• 제목/요약/키워드: Over-excitation

검색결과 292건 처리시간 0.033초

폴리머 매트릭스를 전구체로 사용한 SrAl2O4:Eu2+,Dy3+ 축광성 형광체의 합성 및 형광 특성 (Synthesis and Photo Luminescent Characteristics of SrAl2O4:Eu2+,Dy3+ Phosphor using Polymer Matrix)

  • 김수종;권혁실
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.671-679
    • /
    • 2007
  • [ $SrAl_2O_4:Eu^{2+},\;Dy^{3+}$ ] phosphor was synthesized using the impregnation method, and its photoluminescence and long-afterglow properties were investigated, A mixture of $Sr(NO_3)_2,\;Al(NO_3)_2\;9H_2O,\;EuCl_3\;6H_2O,\;DyCl_3\;6H_2O,\;NdCl_3\;6H_2O$ salts were dissolved in distilled water and impregnating into the polymer precursor. After drying, the impregnated mixture was heat treated at $900-1400^{\circ}C$ for 2h in a $N_2-H_2$ reduction atmosphere. The microstructure and crystal structure of the $SrAl_2O_4:Eu^{2+},\;Dy^{3+}$ powders were examined by scanning electron microscopy and X-ray diffraction, respectively. The photoluminescence spectra showed an excitation band along over wide wavelength of 250-450nm, and a broaden emission with a maxima peak at 360nm. In addition, the spectra also showed a good long after glow that decayed over a 1000sec period after 10 min excitation illumination.

잔류자속을 고려한 변압기 보호용 수정 전류차동 계전방식 (A Modified Current Differential Relaying Algorithm for Transformer Protection Considered by a Remanent Flux)

  • 강용철;김은숙;원성호;임의재;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.262-265
    • /
    • 2003
  • During magnetic inrush or over-excitation saturation of the core in a transformer draws a large exciting current. This can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. In order to cope with the remanent flux at the beginning. the start of saturation of the core is detected and the core flux at the instant is estimated by inserting the differential current into a magnetization curve. Then, this core flux value can be used to calculate the core flux. The proposed relay calculates the core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss current and the magnetizing current from the conventional differential current. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

  • PDF

Y-$\Delta$ 변압기 보호용 수정 전류차동 계전기 (Modified Current Differential Relay for Y-$\Delta$ Transformer Protection)

  • 강용철;김은숙;이병은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.9-13
    • /
    • 2004
  • This paper proposes a modified current differential relay for Y-$\Delta$ transformer protection. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. A method to estimate the circulating component of the delta winding current is proposed. To cope with the remanent flux, before saturation, the core-loss current is calculated and used to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Test results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation because the exciting current was successfully compensated. The relay correctly discriminates magnetic inrush and over-excitation from an internal fault and is not affected by the level of remanent flux.

  • PDF

Sine sweep effect on specimen modal parameters characterization

  • Roy, Nicolas;Violin, Maxime;Cavro, Etienne
    • Advances in aircraft and spacecraft science
    • /
    • 제5권2호
    • /
    • pp.187-204
    • /
    • 2018
  • The sine sweep base excitation test campaign is a major milestone in the process of mechanical qualification of space structures. The objectives of these vibration tests are to qualify the specimen with respect to the dynamic environment induced by the launcher and to demonstrate that the spacecraft FE model is sufficiently well correlated with the test specimen. Dynamic qualification constraints lead to performing base excitation sine tests using a sine sweep over a prescribed frequency range such that at each frequency the response levels at all accelerometers, load cells and strain gages is the same as the steady state response. However, in practice steady state conditions are not always satisfied. If the sweep rate is too high the response levels will be affected by the presence of transients which in turn will have a direct effect on the estimation of modal parameters. A study funded by ESA and AIRBUS D&S was recently carried out in order to investigate the influence of sine sweep rates in actual test conditions. This paper presents the results of this study along with recommendations concerning the choice of methods.

Structural control of cable-stayed bridges under traveling earthquake wave excitation

  • Raheem, Shehata E Abdel
    • Coupled systems mechanics
    • /
    • 제7권3호
    • /
    • pp.269-280
    • /
    • 2018
  • Post-earthquake damages investigation in past and recent earthquakes has illustrated that the ground motion spatial variation plays an important role in the structural response of long span bridges. For the structural control of seismic-induced vibrations of cable-stayed bridges, it is extremely important to include the effects of the ground motion spatial variation in the analysis for design of an effective control system. The feasibility and efficiency of different vibration control strategies for the cable-stayed bridge under multiple support excitations have been examined to enhance a structure's ability to withstand earthquake excitations. Comparison of the response due to non-uniform input ground motion with that due to uniform input demonstrates the importance of accounting for spatial variability of excitations. The performance of the optimized designed control systems for uniform input excitations gets worse dramatically over almost all of the evaluation criteria under multiple-support excitations.

2-Stage Commutated SRM with Auxiliary Winding for Reduction of Acoustic Noise

  • Jung, Tae-Uk
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.22-27
    • /
    • 2008
  • A new excitation strategy for a Switched Reluctance Motor with Auxiliary Winding(SRMAW) is described and tested. The proposed scheme has auxiliary winding with one diode which is wound over all poles in one winding. In this scheme, auxiliary winding is used to reduce magnetic stress during commutations. The abrupt change of a phase excitation produces mechanical stresses resulting in vibration and noise. The acoustic noise is reduced remarkably through the 2-stage commutation. The operational principle and a characteristic comparison of the conventional SRM show that this scheme has some advantages including noise reduction as well as high drive efficiency.

내부 슬로싱 현상을 이용한 사각상자 형태의 부유체 Sway 거동 모사에 대한 수치적 고찰 (Numerical study of sway motion of a rectangular floating body with inner sloshing phenomena)

  • 하민호;정철웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.161-165
    • /
    • 2013
  • In this paper, possibility of controlling motion of a floating structure using a tuned liquid damper (TLD) is numerically investigated. A TLD is a tank partially filled with liquid. Sloshing phenomena of liquid inside a tank can suppress movement of the tank subject to external excitations at specific frequency. The effects of sloshing phenomena inside a rectangular floating body on its sway motion are investigated by varying excitation frequency. First, a grid-refinement study is carried out to ensure validity of grid independent numerical solutions using present numerical techniques. Then, sway motion of the floating body subjected to wave with five different frequencies are simulated. The normalized amplitudes of sway motion of the target floating body are compared over the frequency, for cases with and without water inside the floating body. It is shown that the motion of the floating body can be minimized by matching the sloshing natural frequency to excitation frequency.

  • PDF

불규칙 가진력을 받는 동흡진기의 내부공진효과 (Influence of Internal Resonance on Responses of an Autoparametric Vibration Absorber under Random Excitation)

  • 조덕상;이원경
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.1041-1047
    • /
    • 2000
  • The main objectives of this study are to examine the random response of a vibration absorber system with autoparametric coupling in the neighborhood of internal resonance by Gaussian closure and to compare the results with those obtained by Monte Carlo simulation. The numerical simulation is found to support the main features of the nonlinear modal interaction in the neighborhood of internal resonance conditions. While the Gaussian closure exhibits regions of multiple solutions in the neighborhood of internal resonance, the numerical simulation gives only one solution depending on the assigned initial conditions. The on-off intermittency phenomena of the cantilever mode is observed in the Monte Carlo simulation over a small range of parameter.

  • PDF

제주-해남 HVDC 시스템에서 클리폰 릴레이 오동작 분석에 관한 연구 (A Study on the Analysis of Klippon Relay Malfunction in Cheju-Heanam HVDC System)

  • 김찬기;박종광;최영도
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.173-175
    • /
    • 2005
  • Malfunction of Klippon relay in Cheju-Haenam HVDC system has been caused by the inflow of high voltage arc. In this paper, we have studied on the theoretical examination and data analysis of Klippon relay, and the countermeasures against the problems were suggested according to their causes. Grounding problem in Klippon relay is removed by one-point earth connection and by modification of grounding circuit. The effects of over current surge was removed by attaching blocking diodes by series In Klippon relay to remove surge input in Klippon relay's mercury contact. The problem of Induced overvoltage by 86re1ay excitation coil, was removed by attaching Free-wheeling diode in parallel with the excitation coil of Lock-out relay.

  • PDF

HVDC 시스템에서 클리폰 릴레이 오동작 분석에 관한 연구 (A Study of Analysis on Klippon Relay Malfunction in HVDC System)

  • 김찬기;박종광;추진부
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.437-443
    • /
    • 2005
  • This paper deals with an experimental study for Klippon reiay in Cheju-Heanam HVDC system Klippon relay was troubled many times for years, and Klippon relay's fault caused the HVDC system trip. So for several years, these reasons of Klippon relay fault were investigated. The malfunction of Klippon relay in Cheju-Haenam HVDC system has been caused by the incoming of random surge(current source and voltage source). This paper has stu야ed the theoretic리 analysis and experimental study of Klippon relay, and the solutions against the problems were suggested according to their causes. Among the problems, grounding problem was removed by one-point earth connection and by modification of grounding circuit. The effects of inrush current was removed by inserting the blocking diodes by series in Klippon relay circuits. Finally, The over-voltage induced on Klippon relay, by a relay excitation coil, was removed by inserting a free-wheeling diode in Parallel with the excitation coil.