• 제목/요약/키워드: Organic Removal

검색결과 1,920건 처리시간 0.028초

휘발성 지방산의 주입을 통한 생물학적 영양염류 제거공정의 효율증진에 관한 연구 (Enbancement of Treatement Efficiency in a Biological Nutrient Removal Process by addition of Volatile Fatty Acids)

  • 정연규;고광백;김수진;임성균
    • 상하수도학회지
    • /
    • 제10권3호
    • /
    • pp.73-82
    • /
    • 1996
  • The removal efficiencies of organic substrates, nitrogen and phosphorus in the anaerobic-aerobic biological phosphorus removal process were investigated by addition of acetic acid, propionic acid and butyric acid which are normal volatile fatty acids contained in anaerobic digester supernatants. Substrate utilization coefficients for the phosphorus release and uptake were also estimated. The effect of a VFA, which showed higher phosphorus removal efficiency than the other VFAs did, was also studied in an anaerobic-aerobic-anoxic biological nutrient removal process. For the anaerobic-aerobic process added by VFA, the phosphorus removal efficiencies were up to about 68%, 55% and 61% for the reactors of acetic acid, propionic acid and butyric acid added, respectively, which indicates the efficiencies were increased by about 8-21%, comparing to that of 47% for the reactor with no VFA added. There were no significant difference in removal efficiencies for organic substrate and $NH_3-N$ without regard to addition of VFA. However, the removal efficiency of total nitrogen was increased in the case of VFA added, since $NO_3-N$ was less produced. For the anaerobic-aerobic-anoxic process added VFA, the removal efficiencies for $NH_3-N$ and $PO{_4}^{3-}-P$ were increased by 5% and 13%, respectively, comparing with them in the reactors not added VFA.

  • PDF

BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거 (Nutrient Removal in an Advanced Treatment Process using BIO-CLOD)

  • 박완철;이미애;성일화
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

자성체 이온교환 수지와 PACI 응집에 의한 국내 주요 수계 내 자연유기물 제거 특성 및 막오염 저감 효과 (Effects of magnetic ion exchange resin with PACI coagulation on removal of natural organic matter and MF fouling)

  • 최양훈;정영미;김영삼;이승렬;권지향;권순범
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.131-140
    • /
    • 2008
  • The application of magnetic ion exchange resin($MIEX^{(R)}$) is effective for natural organic matter(NOM) removal and for control of the formation of disinfection byproducts(DBPs). NOM removal is also enhanced by adding $MIEX^{(R)}$ with coagulant such as polyaluminium chloride(PACl) in conventional drinking water treatment systems. In the application of $MIEX^{(R)}$, it is important to understand changes of NOM characteristics such as hydrophobicity and molecular weight distributions with $MIEX^{(R)}$ or $MIEX^{(R)}$+coagulant treatment.To observe characteristics of NOM by treatment with $MIEX^{(R)}$ or $MIEX^{(R)}$+coagulant, four major drinking water sources were employed. Results showed that the addition of $MIEX^{(R)}$ to coagulation significantly reduced the amount of coagulant required for the optimum removal of dissolved organic matter(DOC) and turbidity in the all four waters. The DOC removal was also increased approximately 20%, compared to coagulant treatment alone. The process with $MIEX^{(R)}$ and coagulant showed that complementary removal of hydrophobic and hydrophilic fraction of DOC. The combined processes preferentially removed the fractions of intermediate (3,000-10,000 Da) and low (< 500 Da) molecular weight. The microfiltration test showed that membrane cake resistance was decreased for waters with flocs from $MIEX^{(R)}$+coagulant. A porous layer was formed to $MIEX^{(R)}$ on the membrane surface and the layer consequently inhibited settling of coagulant flocs, which could act on a foulant.

하·폐수 처리시설 내 유입수 특성이 유기물 처리효율에 미치는 영향 (Effects of the Characteristics of Influent Wastewater on Removal Efficiencies for Organic Matters in Wastewater Treatment Plants)

  • 이태환;박민혜;이보미;허진;양희정
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.674-681
    • /
    • 2009
  • Characteristics of organic matters (OM) in wastewater and the removal efficiencies were investigated using the influent and the effluent samples collected from 21 wastewater treatment plants. The OM characteristics investigated included biodegradability, humic content, specific UV absorbance (SUVA), the distribution percentage of refractory OM (R-OM), and synchronous fluorescence spectra. The types of wastewater (sewage, livestock waste/night soils, industrial waste) were easily distinguished by comparing the synchronous fluorescence spectra of the influent wastewater. The prominent peak of protein-like fluorescence (PLF) was observed for livestock waste/night soils whereas sewage exhibited a unique fluorescence peak at a wavelength of 370 nm. Irrespective of the wastewater types, the distribution percentage of R-OM increased from the influent to the effluent. Livestock waste/night soils showed the highest removal efficiency among all the three types of wastewater. There was no statistical difference of the removal efficiency between a traditional activated sludge and biological advanced treatment processes. Removal efficiency based on dissolved organic carbon DOC presented good correlations with the distribution percentage of R-OM and fulvic-like fluorescence (FLF) of the influent. The prediction for DOC removal efficiency was improved by using multiple regression analyses based on some selected OM characteristics and mixed liquid suspended solid (MLSS).

회분식 혐기성 소화 반응기에서 음식물탈리액과 양돈폐수의 혼합비에 따른 수소 생산 및 유기물 제거 (Hydrogen Production and Organic Removal according to Mixture Ratio of Food Wastewater and Swine Wastewater using Anaerobic Batch Reactor)

  • 김충곤;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.641-647
    • /
    • 2007
  • This study aims to find out optimum condition for hydrogen production and organic removal when treating food and swine wastewater together. For this purpose, various batch tests were conducted by changing mixture ratio from 6:4 (food wastewater:swine wastewater) to 1:9 without pretreatment process. For hydrogen production through anaerobic fermentation, the mixture ratios of R-1 (6:4), R-2 (5:5) and R-6 (1:9) were out of pH range appropriate for hydrogen production and mixture ratios of R-3 (4:6), R-4 (3:7), and R-5(2:8) showed appropriate hydrogen production where their pH ranges were 5.1~5.5. Especially in case of R-3, it consistently maintained appropriate pH range for hydrogen production for 72hr and produced maximum hydrogen. The characteristics of hydrogen production and cumulative hydrogen production according to each mixture ratio showed that R-1, R-2 and R-6 did not produce any hydrogen, and maximum hydrogen productions of R-3, R-4 and R-5 were 593ml, 419ml and 90ml, respectively. Total cumulative hydrogen productions of R-3, R-4 and R-5 were 1690ml, 425ml and 96ml, respectively. Based on previous results, it was concluded that, the most appropriate mixture ratio of food wastewater and swine wastewate rwas 4:6 (R-3). The experiment for COD removal rate to evaluate organic removal efficiency revealed that R-3, R-4 and R-5 showed high removal efficiencies during the highest hydrogen production amount and the highest efficiency was 41% with R-3.

광촉매 반응과 침지형 정밀여과를 이용한 자연산 유기물의 제거 (Use of a Combined Photocatalysis/Microfiltration System for Natural Organic Matter Removal)

  • 추광호;박경원;김문현
    • 멤브레인
    • /
    • 제14권2호
    • /
    • pp.149-156
    • /
    • 2004
  • 본 연구에서는 광촉매 반응과 막분리 기술을 접목시킨 혼성 고도 정수처리 공정에서 소독 부산물의 전구체로 알려진 자연산 유기물을 효과적으로 제거하고자 하였고 다양한 운전 조건에서 시스템의 성능을 비교 평가하였다. 자연산 유기물은 흡입여과 방식의 분리막과 TiO$_2$ 광촉매를 이용하여 광분해하였을 때 광촉매 투입량의 증가에 따라 반응속도가 증가하였지만 과량의 촉매 주입시에는 반응 속도 향상에 오히려 부정적으로 작용하였다. 자연산 유기물을 보다 효과적으로 제거하기 위해 산화철 주입, TiO$_2$ 표면처리, 분리막 표면코팅을 시도하여 제거특성 및 운전에 따른 막여과 특성을 평가하였다. 산화철 주입은 초기에 흡착작용으로 인해 제거율 증가를 보였으나 반응이 진행됨에 따라 산화철 입자에 의한 광산란으로 광분해 효율이 오히려 감소되었다. 산화철 입자에 의한 광산란을 제어하고자 TiO$_2$ 표면을 광처리와 열처리 방법을 이용해 철을 직접 부착시킨 경우 긍정적인 효과를 얻지 못했다. 그러나 산화철로 막표면을 코팅하여 광산란 효과를 배제시킨 경우에는 향상된 결과를 보였다 막투과 플럭스 15 L/$m^2$-h에서 정밀여과를 수행하였을 때 TiO$_2$나 산화철에 의한 막오염은 거의 일어나지 않았고 안정된 막투과도를 나타내었다.

SBR을 이용한 하수와 우사폐수로 구성된 혼합폐수의 영양소 제거 (The Nutrient Removal of Mixed Wastewater composed of Sewage and Stable Wastewater using SBR)

  • 김홍태
    • 한국환경과학회지
    • /
    • 제8권5호
    • /
    • pp.617-623
    • /
    • 1999
  • This study was carried out to obtain the optimal operating parameter on organic matters and nutrient removal of mixed wastewater which was composed of sewage and stable wastewater using SBR. A laboratory scale SBR was operated with An/Ae(Anaerobic/Aerobic) ratio of 3/3, 2/4 and 4/2(3.5/2.5) at organic loading rate of 0.14 to 0.27 kgBOD/$m^3$/d. TCOD/SCOD ratio of mixed wastewater was 3, so the important operating factor depended upon the resolving the particulate parts of wastewater. Conclusions of this study were as follows: 1) For mixed wastewater, BOD and COD removal efficiencies were 93-96% and 85-89%, respectively. It was not related to each organic loading rate, whereas depended on An/Ae ratio. During Anarobic period, the amount of SCOD consumption was very little, because ICOD in influent was converted to SCOD by hydrolysis of insoluble matter. 2) T-N removal efficiencies of mixed wastewater were 55-62% for Exp. 1, 66-76% for Exp. 2, and 67-81% for Exp. 3, respectively. It was found that nitrification rate was increased according to organic concentration in influent increased. Therefore, the nitrification rate seemed to be achieved by heterotrophs. During anoxic period, denitrification rate depended on SCOD concentration in aerobic period and thus, was not resulted by endogenous denitrification. However, the amount of denitrification during anaerobic period were 3.5-14.1 mg/cycle, and that of BOD consumed were 10-40 mg/cycle. 3) For P removal of mixed wastewater, EBPR appeared only Mode 3($3^*$). It was found that the time in which ICOD was converted to VFA should be sufficient. For mode 3 in each Exp., P removal efficiencies were 74, 87, and 81%, respectively. But for 45-48 of COD/TP ratio in influent, P concentration in effluent was over 1 mg/L. It was caused to a large amount of ICOD in influent. However, as P concnetration in influent was increased, the amounts of P release and uptake were increased linearly.

  • PDF

Performance evaluation of organic matter adsorption from actual graywater using GAC: OrbitrapTM MS and optimization

  • Ligaray, Mayzonee;Kim, Minjeong;Shim, Jaegyu;Park, Jongkwan;Cho, Kyung Hwa
    • Membrane and Water Treatment
    • /
    • 제10권6호
    • /
    • pp.471-484
    • /
    • 2019
  • The complex combination of organic contaminants in the wastewater made water treatment challenging; hence, organic matter in water bodies is usually measured in terms of organic carbon. Since it is important to identify the types of compounds when deciding suitable treatment methods, this study implemented a quantitative and qualitative analysis of the organic matter content in an actual graywater sample from Ulsan, Republic of Korea using mass spectroscopy (MS). The graywater was treated using adsorption to remove the organic contaminants. Using orbitrap MS, the organic matter content between an untreated graywater and the treated effluent were compared which yielded a significant formula count difference for the samples. It was revealed that CHON formula has the highest removal count. Isotherm studies found that the Freundlich equation was the best fit with a coefficient of determination ($R^2$) of 0.9705 indicating a heterogenous GAC surface with a multilayer characteristic. Kinetics experiments fit the pseudo-second order equation with an $R^2$ of 0.9998 implying that chemisorption is the rate-determining step between the organic compounds and GAC at rate constant of $52.53g/mg{\cdot}h$. At low temperatures, the reaction between GAC and organic compounds were found to be spontaneous and exothermic. The conditions for optimization were set to achieve a maximum DOC and TN removal which yielded removal percentages of 94.59% and 80.75% for the DOC and TN, respectively. The optimum parameter values are the following: pH 6.3, 2.46 g of GAC for every 30 mL of graywater sample, 23.39 hrs contact time and $38.6^{\circ}C$.

Stapylococcus auricularis에 의한 인 제거에서 총유기탄소의 영향 (Effect of the Total Organic Carbon(TOC) on phosphorus removal by Stapylococcus auricularis)

  • 최석순
    • 환경위생공학
    • /
    • 제15권3호
    • /
    • pp.57-61
    • /
    • 2000
  • Stapylococcus auricularis was used for the simultaneous removal of phosphorus and Total Organic Carbon(TOC) in the wastewater from sewage and various industries. In this study, the characteristics of phosphorus removal was investigated with initial ratio of TOC phosphorus in the synthetic wastewater. When the synthetic wastewater containing 15mg/L of phosphorus was treated under anaerobic and conditions, phosphorus was removed completely within 6 hours of operation. And when the initial ratio of TOC to phosphorus was 30, as high as 10 times the removal rate of phosphorus by Acinetobacter calcoaceticus was achieved. These results implied that a long adaptation time, one of the chief problems in biological phosphorus removal process was overcome.

  • PDF

육상양식장 배출수내 생물학적 질소처리시 수리학적 체류시간의 영향 (Effect of Hydraulic Retention Time on Biological Nitrogen Removal in Land-based Fish Farm Wastewater)

  • 박노백
    • 한국수산과학회지
    • /
    • 제50권3호
    • /
    • pp.250-256
    • /
    • 2017
  • This study investigated the removal efficiency of organic matter and nitrogen from fish farm effluent by hydraulic retention time (HRT) using an upflow biological filter (ANR system) reactor. The recycling time and influent flow in the reactor were controlled to 14.8, 7.4, 5.5 and 3.2 h to evaluate HRT. In addition, each reactor was coupled to a fixed bed upflow filter charged with media. The results showed that removal efficiency was ${\geq}95%%$ with an HRT of 5.5 h, and nitrification efficiency was reduced to 81% with an HRT of 3.2 h, although nitrification efficiency temporarily decreased due to the shock load as HRT decreased. Total nitrogen removal rate was also reduced to about 65% with an HRT of 3.2 h, which was considered a washout effect of nitrifying and denitrifying microorganisms by increasing the shearing force to the filter media, which decreased organic matter and nitrogen removal efficiency.