• 제목/요약/키워드: Orthodontic appliance design

검색결과 15건 처리시간 0.017초

투명교정장치의 임상적 한계와 그 해결 (Clinical limitations and its solutions of the clear overlay appliance treatment)

  • 배기선
    • 대한치과의사협회지
    • /
    • 제54권7호
    • /
    • pp.563-574
    • /
    • 2016
  • A clear overlay appliance is a type of a removable appliance made from transparent thermoplastic plastic film that covers the entire dentition to move the teeth. It is one of the most favored orthodontic methods opted for by adult patients; this treatment is esthetic, does not cause discomfort and allows oral hygiene to be easily managed when compared to other conventional fixed treatment methods. However, the use of clear overlay appliances, such as invisalign or clear aligner, is associated with various clinical challenges. In particular, the appliances require longer treatment periods compared to fixed treatment, and due to the structural characteristics of the appliances, it is difficult to make proper posterior occlusion and certain type of tooth movement, including extrusion, rotation and tip. Thus, the clear overlay appliances are regarded as supplementary appliances by most orthodontists and have been used for simple orthodontic treatments, such as partial anterior alignments or orthodontic relapse cases. Owing to the remarkable advancement in the field of 3D digital technology over a period of 15 years, the accuracy and convenience of modern clear overlay appliances have continuously improved. Moreover, orthodontic outcomes have also been greatly improved by the introduction of new materials and successful application of various biomechanical methods from conventional orthodontic treatments in the design of clear overlay appliances. This study investigates the clinical limitations that should be considered during the application of clear overlay appliances and also examines the efforts and methods used to overcome these challenges.

  • PDF

$Fr{\ddot{a}}nkel$의 Functional Regulator II 제작 (Construction of Frankel Functional Regulator II)

  • 이규선
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.21-38
    • /
    • 2000
  • $Fr{\ddot{a}}nkel$ functional regulator have a complicated design and are of a big bulk. This makes not only the construction of appliance but also the adaption of a patient to the appliance very difficult. Therefore, orthodontic laboratory technicians should be well acquainted with the sequential fabrication procedures involved in the construction of Frankel functional regulators and construct a type most suitable for a specific patient of malocclusion. There are various types of Frankel appliances. Detailed construction procedures of FR II are described here below, which can also be applied for other types for FR appliances.

  • PDF

Maxillary space closure using a digital manufactured Mesialslider in a single appointment workflow

  • Wilhelmy, Lynn;Willmann, Jan H.;Tarraf, Nour Eldin;Wilmes, Benedict;Drescher, Dieter
    • 대한치과교정학회지
    • /
    • 제52권3호
    • /
    • pp.236-245
    • /
    • 2022
  • New digital technologies, many involving three-dimensional printing, bring benefits for clinical applications. This article reports on the clinical procedure and fabrication of a skeletally anchored mesialization appliance (Mesialslider) using computer-aided design/computer-aided manufacturing (CAD/CAM) for space closure of a congenitally missing lateral incisor in a 12-year-old female patient. The insertion of the mini-implants and appliance was performed in a single appointment. Bodily movement of the molars was achieved using the Mesialslider. Anchorage loss, such as deviation of the anterior midline or palatal tilting of the anterior teeth, was completely avoided. CAD/CAM facilitates safe and precise insertion of mini-implants. Further, mini-implants can improve patient comfort by reducing the number of office visits and eliminating the need for orthodontic bands and physical impressions.

부산, 경남지역 치과기공사의 직무분석 (The job analysis of dental technicians in Busan, Gyeongnam)

  • 나정숙
    • 대한치과기공학회지
    • /
    • 제36권4호
    • /
    • pp.277-296
    • /
    • 2014
  • Purpose: This study intends to set standard for organizing the curriculum of short-term dental technicians and the change of job environment, as well as the knowledge & training, by identifying the importance and actual job performance of dental technicians following job analysis in the university education of Dept. of Dental Laboratory Technology, and furthermore to foster junior executives to cope with modernization and globalization. Methods: The tools used in this study are based on the job analysis of research report suggested by National Health Personnel Licensing Examination Board(Lee Gyu-seon, 2011), and it consists of general characteristic 7 items. Every competence duty was measured through Likert 5 point gauging, and internal consistency through Cronbach's Alpha. The competence importance of entire questionnaire was .984 and its performance was .874, reflecting considerably high level, and in terms of each competence duty, high credibility was proved and high internal consistency was verified with competence importance ranging from the minimum .655 to the maximum .966 and its performance ranging from the minimum .677 to the maximum .993. Results: Competence importance and its performance in each duty on the job analysis of dental technicians were measured. In competence importance in each duty, the highest was "checking design order form"(average, 4.52), followed by "selling dental prosthesis"(average 4.49), "making removable orthodontic appliance"(average, 4.48), "open managing dental laboratory"(average, 4.46) in order. However, "making complete denture" was found the lowest(average, 4.23), with importance of all competence dutys was considerably high level. In the performance of its competence duty, "checking design order form"(average, 4.04) was found to be the most importance competence, followed by "making conservative restoration"(average, 4.00), "making porcelain"(average 3.98), "checking working cast"(average, 3.90) in order. However it was found out that "making fixed orthodontic appliance"(average, 3.12) was the lowest, and the importance of all competence dutys was quite high level. Conclusion: The duties of dental technicians consist of 13 kinds, in total, and it was found out that "checking design order form"(average, 4.52) was the most important in the competence importance and job performance. In particular, it was revealed that there was a great difference between the competence importance and its performance in the order of "selling dental prosthesis", "open managing dental laboratory", "making removable orthodontic appliance", "making CAD/CAM prosthesis", and then "making fixed orthodontic appliance".

Analysis of midpalatal miniscrew-assisted maxillary molar distalization patterns with simultaneous use of fixed appliances: A preliminary study

  • Mah, Su-Jung;Kim, Ji-Eun;Ahn, Eun Jin;Nam, Jong-Hyun;Kim, Ji-Young;Kang, Yoon-Goo
    • 대한치과교정학회지
    • /
    • 제46권1호
    • /
    • pp.55-61
    • /
    • 2016
  • Skeletal anchorage-assisted upper molar distalization has become one of the standard treatment modalities for the correction of Class II malocclusion. The purpose of this study was to analyze maxillary molar movement patterns according to appliance design, with the simultaneous use of buccal fixed orthodontic appliances. The authors devised two distinct types of midpalatal miniscrew-assisted maxillary molar distalizers, a lingual arch type and a pendulum type. Fourteen patients treated with one of the two types of distalizers were enrolled in the study, and the patterns of tooth movement associated with each type were compared. Pre- and post-treatment lateral cephalograms were analyzed. The lingual arch type was associated with relatively bodily upper molar distalization, while the pendulum type was associated with distal tipping with intrusion of the upper molar. Clinicians should be aware of the expected tooth movement associated with each appliance design. Further well designed studies with larger sample sizes are required.

Treatment of Class I crowding using simple tubes bonded with customized resin coverings: A case report

  • Jeong, Seo-Rin;Kim, Hye-In;Lim, Sung-Hoon
    • 대한치과교정학회지
    • /
    • 제49권2호
    • /
    • pp.116-123
    • /
    • 2019
  • As an alternative to the conventional fixed appliance that uses orthodontic brackets, a simple round tube without a bonding base can be bonded to the tooth surface by covering the tube with flowable resin. In this technique, bent wires cannot be inserted into the simple tubes; therefore, repositioning of the simple tubes is often required for adjustments. To reduce repositioning of simple tubes, a dome-shaped resin covering of the simple tube can be designed with a customized in-and-out compensation, using three-dimensional computer-aided design software based on digital simulation of orthodontic tooth movement. In the present case, the use of simple tubes bonded with customized resin coverings in a Class I nonextraction case is described in a 17-year-old male, in whom moderate crowding of the anterior teeth was treated over an 8-month period. This case shows that simple tubes can be used as an alternative to brackets in some Class I nonextraction cases, with the potential benefit of reducing decalcification.

골성 고정원과 편측 분절호선을 이용한 정출된 상악 중절치의 압하 치료 (Intrusion of the extruded maxillary central incisor using skeletal anchorage system and unilateral segmental intrusion arch)

  • 권은영;백영재;박수병;김성식;김용일;최윤경
    • 구강회복응용과학지
    • /
    • 제35권3호
    • /
    • pp.180-190
    • /
    • 2019
  • 병적 치아 이동된 상악 전치를 가진 중등도 치주염 환자에서는 치태 관리를 통한 치주 염증의 해소뿐만 아니라 치아를 재위치 시키기 위한 교정치료가 함께 필요하다. 이 때의 교정치료는 더 적은 힘의 적용과 치아의 저항중심, 최적의 힘 등을 세심하게 고려해야 하는데, 이동하고자 하는 치아에만 적용되는 분절호선은 이동의 예측성을 높여주고, 힘을 조절할 수 있어 보다 효율적이다. 또한 교정치료 시, 고정원으로 사용되는 치아의 원치 않는 움직임을 차단하여 구치 교합 상태를 유지할 수 있는 장치 설계가 필요하며, 이를 위해 다양한 종류의 골성 고정원이 사용될 수 있다. 본 증례에서는 정출되고 변위된 상악 전치를 가진 환자에서, 철저한 치주 치료와 적절한 힘과 역학이 설계된 교정 장치로, 양호한 치료 결과를 얻을 수 있었으므로, 소개하고자 한다.

Comparison of transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system

  • Uzuner, Fatma Deniz;Kaygisiz, Emine;Unver, Fatih;Tortop, Tuba
    • 대한치과교정학회지
    • /
    • 제46권2호
    • /
    • pp.96-103
    • /
    • 2016
  • Objective: To compare the transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system (KIDS). Methods: We evaluated the pre- and post distalization orthodontic models of 39 patients, including 19 treated using the Frog appliance, which is palatally positioned (Frog group), and 20 treated using KIDS, which is buccally positioned (KIDS group). Changes in intermolar and interpremolar distances and the amount of maxillary premolar and molar rotation were evaluated on model photocopies. Wilcoxon and Mann-Whitney U tests were used for statistical evaluations. A p-value of < 0.05 was considered statistically significant. Results: Significant distopalatal rotation of premolars and distobuccal rotation of molars were observed in Frog group (p < 0.05), while significant distopalatal rotation of molars (p < 0.05), with no significant changes in premolars, was observed in KIDS group. The amount of second premolar and first molar rotation was significantly different between the two groups (p < 0.05 and p < 0.001, respectively). Furthermore, expansion in the region of the first molars and second premolars was significantly greater in KIDS group than in Frog group (p < 0.001 for both). Conclusions: Our results suggest that the type and amount of first molar rotation and expansion vary with the design of the distalization appliance used.

Dentoalveolar effects of open-bite correction with the dual action vertical intra-arch technique: A finite element analysis

  • Sergio Estelita Barros;Kelly Chiqueto;Franciele Alberton;Katherine Jaramillo Cevallos;Juliana Faria;Bianca Heck;Leonardo Machado;Pedro Noritomi
    • 대한치과교정학회지
    • /
    • 제54권5호
    • /
    • pp.316-324
    • /
    • 2024
  • Objective: To evaluate tooth displacement and periodontal stress generated by the dual action vertical intra-arch technique (DAVIT) for open-bite correction using three-dimensional finite element analysis. Methods: A three-dimensional model of the maxilla was created by modeling the cortical bone, cancellous bone, periodontal ligament, and teeth from the second molar to the central incisor of a hemiarch. All orthodontic devices were designed using specific software to reproduce their morpho-dimensional characteristics, and their physical properties were determined using Young's modulus and Poisson's coefficient of each material. A linear static simulation was performed to analyze the tooth displacements (mm) and maximum stresses (Mpa) induced in the periodontal ligament by the posterior intrusion and anterior extrusion forces generated by the DAVIT. Results: The first and second molars showed the greatest intrusion, whereas the canines and lateral incisors showed the greatest extrusion displacement. A neutral zone of displacement corresponding to the fulcrum of occlusal plane rotation was observed in the premolar region. Buccal tipping of the molars and lingual tipping of the anterior teeth occurred with intrusion and extrusion, respectively. Posterior intrusion generated compressive stress at the apex of the buccal roots and furcation of the molars, while anterior extrusion generated tensile stress at the apex and apical third of the palatal root surface of the incisors and canines. Conclusions: DAVIT mechanics produced a set of beneficial effects for open-bite correction, including molar intrusion, extrusion and palatal tipping of the anterior teeth, and occlusal plane rotation with posterior teeth uprighting.

분리형 미니 임플란트를 이용한 효과적인 악간고정법의 소개 (TWO PART MINI-IMPLANT AS AN EFFICIENT TOOL FOR INTERMAXILLARY FIXATION)

  • 이원;김인수;서운경;허현아;김성훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권5호
    • /
    • pp.477-482
    • /
    • 2006
  • The new type of orthodontic mini-implant named C-implant can be an effective alternative to conventional one-component mini-implant in the intermaxillary fixation (IMF) cases because of its particular design. The small size, two-part design, efficiency, and low cost of the C-implant make it applicable to various types of IMF cases easily such as fracture reduction and orthognathic surgery. The two part design resists highly to the fracture or deformation during implantation and removal. The long span head allows the patient to easily attach intermaxillary elastics, so that the patient can apply intermaxillary elastics for traction easily. Through this article, we tried to show the possibility of this appliance as a good adjunct for the IMF screw.