• Title/Summary/Keyword: Oscillation methods

Search Result 176, Processing Time 0.03 seconds

The Effects of Paced Breathing in Specific Respiration Rate on Heart Rate Variability (특정 호흡수에서 행한 통제호흡이 심박변이도에 미치는 영향)

  • Kim, Ji-Hwan;Kim, Byoung-Soo;Park, Seong-Sik;Lee, Yong-Jae;Keum, Na-Rae;Bae, Hyo-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.28 no.2
    • /
    • pp.123-131
    • /
    • 2016
  • Objectives We observed what effects of Paced Breathing(PB) in specific respiration rate have on heart rate variability (HRV) according to Sasang Constitution.Methods HRV of 72 healthy participants in sitting position was recorded while they carried out usual breathing, 0.2Hz, 0.1Hz, and 0.05Hz PB each 5 minutes in consecutive order. Five minute of relaxation was permitted between each breathing. Finally, HRV indices were statictically analyzed of 32 participants (SOEUM: 11, SOYANG: 10, TAEEUM: 11) after data out of accord with respiration rate or outliers were excluded.Results and Conclusions According to respiration rates, there was no statistical significance of HRV among Sasang Constitution. Regardless of Sasang Constituion, 0.2Hz PB increased mean heart rate and decreased natural logarithmic low frequency(lnLF) oscillation of HRV without the change of natural logarithmic high frequency(lnHF), while 0.1Hz PB increased lnLF and standard deviation of N-N interval(SDNN), and slightly decreased lnHF without the change of mean heart rate. 0.05 Hz PB also showed the same effect as 0.1Hz PB, but was impracticable.

Optimal design of car suspension springs by using a response surface method (반응 표면 분석법을 활용한 자동차용 현가스프링 최적화 설계)

  • Yoo, Dong-Woo;Kim, Do-Yeop;Shin, Dong-Gyu
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.246-255
    • /
    • 2016
  • When spring of the suspension is exerted by an external load, a car should be designed to prevent predictable damages and designed for a ride comfort. We used experiments design to design VON-MISES STRESS and K, a constant, of spring of suspension which is installed in a car as a goal level. We analyzed the result from Edison's Elastic - Plastic Analysis SW(CSD_EPLAST) by setting D, d, n as external diameter of coil, internal diameter of coil, the number of total coil respectively. The experiment design let the outcome be as Full-second order by using Box-Behnken which is one of response surface methods. Experimented and analyzed results based on the established experiments design, We found out design parameter which has desired VON-MISES STRESS and the constant K. Additionally, we predicted life time of when the external load was exerted by repeated load by using fatigue equation, and verification of plastic deformation has also been made. Additionally we interpreted a model, which is formed by optimized design parameter, with linear analysis and non-linear analysis, at the same time we also analyzed plastic deformation with the values from the both models. Finally, we predicted fatigue life of optimized model by using fatigue estimation theory and also evaluated a ride comfort with oscillation analysis.

  • PDF

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

Fabrication and Time-Dependent Analysis of Micro-Hole in GaAs(100) Single Crystal Wafer Using Wet Chemical Etching Method (습식 화학적 식각 방법에 의한 시간에 따른 GaAs(100) 단결정 웨이퍼에서의 마이크로 구멍의 제작 및 분석)

  • Lee, Ha Young;Kwak, Min Sub;Lim, Kyung-Won;Ahn, Hyung Soo;Yi, Sam Nyung
    • Korean Journal of Materials Research
    • /
    • v.29 no.3
    • /
    • pp.155-159
    • /
    • 2019
  • Surface plasmon resonance is the resonant oscillation of conduction electrons at the interface between negative and positive permittivity material stimulated by incident light. In particular, when light transmits through the metallic microhole structures, it shows an increased intensity of light. Thus, it is used to increase the efficiency of devices such as LEDs, solar cells, and sensors. There are various methods to make micro-hole structures. In this experiment, micro holes are formed using a wet chemical etching method, which is inexpensive and can be mass processed. The shape of the holes depends on crystal facets, temperature, the concentration of the etchant solution, and etching time. We select a GaAs(100) single crystal wafer in this experiment and satisfactory results are obtained under the ratio of etchant solution with $H_2SO_4:H_2O_2:H_2O=1:5:5$. The morphology of micro holes according to the temperature and time is observed using field emission - scanning electron microscopy (FE-SEM). The etching mechanism at the corners and sidewalls is explained through the configuration of atoms.

Sorghum Harvesting Using a Head-feeding Type Rice Combine

  • Jun, Hyeon Jong;Choi, Il Su;Kang, Tae Gyoung;Choi, Yong;Choi, Duck Kyu;Lee, Choung Keun;Kim, Sang Hun
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.296-302
    • /
    • 2018
  • Purpose: The aim of this study was to determine appropriate threshing and selection conditions for sorghum harvesting using a rice combine-harvester. Methods: Sorghum harvesting performance was tested using an actual rice combine. Through this test, the grain loss rate and the composition of crops according to the engine and fan speeds of the combine were investigated. Furthermore, the optimal threshing and selection conditions were determined by carrying out a harvest test based on the opening size factor of the concave in a test field. Results: The grain loss rate for the sorghum using a concave ($18{\times}18mm$) of the rice combine was the lowest at 0.1% at a chaffer angle of $40^{\circ}$, engine speed of 2000 rpm, and fan speed of 20 m/s, but the sorting sieve clogged frequently. Furthermore, as the engine speed and fan speed increased, the grain loss rate also increased. The sorghum harvesting test results of the combine according to the concave opening size showed that the grain loss rate was 0.5% at a driving speed of 0.5 m/s, with a concave opening diameter of 13 mm, a chaffer angle of $40^{\circ}$, a concave sieve oscillation frequency of 4.8 Hz, a fan speed of 20 m/s, and an engine speed of 2000 rpm. Conclusions: Findings showed that sorghum could be harvested using a head feeding rice combine.

Melting of Al2O3 powder using the skull melting method (Skull melting법에 의한 Al2O3 파우더 용융)

  • Choi, Hyun-Min;Kim, Young-Chool;Seok, Jeong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.1
    • /
    • pp.24-31
    • /
    • 2019
  • The current study demonstrates an efficient procedure to create ingots from $Al_2O_3$ powder using the skull melting method to use these ingots as a starting material in conventional methods for growing synthetic single-crystal sapphire. Dimension of the cold crucible was 24 cm in inner diameter and 30 cm in inner height, 15 kg of $Al_2O_3$ powder was completely melted within 1 h at an oscillation frequency of 2.75 MHz, maintained in the molten state for 3 h, and finally air-cooled. The areal density and components of the cooled ingot by parts were analyzed through scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS). The areal density and $Al_2O_3$ content of the ingot were related to the temperature distribution inside the cold crucible during high-frequency induction heating, and the area with high temperature was high tends to be high in areal density and purity.

A study on the change of characteristics and frequency correction method of OCXO by temperature sensor position (온도 센서 위치에 의한 OCXO의 특성 변화와 주파수 보정 방법 연구)

  • Cho, Gyu-Pil;Lee, Young-Soon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.129-135
    • /
    • 2020
  • This study relates to a characteristic change and frequency correction method according to the temperature sensor position of an oven-controlled crystal oscillator (OCXO) using a 10 MHz SC-CUT crystal. Although there are several methods of manufacturing the previous high-precision 10MHz OCXO, the present study shows that the frequency stability characteristics against external temperature changes can be improved simply by adjusting the position of the temperature sensor. Factors that affect the frequency characteristics of the OCXO include the temperature transmitted to the crystal, the voltage applied to the crystal, and the capacitance constituting the oscillation circuit. The amount of change in frequency due to these factors was measured, and the change in the correction value of the OCXO output frequency was investigated by measuring the temperature inflection point and changing the capacitor value.

A Comparison of Dizziness Handicap Inventory Scores with Stability Index and Fourier Harmony Index in Healthy Individuals

  • Sang-Seok Yeo;Heun-Jae Ryu
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.4
    • /
    • pp.105-110
    • /
    • 2023
  • Purpose: The purpose of this study was to determine whether the degree of dizziness affects static balance due to the disruption or absence of the senses involved in balance. To this end, the correlation between the Dizziness Handicap Inventory (DHI), which objectively evaluates dizziness, the Fourier Index (FI; Frequency bands of postural oscillation, F1, F2-4, F5-6, F7-8) and the Stability Index (ST), which evaluates static balance ability, were examined. Methods: This study investigated balance and dizziness issues in 30 healthy young adults. Participants underwent multiple tests like the DHI and tetra-ataxiometric posturography (Tetrax) under different conditions (eyes open/closed, standing on a foam-rubber pillow, and with the head in various orientations). Results: We found that F1 exhibited a weak positive correlation with dizziness under normal conditions, as well as when the eyes were closed (r=0.396, p<0.05) and the head was tilted back (r=0.375, p<0.05). Meanwhile, F5-6 showed a moderate positive correlation with dizziness in both head-back (HB: r=0.471, p<0.05) and head-forward postures (r=0.404, p<0.05). Lastly, both F7-8 and ST demonstrated a moderate positive correlation with dizziness when the head was in a forward posture (F7-8: r=0.483; ST: r=0.403, p<0.05). Conclusion: The study results indicate that the severity of dizziness affects sensory systems and balance. It also suggests that head movements, especially forward and backward, further stimulate the vestibular system, intensifying dizziness, and balance problems in affected individuals.

Improvement Effects of Cement Grouting using Vibration Method through a Field Test (현장시험을 통한 시멘트 진동주입공법의 보강효과)

  • Han, Sanghyun;Yea, Geugweun;Kim, Hongyeon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.23-29
    • /
    • 2014
  • So far, the grouting using pressure injection has been extensively used to avoid adverse effects such as soil disturbance. Whereas, the pressure injection to the limitations of the diffusion range, so that the kinks would last injection of cement particles by introducing a frequency oscillation effect improved injection method have been recently developed. In this study, a pilot test was performed to compare injection effects of the both methods. The injections using both methods were tested on the embankment which consists of core clay and weathered soil. Subsequently, the injected volume, SPT N values, in-situ permeability and electrical resistivity were measured to compare their effects. The vibration method showed more effective permeation comparing with the pressure method. Also, it showed more homogeneously improved ground than the existing method. For SPT results, the vibration method presented increase of mean N value as much as 17.4 % comparing with the conventional method. Higher electrical resistivity was presented in case of injecting with vibration method and it indicated the injection was extensively completed. Finally, it is expected that the economic feasibility will be improved by decrease of drilling spacing, when the existing method is replaced with vibration method.

A Study on Stabilization of Underwater TAS Winch System Deploy/Recover Operation Performance (수중용 TAS윈치 전개/회수 성능 안정화 방안에 관한 연구)

  • Chang, Ho-Seong;Cho, Kyu-Lyong;Hwang, Jae-Gyo;Lee, Sang-Yong;Kim, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.472-482
    • /
    • 2019
  • This paper describes the stabilization of underwater TAS winch system Deploy/Recover operation performance. TAS winch installed on the stern of submarine performs to deploy/recover sensor, towing cable and rope tail which is deployed from the stern and separated from submarine itself. Also TAS winch provides transmission path of power to the sensor and data transmitting/receiving path which data are acquired from underwater environment like sound, depth and temperature. At the step of TAS winch evaluation test, sporadic standstill and rotating speed oscillation phenomenon were occurred. Winch motor provides the available torque to deploy/recover TAS and root cause analysis to the winch motor was done to find exact reason to sporadic malfunction. When winch motor was disassembled, eccentricity of rotor, slip-ring and the other composition part for winch motor were found. These might cause magnetic field distortion. To make TAS winch system more stable and block magnetic field distortion, this paper suggests methods to enhance fixing status installed in winch motor. For reliable data acquisition for TAS winch operation, the deploy/recover function of the improved type of TAS winch was verified in LBTS making similar condition with sea status. At the end of stage, improved type of TAS winch was tested on some functions not only deploy/recover function, but sustainability of TAS operation on specific velocity, steering angle of submarine in the sea trial. Improved type of TAS winch was verified in accordance with design requirement. Also, validity of suggested methods were verified by the sea trial.