DOI QR코드

DOI QR Code

Comparison of transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system

  • Uzuner, Fatma Deniz (Department of Orthodontics, Faculty of Dentistry, Gazi University) ;
  • Kaygisiz, Emine (Department of Orthodontics, Faculty of Dentistry, Gazi University) ;
  • Unver, Fatih (Department of Orthodontics, Faculty of Dentistry, Gazi University) ;
  • Tortop, Tuba (Department of Orthodontics, Faculty of Dentistry, Gazi University)
  • Received : 2015.07.01
  • Accepted : 2015.09.07
  • Published : 2016.03.25

Abstract

Objective: To compare the transverse dental changes induced by the palatally applied Frog appliance and buccally applied Karad's integrated distalizing system (KIDS). Methods: We evaluated the pre- and post distalization orthodontic models of 39 patients, including 19 treated using the Frog appliance, which is palatally positioned (Frog group), and 20 treated using KIDS, which is buccally positioned (KIDS group). Changes in intermolar and interpremolar distances and the amount of maxillary premolar and molar rotation were evaluated on model photocopies. Wilcoxon and Mann-Whitney U tests were used for statistical evaluations. A p-value of < 0.05 was considered statistically significant. Results: Significant distopalatal rotation of premolars and distobuccal rotation of molars were observed in Frog group (p < 0.05), while significant distopalatal rotation of molars (p < 0.05), with no significant changes in premolars, was observed in KIDS group. The amount of second premolar and first molar rotation was significantly different between the two groups (p < 0.05 and p < 0.001, respectively). Furthermore, expansion in the region of the first molars and second premolars was significantly greater in KIDS group than in Frog group (p < 0.001 for both). Conclusions: Our results suggest that the type and amount of first molar rotation and expansion vary with the design of the distalization appliance used.

Keywords

References

  1. Papadopoulos MA. Orthodontic treatment of the Class II noncompliant patient. Current principles and techniques. Edinburgh: Mosby Elsevier; 2006.
  2. Fontana M, Cozzani M, Caprioglio A. Non-compliance maxillary molar distalizing appliances: an overview of the last decade. Prog Orthod 2012;13:173-84. https://doi.org/10.1016/j.pio.2011.10.002
  3. Kinzinger GS, Eren M, Diedrich PR. Treatment effects of intraoral appliances with conventional anchorage designs for non-compliance maxillary molar distalization: a literature review. Eur J Orthod 2008;30:558-71. https://doi.org/10.1093/ejo/cjn047
  4. Kinzinger GS, Fritz UB, Sander FG, Diedrich PR. Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage. Am J Orthod Dentofacial Orthop 2004;125:8-23. https://doi.org/10.1016/j.ajodo.2003.02.002
  5. Mariani L, Maino G, Caprioglio A. Skeletal versus conventional intraoral anchorage for the treatment of class II malocclusion: dentoalveolar and skeletal effects. Prog Orthod 2014;15:43 https://doi.org/10.1186/s40510-014-0043-z
  6. Grec RH, Janson G, Branco NC, Moura-Grec PG, Patel MP, Castanha Henriques JF. Intraoral distalizer effects with conventional and skeletal anchorage: a meta-analysis. Am J Orthod Dentofacial Orthop 2013;143:602-15. https://doi.org/10.1016/j.ajodo.2012.11.024
  7. Fontana M, Cozzani M, Mutinelli S, Spena R, Caprioglio A. Maxillary molar distalization therapy in adult patients: a multicentre study. Orthod Craniofac Res 2015;18:221-31 https://doi.org/10.1111/ocr.12098
  8. Ludwig B, Glasl B, Kinzinger GS, Walde KC, Lisson JA. The skeletal frog appliance for maxillary molar distalization. J Clin Orthod 2011;45:77-84.
  9. Karad A. KIDS: a new approach to distalize maxillary molars. World J Orthod 2008;9:244-54.
  10. Braun S, Kusnoto B, Evans CA. The effect of maxillary first molar derotation on arch length. Am J Orthod Dentofacial Orthop 1997;112:538-44. https://doi.org/10.1016/S0889-5406(97)70081-7
  11. Korn M, Melsen B. Early treatment with a maxillary lip bumper-bite plateau combination. Angle Orthod 2008;78:838-46. https://doi.org/10.2319/092807-463.1
  12. Hourfar J, Ludwig B, Kanavakis G. An active, skeletally anchored transpalatal appliance for derotation, distalization and vertical control of maxillary first molars. J Orthod 2014;41 Suppl 1:S24-32. https://doi.org/10.1179/1465313314Y.0000000102
  13. Nalcaci R, Kocoglu-Altan AB, Bicakci AA, Ozturk F, Babacan H. A reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital models. Korean J Orthod 2015;45:82-8. https://doi.org/10.4041/kjod.2015.45.2.82
  14. Maino G, Mariani L, Bozzo I, Maino G, Caprioglio A. Maxillary molar distalization with MGBM-system in class II malocclusion. J Orthod Sci 2013;2:101-8. https://doi.org/10.4103/2278-0203.119683
  15. Kinzinger GS, Wehrbein H, Diedrich PR. Molar distalization with a modified pendulum appliance--in vitro analysis of the force systems and in vivo study in children and adolescents. Angle Orthod 2005;75:558-67.
  16. Kircelli BH, Pektas ZO, Kircelli C. Maxillary molar distalization with a bone-anchored pendulum appliance. Angle Orthod 2006;76:650-9.
  17. Kinzinger GS, Gulden N, Yildizhan F, Diedrich PR. Efficiency of a skeletonized distal jet appliance supported by miniscrew anchorage for noncompliance maxillary molar distalization. Am J Orthod Dentofacial Orthop 2009;136:578-86. https://doi.org/10.1016/j.ajodo.2007.10.049
  18. Erverdi N, Koyuturk O, Kucukkeles N. Nickeltitanium coil springs and repelling magnets: a comparison of two different intra-oral molar distalization techniques. Br J Orthod 1997;24:47-53. https://doi.org/10.1093/ortho/24.1.47
  19. Bondemark L, Kurol J. Distalization of maxillary first and second molars simultaneously with repelling magnets. Eur J Orthod 1992;14:264-72. https://doi.org/10.1093/ejo/14.4.264
  20. Papadopoulos MA, Melkos AB, Athanasiou AE. Noncompliance maxillary molar distalization with the first class appliance: a randomized controlled trial. Am J Orthod Dentofacial Orthop 2010;137:586.e1-586.e13.
  21. Acar AG, Gursoy S, Dincer M. Molar distalization with a pendulum appliance K-loop combination. Eur J Orthod 2010;32:459-65. https://doi.org/10.1093/ejo/cjp136
  22. Bayram M, Nur M, Kilkis D. The frog appliance for upper molar distalization: a case report. Korean J Orthod 2010;40:50-60. https://doi.org/10.4041/kjod.2010.40.1.50
  23. Champagne M. Reliability of measurements from photocopies of study models. J Clin Orthod 1992;26:648-50.
  24. Dahlberg G. Statistical methods for medical and biological students. New York: Interscience Publications; 1940.
  25. Antonarakis GS, Kiliaridis S. Maxillary molar distalization with noncompliance intramaxillary appliances in Class II malocclusion. A systematic review. Angle Orthod 2008;78:1133-40. https://doi.org/10.2319/101507-406.1
  26. Burhan AS. Combined treatment with headgear and the Frog appliance for maxillary molar distalization: a randomized controlled trial. Korean J Orthod 2013;43:101-9. https://doi.org/10.4041/kjod.2013.43.2.101
  27. Ghosh J, Nanda RS. Evaluation of an intraoral maxillary molar distalization technique. Am J Orthod Dentofacial Orthop 1996;110:639-46. https://doi.org/10.1016/S0889-5406(96)80041-2
  28. Cetlin NM, Ten Hoeve A. Nonextraction treatment. J Clin Orthod 1983;17:396-413.
  29. Fuziy A, Rodrigues de Almeida R, Janson G, Angelieri F, Pinzan A. Sagittal, vertical, and transverse changes consequent to maxillary molar distalization with the pendulum appliance. Am J Orthod Dentofacial Orthop 2006;130:502-10. https://doi.org/10.1016/j.ajodo.2004.12.031
  30. Bolla E, Muratore F, Carano A, Bowman SJ. Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods. Angle Orthod 2002;72:481-94.

Cited by

  1. Three-dimensional evaluation of maxillary dentoalveolar changes and airway space after distalization in adults vol.88, pp.2, 2016, https://doi.org/10.2319/121116-889.1