• Title/Summary/Keyword: Optometry

Search Result 579, Processing Time 0.02 seconds

Measurement of minimum line width of an object fabricated by metal 3D printer using powder bed fusion type with stainless steal powder (스테인리스강을 사용한 분말 적층 용융 방식의 금속 3차원 프린터에서 제작된 물체의 최소 선폭 측정)

  • Son, BongKuk;Jeong, Youn Hong;Jo, Jae Heung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.346-351
    • /
    • 2018
  • Metal three-dimensional (3D) printing technologies are mainly classified as powder bed fusion (PBF) and direct energy deposition (DED) methods according to the method of application of a laser beam to metallic powder. The DED method can be used to fabricate fine and hard 3D metallic structures by applying a strong laser beam to a thin layer of metallic powder. The PBF method involves slicing 3D graphics to be a certain height, laminating metal powders, and making a 3D structure using a laser. While the DED method has advantages such as laser cladding and metallic welding, it causes problems with low density when 3D shapes are created. The PBF method was introduced to address the structural density issues in the DED method and makes it easier to produce relatively dense 3D structures. In this paper, thin lines were produced by using PBF 3D printers with stainless-steel powder of roughly $30{\mu}m$ in diameter with a galvano scanner and fiber-transferred Nd:YAG laser beam. Experiments were carried out to find the optimal conditions for the width of a line depending on the processing times, laser power, spot size, and scan speed. The optimal conditions were two scanning processes in one line structure with a laser power of 30 W, spot size of $28.7{\mu}m$, and scan speed of 200 mm/s. With these conditions, a minimum width of about $85.3{\mu}m$ was obtained.

Comparison of Autorefraction and Refraction with iTrace for Elementary School Children (초등학생의 자동안굴절계와 iTrace로 측정한 굴절검사 값의 비교)

  • Kim, Hyojin;Lee, Koon-Ja;Kim, Sam-Yi;Kim, Se-Rom
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.99-104
    • /
    • 2010
  • Purpose: Difference of refraction result from the method of autorefraction and iTrace were investigaged for the children of elementary school in Asan City. In iTrace method. exclusion of accommodation without cycloplegia was used. Methods: Manifest refractive stale of 42 eyes of 12~13 years old were measured using autorefractor and iTrace. Refractions of far (more than 5 m) and ncar (30 cm) vision were measured using iTrace. All data showed that the spherical equivalent were classified as being in the group 1 (-0.50D < ~ < +1.00D) and 2 (below -0.50D) according 10 refractive errors. Results: Mean spherical equivalent using autorefractor and iTrace (far and near vision) were -1.08D, -0.29D and -2.34D, respectively (p<0.01). Compared with the far vision using iTrace, autorefraction was measured the myopia with -0.50D ~ -1.00D in 52.4% of total eyes. Autorefraction also statistical significant were measured a more myopia than the far vision using iTrace in group I and 2. Conclusions: The difference of refractive errors between autorefraction and iTrace, objective refraction were measured with far vision of more than 5 m were -0.79D. Autoreftaction showed statistically decreased refraction errors than iTrace with far vision.

Development on a Roofed Pechan Prism Type Scope with Long Eye Relief (긴 안점거리를 갖는 지붕형 페찬 프리즘 타입 스코프 개발)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.247-255
    • /
    • 2010
  • Purpose: Developing a roofed Pechan prism type scope with long eye relief. Methods: To reduce the overall length and to lengthen the eye relief of scope, the objective part was designed by adopting the roofed Pechan prism and also the eyepiece part was designed by adopting the field lens with minus refractive power in front of reticle, respectively. Finally, by integrating above two parts, the roofed Pechan prism type scope with 90 mm eye relief was developed. Results: The characteristics of the developed and fabricated scope with 90 mm eye relief by integrating the objective part with the roofed Pechan prism and the eyepiece part with minus refractive power had the magnification of $+3.0{\times}$, the length from the 1st lens to the last lens of about 121 mm, the barrel diameter of 28 mm, and the effective objective-diameter of 17 mm. Also it was found that the line width of resolution was about 900 cycles/rad at the 50% MTF value criterion. Conclusions: We could design and manufacture the roofed Pechan prism type scope with 90 mm eye relief, the characteristics of which had the magnification of $3.0{\times}$, the MTF above 50% at 900 cycles/rad, and the length from the 1st lens to the last lens of about 121 mm.

Presbyopic Spectacle and Monovision for Reading Performance Before Adaptation (노안안경과 모노비젼 콘택트렌즈 착용 후 적응 전 읽기 능력 평가)

  • Chu, Byoung Sun;Hwang, Jeong Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 2010
  • Purpose: Eye movements and fixation ability are an important procedure to obtain external information and essential means of clear vision. The purpose of this study was to determine the reading performance such as reading time and number of fixations when random text was viewed at varying distances. Methods: Twenty two presbyopes were participated. All subjects were screened for their suitability to participate in the study by clinical examination, and none of the participants had previously worn contact lenses and no previous experience of wearing any types of presbyopic vision correction except single vision. The reading time and number of fixations were recorded using eye tracker while each subjects was waring four vision corrections which included single vision for distance (SV), bifocal spectacle lenses (BIF), progressive addition lenses (PAL), and monovision (MV). The reading material was presented at distance and near distance. Results: Reading time and number of fixations for near stimulus were significantly different among vision correction used in this study (p<0.001). In particular, wearing SV required longer reading time and produced longer fixation duration for near text. However, reading distance text was similarity performed across vision corrections tested and there was no statistical difference found for either reading time and number of fixations. Conclusions: Wearing presbyopic vision correction is advantageous for reading task of near stimuli, but not having near correction such as wearing SV could result in longer reading time and higher number of fixation due to lacks of accommodative ability for near task. For the future studies, it would be interesting to examine the performance of reading both at adapted and unadapted stages as examining only unadapted wearers was limitation of this study.

A Study on the Reliability of Corrected Diopter according to Subjective refraction instrument (자각식굴절검사기기에 따른 교정굴절력의 신뢰도에 관한 연구)

  • Lee, Hark-Jun;Kim, Jung-Hee;Ryu, Kyung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.281-286
    • /
    • 2010
  • Purpose: This research provided basic data for refraction by comparing the corrected diopter of trial lens and phoropter. Methods: We compared the corrected diopter of trial lens and phoropter, and analyzed statistical significance and relations of the spherical lens corrected diopter and cylindrical lens corrected diopter according to the types (trial lens and phoropter) of subjective refractive instruments. Also we analyzed statistical significance and relations between cylindrical lens corrected diopter at the astigmatism and the types (trial lens and phoropter) of subjective refractory instruments. Results: When we measured the corrected diopter of simple myopia, the mean value for corrected diopter was S-2.74D using the trial lens and S-2.65D using the phoropter. So the corrected diopter was 0.09D smaller when measured by phoropter. The degree of astigmatism was measured C-0.81D using the trial lens and C-0.77D using the phoropter which showed that the measured value was 0.04D smaller using the phoropter. On correlation analysis between the refractive instruments (trial lens and phoropter) and the corrected diopter, there was significant (p<0.01) strong correlation between refractory machine and corrected spherical diopter (r=0.996) and the correlation between refractory machine and corrected cylindrical diopter was r=0.986 and was also significant (p<0.01). Conclusions: The use of phoropter than trial lens was more desirable when performing refraction on high myopia (simple refractive error, high astigmatism), and when using trial lens, you should consider the vertex distance and the gap between overlapped lenses before prescription.

Scotopic Pupil Size in Myopes (근시안에서 암순응상태의 동공크기)

  • Jeong, Woo-Jae;Jeon, In-Chul;Kang, Ji-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.197-202
    • /
    • 2013
  • Purpose: This research was performed to measure and analyze scotopic pupil size in myopes and to figure out the factors that influence it. Methods: The pupil size of 191 healthy myopic subjects were measured with the pupillometer (Colvard pupillometer, OASIS medical, USA) in scotopic and analyzed with the age, corneal size, spherical equivalent refractive error, corneal curvature. In addition, it was compared with the measurements of intra-examiner and inter-examiner to verify reproducibility of pupillometer. Results: The mean (${\pm}$SD) scotopic pupil size was $6.64{\pm}0.68$ mm (range, 5.00~8.00 mm), the lower age and the larger corneal size, The bigger the pupil size. The lower spherical equivalent refractive error and steepper corneal curvature tends to be smaller. The reproducibility of intra-examiner and inter-examiner in pupillometer showed the reliability highly (Guttman splithalf point > 0.91). Conclusions: The pupil size associated with age, corneal size, spherical equivalent refractive error and corneal curvature in scotopic condition. It can refer to prevent inconvenience that may occur RGP contact lenses, cataract surgery and refractive surgery.

The effects of a Leader's organizational citizenship behavior(OCB) on subordinates' interpersonal citizenship behavior(ICB) and job stress: Leader-Member Exchange(LMX) as a mediating variable (리더의 조직시민행동이 조직구성원들의 사람중심 시민행동과 스트레스에 미치는 영향: 리더-구성원 교환관계의 매개효과를 중심으로)

  • Moon, JeeYoung;Lee, JungHun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.230-239
    • /
    • 2020
  • The purpose of this study was to examine how a leader's organizational citizenship behavior (OCB) affects subordinates' interpersonal citizenship behavior (ICB) and job stress levels. A leader's OCB involves taking-charge behavior, loyal boosterism, and the industry. We hypothesized that leader-member exchange (LMX) would mediate the relationship between leader's OCB and subordinates' ICB and job stress level. We tested the model using a sample of 293 employees from different organizations from September 2019 until November 2019. We conducted confirmatory factor analyses of the variables and analyzed the data by using structural equation modeling. We also conducted a CFA to assess the fit of a three-factor model for the leader's OCB items. Empirical findings show that LMX fully mediated the effect of leader's OCB on employees' ICB and job stress level. Leader's OCB had a positive effect on LMX. Moreover, LMX had a positive effect on employees' ICB but had a negative effect on job stress. We found support for our hypotheses that leader's OCB is positively related to ICB but negatively related to job stress, and this relationship is mediated by LMX. We discuss limitations, implications for practice, and future research.

Effects of the Progression Control of Myopia on Myopia Control Lenses and Single Vision Lenses (Myopia Control 렌즈와 Single Vision 렌즈의 근시진행 조절 효과)

  • Jung, Ji-Won;Lee, Ki-Seok;Yoo, Wang-Keun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • Purpose: This paper was to study the clinical effects of moderating myopia by comparing the myopia control lens, which was being recently recognized as a method of inhibiting the progression of myopia, with the wearers of single vision lens. Methods: Using 56 subjects between the ages of 8-15 years (112 eyes) with myopia in the areas of City of Daegu and Gyeongsangbuk Province as study subjects, refractive error, axial length, near point of convergence and accommodative near point were measured and compared a total of 3 times at the baseline, after 1-month and after 6-months. Results: For refractive error, suppression and mitigation were seen in the progression of spherical equivalent when MC lens was worn, as compared to using SV lens, and, when axial length MC lens was worn, the axial progression was significantly suppressed and delayed (p < 0.05). The near point of convergence became shorter with the use of MC lens, and the amplitude of convergence was improved when MC lens was worn. Accommodative near point became shorter with the use of MC lens, and focus ability was significantly improved (p <0.05). Conclusions: It was shown that MC lens, compared to SV lens, could alleviate myopia progression in school-age children and youth. It is considered that MC lens can be used as a useful therapy for the inhibition of myopia progression in the increasing number of myopic children and adolescents.

Study on Color and Oxidation Thickness for Titanium Spectacle Frames Colored by Anodization (양극산화방법으로 착색한 티타늄 안경테의 산화막 두께에 따른 색상 연구)

  • Hyun, Seung-Cheol;Jin, Moon-Seog;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.33-37
    • /
    • 2009
  • Purpose: To examine the coloring condition of titanium spectacle frames with various colors by using anodization method. Methods: We made an anodization coater. Platinum plate with $3{\times}3cm^2$ was used for a cathode and titanium spectacle frame specimens was mounted on an anode in an electrolyte. An electric source device were designed to supply steady state current. The color of the coated spectacle frame specimens were measured by a spectrophotometer equipped with an integrating sphere. We use CIE $L^*a^*b$ color system as chromaticity coordinates. Results: The thickness of $TiO_2$ of titanium spectacle frame specimens was varied as controlling current flow time for electrodes. The specimens with various kinds of color as a walnut, a yellow brown, a navy blue, a blue, a light blue, a mung bean, a yellowish green, a light purple, a purple, a flower pink, a bluish green, an emerald, and a green color etc. were obtained. The values of CIE $L^*a^*b^*$ for these specimens were measured and analyzed to be changed clockwise in chromaticity coordinates as the thickness of $TiO_2$ increases. Conclusions: We identified the coloring mechanism by anodization method in titanium spectacle frame specimens.

  • PDF

A Study on the Clinical Practice in Ophthalmic Optics (안경광학과 임상실습 실태에 관한 연구)

  • Lee, Ok-Jin;Shin, Jin-Ah;Jung, Se-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.319-328
    • /
    • 2010
  • Purpose: To understand the status and actual condition of clinical practice in ophthalmic optics and offer a effective operation plan and improvement of quality of clinical practice. Methods: The school survey were investigated from 30 ophthalmic optics school and student survey were investigated from 161 students among these 4 schools. Results: 'No specific program for clinical practice' were 60.7%. Most schools apply clinical practice to credit (96.4%) but naming of subject and credit were varied in each school. 'Communication skill' was most difficult task and 'cleaning and arrangement of frame and stuff' were major task to students during clinical practice. Best benefits through clinical practice was 'knowing real status of optical business'. Comparison in carrier preference, optical shop and spectacles/contact lens company were decreased and eye hospital and norelation work were increased after clinical practice. Conclusions: Wide study on effective operation plan for clinical practice in ophthalmic optics and on the improvement of students' satisfaction and close cooperation and interest were needed between schools and clinical practice places.