds

Programmed-release intraosseus anesthesia as an alternative to lower alveolar nerve block in lower third molar extraction: a randomized clinical trial

  • Pol, Renato;Ruggiero, Tiziana;Bezzi, Marta;Camisassa, Davide;Carossa, Stefano
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.3
    • /
    • pp.217-226
    • /
    • 2022
  • Background: Intraosseous anesthesia is the process by which an anesthetic solution, after penetration of the cortical bone, is directly injected into the spongiosa of the alveolar bone supporting the tooth. This study aimed to compare the effectiveness of the traditional inferior alveolar nerve block (IANB) and computerized intraosseous anesthesia in the surgical extraction of impacted lower third molars, compare their side effects systemically by monitoring heart rate, and assess patients' a posteriori preference of one technique over the other. Methods: Thirty-nine patients with bilaterally impacted third molars participated in this study. Each patient in the sample was both a case and control, where the conventional technique was randomly assigned to one side (group 1) and the alternative method to the contralateral side (group 2). Results: The traditional technique was faster in execution than anesthesia delivered via electronic syringe, which took 3 min to be administered. However, it was necessary to wait for an average of 6 ± 4 min from the execution to achieve the onset of IANB, while the latency of intraosseous anesthesia was zero. Vincent's sign and lingual nerve anesthesia occurred in 100% of cases in group 1. In group 2, Vincent's sign was recorded in 13% of cases and lingual anesthesia in four cases. The average duration of the perceived anesthetic effect was 192 ± 68 min in group 1 and 127 ± 75 min in group 2 (P < 0.001). The difference between the heart rate of group 1 and group 2 was statistically significant. During infiltration in group 1, heartbeat frequency increased by 5 ± 13 beats per minute, while in group 2, it increased by 22 ± 10 beats per minute (P < 0.001). No postoperative complications were reported for either technique. Patients showed a preference of 67% for the alternative technique and 20% for the traditional, and 13% of patients were indifferent. Conclusion: The results identified intraosseous anesthesia as a valid alternative to conventional anesthesia in impacted lower third molar extraction.

Finite element model updating effect on the structural behavior of long span concrete highway bridges

  • Altunisik, A.C.;Bayraktar, A.
    • Computers and Concrete
    • /
    • v.14 no.6
    • /
    • pp.745-765
    • /
    • 2014
  • In this paper, it is aimed to determine the finite element model updating effects on the structural behavior of long span concrete highway bridges. Birecik Highway Bridge located on the 81stkm of Sanliurfa-Gaziantep state highway over Firat River in Turkey is selected as a case study. The bridge consist of fourteen spans, each of span has a nearly 26m. The total bridge length is 380m and width of bridge is 10m. Firstly, the analytical dynamic characteristics such as natural frequencies and mode shapes are attained from finite element analyses using SAP2000 program. After, experimental dynamic characteristics are specified from field investigations using Operational Modal Analysis method. Enhanced Frequency Domain Decomposition method in the frequency domain is used to extract the dynamic characteristics such as natural frequencies, mode shapes and damping ratios. Analytically and experimentally identified dynamic characteristics are compared with each other and finite element model of the bridge is updated to reduce the differences by changing of some uncertain parameters such as section properties, damages, boundary conditions and material properties. At the end of the study, structural performance of the highway bridge is determined under dead load, live load, and dynamic loads before and after model updating to specify the updating effect. Displacements, internal forces and stresses are used as comparison parameters. From the study, it is seen that the ambient vibration measurements are enough to identify the most significant modes of long span highway bridges. Maximum differences between the natural frequencies are reduced averagely from %46.7 to %2.39 by model updating. A good harmony is found between mode shapes after finite element model updating. It is demonstrated that finite element model updating has an important effect on the structural performance of the arch type long span highway bridge. Maximum displacements, shear forces, bending moments and compressive stresses are reduced %28.6, %21.0, %19.22, and %33.3-20.0, respectively.

A Synoptic Climatological Study on the Distribution of Winter Precipitation in South Korea (韓國의 冬季 降水 分布에 關한 綜觀氣候學的 硏究)

  • Park, Byong-Ik;Yoon, Suk-Eun
    • Journal of the Korean Geographical Society
    • /
    • v.32 no.1
    • /
    • pp.31-46
    • /
    • 1997
  • The purposes of this paper are to classify the spatial distribution types of precipitation by making daily isohyetal maps based on the winter daily precipitation and to analyse both the distributional characteristics of precipitation during the winter in South Korea and the synoptic characteristics related to them. Also, the correspondence between the spatial distribution types of precipitation and the synoptic characteristics occuring among them is examined with regards to pressure patterns and then precipitation distribution types. In addition, the characteristics of the pressure fields and temperature fields in 850hPa, 700hPa, and 500hPa level were analysed to find out the difference between the Ullung-do type and the Ullung-do${\cdot}$Honam type, which have similar characteristics on the surface weather map. As a result, the Ullung-do area showed a high frequency of occurrence regardless of precipitation classes, the East Coast area revealed a higher frequency of occurrence in over the 5mm section, while the Honam area had high frequency of occurrence in the 1~5mm section. There are twelve distribution types of precipitation during the winter. These distribution types show clear changes according to the season. The difference in precipitation distribution between the Ullung-do type and the Ullung-do${\cdot}$Honam type has a close relationship with the aspect of the upper cold air advection rather than the direction and the speed of the wind.

  • PDF

Characteristics of Static Loading and Dynamic Loading Tests for Bridge Capability (교량 내하력 평가를 위한 정적재하시험 및 동적재하시험 특성)

  • Lee, Sang Hun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.638-649
    • /
    • 2020
  • Purpose: The objective of this study is to evaluate the load carrying capacity of a target bridge structure based on the simple slab bridge of concrete over 20 years of public service. Method: By performing static loading test and dynamic loading test, the displacement, strain, impact factor, and natural frequency values were measured and evaluated through analysis method. Result: The main results of this study are as follows. First, the maximum displacement and maximum strain of S1 were assessed at 2.917 mm and 44.720 𝜇ε( tensile) and -13.760 𝜇ε(compression), respectively, with S2 maximum displacement and maximum strain being 2.100 mm and 4.870 𝜇ε(tensile), respectively. Second, the maximum measured impact factor was 0.191 in section S1 A-A, and the maximum measured impact factor was 0.155 in section S2 C-C. Third, the natural frequency was assessed at 6.086 Hz, and the measurement was found to be within the range of 6.152 Hz to 6.738 Hz. Conclusion: The tested bridge may be evaluated to show good behavior and characteristics for the design load.

Effect of trailing-edge modification over aerodynamic characteristics of NACA 0020 airfoil

  • Ethiraj, Livya;Pillai, Subramania Nadaraja
    • Wind and Structures
    • /
    • v.33 no.6
    • /
    • pp.463-470
    • /
    • 2021
  • This study investigates the aerodynamic characteristics of NACA series airfoil by altering the trailing edge in the form of extended and serrated sections. This contemporary advent examined NACA 0020 airfoil experimentally at the angle of attack ranging from 0° to 45° and for the Reynolds number of 2.46 × 105. To figure out the flow behaviour, the standard average pressure distribution over the airfoil surface is estimated with 50 pressure taps. The time series surface pressure is recorded for 700 Hz of sampling frequency. The extended trailing edge of 0.1 c, 0.2 c and 0.3 c are attached to the base airfoil. Further, the triangular serration is introduced with the base length of 2 cm, 4 cm and 6 cm. Each base length with three different amplitudes of 0.1 c, 0.2 c and 0.3 c were designed and equipped with the baseline case at the trailing edge and tested. The aerodynamic force coefficient, as well as pressure coefficient are presented. The obtained data advises that modification in the trailing edge will reflect the aerodynamic characteristics and the flow behaviour over the section of a wing. Resultantly, the extended trailing edge as a thin elongated surface attached to a base airfoil without revising the main airfoil favors good lift increment. The serrated trailing edge acts as a flow control device by altering the flow pattern results to delay the stall phenomenon. Besides it, improves lift co-efficient with less amount of additional drag. This extended and serrated trailing edge approach can support for designing the future smart airfoil.

Effects of Adjacent Channel Leakage on an Energy Detection Based Spectrum Sensing (인접 채널 누설이 에너지 검파 기반 스펙트럼 센싱에 미치는 영향)

  • Lim, Chang Heon;Kim, Hyung Jung;Kim, Chang Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.542-547
    • /
    • 2014
  • When a primary user transmits over some frequency band assigned to it, most of its transmission power tends to be concentrated in the band but a small portion of it spreads into the adjacent bands. Thus the false alarm probability for the adjacent bands can be higher than expected, even though no primary users are active in the bands. A previous work evaluated the effects of the adjacent channel leakage on the performance of an energy detection based spectrum sensing but it did not take into account the fading phenomenon. In this paper, we analyze the effects of the adjacent channel leakage on an energy detection based spectrum sensing scheme in terms of detection probability and false alarm probability in a fading environment.

Vibration Characteristics of Tapered Piles Embedded in an Elastic Medium (탄성매체에 근입된 변단면 말뚝의 진동 특성)

  • Oh, Sang-Jin;Kang, Hee-Jong;Lee, Jae-Young;Park, Kwang-Kyou;Mo, Jeong-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.832-835
    • /
    • 2005
  • The free vibration of tapered piles embedded in soil is investigated. The pile model is based on the Bernoulli-Euler beam theory and the soil is idealized as a Winkler model for mathematical simplicity. The governing differential equations for the free vibrations of such members are solved numerically. The square tapered piles with one free and the other hinged end with rotational spring are applied in numerical examples. The lowest two natural frequencies are obtained over a range of non-dimensional system parameters: the rotational spring parameter, the embedded ratio, the foundation parameter, the width ratio of the contact area and the section ratio.

  • PDF

A Study on the Cross Section Insurance to Provide for the Extraordinary Flood for the Reservoir of the Temporary Division Tunnel (가배수 터널을 이용한 이상홍수 대비 단면확보에 관한 연구)

  • Baek, Won-Hyun;Park, Ki-Bum;Jee, Hong-Kee
    • Journal of Environmental Science International
    • /
    • v.17 no.7
    • /
    • pp.733-741
    • /
    • 2008
  • The object of this study is the safety insurance of the dam to provide for the extraordinary flood. The safety insurance of the reservoir was taken by the preparatory discharge using the temporary division tunnel used during the reservoir construction. In this study, the Sungju reservoir was simulated. The existing discharge facilities of the intake tower of the Sungju reservoir could nat have influence on the flood control. When the Sungju reservoir operated to begin preparatory discharge for 48 hrs by the temporary diversion tunnel that have discharge of an 20-years frequency, the water level was lowered about 20 cm. When the Sungju reservoir operated to begin the continuous discharge after the preparatory discharge, the water level was lowered over 1m but the downstream at risk was caused by the resulted. If it is possible to operate to begin the preparatory discharge of the reservoir for 24 hrs by the temporary diversion tunnel, that will improve the flood control faculty of the reservoir without other hydraulic structure and safety of the Sungju reservoir will be higher.

Space Service Volume Augmented with Korean Positioning System at Geosynchronous Orbit

  • Kim, Gimin;Park, Chandeok;Lim, Deok Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.4
    • /
    • pp.327-336
    • /
    • 2020
  • This study presents signal availability of inter-operable global navigation satellite system (multi-GNSS) combined with future Korean Positioning System (KPS), specifically at geosynchronous orbit (GSO). The orbit of KPS, which is currently under conceptual feasibility study, is first introduced, and the grid points for evaluating space service volume (SSV) at GSO are generated. The signal observabilities are evaluated geometrically between those grid points and KPS/GNSS satellites. Then, analyzed are the visibility averaged over time/space and outage time to not access one or four signals. The reduction of maximum outage time induced by KPS are presented with different maximum off-boresight angles depending on L1/E1/B1 and L5/L3/E5a/B2 frequencies. Our numerical analysis shows that the SSV of multi-GNSS combined with KPS provides up to 7 additional signals and could provide continuous observation time (zero outage time) of more than four GNSS or KPS signals for 3.20-14.83% of SSV grid points at GSO. Especially at GSO above North/South America and Atlantic region, the introduction of KPS reduces the outage duration by up to 63 minutes with L1/E1/B1 frequency.

Dynamic Characteristics of Railway Plate Girder Bridges with Increase of Diesel Locomotive Speed (철도차량의 증속에 따른 판형교의 진동특성)

  • Cho, Eun Sang;Kim, Hyun Min;Hwang, Won Sup;Oh, Ji Taek
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.6
    • /
    • pp.769-782
    • /
    • 2006
  • As the ambient vibration test (AVT) of railway bridges has a limited range of speed, it has a limitation in examining the dynamic behavior of bridges accordingto speed. Thus, in order to analyze the correlation between the speed of a train passing over a bridge and the bridge's dynamic response, we conducted a speed-increasing experiment using a real diesel locomotive. To analyze the acceleration response characteristics, we attached seven vertical accelerometers at equal intervals throughout the entire section of the bridge except the supports, and one horizontal accelerometer to the middle span. Linear variable differential transformers (LVDT) were installed at the bridge's center in both vertical and horizontal directions to investigate the vertical and horizontal behaviors. The test train was statically loaded at the center and at the end of the bridge. And its speed was increased from 5 km/h to 90 km/h. With data obtained from the experiment, the vibration level was evaluated in each direction by the filtering frequency, and the level of horizontal vibration was examined in comparison with vertical vibration. The displacement and wheel load variation was analyzed by speed.