Development of Protection Device for Voltage Unbalance Faults using Three-Phase Neutral Voltage (삼상 중성점 전압을 이용한 전압불평형 사고 방지용 보호장치 개발)

  • Kwak, D.K.;Kim, D.S.;Kim, J.H.;Kim, S.C.;Jung, W.S.;Son, J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.621-622
    • /
    • 2012
  • The thermal over-current relay or electronic motor protection relay is mostly used as the open-phase detection device of the three-phase motor or load. When the over-current or overheat of electric line is generated, it detects and operates circuit breaker, but there is the defect that the sensing speed is slow, the operation can be sometimes failed, and the precision is decreased. In order to improve these problems, this paper is proposed a new control circuit topology for open-phase protection using semiconductor devices. Therefore, the proposed open-phase protection device enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase motor control panel in the field, as it manufactures into small size and light weight.

  • PDF

Design of 2-4 Cell Li-ion Multi Battery Protection Analog Front End(AFE) IC (2-4 cell 리튬이온 멀티 배터리 보호회로 Analog Front End(AFE) IC 설계)

  • Kim, Sun-Jun;Kim, Jun-Sik;Park, Shi-Hong
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.324-329
    • /
    • 2011
  • In recent years, the performance and functions of portable devices has increased. so it requires more power efficiency and energy density while using the battery for a long time. therefore Battery pack which are made up from several battery cells in series in order to achieve higher operating voltage is being used. when using a Li-ion battery, we need a protection circuit to protect from overcharge, over discharge, high temperature and over current. Also, when using battery pack, we need to Cell voltage balancing circuit that each cell in tune with the balancing. In this paper, the proposed IC is applicable by mobile devices as well as E-bike, hybrid vehicles, electric vehicles, and is expected to contribute to the development of domestic PMIC.

Traction IGBT Modules Design Issues and Precautions (전철용 IGBT 모듈 설계연구)

  • Gopal, Devarajan;Lho, Young-Hwan;Kim, Yoon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1853-1859
    • /
    • 2008
  • IGBT modules are designed for low loss, rugged for all environments and user friendly. Low on state saturation voltage with high switching speed is the primary concerns. In this paper selection of IGBT, module ratings and characteristics are discussed. The IGBT design topic of protection against over voltage and over current are covered. Emphasis on turn off switching, short circuit switching and necessary precautions are dealt. Selection of IGBT device, gate drive power, and its lay out considerations are covered in detail.

  • PDF

Application of Multi-step Undervoltage Load Shedding Schemes to the KEPCO System

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Choy, Young-Do;Kim, Tae-Kyun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.476-484
    • /
    • 2009
  • This paper deals with improvements to the special protection schemes (SPS) which have been applied to the low probability and high impact contingencies in the Korea Electric Power Corporation (KEPCO) system since 2004. Among them, the SPS for voltage instability in the Seoul metropolitan area is considered in this paper, and is a form of event-based undervoltage load shedding with a single-step scheme. Simulation results based upon a recent event that occurred on 765kV lines show that the current setting values of the SPS have to be revised and enhanced. In addition, by applying response-based multi-step undervoltage load shedding (UVLS) schemes to severe contingencies in the system, more effective results than those of the existing single-step SPS can be obtained. Centralized and distributed UVLS schemes are considered in the simulation. ULTC-based load recovery models and over excitation limiters (OXL) for the KEPCO system are also included in the long-term voltage instability studies.

Practical Design and Implementation of a Power Factor Correction Valley-Fill Flyback Converter with Reduced DC Link Capacitor Volume (저감된 DC Link Capacitor 부피를 가지는 역률 개선 Valley-Fill Flyback 컨버터의 설계 및 구현)

  • Kim, Se-Min;Kang, Kyung-Soo;Kong, Sung-Jae;Yoo, Hye-Mi;Roh, Chung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.277-284
    • /
    • 2017
  • For passive power factor correction, the valley fill circuit approach is attractive for low power applications because of low cost, high efficiency, and simple circuit design. However, to vouch for the product quality, two dc-link capacitors in the valley fill circuit should be selected to withstand the peak rectified ac input voltage. The common mode (CM) and differential mode (DM) choke should be used to suppress the electromagnetic interference (EMI) noise, thereby resulting in large size volume product. This paper presents the practical design and implementation of a valley fill flyback converter with reduced dc link capacitors and EMI magnetic volumes. By using the proposed over voltage protection circuit, dc-link capacitors in the valley fill circuit can be selected to withstand half the peak rectified ac input voltage, and the proposed CM/DM choke can be successfully adopted. The proposed circuit effectiveness is shown by simulation and experimentally verified by a 78W prototype.

Design of the Protection circuit for Electric ballast with $LC_SC_P$ resonance type Half-bridge Inverter ($LC_SC_P$ 공진 타입의 하프 브리지 인버터 구조를 가지는 전자식 안정기 보호회로 설계)

  • Choe, Hyeon-Hui;Park, Chong-Yun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1538-1543
    • /
    • 2009
  • The electric ballast for ceramic metal halide lamp needs a protection circuit to prevent from over voltage and over current in the case that the lamp or the electric ballast are in faults. In this paper, cost-effective and high performance protection circuit is proposed for the electric ballast. The proposed protection circuit is adapted to the electric ballast with $LC_SC_P$ resonance type half bridge inverter. The experimental results demonstrate that the proposed circuit can protect effectively under open and short fault conditions.

Abnormal Voltage Detection Circuit with Single Supply Using Threshold of MOS-FET for Power Supply Input Stage (FET 문턱전압 특징을 이용한 전원입력단용 단일전원 이상전원 검출회로)

  • Won, Joo Ho;Ko, Hyoungho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.107-113
    • /
    • 2016
  • All circuits in power input can only use the power provided by an external power supply. General electronic circuits use a secondary supply generated by a converter using a primary power in the power input. But protection and detection circuit for over-voltage circuit or under-voltage in power input have to use that input power because there is no other supply in power input. Therefore, previous electronics for satellite can protect only over-voltage using a zener diode, and can't detect over-voltage and under-voltage events, and provide a detection capability for over-voltage and under-voltage only for secondary supply. The proposed circuit can detect over-voltage and under-voltage using a single supply for the primary power input, +28V, with the threshold characteristics for MOS-FET, and the accuracy for a detection circuit is increased by 2.5%.

The Ballast for Field Emission Lamp with CNT Emitter (CNT를 이용한 무수은 면광원 안정기 개발)

  • Park, Dong-Hyuck;Ha, Seok-Jin;Jung, Hye-Man;Kim, Jong-Hyun;Baek, Ju-Won;Yoo, Dong-Wook;Song, Eui-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.31-37
    • /
    • 2009
  • Hybrid ballast for field emission lamp with CNT (carbon nano tube) emitter is proposed. Hybrid ballast consists of a high voltage dc part and hi-polar pulse generation part. Field emission lamp with CNT lamp is composed of three electrodes (anode, gate, and cathode). High voltage dc part is for anode and gate and hi-polar pulse generation part is for gate and cathode in CNT triode respectively. The experimental results demonstrate that the proposed topology is good for driving CNT lamp. To protect the lamp and ballast, OCP (Over Current Protection), OVP (Over Voltage Protection), and OTP (Over Temperature Protection) are added and the experimental results demonstrate that the proposed method is good for driving field emission lamp with CNT emitter.

Characteristics of ZnO Arrester Blocks Leakage Currents under Mixed Direct and 60 Hz Alternating Voltages (직류와 60 Hz 교류가 중첩된 전압에 대한 산화아연 피뢰기 소자의 누설전류 특성)

  • Lee Bok-Hee;Kang Sung-Man;Pak Keon-Young
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.1
    • /
    • pp.23-29
    • /
    • 2005
  • This paper presents the characteristics of leakage currents flowing through ZinC Oxide(ZnO) surge arrester blocks under mixed direct and 60 Hz alternating voltages. A mixed voltage, in which an alternating voltage is superimposed upon a direct voltage, appears on the HVDC system network. The mixed direct and alternating voltage generator with a peak open-circuit of 10 kV was designed and fabricated. The leakage currents and V-I curves for the fine and used ZnO surge arrester blocks were measured as a function of the voltage ratio k, where the voltage ratio k is defined as the ratio of the peak of alternating voltage to the peak of the mixed voltages. The resistive component in the leakage current in the low conduction region is significantly increased with increasing the voltage ratio k. The V-I characteristic curves for the mixed voltages lies between the direct and alternating characteristics, and the cross-over phenomenon in the high conduction region was appeared.

Emergency Brushless Synchronous Generator Having Rotating Exciter Status Monitoring and Protection Functions

  • Oh, Yongseung;Oh, Wonseok;Cho, Kyumin
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.1-13
    • /
    • 2020
  • This paper presents an emergency brushless synchronous generator having rotating exciter status monitoring and protection functions. For monitoring the rotating exciter status, a wireless rotor status detector and a digital AVR(Automatic Voltage Regulator), which has a wireless communication capability, are proposed. The proposed rotor status detector detects temperatures of exciter armature and main field windings and input voltage and current of the main field. Therefore, it is possible to protect the generator from the over-temperature of windings and detect the exciter bridge diode fault. Furthermore, the proposed digital AVR has rotor status monitoring and protection function, and remote generator tuning, wireless group parallel operation function. So the operator can efficiently operate the generator using a smartphone from a remote area.