• Title/Summary/Keyword: Outdoor tests

Search Result 193, Processing Time 0.038 seconds

Field Test to Investigate Heat Transferring Effect of Carbon Fiber Heating Wire on the Concrete Slab (현장시험을 통한 Carbon fiber heating wire의 콘크리트슬래브 열전달 효과)

  • Kim, Hee Su;Ban, Hoki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.4
    • /
    • pp.31-38
    • /
    • 2019
  • Field tests with carbon fiber heating wire (CFHW) embedded inside concrete slab were performed to present the alternative heating material capable of avoid the adverse effects of traditional de-freezing salt on the structures and environment. The CFHW was inserted into the concrete slab in the shape of 'ㄷ' to improve the heat superposition and the temperature on the surface was measured using iButton. The results showed that the temperature where the CFHW's were faced with each other increased to above zero after 12-hour at outdoor air temperature of $-6^{\circ}C$. Comparatively, the temperature slightly increased where the CFHW was embedded on one side because the heat was not superimposed. Hence, it can be said that the CFHW is a suitable heating material to prevent the concrete road from being frozen.

A Feasibility Study of Wood-plastic Composite Paver Block for Basic Rest Areas

  • Yang, Sungchul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.51-65
    • /
    • 2019
  • A wood-plastic composite (WPC) paver block was manufactured using wood chips waste through an extrusion process, and it was intended to be used for paving in basic rest areas. The first stage in this study covered preliminary tests in terms of flexural strength and dimensional swelling to determine the optimal WPC compounding mix condition, by variation of the WPC ingredients. Next, three different paver blocks including the WPC block, a non-porous cement block, and a porous cement block were tested in terms of various material properties in the laboratory. Finally, two outdoor test sections of the proposed paver blocks were prepared to simulate a basic rest area. Test results indicated that the flexural strength of the WPC paver blocks was about 1.6 times greater than that of the tested cement paver blocks. The WPC block pavement was unaffected by water buoyance as well as volume expansion due to swelling. Results from the impact absorbance test and light falling weight deflectometer (LFWD) test clearly showed that the WPC block paving system marginally satisfied the comfortable and safe hardness range from the pedestrians' perspective, while the results demonstrated that it is structurally sound for application as a road paving block.

Atmospheric Corrosion Behavior of Weathering Steel Exposed to the Outdoors for 10 Years in Korea

  • Yoo, Y.R.;Choi, S.H.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.258-272
    • /
    • 2022
  • Steel structures exposed to the outdoors experienced several types of corrosion, which may reduce their thickness. Since atmospheric corrosion can induce economic losses, it is important to consider the atmospheric corrosion behavior of a variety of metals and alloys. This work performed outdoor exposure tests for 10 years at 14 areas in Korea and calculated the atmospheric corrosion rate of weathering steel. This paper discussed the atmospheric corrosion behavior of weathering steel based on various corrosion factors. The average corrosion rates in coastal, industrial, urban, and rural areas were found to range from (2.83 to 4.23) ㎛/y, (2.99 to 4.23) ㎛/y, (1.72 to 3.14) ㎛/y, and (1.57 to 2.85) ㎛/y respectively. It should be noted that the maximum corrosion rate was about 6.0 times greater than the average corrosion rate. Regardless of the exposure sites, the color differences were increased, but the glossiness was reduced and there was no relationship between the corrosion rate and environmental factors and the glossiness.

Submarine Free Running Model Development and Basic Performance Analysis (수중함 자유항주모형 개발 및 기본 성능 분석)

  • Jooho Lee;Seonhong Kim;Jihwan Shin;Jinhyeong Ahn
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.256-265
    • /
    • 2023
  • This paper describes the results of the development of the submarine Free Running Model (FRM). First, the goal of development was set based on the test conditions and the test environment, and the system was obtained accordingly. The target submarine, Joubert BB2 submarine, was selected with a scale of 18.35 in accordance with the development goal. In order to conduct a submarine FRM test underwater, where communication is impossible, the FRM must operate at least semi-autonomously. For this purpose, an Extended Kalman Filter (EKF) based underwater integrated navigation system and control system using a sailplane and an X-shaped sternplane were designed respectively. In addition, a ballast system was designed to enable the model to float to the water surface in case of an emergency. To verify its propulsion, navigation, and control performance, the FRM tests were conducted in both indoor and outdoor basins. As a result, the relationship between propeller RPM and vehicle speed was derived, and it was confirmed that the navigation and control performance met the target value.

Development and Utilization of Eco-friendly Products based on Hemp Fabrics (대마 기반 친환경 의류 제품의 개발 및 활용에 관한 연구)

  • Su-Hyun Kim;Hee-Sook Kim
    • Fashion & Textile Research Journal
    • /
    • v.25 no.1
    • /
    • pp.62-71
    • /
    • 2023
  • Recently, interest in natural fabric materials that are not harmful has increased, and hemp is being studied as a new eco-friendly product. This study produced hemp fabric with improved flexibility and increased antibacterial properties by blending it with Hanji yarn. Various weaving methods were proposed to overcome the rough physical properties of hemp, and the functions of the developed products were evaluated through antibacterial tests. The mixing ratios of hemp and Hanji yarns was 50% hemp: 50% Hanji weft, 70% hemp: 30% Hanji weft, 30% hemp: 70% Hanji weft, and 100% hemp. Overall, the higher the ratio of Hanji yarn, the higher the fastness property, and the higher the ratio of hemp yarn, the higher the flexibility of the fabric, which was evaluated to be comfortable to wear. The 99.9% antibacterial properties of hemp products were considered to contribute to maintaining the health of modern people. Owing to its high intensity and high air permeability, it is considered highly usable in the production of children's clothing with a lot of activity. It was evaluated as an advantage that the disadvantage of hemp, which was limited as a material for summer clothing, was broadened to use for all seasons due to the fusion of Hanji. Otherwise, low consumer satisfaction as an outdoor wear is a disadvantage because hemp products had low elasticity and wrinkles.

A Research on Autonomous Mobile LiDAR Performance between Lab and Field Environment (자율주행차량 모바일 LiDAR의 실내외 성능 비교 연구)

  • Ji yoon Kim;Bum jin Park;Jisoo Kim
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.4
    • /
    • pp.194-210
    • /
    • 2023
  • LiDAR plays a key role in autonomous vehicles, where it is used to detect the environment in place of the driver's eyes, and its role is expanding. In recent years, there has been a growing need to test the performance of LiDARs installed in autonomous vehicles. Many LiDAR performance tests have been conducted in simulated and indoor(lab) environments, but the number of tests in outdoor(field) and real-world road environments has been minimal. In this study, we compared LiDAR performance under the same conditions lab and field to determine the relationship between lab and field tests and to establish the characteristics and roles of each test environment. The experimental results showed that LiDAR detection performance varies depending on the lighting environment (direct sunlight, led) and the detected object. In particular, the effect of decreasing intensity due to increasing distance and rainfall is greater outdoors, suggesting that both lab and field experiments are necessary when testing LiDAR detection performance on objects. The results of this study are expected to be useful for organizations conducting research on the use of LiDAR sensors and facilities for LiDAR sensors.

Evaluation of Apparent Chloride Diffusion Coefficient and Surface Chloride Contents of FA concrete Exposed Splash zone Considering Crack Width (비말 지역에 노출된 FA 콘크리트의 균열을 고려한 겉보기 염화물 확산계수 및 표면 염화물량 평가)

  • Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.18-25
    • /
    • 2019
  • The cracks occurred during service life of concrete structure should be considered in durability design, because of the concrete's material property which is weak in tensile strength. In this study, the fly ash concrete mixtures considering 2 levels of strength is designed and outdoor exposure tests are conducted for those concrete specimens. The exposure environment is set to a splash zone, and in order to evaluate the effect of crack width on the behavior of chloride diffusion, the crack width of up to 1.0 mm is generated at intervals of 0.1 mm at each concrete mixture. After that, apparent chloride diffusion coefficient and surface chloride contents are deducted considering 3 levels of exposure periods(180 days, 365 days, 730 days). The diffusion coefficients of two types of mixture increase with the increase of crack width, and the diffusion coefficients decrease with the increase of exposure periods. In addition, the effect of the crack width on the diffusion coefficient is reduced as the exposure periods increase, which is attributed to the extra hydrate by chloride ion reducing the diffusivity of concrete. The behavior of the surface chloride contents does not significantly change by the increase in crack width, compared to the behavior of apparent chloride diffusion coefficient. Also, In the high strength FA concrete mixture, the surface chloride contents are 78.9 % ~ 90.7 % than the normal FA strength concrete mixture. Thus, Surface chloride contents have correlation with the strength of concrete.

Measurement of Vertical-Directional DTV Signal Level Using a Multi-Copter (멀티콥터를 이용한 수직방향 DTV 신호 레벨 측정)

  • Park, Hyung-Do;Lim, Sol;Kim, Dae Jin
    • Journal of Broadcast Engineering
    • /
    • v.19 no.3
    • /
    • pp.372-384
    • /
    • 2014
  • DTV field tests have been performed to measure field strength and to check reception ratio on indoor and outdoor sites. They use an antenna of 9m to measure DTV signal in case of outdoor measurement on the road. Modern skyscrapers require the analysis of vertical-directional wave propagation by measuring vertical-directional DTV signal. Even if the field strength is above the reception threshold of $43dB{\mu}V/m$, the reception is impossible in case of strong multi-path or high impulse noise. So, vertical-directional field measurement is essential in environment of tall buildings. In this paper, we developed an octo type multi-copter to measure vertical-directional DTV signal level. A compact and portable DTV signal level meter, an antenna, a microwave transmitter for data transmission, and a recording equipment are equipped in the multi-copter. Three different sites are selected to test the measurement system. Developed measurement system using the multi-copter is very useful in measuring vertical-directional DTV signal, especially in apartments, non-accessible area by vehicles, and forbidden areas.

Optimization of the Refrigerant Charge and the Expansion Valve Opening for the Soft Ice Cream Machine Using R-404A (R-404A를 사용하는 소프트 아이스크림 제조기의 냉매 충전량 및 팽창 밸브 개도 최적화)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.728-734
    • /
    • 2016
  • The improvements of living and lifestyle have led to the increased sales of frozen milk products, such as soft ice cream or slush. These frozen milk products are commonly made in small refrigeration machines. R-502, which has long been used as the refrigerant in soft ice cream machines, is being replaced with R-404A due to the ozone layer depletion issue. In this study, an optimization and performance evaluation were conducted on a soft ice cream machine with a freezer volume of 2.8 liters. The optimization focused on the appropriate refrigerant charge and expansion valve opening. Under the optimized conditions, ice cream was produced in 10 minutes and 5 seconds, and the COP was 0.57. The performance tests included ice cream sales with no interval, ice cream sales with 30 second intervals and under extreme outdoor conditions. The results showed that 20 sales were possible with no interval, and infinite sales could be made with 30 seconds intervals. Ice cream sales were also possible under summer or winter outdoor conditions. The present results may be used for the design of food refrigeration machines as well as to optimize other refrigeration cycles.

Structural Integrity Evaluation of Mechanically Fastened FRP Beams Under the Effects of Sustained Loads and Environments (지속하중과 환경영향을 받은 MF-FRP 보강보의 구조건전성 평가)

  • Lee, Jae-Ha;Kim, Woo-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • Mechanically fastening FRP (MF-FRP) strips using nails and anchors, has been shown to provide a more ductile behavior to the strengthened structural element than using bonded FRP. To further advance the state of the knowledge on this strengthening method, the current study examined environmental effects for six months on MF-FRP beams. Reinforced concrete beams strengthened with mechanically fastened FRP strips and subjected to sustained loads for six months were exposed to outdoor weather and constant high temperatures ($40^{\circ}C$). For comparison, the behavior of RC beam with and without sustained loads was evaluated. Results from flexural tests did not show any significant degradation or change of failure mode as a result of sustained load and of environmental effects such as high temperatures and outdoor weather over a period of six months. Failure of the beams was governed by FRP delamination followed by concrete crushing as not much load applied to the nail and anchors because of slip effects.