Browse > Article

A Study on the Reliability of Corrected Diopter according to Subjective refraction instrument  

Lee, Hark-Jun (Department of Ophthalmic Optics, Wonkwang Health Science College)
Kim, Jung-Hee (Department of Optometry and Vision Science, Dongnam Health College)
Ryu, Kyung-Ho (Department of Ophthalmic Optics, Wonkwang Health Science College)
Publication Information
Journal of Korean Ophthalmic Optics Society / v.15, no.3, 2010 , pp. 281-286 More about this Journal
Abstract
Purpose: This research provided basic data for refraction by comparing the corrected diopter of trial lens and phoropter. Methods: We compared the corrected diopter of trial lens and phoropter, and analyzed statistical significance and relations of the spherical lens corrected diopter and cylindrical lens corrected diopter according to the types (trial lens and phoropter) of subjective refractive instruments. Also we analyzed statistical significance and relations between cylindrical lens corrected diopter at the astigmatism and the types (trial lens and phoropter) of subjective refractory instruments. Results: When we measured the corrected diopter of simple myopia, the mean value for corrected diopter was S-2.74D using the trial lens and S-2.65D using the phoropter. So the corrected diopter was 0.09D smaller when measured by phoropter. The degree of astigmatism was measured C-0.81D using the trial lens and C-0.77D using the phoropter which showed that the measured value was 0.04D smaller using the phoropter. On correlation analysis between the refractive instruments (trial lens and phoropter) and the corrected diopter, there was significant (p<0.01) strong correlation between refractory machine and corrected spherical diopter (r=0.996) and the correlation between refractory machine and corrected cylindrical diopter was r=0.986 and was also significant (p<0.01). Conclusions: The use of phoropter than trial lens was more desirable when performing refraction on high myopia (simple refractive error, high astigmatism), and when using trial lens, you should consider the vertex distance and the gap between overlapped lenses before prescription.
Keywords
Subjective refractive machine; Vertex distance; Corrected diopter;
Citations & Related Records
연도 인용수 순위
  • Reference
1 대한안경사협회(http://www.optic.or.kr). 2008년 전국 안경 사용율 보도자료.
2 김정희, 신진아, "굴절검사", 1판, 한미의학, 서울, pp 187-189(2008).
3 김효정, 이군자, 마기중, 정수정, 오현진, "안경 착용자의 불편감 조사", 대한시과학회지, 2(2):197-203(2000).
4 조영래, 유근창, 박현주, 성정섭, 김재민, "안경착용자의 휫팅 실태 조사", 대한시과학회지, 2(2):205-209(2000).
5 김정희, 이학준, "정점간거리 변화에 따른 교정상태의 임상평가", 한국안광학회지, 15(1):25-30(2010).
6 성풍주, "안경광학", 3판, 대학서림, 서울, pp. 83-84(2003).
7 마기중, 박수봉, 남상훈, "Clinical optometry, 대학서림, 서울, pp. 329-331(1999).
8 김상균, 성아영 , "고등학생 안경착용자의 착용상태에 관한 연구", 한국안광학회지, 9(1):19-27(2004).
9 박상열, 문병연, "국산시험렌즈세트의 실태조사", 대한시과학회지, 9(4):401-412(2007).
10 Sullivan C. M. and Flower C. W., "Investigation of Progressive Addition Lens patient tolerance to dispensing anomalies", Ophthal. Physiol. Opt., 10:16-20(1990).   DOI   ScienceOn